| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.5 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹48.0 L+₹2.6 L (5.63%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹53.2 L+₹7.8 L (17.0%)Rejected-AOC KATTUPADATH H AZHEEKAL PO VYPEEN 682508 | KOCHI | ERNAKULAM | KERALA | 682508 | L3 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹88,000
Closing Date
21 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SHRI DC SHARMA
CWE (NW) KOCHI
PREPATORY WORK FOR POSITIONING MOBILE AIR TRAFFIC CONTROL (MATC) AND SELLING UP OF INFRASTRUCTURE AND AMENITIES FOR MH 60 R CELL AT INS GARUDA, NAVAL BASE, KOCHI
2022_MES_571200_1
CWE(NW)/KOCHI/81337
Open Tender
Civil Works
Item Rate
180 days
KOCHI
AS PER NIT
7 documents required · 7 mandatory
₹500
GE (NW) KOCHI
₹88,000
Yes
21 Feb 2023
26 Dec 2022
23 Jan 2023
26 Dec 2022
21 Jan 2023
7 Jan 2023
Amount
S &F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming tofe -410W (gd E-250) quality A complete all as specified and as directed.
S&F for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet MP Tile pattern, 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S&F for pre painted plain sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding, fixed with screws all as specified and directed.
M&L for preparation of new steel and iron surface of any description over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of primer complete all as specified and as directed .
S & F SQUARE UPVC RAINWATER GUTTER (220 MM), with all necessary fittings, clamp, joints, end cap, corner drop, centre drop, etc joining compounds, nut, bolts or screws etc and fixing in position, at any height complete all as specified and as directed. Make: EURO GUARD or equivalent in list of makes.
S & F 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls (jointing shall be done with solvent cement) complete all as specified and as directed .
S & F PVC (SWR) bends, any radius, 110mm bore all as specified,complete all as specified and as directed .
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in Soft/loose soil complete all as specified and as directed.
M&L for 100mm thick cement concrete type D2, 1:4:8 (40mm graded aggregate) as in sub base complete all as specified and as directed .
M&L for Hard core of Gauge exc. 63mm but n. exc 150mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and rolled / rammed to a true surface complete all as specified and as directed .
M&L Coarse aggregate for granolithic floors graded from 12.5mm to 4.75mm Spreading and levelling and ramming as specified complete all as specified and as directed .
M/L Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of M 40 grade 80mm thickness, with grey cement and pigment complete all as specified and as directed by Engr-in-Charge.
M&L for PCC type B-0, 1:2:4 (12.50mm graded aggregate) as in mass concrete around the machine pressed pre cast concrete paver block or chamfered on edges all as specified and as directed .
Rolling and consolidating formation surfaces in cutting using power roller exc 8 tonne and not exc 12 tonne etc complete all as specified and as directed .
M&L Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering etc complete all as specified and as directed .
Rolling and consolidating moorum red bajri filling using power roller exc 2 tonne and not exc 5 tonne etc complete all as specified and as directed .
M&L for 100 mm thick PCC 1:4:8 type D2,Cement concrete in foundations, filling and mass concrete complete all as specified and as directed.
M&L for 400 micron polythene film black colour laid over hard core complete all as specified and as directed .
M&L for 300 mm thick PQC with minimum flexural strength 40 kg/per square centimetre of concrete and use of fixed form mechanical paver with sensor surface vibrator, vibrating screed needle vibrator complete all as specified and as directed .
M&L for CRS/HCRM TMT bars in reinforcement 10mm dia and over including cut to length , bend to required shape , cranking/hooking ends if necessary and binding with 0.9mm dia MS wire annealed or welding so as to secure the bar firmly in position/required shape complete all as specified and as directed .
M&L for Forming Construction joint 300 mm deep x 10mm wide filled with sealing compound grade'A', slab thickness 300 mm complete all as specified and as directed.
M&L for Forming Contraction (Dummy) joints 100 mm deep x 10mm wide, filled with sealing compound , grade 'A' complete all as specified and as directed.
Formwork to sides of concretefoundations, footings, bases ofcolumns, raft and raft beams,sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surfaces complete all as specified and as directed .
M & L for Removing excavated soil material n exc 50m & depositing where directed complete all as specified and as directed.
Supply and Lay UG cable in trenches/passing through pipes/fixed on walls or poles cable XLPE insulated, screened, PVC bedded, steel strip or wire armoured electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 3.5 core 50 sqmm with suitable cable gland complete all as specified and as directed.
Supply and Lay UG cable in trenches/passing through pipes/fixed on walls or poles cable XLPE insulated, screened, PVC bedded, steel strip or wire armoured electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 4 core 25 sqmm with suitable cable gland complete all as specified and as directed.
M/L for earthing complete with galavanised steel earth plate electrode 60cm x 60 cm x 6mm thick buried directly in ground (earth pit not less than 2.25mtr below ground level) with top edge of eath plate not less than 1.5mtr below ground level, connected to galvanised iron strip 32 x 6mm as earthing lead by means of bolts, nuts, washers of GI or steel, including PCC (concrete chamber) shall be PCC 1:3:6 type C 1 using 20mm raded stone aggregate, with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge of (0.68mm) 8 mesh per liner inch, 80mm thick RCC pit cover 320mm x 320mm of RCC 1:2:4 type B-1 using 20mm graded stone aggregate reinformed with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR part -I and specified including provision of earth wire protected by 40mm dia medium grade GI pipe and watering pipe shall be 20mm bore medium grade GI pipe, and including all excavation and earth work & connecting the earthing to an earthing test point/ transformer nuetral/body/ LT panel etc. and tesing on completion, complete all as specified & directed .
Supply and Fix 4 pole MCCB 63Amp, 50Hz, 415 V with rupturing capacity 35KA with enclosure complete all as specified and as directed.
Excavation in trenches soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth and getting out excavated soil/sand/unseviceable LT Cable for laying of cable complete all as specified and directed.
Sand cushioning and covering of UG cable using river sand in trenches for cable protection all as specified and directed. Note:- punned thickness only to be measured and paid
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in hard /loose soil complete all as specified and directed .
M&L for brick well burnt Class ‘B’ as cover to U/G cable laid dry flat over the cable with width equal to length of the cable and abutting each other with gap between adjacent slab not exceeding 10mm over under ground cable for cable protection in trenches all as specified and directed .
Supply and fixing GI pipe light grade with necessary fittings in floor /piller/fixed on pole of size 40 mm dia as cable protection complete all as specified and as directed.
M&L for point wiring with 1.5Sqmm PVC insulated unsheathed FRLSH multi stranded single cor copper conductor cable in stove enamelled steel conduit fixed on wall/roof including 1.5 Sqmm unsheathed FRLSH multi stranded single core PVC insulated copper conductor as earth continuity wire for one ligt/fan point controlled by one switch complete all as specified and as directed. Note: All accessories used in point wiring shall be flame retardant.
S&F flame proof rotary switch with cable termination boxes in LM6. Make Sudhir Cat part No. RI/OA/1010-2A 16A/Palika or equivalent make in approved list of makes complete all as specified and as directed.
S&F LED flame proof light fittings with tube 1X20W (CMRI certified) with IP 65 Protection including all connection complete all as specified and as directed. Make: EXTN1LT8-16/20 of crompton/sudhir/palika or equivalent in list of makes
S&F flame proof exhaust fans AC single phase 230/240V of size 305mm sweep with louver complete all as specified and as directed. Make Sudhir Cat part No. EF/140/Palika or equivalent in list of makes.
M/L submain wiring with 2 single core 4 Sqmm PVC insulated unsheathed multistranded copper conductor cable 1100 volt grade drawn throgh and including PVC rigid conduit concealed wiring inculding necessary PVC conduit specials including chases cutting complete exceapt beam and RCC roof and one run of 4Sqmm PVC insulated unshearthed single core 1100 volts grade multistranded copper conductor cable as earth continuity conduto9r and connceting with suitable size thimble complete allas specified and as directed. Note: two run of 4 sqmm size PVC cable , one run of 4 Sqmm size PVC cable as earth wire and one run of PVC conduit shall be measured as one unit length
S&F sheet metal enclosure SPN for DBs when MCB's to be used 4 way with 200A bus bar double door complete all as specified and as directed.
S&F MCB B curve 16A SPN 240V complete all as specified and as directed/. Make Legrand/ABB/Schneider or equivalent make in list of makes.
S&F MCB B curve SP 10A 240V,10KA complete all as specified and as directed/. Make Legrand/ABB/Schneider or equivalent make in list of makes.
REIGN CONSTRUCTIONS
MS BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .