Loading…
Loading…
Tender Value
₹38.0 L
EMD Value
₹38,100
Closing Date
3 Sept 2026, 3:00 pm6d left
Chief Engineer, TTD, Tirupathi
Room No.132, Ground floor, TTD Admn. Bldg., KT Road, Tirupati
AME for UPS Systems, AMF and APFC Panels available in S.V.Ayurvedic Hospital and BIRRD Hospital in ESD-SBH, Tirupati for 3 (three) years from 2026-29
978424
27/SE(Elec)/TTD/TPT/2026-27
OPEN - NCB
Annual maintenance works
TIRUPATHI
6 documents required · 6 mandatory
₹1,347
₹38,100
19 Aug 2026
19 Aug 2026
19 Aug 2026
Annual Comprehensive Maintenance Service Contract Charges for preventive maintenance, Repairs & Servicing of 4 KVA to 6 KVA On-Line UPS systems with Battery Bank maintenance and inclusive of all spares cost for Replacement of During AMC period such as Charger PCB, SCRs, IGBTs, Inverter PCBs, fuses, MCBs, etc., Complete. (except Batteries, DC Filter capacitors 100 Mfd / 100VDC or above, Transformers & Chokes etc). (i.e., 2 No(UPS)X 3 Years = 6 Nos) (i.e., 1 Nos (UPS) X 2 Years = 2 Nos)
Annual Comprehensive Maintenance Service Contract Charges for preventive maintenance, Repairs & Servicing of 7.5 KVA to 10 KVA On-Line UPS systems with Battery Bank maintenance and inclusive of all spares cost for Replacement of During AMC period such as Charger PCB, SCRs, IGBTs, Inverter PCBs, fuses, MCBs, etc., Complete. (except Batteries, DC Filter capacitors 100 Mfd / 100VDC or above, Transformers & Chokes etc). (i.e., 9 Nos (UPS) X 3 Years = 27 Nos)
Annual Comprehensive Maintenance Service Contract Charges for preventive maintenance, Repairs & Servicing of 15 KVA to 20 KVA On-Line UPS systems with Battery Bank maintenance and inclusive of all spares cost for Replacement of During AMC period such as Charger PCB, SCRs, IGBTs, Inverter PCBs, fuses, MCBs, etc., Complete. (except Batteries, DC Filter capacitors 100 Mfd / 100VDC or above, Transformers & Chokes etc). (i.e., 2 Nos (UPS) X 3 Years = 6 Nos) (i.e., 1 Nos (UPS) X 2 Years = 2 Nos)
Annual Comprehensive Maintenance Service Contract Charges for preventive maintenance, Repairs & Servicing of 25 KVA to 30 KVA On-Line UPS systems with Battery Bank maintenance and inclusive of all spares cost for Replacement of During AMC period such as Charger PCB, SCRs, IGBTs, Inverter PCBs, fuses, MCBs, etc., Complete. (except Batteries, DC Filter capacitors 100 Mfd / 100VDC or above, Transformers & Chokes etc). (i.e., 7 Nos (UPS) X 3 Years = 21 Nos))
Annual Comprehensive Maintenance Service Contract Charges for preventive maintenance, Repairs & Servicing of 60 KVA to 75 KVA On-Line UPS systems with Battery Bank maintenance and inclusive of all spares cost for Replacement of During AMC period such as Charger PCB, SCRs, IGBTs, Inverter PCBs, fuses, MCBs, etc., Complete. (except Batteries, DC Filter capacitors 100 Mfd / 100VDC or above, Transformers & Chokes etc). (i.e., 1 No(UPS) x 3 Years =3 Nos))
Only Labour / Engineering Supervision Service Charges for dismantling, shifting one place to another place in same city and Re- installation work UPS Systems with battery Bank
Supply and fixing of DC filter capacitors 2.5Kmfd to 10Kmfd 100 to 250V DC 1 set (3Nos) 72V to 192V DC operating system 3 to 10KVA On-Line UPS system.
Supply and fixing of DC filter capacitors 2.5Kmfd to 10Kmfd 1 set (3Nos) 120V to 400V DC operating system 10 to 30KVA On-Line UPS system.
Annual Comprehensive Maintenance Service Contract Charges for Preventive Maintenance, Repairs & Servicing of APFC Capacitor Panel (Capacitor Duty Contactor type) 100 to 200 KVAR and Inclusive of all Spares Cost for Replacement of During AMC Period, Such as timers contactors, fuses, indicators, MCBs, Capacitor Duty contactors etc., complete. (Except APFC relay, Capacitors, 100A and above main incomer MCCB / SFDU switch etc.) (i.e., 2 Nos X 3 Years =6Nos )
Annual Comprehensive Maintenance Service Contract Charges for Preventive Maintenance, Repairs & Servicing of APFC Capacitor Panel 100 to 200 KVAR (Capacitor Duty Thyreistor contactors type) inclusive of all Spares Cost for Replacement of during AMC Period, Such as timers, contactors, fuses, indicators, MCBs, Capacitor Duty Thyristor contactors etc., complete (Except APFC relay, Capacitors, 100A and above main Incomer MCCB / SFDU switch etc.) (i.e., 1 No X 3 Years = 3 Nos )
Supply 12 Stage APFC Relay for APFC Panels, Visa, Baulk or Reputed make.
Supply of LT PF Heavy Duty 3 Phase 440V capacitors cylindrical Type
Supply & Fixing of 3 pole MCCB 250 Amps 35KA suitable for APFCC panel.
Annual Comprehensive Maintenance Service Contract Charges for Preventive Maintenance, Repairs & Servicing of AMF Panels (Application to DG Set 100KVA to 750KVA) and inclusive of all Spares Cost for Replacement of During AMC Period, Such as timers, Contactors, fuses, indicators, MCBs, etc, complete (Except AMF Relay, 100A and above main incomer contactors / MCCB / ACB switch etc.) (i.e., 4 Nos X 3 Years = 12 Nos)
Supply & Fixing of AMF relay suitable for AMF Panel of 100 to 750 KVA DG Set.
Supply of 3 Pole 110 Amps Power Contactor
Supply of 3 Pole 250 Amps Power Contactor
Supply and Testing of AVR suitable for 100 - 500KVA DG set Alternator
Supply and fixing of 12V 180 AH Lead Acid Exide battery XP-1800 / equivalent for DG set with 3 years warranty including wire leads, connections etc complete.
Overhauling servicing charges for 3/4 Pole ACBs 600 Amps to 2000 Amps
Supply of 24V 20 Amps Battery Charger Working Voltage 230V AC with battery Reverse & Over load / Short circuit protection without Volt / Ammeter.
Supply of 50 Sqmm copper flexible multi stand single core cable 2 Mtrs with suitable +/- terminals (4 Nos.) & copper lugs (2 Nos.) etc., for DG Set start motor to battery.
Supply and fixing of 12V 26 AH SMF battery with 3 years Warranty, including wire leads ,connections etc complete. Makes: Quanta / Racket / Exide.
Supply & Fixing of 12V 42Ah SMF SMF battery with 3 years Warranty, including wire leads ,connections etc complete.Makes: Quanta / Racket / Exide.
Supply and fixing of 12V 65 AH SMF battery with 3 years warranty including wire leads ,connections etc complete.,Makes: Quanta / Racket / Exide.
Supply and fixing of 12V 100 AH SMF battery with 3 years warranty including wire leads, connections etc complete.,Makes: Quanta / Racket / Exide
Supply installation Testing and commissioning of ....3.... KVA 72/96 VDC on line UPS system confirms to IS 16242(Part-I):2014 and IEC 60240-1 : 2008 with IGBT technology pure sine wave out put, double conversion with auto and manual static by pass switch single phase input / Single phase output. Makes: Numeric/APC/Fuji Electric/ Sakshham /Emerson
Supply installation Testing and commissioning of ....6.0 KVA , 192/240 VDC with Isolation Transformer on line UPS system confirms to IS 16242(Part-I):2014 and IEC 60240-1 : 2008 with IGBT technology pure sine wave out put, double conversion with auto and manual static by pass switch single phase input / Single phase output. Makes: Numeric/APC/Fuji Electric/ Sakshham /Emerson
Supply installation Testing and commissioning of ...10.0 KVA , 192/240 VDC with Isolation Transformer on line UPS system confirms to IS 16242(Part-I):2014 and IEC 60240-1 : 2008 with IGBT technology pure sine wave out put, double conversion with auto and manual static by pass switch single phase input / Single phase output. Makes: Numeric/APC/Fuji Electric/ Sakshham /Emerson
Purchase cost for old life over (failure) existing batteries any make any model under buyback offer.
Note: (1) The above rates are basic prices excluding GST and applicable GST will be reimbursed / paid as per actuals on production of proof. (2) The bidders are requested to quote the Tender percentage excluding GST. (3) Statutory deductions will be made as per norms, if applicable. Any modalities imposed on GST by the Government from time to time, the same will be implemented
(Rupees Thirty eight Lakhs three thousand two hundred thirty one and Paise thirty eight only)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
NIT 27 BOQ.xlsx
TENDER_DOCUMENT • 0.02 MB
NIT 27 Conditions.doc
TENDER_DOCUMENT • 0.50 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].