| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.5 LAccepted-AOC | L1 | Accepted-AOC Being L1 and reasonable | |
| 2 | L2₹17.4 L+₹1.6 L (9.84%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹19.9 L+₹4.1 L (25.8%)Rejected-Finance AMBEDKAR PARK AND RAWAT PG HOUSE WARD NO 10 KHASRA NO 2435 DEHRADUN UTTARAKHAND 248 140 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248140 | L3 | Rejected-Finance Being other than L1 | |
| 4 | Rejected-Technical B1 2 ALANKAR PLAZA CENTRAL SPINE VIDHYADHAR NAGAR JAIPUR RAJASTHAN 302039 | JAIPUR | RAJASTHAN | 302039 | - | Rejected-Technical not meeting the eligibilty criteria |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
18 Jun 2024, 6:00 pmClosed
GE Pithoragarh
GE Pithoragarh Post - Bharkatiya Pithoragarh - 262520
REPAIR / MAINT OF DG SETS INCLUDING INSTALLATION OF RETROFIT EMISSION CONTROL DEVICE AND CONNECTED ITEMS OF WORK AT MIL STN PITHORAGARH.
2024_MES_655010_1
8608/PGH/E8
Open Tender
Civil Works
Item Rate
180 days
Pithoragarh
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE Pithoragarh
₹40,000
Yes
13 Sept 2024
20 May 2024
25 Jun 2024
20 May 2024
18 Jun 2024
4 Jun 2024
21 May 2024 - 25 May 2024
Amount
DESCRIPTION OF ITEMS
Maintenance and complete servicing of existing DG Set of capacity 20/25/30/40 KVA including replacement of filters,dis -assembling of operating mechanism / parts, well cleaning with chemicals, replacing unserviceable parts / assessories, oiling / greasing of complete moving parts, calibration and resetting of governer by the rep of reputed manufacturer, cleaning of injector nozzle, cleaning/descaling of radiator assembly with cleaning agent, removal of all deposited materials including oiling / greasing of exhaust fan & bearing etc. including re - assembling the DG set after replacing the unserviceable parts and components etc. and making DG Set in perfect operational in manual and electrical mode, complete all as directed including testing of DG Set at full load. Note:- (i) Spare parts will be measured and paid seperately under respective items of Sch 'A'. (ii) Make of parts shall be same as per existing make.
Supply only the following spare part of existing make & size, suitable for DG Set 30/20 KVA complete in all respect & as directed. :- (a) Rubber hose pipes with fixing clamps
(b) Lubrication oil filter
(c) Fuel filters
(d) By Pass filters (as per sample)
(e) Fuel pipe duly covered with supper fine steel wire with coupling , nut and bolts.
(g) Engine gasket.
(h) Lubrication Oil, Make - Castrol Servo.
(J) Air filter
(k) Replacement of Hose: Air Cleaner.
(l)Replacement of Gasket: oil filter
Maintenance and complete servicing of existing DG Set of capacity 200 KVA including replacement of filters,dis-assembling of operating mechanism / parts, well cleaning with chemicals, replacing unserviceable parts / assessories, oiling / greasing of complete moving parts, calibration and resetting of governer by the rep of reputed manufacturer, cleaning of injector nozzle, cleaning/descaling of radiator assembly with cleaning agent, removal of all deposited materials including oiling / greasing of exhaust fan & bearing etc. including re - assembling the DG set after replacing the unserviceable parts and components etc. and making DG Set in perfect operational in manual and electrical mode, complete all as directed. Note:- (i) Spare parts will be measured and paid seperately under respective items of Sch 'A'. (ii) Make of parts shall be same as per existing make
Supply only the following spare part of existing make & size, suitable for DG Set 200 KVA complete in all respect & as directed. :- (a) Rubber hose pipes with fixing clamps
(b) Lubrication oil filter
(c) Fuel filters
(d) By Pass filters (as per sample)
(e) Fuel pipe duly covered with supper fine steel wire with coupling , nut and bolts.
(f) Fan belt (as per sample) Make:- Fanner
(g) Engine gasket.
(h) Lubrication Oil, Make - Castrol Servo.
(J) Air filter
(k) Replacement of Hose: Air Cleaner.
(l)Replacement of Gasket: oil filter
(m)Replacement of display
Maintenance and complete servicing of existing DG Set of capacity 160 KVA including replacement of filters,dis -assembling of operating mechanism / parts, well cleaning with chemicals, replacing unserviceable parts / assessories, oiling / greasing of complete moving parts, calibration and resetting of governer by the rep of reputed manufacturer, cleaning of injector nozzle, cleaning/descaling of radiator assembly with cleaning agent, removal of all deposited materials including oiling / greasing of exhaust fan & bearing etc. including re - assembling the DG set after replacing the unserviceable parts and components etc. and making DG Set in perfect operational in manual and electrical mode, complete all as directed including testing of DG Set at full load. Note:- (i) Spare parts will be measured and paid seperately under respective items of Sch 'A'. (ii) Make of parts shall be same as per existing make.
Supply only the following spare part of existing make & size, suitable for DG Set 160 KVA complete in all respect & as directed. :- (a) Lubrication oil filter
(b) Fuel filters
(c) By Pass filters (as per sample)
(d) Lubrication Oil, Make - Castrol Servo.
(e) Air filter
(f) Replacement of Hose: Air Cleaner.
(g)Replacement of Gasket:oil filter
Maintenance and complete servicing of existing DG Set of capacity 125 KVA including replacement of filters,dis -assembling of operating mechanism / parts, well cleaning with chemicals, replacing unserviceable parts / assessories, oiling / greasing of complete moving parts, calibration and resetting of governer by the rep of reputed manufacturer, cleaning of injector nozzle, cleaning/descaling of radiator assembly with cleaning agent, removal of all deposited materials including oiling / greasing of exhaust fan & bearing etc. including re - assembling the DG set after replacing the unserviceable parts and components etc. and making DG Set in perfect operational in manual and electrical mode, complete all as directed including testing of DG Set at full load. Note:- (i) Spare parts will be measured and paid seperately under respective items of Sch 'A'. (ii) Make of parts shall be same as per existing make.
Supply only the following spare part of existing make & size, suitable for DG Set 125 KVA complete in all respect & as directed. :- (a) Rubber hose pipes with fixing clamps
(b) Lubrication oil filter
(c) Fuel filters
(d) By Pass filters (as per sample)
(e) Fuel pipe duly covered with supper fine steel wire with coupling , nut and bolts.
(f) Fan belt (as per sample) Make:- Fanner
(g) Engine gasket.
(h) Lubrication Oil, Make - Castrol Servo.
(J) Air filter
(k) Replacement of Hose: Air Cleaner.
(l)Replacement of Gasket: oil filter
(m)Replacement of display
(n)Replacement of sensor
M & L for servicing /cleaning of ball bearing of altornator by cleaning agent ,cleaning the slip rings,adjustment of carbon bushes, greasing the ball bearings , refittings and alignments of complete altornator with engine for smooth functioning complete all as specified and directed.
M & L for servicing of DG Set 200 dynamo 12 V assemblly including replacement of worn out armature ,union, carbon bush complete and refixing all the component in existing position with necessayy screw, nuts and bolts for smooth and efficient functioning all as specified and directed.
M & L for servicing of DG Set125 dynamo 12 V assemblly including replacement of worn out armature ,union, carbon bush complete and refixing all the component in existing position with necessayy screw, nuts and bolts for smooth and efficient functioning complete all as specified and directed.
Decanning of diesel oil from diesel tank more then 500 ltrs capacity in empty barrel, dismantling of inlet & outlet fuel connection, removing all deposited material from bottom, cleaning the diesel tank with K'oil, scraping of old paint from outer side of tank and applying two coats of synthetic enameled paint on outer surfaces of tank, marking & painting of oil levels on tank, making inlet and outlet connection , re-filling of decanned diesel in the tank complete all as specified and directed.
Decanning of diesel oil from diesel tank of 20 to 200 ltrs capacity in empty barrel, dismantling of inlet & outlet fuel connection, removing all deposited material from bottom, cleaning the diesel tank with K'oil, scraping of old paint from outer side of tank and applying two coats of synthetic enameled paint on outer surfaces of tank, marking & painting of oil levels on tank, making inlet and outlet connection , re-filling of decanned diesel in the tank all as directed.
Decanning of diesel oil from diesel tank of 200 to 500 ltrs capacity in empty barrel, dismantling of inlet & outlet fuel connection, removing all deposited material from bottom, cleaning the diesel tank with K'oil, scraping of old paint from outer side of tank and applying two coats of synthetic enameled paint on outer surfaces of tank, marking & painting of oil levels on tank, making inlet and outlet connection , re-filling of decanned diesel in the tank all as directed.
M & L for painting of complete DG Set of capacity 200 KVA by means of scraping old paints preparing the surface for painting with requisite tools then painting the DG Set with two coats ofsuper enemal paint as per existing colour once a coat of red oxide paint over spray gun or by brush as terible including rewriting of srl No. & MES No.in two inch block letter all as per specified and directed by Engr-in-Charge.
M & L for painting of complete DG Set of capacity 125 KVA by means of scraping old paints preparing the surface for painting with requisite tools then painting the DG Set with two coats ofsuper enemal paint as per existing colour once a coat of red oxide paint over spray gun or by brush as terible including rewriting of srl No. & MES No.in two inch block letter all as per specified and directed by Engr-in-Charge.
M & L for painting of complete DG Set of capacity 30/20 KVA by means of scraping old paints preparing the surface for painting with requisite tools then painting the DG Set with two coats ofsuper enemal paint as per existing colour once a coat of red oxide paint over spray gun or by brush as terible including rewriting of srl No. & MES No.in two inch block letter all as per specified and directed by Engr-in-Charge.
Replacement of external battery chargering unit suitable for 2x12 Volt 95/150/185 AH battery capacity complete all as directed and approved by Eng-in-charge.
S&F in replacement of Auto Voltage Regulator ( AVR) suitable for DG set of capacity 10 KVA to 25 KVA complete all as specified and directed.
S&F in replacement of Auto Voltage Regulator ( AVR) suitable for DG set of capacity 125 KVA to 200 KVA complete all as specified and directed.
S&F in replacement of solonoid switch suitable for existing DG set of capacity 125 KVA to 200 KVA complete all as specified and directed.
S&F in replacement of solonoid switch suitable for existing DG set of capacity 10 KVA to 25 KVA complete all as specified and directed.
M&L for earthing complete with galvanised or steel earth plate electrode of size 60cm x60cmx6mm thick burried directly in ground vertically ( to a depth not less than 2.25mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to strip 32x 6 mm size with nuts, bolts , check nuts , washers, earth plate surrounded by packed layers of charcoal dust and common salt 15cm thick all around, top & bottom watering pipe 20mm bore of GI medium grade with funnel and wiremesh all as shown in electrical plate No. 5 of SSR -1991 Part I and connecting to arthing test point,main switch board and testing on completion including PCC chamber concrete 1:3:6 type C-2 and RCC cover 75mm thick with MS TMT bar 8mm dia @ 150mm c/c both ways in cement concrete(1:2:4) type B-1 all asshown in electrical plate in No 5 of SSR(Pt-I)1991 complete all as specified and dirfected by Engineer-in-charge.
Supply and fixing/laying of galvanized iron strip of size 32x6 mm as earth continuity conductor provided in between earth test point terminal and upto the equipment incl nuts, bolts and washers complete all as specified and directed.
S&F indicating lamp assembly (LED) Red, green, yellow, blue and making necessary connection including taking down existing unserviceable indicating lamp assembly, complete all as directed.
Supply only the following items / material, complete all as directed (a).Cotton waste white
(b) Caustic soda
(c) Distilled water (1 ltr bottle)
(d) Coolant
(e) Copper battery leads, 1.5 m long
(f) Copper battery terminals
(g) Copper battery leads, 0.80 m long
S&F rubber insulating mat suitable for LT 1100 Volts of size 1 MtrX2 MtrX10 mm thick complete all as specified and directed.
Supply and fixing in Replacement Battery 12V 100 Ah including testing complete all as directed by Engr-in- charge.
Supply and fixing in Replacement Battery 12V 70 Ah including testing complete all as directed by Engr-in- charge.
S&F MCCB 4 pole 100 Amps with breaking capacity 16 KA 415 volt & elect connection etc completeall as specrfied and directed.
S/F MCCB 4 pole 160 Amps with breaking capacity 25 KA 415 volt & elect connection etc completeall as specrfied and directed.
S/F MCCB 4 pole 250 Amps with breaking capacity 25 KA 415 volt & elect connection etc completeall as specrfied and directed.
S&F MS chequarred Plate cover 10 mm thickness for cable duct including 2 coats of synethic enamel paint over a coat of red oxide primer complete all as specified & directed.
S&F of TPN off load change over switch of capacity 400 Amp including dismantling of existing complete all as specified and directed by Engr-in-charge.
Dismantling of existing change over switch including disconnection and connection of LT cable complete and supply fixing of offload change over switch of capacity 200 Amp TPN with enclosure box including handle and other accessories complete all as specified and directed.
Excavation in trenches in any type of soil n.exc. 1.5 mtr wide and n.exc 1.5 mtr in depth for LT cables complete including bricks all as specified & directed.
Returning, filling in, any type of soil and spreading in layers n. exc 25cm thick each layer including watering & well ramming complete all as specified& directed.
Removal of surplus soil to a distance n.exc 50 mtr & depositing where directed at a level n. exc. 1.5mtr above the starting point complete all as specified & directed.
M & L for brick protection to cable using old size sub class 'B' bricks, laidflat, dry butt jointed, laid lengthwise perpendicular to the axis of cable all as specified & directed.
M&L for sand cushioning with layer of sand 8 cm thick before laying of cable and 15 cm after lying of calbe in trenches complete all as specified & directed.
Supply and laying XLPE insulated , armoured heavy duty electric cable with alumnium conductor ,1100 volts grade ,corss sectional area 120 sqmm 3.5 core complete all as specified and directed by Engr-in-Charge.
All as per ser item No. 36 here-in-before but 150 Sqmm 3½ core complete all as specified and directed.
All as per set item No.36 here-in-before but 185 Sqmm 3½ core complete all as specified and directed.
All as per set item No. 36 here-in-before but 240 Sqmm 3½ core complete all as specified and directed.
S & F in replacement GI pipe light grade 100mm bore for cable protection, fixed to pole/ alongwall/ floor/ under road/ across the drain or nallaha etc complete all as specified & directed.
M & L in repair for factory fabricated bus bar chamber outdoor type water vermin proof of size 600x400x250 mm duly provided with front openable door and PU(Polyurethene + Isocyanides) formed Gaskets with IP-66 protection rubber gasket housed with TPN aluminium bus bar on porcelain insulated with the bus bar size of 350x40x5 mm for phases and neutral incl making connections, cable entry/exit holes with front door locking arrangements and busbar panel shall be pedestal type and provided with four nos of angle iron supports duly embedded in foundation and complete bus bar chamber shall be CRCA type powder coated.
Maintenace and complete servicing of AMF Panel of any size all as specifed and directed.
S & F electric shock treatment chart on flex/pvc reflecting sheet with of size 50x100 cm complete all as specified and directed
Supply, installation, testing & commissioning of Retrofit Emission Control Device (RECD) automatic type for reducing DG Emission, Stainless Steel as per latest CPCB guidelines suitable for DG set of capacity 125 KVA with following components:-
(a) DG range - 125 KVA (b) Technology of RECD - Wet Scrubber / ESP (Electrostatic precipitation) / Catalytic Conversion (c) Filter less system (d) No noise level (e) Particulate matter capturing efficiency - Min 70% (f) By product disposal cope - Should in vendor scope (g) Particular size captured - PM 2.5 (h) Actuation Type - Electrostatic (j) Cleaning system - Automatic (k) Material of construction (outer body ) - Powder coated mild steel (l) Material of construction inner cell - SS-304 (m) Insulation on emission device - Glass wool (n) Back pressure on engine - No back pressure ( Should be less than 10 Kpa ) and static pressure less than 1 Kpa (o) Testing requirements post installation at site (p) There should not be any Bypass arrangement in RECD to let the pollutants bypass the RECD on any account Contd.....
Note : (a) Retrofit Emission Control Device (RECD) shall be of any of the Makes:- M/s P I Green Innovations Pvt Ltd, M/s Platino Automative Pvt Ltd, M/s Chakr Innovation Pvt Ltd, M/s Automoto Genset Solutions LLP, M/s Vasthi Instruments Pvt. Ltd., M/s Maxmoc Motor Works India Pvt Ltd. (b) All the aux materials required for installation at site including field piping fabrication & erection , civil foundation design & execution (if required),painting etc shall be provided by the contractor and included in quoted rate. (c) the device must be tested by one of the five currently CPCB recognized / Approved laboratories:- (i) Automatic research association of India , Pune ( Maharashtra ) (ii) International centre for automotive technology , Manser (Haryana) (iii) Indian Oil corporation , Research and development centre Faridabad (Haryana) (iv) Indian institute of Petroleum , Dehradun (Uttrakhand) (v) Vehicle Research Development Establishment , Amednagar (Maharashtra )
Note : Tenderers may note that amount of credit Rs 33,697.00 will be deducted from the total amount arrived, at the time of Acceptance of contract.
kumaon and hills strument engnering services
S.K ASSOCIATE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .