Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance CHANDMARI WARD NO 19 PO PS TEZPUR DIST SONITPUR ASSAM | SONITPUR | ASSAM | 784001 | Admitted-Finance |
| 2 | Admitted-Finance NO 3 WD BUILDING JP AGARWALLA ROAD BHARALUMUKH KAMRUP ASSAM 781009 UDYAM AS 03 0009483 | KAMRUP METRO | ASSAM | 781009 | Admitted-Finance |
| 3 | Admitted-Finance 7TH MILE UPPER SHILLONG P O NONGLYER SHILLONG 793009 MEGHALAYA | EAST KHASI HILLS | MEGHALAYA | 793009 | Admitted-Finance |
Tender Value
₹26.8 L
EMD Value
₹53,600
Closing Date
24 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (N) TEZPUR
GE (N) TEZPUR
REPAIR / REPLACEMENT AND MAINTENANCE TO LT OVERHEAD LINES AND CONNECTED ITEMS IN ZONE 7, 8 9 AT NAA UNDER GE (NORTH) TEZPUR
2020_MES_372087_1
GE(N)/TEZ/2020-21/8430
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
TEZPUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (N) TEZPUR
₹53,600
Yes
2 Nov 2020
26 Sept 2020
27 Oct 2020
26 Sept 2020
24 Oct 2020
12 Oct 2020
26 Sept 2020 - 10 Oct 2020
60 days
Amount
Note 1: (Applicable for all parts/items) : The bidders/contractors are advised to read tender document, all drawings & all corrigendum/amendments and general condition of contracts before entry/quoting the rates. Note 2:- Attention to bidder is hereby invited to upload revised BOQ if published during their bid submission. Uploading of incorrect/ pre-revised BOQ shall be treated as non bonafide and rejected. Fixed credit has been given in technical documents which shall be taken into account during acceptance of bid/tender.
Taking down down/dismantling old/rusted/broken steel poles/struts,removing from site and making good disturbed surface complete all as specified and directed.
Taking down down/dismantling old/rusted/deshaped cross arms/MS channel or angle for reuse complete all as specified and directed.
Dismantling insulators any type, any size including setting aside serviceable and removal of rubbish material complete all as specified and directed.
Dismantling of ACSR conductors of any description,stacking serviceable conductor aside for reuse and removing unsv/broken conductor complete all as specified and directed.
Taking down down/dismantling old/broken stay assembly complete including demolition of concrete, etc. and excavation complete all as specified and directed.
Dismantling /taking down old rusted /broken GI earth wire from feeder or distributor span complete all as specified and directed.
Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr depth in soft / loose soil and getting out for removing / laying of pipe /Cables etc complete all as specified.
Returning, filling in , including spreading, levelling, watering and well ramming in layer not exceeding 25 cm thick in soft/oose soil complete all as specified and directed.
Removing excavated material (soil) not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the strating point complete all as specified and directed.
M&L for river sand, washed and screened dry for cushioning to under ground cable in tenches below and around under ground cable including spreading and levelling complete as specified and directed.
M&L laying well burnt old size bricks, sub calss "B" bricks, straight or curved on plan, laid flat with width equal to length of brick, laid dry over electric cablefor protection all complete all as specified and directed.
M&L for Boring/Drilling (Horizontally) manually/mechanically under existing road (Maximum 10 M in width) suitable for passing GI tubing of 40 to 80 mm bore complete all as specified and directed.
M&L Mild steel cross arms, bracings, supports, clamps, and back plates fabricated from structural steel sections including nut, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed including preparation of surfaces and applying two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
Fixing only mild steel cross arms, bracings, supports, clamps, and back plates obtained vide item N0- 2 here-in-bebore, including nut, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed including preparation of surfaces and applying two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
M&L for aluminium conductor,steel reinforced (ACSR) of any size, stringing properly on insulators on pole and binding with aluminium tape / binding with conductors, jumpers etc including dismantling and taking down old unserviceable ACSR conductor complete all as specified and directed.
M&L for Supplying, transporting, erecting in truely vertical steel tubular swaged poles type 410 SP-31 (9.0 metres long) complete with cast iron base plate, finial, taper plug, bolts,nuts and screws as specified, including necessary excavation and earth work, PCC 1:4:8 type D2 in foundations below pole, PCC 1:3:6 type C1 as in plinth block and coping, disposal of surplus soil to a distance not exceeding 50m and depositing where directed, painting of exposed surface of steel tubular poles with two coats of Aluminium paint over one coat of red oxide primer and providing 300 mm wide bands (3 bands/ straps with synthetic enamel paint and 2 bands with Black bituminous paint) from plinth block and numbering of poles, painting embedded portion of poles with one coat of bituminous paint complete all as specified and directed.
Restringing of LT overhead lines comprising ACSR conductors of any size from 04 conductors to 07 conductors after opening from insulators, including restringing same and winding on insulator with proper size of binding wire upto permissible sag complete all as specified and directed.
Restringing of LT overhead lines comprising ACSR conductors of any size From 08 conductors to 10 conductors after opening from insulators, including restringing same and winding on insulator with proper size of binding wire upto permissible sag complete all as specified and directed.
S&F (in repairs) guarding Cradles, hexagonal/ rectangular,fabricated with galvanised steel wire 4 mm dia on LT pole including binding with 14SWG MS wire complete all as specified and directed.
S&F (in repair) Insulator Pin type, povrcelain, vitreous, white, brown or green, insulator including one galvanised mild steel spindle, two galvanised iron washres and one glavanised iron nut, 100 mm height, 65 mm die. For 1100 volts grade complete all as specified and directed.
S&L in repair of shackle type Insulator porcelain vitreous white/ brown or green, 75 mm high and 90mm dia suitable for working pressure of 1100 Volt including Galvanized iron straps of size (31x3) mm ,nut, bolt of dia 12 mm and washers of suitable size, complete all as specified and directed.
S&F (in repairs) Stay Assembly comprising of 7/2.24mm galvanised MS stranded wire of rquired length fixed to pole with and including flat iron clamps fabricated out of 50x6mm flat iron and nuts,bolts & washers of suitable size, 40cms long 14mm dia galvanised MS stay bow, 215cms long 20mm dia stay rod with threaded end including bolts & washers, MS stay plate galvanised 230x230x6mm, two thimbles,loop type insulator of size 65x90mm with clearance dia of hole 20mm including necessary excavation, earth work and PCC 1:4:8 type D2 using 40mm stone aggregate complete all as specified and directed.
M&L for connecting service cable 2 core 10 sqmm 1100 volts grade heavy duty flat or circular PVC insulated aluminum multistranded conductor served with inner sheathing of PVC and overall PVC sheathed on service connection suspended by insulated hangers not more than 1 mtr apart including 4mm dia suspended GI wire complete all as specified and directed.
M&L for Supplying, laying or fixing, jointing and testing LT under ground electric power cable Crossed linked polyethylene (XLPE Cable) insulated, galvanised steel strip or wire armoured, ISI-7098 Mark, with aluminium conductor multi stranded, heavy duty 1100 Volts grade of following sizes, complete all as specified laid in trenches / laid under floor or fixed naked with walls/ on poles/ in ducts / in GI pipes etc. complete all as specified and directed. (Note :- Excavation, earth work, sand cushioning, protection bricks/ tiles / block, Clamps, nuts, Bolts, washres and pipe shall be measured and paid separately under relevant items).
16 Sq mm cross sectional area, 4 core.
25 Sq mm cross sectional area, 4 core.
35 Sq mm cross sectional area, 3½ core.
50 Sq mm cross sectional area, 3½ core.
70 Sq mm cross sectional area, 3½ core.
95 Sq mm cross sectional area, 3½ core.
120 Sq mm cross sectional area, 3½ core.
150 Sq mm cross sectional area, 3½ core.
185 Sq mm cross sectional area, 3½ core.
240 Sq mm cross sectional area, 3½ core.
300 Sq mm cross sectional area, 3½ core.
Trimming of tree branches touching to LT / HT OH lines not exceeding 30 cm girth, shrub, vegetation, bush and saplings at least upto 5.0 M from outer edge of ACSR including cleaning of road/path/fencing etc complete all as specified and directed.
M&L for painting of steel tubular swaged poles of LT over head line 9 M long complete including all MS chanel mounted/fixed with pole, earth protection & water pipe (if exists) with two coat of aluminium paint and providing 05 Nos bands/ straps with synthetic enamel paint (black and yellow 30 cm wide each) from top of plinth block and numbering of poles with white synthetic enamel paint on black circular background complete all as specified and directed.
M&L for painting to RCC pole 8.5/9.00 metre long after scrapping of old painted surfaces and applying two coats of cement based paint up to 1.20 metre height from ground level in 30 cm alternative black and yellow strips and remaining portion including MS frames like channel,clamps, angle, D-clamps etc with two coats of synthetic enamel paint of suitable colour complete all as specified and directed.
S&F in repairs Galvanised mild steel tubing, 'Light grade' of following bore complete with all fittings, laid in trenches/ under roads, drain , paths, fixed to poles/ walls with Mild steel clamps, bolts, nuts and washerws complete all as specified of the following bore (Note :- Excavation & Earth work shall be measrued and paid separately)
50 mm bore
80 mm bore
M&L for line separator PVC type with clamp including fixing with overhead lines of multi conductor of ACSR as and where directed to prevent short circuiting of phase/neutral conductors mutually complete all as specified and directed of following ways:-
Line separator 2way
Line separator 3 way
M&L for disconnecting burnt end or portion of cables any size,taking out burnt end of cable including heat up aluminium lugs and preparing fresh ends and connecting with following sizes aluminium lugs/thimbles including necessary jointing material such as nuts,bolts & wahshers of requisite size and insulating with colour coded tape all as required at site complete all as specified and directed of the following size:-
Aluminium lug 10-25 sqmm
Aluminium lug 35 sqmm
Aluminium lug 50 sqmm
Aluminium lug 70 sqmm
Aluminium lug 95 sqmm
Aluminium lug 120 sqmm
Aluminium lug 120-300 sqmm
Materials and Labour for Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge of the earth plate at a depth not less than 1.5M below normal ground level connected to GI wire 4mm by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 54 cm x 54 cm x 5 cm (Reinforced with 8 mm dia. TMT bars @ 150 mm, center to center both ways) with one handle for lifting made out of 8 mm dia. MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 15 mm bore galvanized steel tubing light grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown on electrical plate No 3 of SSR Part-I (2009) complete as specified and directed complete all as specified and directed.
M&L for Cleaning of electric substation by uprooting unwanted grass, bushes and trimming of branches, surface dressing not exc.15cms deep in loose/soft soil to cut the grass,throne busehs and other any type of grass upto root level surrounding the installation and depositing the same at nearby garbage pit, refreshing and re-spreading aggregates inside the premises of sub station if any including cleaning of road/path/fencing etc, maintenance of transformer platform all as specified and directed.
MAHANTA ENTERPRISES
S K ENTERPRISE
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .