Tender Value
Refer Docs
EMD Value
₹2.7 L
Closing Date
1 Dec 2026, 3:00 pm5d left
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Vadodara Division: Electrical works in connection with various works under Plan Heads 30, 42 and 53 Anand, Gothangam, Kim and Coach Care Centre, Pratapnagar.
BRC-EL-P-27-26-27~WR
BRC-EL-P-27-26-27
Open
Works - General
12 Months
Vadodara, Gujarat
₹0
₹2.7 L
4 Nov 2026
4 Nov 2026
17 Nov 2026
60 days
139 items across 3 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,07,37,465 | ||
| — | 180.00 | — | — | ||
| Wiring of light/fan/exhaust fan/common light points in concealed manner with modular accessories - The price shall cover for concealed wiring of light/fan/exhaust fan point with 1.5 sq. mm PVC insulated, unsheathed, multi-stranded, FRLS copper conductor of 1100 Volt grade, ISI marked, conforming to IS: 694/1990 with 1.0 sq. mm PVC insulated, unsheathed, multi-stranded, FRLS copper conductor of 1100 Volt grade, ISI marked, conforming to IS: 694/1990 as earthing wire with all accessories in concealed type of wiring in medium grade PVC conduit with all accessories. The accessories shall be of modular type. | — | — | — | 71,640 | |
| — | 30.00 | — | — | ||
| Providing plug point, 6 Amp in concealed manner on existing board with modular accessories - The price shall cover for providing plug point with modular type universal socket and switch, 6 Amp, 230 Volt, AC on existing board. The accessories shall be of modular type. | — | — | — | 2,850 | |
| — | 35.00 | — | — | ||
| Providing board with two switches and two sockets, 6 Amp in concealed manner with modular accessories - The price shall cover for providing multi-plug point board (switch, 6 Amp - 2 Nos and universal socket, 6 Amp - 2 Nos) with modular type universal five-pin socket and switch, 6 Amp, 230 Volt, AC with modular accessories. The accessories shall be of modular type of. The price shall also cover for concealed wiring of board with 1.5 sq. mm, PVC insulated, unsheathed, multi-stranded, FRLS copper conductor of 1100 Volt grade, ISI marked, conforming to IS: 694/1990 with 1.0 sq. mm, PVC insulated, unsheathed, multi-stranded, FRLS copper conductor of 1100 Volt grade, ISI marked, conforming to IS: 694/1990 as earthing wire with all accessories in concealed type of wiring in medium grade PVC conduit with all accessories. | — | — | — | 7,805 | |
| — | 40.00 | — | — | ||
| Providing board with four switches and four sockets, 6 Amp in concealed manner with modular accessories - The price shall cover for providing multi-plug point board (switch, 6 Amp - 4 Nos and universal socket, 6 Amp - 4 Nos) with modular type universal five-pin socket and switch, 6 Amp, 230 Volt, AC with modular accessories. The accessories shall be of modular type. The price shall also cover for concealed wiring of board with 1.5 sq. mm, PVC insulated, unsheathed, multi-stranded, FRLS copper conductor of 1100 Volt grade, ISI marked, conforming to IS: 694/1990 with 1.0 sq. mm, PVC insulated, unsheathed, multi-stranded, FRLS copper conductor of 1100 Volt grade, ISI marked, conforming to IS: 694/1990 as earthing wire with all accessories in concealed type of wiring in medium grade PVC conduit with all accessories. | — | — | — | 17,360 | |
| — | 20.00 | — | — | ||
| Providing power plug point, 16 Amp in concealed manner on existing board with modular accessories - The price shall cover for providing power plug point with modular type universal socket and switch, 16 Amp, 230 Volt, AC on existing board. The accessories shall be of modular type. | — | — | — | 3,760 | |
| — | 20.00 | — | — | ||
| Providing power plug point, 16 Amp in concealed manner on separate board with modular accessories - The price shall cover for providing power plug point with modular type universal socket and switch, 16 Amp, 230 Volt, AC on separate board with modular accessories. The accessories shall be of modular type. The price shall also cover for concealed wiring of plug point with 2.5 sq. mm, PVC insulated, unsheathed, multi-stranded, FRLS copper conductor of 1100 Volt grade, ISI marked, conforming to IS: 694/1990 with 1.5 sq. mm, PVC insulated, unsheathed, multi-stranded, FRLS copper conductor of 1100 Volt grade, ISI marked, conforming to IS: 694/1990 as earthing wire with all accessories in concealed type of wiring in medium grade PVC conduit with all accessories. | — | — | — | 8,760 | |
| — | 850.00 | — | — | ||
| Concealed wiring of sub-main with 2.5 sq. mm copper wire, single-core in PVC conduit - The price shall cover for concealed wiring of sub main with two-wire single core 2.5 sq. mm PVC insulated, unsheathed, multi-stranded, FRLS copper conductor of 1100 Volt grade, ISI marked, conforming to IS: 694/1990 and one wire of 1.5 sq. mm PVC insulated, unsheathed, multi-stranded, FRLS copper conductor of 1100 Volt grade, ISI marked, conforming to IS: 694/1990 in concealed manner as per site requirement in PVC conduit. | — | — | — | 73,950 | |
| — | 150.00 | — | — | ||
| Concealed wiring of sub-main with 2.5 sq. mm copper wire, single-core in existing PVC conduit - The price shall cover for wiring of two wire sub-main with 2.5 sq. mm PVC insulated, unsheathed, multi-stranded, FRLS copper conductor of 1100 Volt grade, ISI marked, conforming to IS: 694/1990 with one wire of 1.5 sq. mm PVC insulated, unsheathed, multi-stranded, FRLS copper conductor of 1100 Volt grade, ISI marked, conforming to IS: 694/1990 in concealed manner as per site requirement in existing PVC conduit. | — | — | — | 10,650 | |
| — | 500.00 | — | — | ||
| Concealed wiring of sub-main with 4.0 sq. mm copper wire, single-core in PVC conduit - The price shall cover for concealed wiring of sub main with two-wire single core 4.0 sq. mm PVC insulated, unsheathed, multi-stranded, FRLS copper conductor of 1100 Volt grade, ISI marked, conforming to IS: 694/1990 and one wire of 2.5 sq. mm PVC insulated, unsheathed, multi-stranded, FRLS copper conductor of 1100 Volt grade, ISI marked, conforming to IS: 694/1990 in concealed manner as per site requirement in PVC conduit. | — | — | — | 52,500 | |
| — | 850.00 | — | — | ||
| Wiring of sub-main with copper wire, single-core, 4.0 sq. mm - 5 Nos and 2.5 sq. mm - 1 No in PVC conduit/casing-capping with junction box - The price shall cover for wiring of five wire sub-main with 4.0 sq. mm PVC insulated, unsheathed, multi-stranded, FRLS copper conductor of 1100 Volt grade, ISI marked, conforming to IS: 694/1990 with one wire of 2.5 sq. mm PVC insulated, unsheathed, multi-stranded, FRLS copper conductor of 1100 Volt grade, ISI marked, conforming to IS: 694/1990 in PVC casing-capping or medium grade PVC conduit of not less than 25 mm diameter, ISI marked as per site conditions with junction boxes at suitable intervals as per requirement. | — | — | — | 1,48,750 | |
| — | 100.00 | — | — | ||
| Wiring of sub-main with copper wire, single-core, 4.0 sq. mm - 6 Nos and 2.5 sq. mm - 2 Nos in PVC conduit/casing-capping with junction box - The price shall cover for wiring of six wire sub-main with 4.0 sq. mm PVC insulated, unsheathed, multi-stranded, FRLS copper conductor of 1100 Volt grade, ISI marked, conforming to IS: 694/1990 with one wire of 2.5 sq. mm PVC insulated, unsheathed, multi-stranded, FRLS copper conductor of 1100 Volt grade, ISI marked, conforming to IS: 694/1990 in PVC casing-capping or medium grade PVC conduit of not less than 25 mm diameter, ISI marked as per site conditions with junction boxes at suitable intervals as per requirement. | — | — | — | 23,100 | |
| — | 100.00 | — | — | ||
| Tapping of light/fan point with 1.5 sq. mm copper wire with connector from existing catenary/PVC trunking - The price shall cover for tapping of light/fan point with heavy duty connector with two wires of 1.5 sq. mm, PVC insulated, unsheathed, multi-stranded, FRLS copper conductor of 1100 Volt grade, ISI marked, conforming to IS: 694/1990 and one wire of 1.0 sq. mm, PVC insulated, unsheathed, multi-stranded, FRLS copper conductor of 1100 Volt grade, ISI marked, conforming to IS: 694/1990 in green colour as earthing wire in PVC flexible pipe from existing catenary/PVC trunking. | — | — | — | 14,400 | |
| — | 20.00 | — | — | ||
| Providing electronic fan regulator, modular type - The price shall cover for supply, fixing, testing and commissioning of hum-free modular type electronic fan regulator suitable for 80/100-Watt ceiling fan of step type with 'OFF' position, surface/flush type on existing board and its connection from existing supply. The colour of regulator should be in sync with the switch board. Miniature switch type regulators shall not be accepted. The regulator shall be got approved from site engineer before supply and installation. | — | — | — | 5,120 | |
| — | 25.00 | — | — | ||
| Fixing, testing and commissioning of ceiling fan - The price shall cover for fixing, testing and commissioning of ceiling fan on existing hook and its connection by FRPVC insulated, flexible copper cord, 1100Volt grade, 24/0.20mm from existing ceiling rose with earth connection. A suitable suspension clamp made from G.I. flat of 40 x 6 mm with MS 'S' shaped hook of diameter not less than 10 mm shall be provided as per site requirement if fan hook is not available and is included in the scope of work. The ceiling fans shall be supplied by railways at site in-charge's office/store. | — | — | — | 4,100 | |
| — | 10.00 | — | — | ||
| Providing Exhaust Fan, 300 mm sweep, heavy duty with louver/bird guard - The price shall cover for supply of heavy duty, industrial Exhaust Fan of metal body, 300 mm sweep with bird guard operating on 230 Volt, 50 Hz AC supply complete with all accessories. The colour of the Exhaust Fan shall be as per the site requirement as per the decor of the building. The price shall also cover for fixing, testing and commissioning of the Exhaust Fan on existing pocket with rake bolts/Anchor fasteners of suitable size as per site condition, and its connection from existing ceiling rose with three-core, 24/0.20 mm size, FRPVC insulated, flexible copper wire of 1100 Volt grade. | — | — | — | 14,580 | |
| — | 20.00 | — | — | ||
| Providing heavy-duty, Air circulator fan, 750 mm sweep, industrial type complete with all accessories - The price shall cover for supply of heavy duty, wall mounted, Air Circulator fan, 750 mm sweep (approximately) having aluminium alloy one piece blade, double ball bearing, 90° oscillation, sturdy, closed mesh guard, single phase motor, to work on 230 Volt, 50 Hz single phase AC supply. The air circulator fan shall be got approved from site engineer before supply. The Air Circulator fan shall be provided with three core FRPVC copper flexible cord 48/0.20 mm size of suitable length. The Air Circulator shall be fitted on the structure/wall/pillar by providing M.S. clamp of 50 x 5 mm made from M. S. flat duly painted with two coats of anti- corrosive red oxide and two coats of silver enamel paint by providing proper rake bolts. The circulator shall be connected with existing supply point as per site conditions. | — | — | — | 1,94,420 | |
| — | 10.00 | — | — | ||
| Supply, fixing, testing and commissioning of three-phase pre-cooling point, 750 Volt, with MCCB, three-pole, 125 Amp, heavy duty plug- socket, 63 Amp in outdoor type MS enclosure - The price shall cover for supply, fixing, testing and commissioning of three-phase, heavy-duty, power plug and socket, 125 Amp of BCH make (Cat. No. DS9A7A1) or similar model of L&T/SIEMENS/HPL with MCCB TPN 125 Amp, with thermal-magnetic release range 100 - 125 Amp, Ics = 100% Icu having 35 KA breaking capacity and conforming to IS/IEC 60947-2 with adjustable overload and short circuit settings and inbuilt instantaneous protection and working on 415 Volt, 50 Hz, AC supply. The MCCB shall be supplied with spreader terminals and rotary handle. The power receptacle shall be equipped with five-pin, 415 Volt power plug of 125 Amp capacity. The entire assembly shall be mounted in a suitable modular enclosure, dust, water and vermin proof suitable for indoor/outdoor mounting and suitable for three-phase, four-wire, 750 Volt, 50 Hz supply system. The box shall be internally wired by suitable size PVC insulated, single core flexible copper multi-strand wire with copper crimping lugs. The box shall be securely mounted on cover shed pillars/wall with necessary M.S. clamps, nuts, bolts etc. The drawing, design of plug socket, switch gears with make and model shall be got approved by field in-charge before fabrication and supply of the material. | — | — | — | 1,77,400 | |
| — | 10.00 | — | — | ||
| Providing lighting control board with MCB DP, 32 Amp - 1 No, Time Switch, 16 Amp - 1 No and Single-Phase Contactor, 32 Amp - 1 No - The price shall cover for supply, fixing, testing and commissioning of lighting control board fabricated from CRCA sheet steel, powder coated with grey finish, dust and vermin proof, water resistant with metallic door complete with MCBs of 10 KA breaking capacity. The board shall be equipped with MCB DP, 10 KA breaking capacity, 32 Amp rating - 1 No, Time switch, 16 Amp - 1 No and Single phase contactor of rating 32 Amp - 1 No. The board shall be completely wired with multi-stranded copper wire of suitable capacity and shall be provided with heavy duty connectors of suitable capacity for termination of incoming and outgoing wires and shall be provided with two nos of earthing terminals on each side of the board and riveted metallic caution board in three languages. | — | — | — | 43,200 | |
| — | 4.00 | — | — | ||
| Providing Distribution Board with incomer MCB TPN, 63 Amp - 1 No, RCBO, four-pole, 63 Amp - 1 No and outgoing MCB DP, 10 to 32 Amp - 12 Nos - The price shall cover for supply, fixing, testing and commissioning of pre-fabricated, double door, MCB distribution board fabricated from CRCA sheet steel, powder coated with grey finish, dust and vermin proof, water resistant with metallic door complete with MCBs of 10 KA breaking capacity. The DB shall be equipped with incomer MCB TPN, 63 Amp - 1 No, RCBO, four-pole, 30 mA sensitivity, 63 Amp - 1 No and outgoing MCB DP, 10 to 32 Amp - 12 Nos. The board shall be completely wired with multi-stranded copper wire of suitable capacity and shall be provided with heavy duty connectors of suitable capacity for termination of incoming and outgoing wires and shall be provided with two nos of earthing terminals on each side of the board and riveted metallic caution board in three languages. The Distribution Board shall be suitable for surface/recessed installation. | — | — | — | 56,604 | |
| — | 3.00 | — | — | ||
| Providing outdoor type, wall/floor mounted, double-door, Distribution Board with incomer MCCB, four-pole, 100 Amp - 1 No and outgoing MCCB, four-pole, 63 Amp - 3 Nos complete with indication lamps, bus-bar, earthing terminals and all accessories - The price shall cover for design, supply, installation, testing and commissioning L.T. Distribution Panel fabricated from 2.0 mm thick M.S. sheet, standard angles, channels etc. as required in design.The LT panel shall be indoor/outdoor type, double-door, rectangular cubicle type, dust and vermin proof suitable for floor mounting for three- phase, four-wire, 415 Volt, 50 Hz AC supply system. Detailed specifications are given in Annexure-XXI of tender document. | — | — | — | 1,19,052 | |
| — | 1.00 | — | — | ||
| Providing outdoor type, wall/floor mounted, double-door, Distribution Board with incomer MCCB, four-pole, 125 Amp - 1 No and outgoing MCCB, four-pole, 100 Amp - 2 Nos, MCB DP, 25 Amp - 3 Nos with Time Switch, 16 Amp - 1 No and Single-Phase Contactor, 32 Amp - 1 No complete with indication lamps, bus-bar arrangement, earthing terminals and all accessories - The price shall cover for design, supply, installation, testing and commissioning L.T. Distribution Panel fabricated from 2.0 mm thick M.S. sheet, standard angles, channels etc. as required in design.The LT panel shall be indoor/outdoor type, double-door, rectangular cubicle type, dust and vermin proof suitable for floor mounting for three-phase, four-wire, 415 Volt, 50 Hz AC supply system. Detailed specifications are given in Annexure-XXI of tender document. | — | — | — | 66,817 | |
| — | 3.00 | — | — | ||
| Providing outdoor type, wall/floor mounted, double-door, Distribution Board with incomer MCCB, four-pole, 125 Amp - 2 Nos and outgoing MCCB, four-pole, 100 Amp - 2 Nos, MCCB, four-pole, 63 Amp - 2 Nos and MCB TPN, 32 Amp - 2 Nos complete with digital multifunction meter, indication lamps, bus-bar arrangement, earthing terminals and all accessories - The price shall cover for design, supply, installation, testing and commissioning L.T. Distribution Panel fabricated from 2.0 mm thick M.S. sheet, standard angles, channels etc. as required in design.The LT panel shall be indoor/outdoor type, double-door, rectangular cubicle type, dust and vermin proof suitable for floor mounting for three-phase, four-wire, 415 Volt, 50 Hz AC supply system. Detailed specifications are given in Annexure-XXI of tender document. | — | — | — | 2,43,795 | |
| — | 1.00 | — | — | ||
| Providing outdoor type, wall/floor mounted, double-door, Distribution Board with incomer MCCB, four-pole, 160 Amp - 2 Nos and outgoing MCCB, four-pole, 100 Amp - 2 Nos, MCCB, four-pole, 63 Amp - 2 Nos and MCCB, four-pole, 32 Amp - 4 Nos complete with digital multifunction meter, indication lamps, bus-bar arrangement, earthing terminals and all accessories - The price shall cover for design, supply, installation, testing and commissioning L.T. Distribution Panel fabricated from 2.0 mm thick M.S. sheet, standard angles, channels etc. as required in design.The LT panel shall be indoor/outdoor type, double-door, rectangular cubicle type, dust and vermin proof suitable for floor mounting for three-phase, four-wire, 415 Volt, 50 Hz AC supply system. Detailed specifications are given in Annexure-XXI of tender document. | — | — | — | 1,33,353 | |
| — | 1.00 | — | — | ||
| Supply, fixing, testing and commissioning of outdoor type LT Distribution Panel with incomer MCCB, four pole, 1000 Volt, 630 Amp - 1 No and outgoing Power Contactor, four-pole, 1000 Volt, 1000 Amp capacity - 2 Nos. The panel shall consist of 750/415-Volt three core step down transformer - 2 Nos for control circuit with Auxiliary contactor, four-pole, 415 Volt, 20 Amp and two-pole two-way rotary switch 20 Amp with copper bus-bar of adequate capacity, indication lamps, earthing terminals, caution board etc. The panel shall be connected with Coupling Socket Assembly, 500 Amp, 750 Volt, three-phase, 50 Hz AC supply, suitable for LHB type AC coaches as per RDSO's Specification No. RDSO/PE/SPEC/AC/0177-2013 (Rev-0) with ratchet locking arrangement - 2 Nos for Inter Vehicular Coupler enclosed in stainless steel housing connected to the panel with electron-beam copper cable of size 150 sq. mm laid in heavy duty flexible polyamide conduit of suitable size with proper lugged and crimped termination as per RDSO's specifications - The price shall cover for design, supply, installation, testing and commissioning of outdoor type L.T. Distribution Panel fabricated from 2.0 mm thick M.S. sheet, standard angles, channels etc. as required in design.The LT panel shall be suitable for outdoor installation, rectangular-cubicle type, dust and vermin proof, floor mounted type suitable for three-phase, four-wire, 1000 Volt, 50 Hz AC supply system. Detailed specifications are given in Annexure-XXI of tender document. | — | — | — | 4,55,059 | |
| — | 1.00 | — | — | ||
| Supply, installation, testing and commissioning of L.T. Distribution Board with incomer ACB, four-pole, EDO, microprocessor based, 750 Volt, 800 Amp - 2 Nos and outgoing MCCB, four-pole, 630 Amp - 4 Nos with three-core, 750/415 Volt transformer for voltage measurement and multifunctional meter and all accessories - The price shall cover for design, supply, installation, testing and commissioning L.T. Distribution Panel fabricated from 2.0 mm thick M.S. sheet, standard angles, channels etc. as required in design. The drawing, design, switchgears with make and model of the LT panel shall be submitted by the contractor in three copies and got approved by Sr. DEE (Power) Vadodara before fabrication.The LT panel shall be indoor, rectangular-cubicle type, dust and vermin proof suitable for three-phase, four-wire, 750 Volt, 50 Hz AC supply system. Detailed specifications are given in Annexure-XXI of tender document. | — | — | — | 5,33,600 | |
| — | 1.00 | — | — | ||
| Supply, fixing, testing and commissioning of Distribution Transformer, 1000 KVA, 11000/750 Volt, three-phase complete with all accessories and foundation - Scope of Work - The scope of work covers Design, manufacture, supply, erection, testing and commissioning of 1000 KVA, 11 KV / 750 V, three-phase, 50 Hz, delta/star connected, outdoor type transformer as per IS: 1180 Part I, Energy Efficiency Level 2, oil immersed ONAN cooled, complete with oil conservator, silica gel breather, thermometer, explosion vent and all other fittings and valves, OFF LOAD tap changer with +5% and -15% tapings in step of 2.5%, bidirectional roller, diagram and rating plate, oil temperature indicator, winding temperature indicator and Buchholz relay with wiring up to marshalling box, lifting lugs, first filling of oil (Oil as per IS:12463), weather proof HT cable box, LT cable termination box, non- magnetic gland plate or Bus Bar termination as per manufacturer design etc. complete as per specification including 10% extra oil in non-returnable drum for topping up as required. (The transformer shall be subject to all tests specified in the specifications and relevant IS). Detailed specifications are given in Annexure-XXI of tender document. | — | — | — | 17,37,321 | |
| — | 762.00 | — | — | ||
| Digging of cable trench 450/600 mm wide and 900 mm deep in all types of soil including hard, rocky etc - The price shall cover for digging of 450/600 mm wide and 900 mm deep trench in all types of soil including soft, rocky as per cable route plan and filling back the trench after laying of cables. This also includes clearing of roots of trees and bushes and other temporary obstructions on the selected route. | — | — | — | 94,488 | |
| — | 1500.00 | — | — | ||
| Digging of cable trench 100 mm wide and 200 mm deep in concrete/tar road/platform and refilling to its original position after laying of cable in 50 mm diameter HDPE pipe - The price shall cover for digging of cable trench of size 100 x 200 mm deep in concrete/tar road/platform surface and its refilling/plastering after laying of cable in 50 mm diameter HDPE pipe confirming to IS 4984:2016 in existing trench. Supply and laying of HDPE pipe, 110 mm diameter is included in the scope of work. | — | — | — | 5,46,000 | |
| — | 860.00 | — | — | ||
| Digging of cable trench 200 mm wide and 200 mm deep in concrete/tar road/platform and refilling to its original position after laying of cable in 110 mm diameter HDPE pipe - The price shall cover for digging of cable trench of size 200 x 200 mm deep in concrete/tar road/platform surface and its refilling/plastering after laying of cable in 110 mm diameter HDPE pipe confirming to IS 4984:2016 in existing trench. Supply and laying of HDPE pipe, 110 mm diameter is included in the scope of work. | — | — | — | 5,45,240 | |
| — | 1000.00 | — | — | ||
| Supply and laying of HDPE pipe, 32 mm diameter in existing trench - The price shall cover for supply of HDPE pipe of 32 mm diameter confirming to IS 4984:2016. The HDPE pipe shall be made of virgin thermoplastic, material grade-PE 100, pressure rating-PN 10 and wall thickness of approximately 3.5 mm. The pipes shall be "ISI" marked. Accessories like HDPE snap fit coupler with neoprene 'O' ring shall be part of supply to make the joints water/damp proof.The price shall also cover for laying the HDPE pipe in the trench for laying of underground cable as instructed by site engineer. Each length of the pipes shall be joined together properly using proper size of socket and aligned in a straight line, keeping an inclination to facilitate the draining of water. | — | — | — | 75,000 | |
| — | 1300.00 | — | — | ||
| Supply and laying of DWC pipe, 63 mm diameter - The price shall cover for supply of Double Wall Corrugated (DWC) HDPE pipe of 63 mm diameter. DWC HDPE pipe shall have corrugation on outer wall but inner wall shall be plain conforming to IS: 14930 Part I and II amended from time to time. The pipes shall be "ISI" marked. Accessories like HDPE snap fit coupler with neoprene 'O' ring shall be part of supply to make the joints water/damp proof. The strength and stiffness class of the pipe shall be SN4 and SN8 respectively.The price shall also cover for laying the DWC pipes in the ground below the tracks/road by push through method at a depth below the formation level as indicated in the drawing supplied by railway. The term "formation" level means the earth surface just below the bedding of the ballast. In case of any hard/stony soil, contractor should adopt new technology method in push through method. Each length of the pipes shall be joined together properly using proper size of socket and aligned in a straight line, keeping an inclination to facilitate the draining of water. | — | — | — | 98,800 | |
| — | 120.00 | — | — | ||
| Supply and laying of DWC pipe, 120 mm diameter - The price shall cover for supply of Double Wall Corrugated (DWC) HDPE pipe of 120 mm diameter. DWC HDPE pipe shall have corrugation on outer wall but inner wall shall be plain conforming to IS: 14930 Part I and II amended from time to time. The pipes shall be "ISI" marked. Accessories like HDPE snap fit coupler with neoprene 'O' ring shall be part of supply to make the joints water/damp proof. The strength and stiffness class of the pipe shall be SN4 and SN8 respectively.The price shall also cover for laying the DWC pipes in the ground below the tracks/road by push through method at a depth below the formation level as indicated in the drawing supplied by railway. The term "formation" level means the earth surface just below the bedding of the ballast. In case of any hard/stony soil, contractor should adopt new technology method in push through method. Each length of the pipes shall be joined together properly using proper size of socket and aligned in a straight line, keeping an inclination to facilitate the draining of water. | — | — | — | 20,280 | |
| — | 150.00 | — | — | ||
| Providing uPVC pipe, 50 mm diameter - The price shall cover for supply of uPVC pipe of 50 mm nominal bore diameter and working pressure of 14 kg/sq. cm along with coupling, elbow, tee etc for protection of cable. The upright cable shall be encased in uPVC pipes for mechanical protection. The pipe shall be clamped with flat MS clamp at each location on upright cable length. uPVC Pipe shall be as per ASTM-D:1785, Sch-80.The price shall also cover for laying the uPVC pipes in ground/road and under the track by digging open trench method. Each length of the pipes shall be joined together using proper size of uPVC coupler and properly aligned in a straight line, keeping an inclination to facilitate the draining of water. | — | — | — | 26,400 | |
| — | 330.00 | — | — | ||
| Supply and laying of HDPE pipe, 110 mm diameter by pushing method under track/road - The price shall cover for supply of HDPE (High Density Polyethylene) pipe of 110 mm nominal diameter as per IS 4984-2016 with accessories required for laying such as coupler, bend etc as per specifications given in Annexure-XXI of tender document. The price shall also cover for laying the HDPE pipes in the ground below the tracks/road by push through method at a depth below the formation level as indicated in the drawing supplied by railway. The term "formation" level means the earth surface just below the bedding of the ballast. In case of any hard/stony soil, contractor should adopt new technology method in push through method. Each length of the pipes shall be joined together properly using proper size of socket and aligned in a straight line, keeping an inclination to facilitate the draining of water. | — | — | — | 4,25,040 | |
| — | 50.00 | — | — | ||
| Supply and laying of HDPE pipe, 160 mm diameter by pushing method under track/road - The price shall cover for supply of HDPE (High Density Polyethylene) pipe of 160 mm nominal diameter as per IS 4984-2016 with accessories required for laying such as coupler, bend etc as per specifications given in Annexure-XXI of tender document. The price shall also cover for laying the HDPE pipes in the ground below the tracks/road by push through method at a depth below the formation level as indicated in the drawing supplied by railway. The term "formation" level means the earth surface just below the bedding of the ballast. In case of any hard/stony soil, contractor should adopt new technology method in push through method. Each length of the pipes shall be joined together properly using proper size of socket and aligned in a straight line, keeping an inclination to facilitate the draining of water. | — | — | — | 56,000 | |
| — | 100.00 | — | — | ||
| Providing PVC maxi trunking of size 100 x 50 mm - The price shall cover for supply, fixing, testing and commissioning of ISI marked PVC Maxi Trunking of size 100 x 50 mm with all accessories. The PVC Maxi trunking shall be fixed at site by fabricated clamp of 18 SWG GI sheet at a distance not more than 1.5 meters by machine screw/GI nut bolts, washers etc. The existing power cables shall be laid in the PVC Maxi trunking properly dressed and secured by means of suitable clamps/fasteners etc. | — | — | — | 46,000 | |
| — | 400.00 | — | — | ||
| Supply and erection of G.I. perforated cable tray of size 150 mm x 100 mm x 100 mm on MS frame with cover - The price shall cover for fabrication, supply and fixing of M.S. perforated cable tray, hot dip galvanized as per latest ISS/BSS of size 150 x 100 x 100 mm and 2.0 mm approximate thickness with appropriate cover of thickness 1.6 mm. The cable tray shall be fixed horizontally or vertically at site and the existing LT cables shall be laid/shifted in the cable tray by disconnecting from the panel/switch end and reconnecting as per site requirement duly tied with suitable clamps with GI nuts, bolts and washers in a safe and secure manner. The fixing clamps shall be fabricated from 50 x 50 x 6 mm MS angle or 50 x 6 mm MS flat duly painted and fixed at approximate distance of 1.5 to 2.0 meter apart with 2" long dowel/fisher rack bolts. The tray shall be fabricated in lengths of 2.0 m and couplers shall be provided at joints. The cable tray cover shall be fixed with GI screws. | — | — | — | 3,02,000 | |
| — | 5480.00 | — | — | ||
| Laying of cable in trench - The price shall cover for laying, testing and commissioning of LTUG armoured cable in existing trench/pipe and its connection at both ends. The cable shall be tested with 500 Volt Megger earth tester before laying it in the trench. The cable cores shall be tested for continuity, absence of cross phasing, Insulation Resistance between conductors to earth/armour and between conductors. The results should be recorded in presence of railways' representative. A composite cable layout plan on ferro-print or computerized print duly laminated in A-4 size should be submitted by the contractor to this office as well as site in-charge after laying of cable. Cables shall be supplied by railways at site engineer's stores. | — | — | — | 1,15,080 | |
| — | 1500.00 | — | — | ||
| Laying of cable on wall/cover shed/existing tray with MS clamp - The price shall cover for laying, testing and commissioning of LTUG armoured cable on wall/cover shed/in existing tray and its connection at both ends. The cable shall be tested with 500 Volt Megger before laying it in the tray. The cable cores shall be tested for continuity, absence of cross phasing, Insulation Resistance between conductors to earth/armour and between conductors. The results should be recorded in presence of railways' representative. A composite cable layout plan on ferro-print or computerized print duly laminated in A-4 size should be submitted by the contractor to site engineer and Divisional Office after laying of cable. | — | — | — | 46,500 | |
| — | 900.00 | — | — | ||
| Supply of single core 150 sq. mm, Electron-beam, irradiated, chemically cured, cross-linked, thin walled, flexible, elastomeric cable with copper conductors - The price shall cover for supply of single core 150 sq.mm, Electron-beam, irradiated/chemically cured, cross-linked, thin walled, flexible, elastomeric cable with copper conductors for working voltages above 750 Volt up to 1.8/3.0 KV for coaching stock. The cable should confirm to RDSO's Specification No. ELRS/SPEC/ELC/0019 (Rev-3) with latest amendments. Copy of the specification is uploaded with the tender documents. The cable shall be of reputed and approved make if any. A copy of test certificate shall be submitted along with the cable. | — | — | — | 17,90,100 | |
| — | 2.00 | — | — | ||
| Supply, fixing, testing and commissioning of heat shrinkable cable end termination kit, 11 KV indoor type, three-core, 185 sq. mm for XLPE Aluminium armoured cable - The price shall cover for supply, jointing, testing and commissioning of 11 KV indoor type heat shrinkable cable end box for 11 KV, three-core, 185 sq. mm, XLPE cable. The individual cores of the cables shall be properly identified to avoid cross connections of the core while connecting them to the corresponding phases. The contractor shall engage skilled cable jointer for making the end termination and it should be provided only in presence of Railways' representative after taking proper shut down. For termination of cable, proper size of cable gland and lugs shall be provided. The cable shall be tested with a 5000 Volt Megger before and after preparation of joint and the values shall be recorded jointly. | — | — | — | 11,252 | |
| — | 2.00 | — | — | ||
| Supply, fixing, testing and commissioning of heat shrinkable cable end termination kit, 11 KV outdoor type, three-core, 185 sq. mm for XLPE Aluminium armoured cable - The price shall cover for supply, jointing, testing and commissioning of 11 KV outdoor type heat shrinkable cable end box for 11 KV, three-core, 185 sq. mm, XLPE cable. The individual cores of the cables shall be properly identified to avoid cross connections of the core while connecting them to the corresponding phases. The contractor shall engage skilled cable jointer for making the end termination and it should be provided only in presence of Railways' representative after taking proper shut down. For termination of cable, proper size of cable gland and lugs shall be provided. The cable shall be tested with a 5000 Volt Megger before and after preparation of joint and the values shall be recorded jointly. | — | — | — | 20,240 | |
| — | 61.00 | — | — | ||
| Supply, fixing, testing and commissioning of 5.0-meter height G.I. Street Light octagonal pole, double arm complete with all accessories and foundation - The price shall cover for supply, erection and commissioning of 5.0 meter height double arm, G.I. street light octagonal pole as per the below mentioned specifications.G.I. Octagonal pole of 5.0 meter height, Top - 70 mm diameter, Bottom - 130 mm diameter and 3 mm thickness sheet. Base plate of minimum dimension 200 x 200 x 12 mm, foundation bolts (4 Nos with 3 Nos of nuts and washers in each), double arm bracket for mounting the light fittings, Bakelite sheet with one MCB SP, 6 Amp and 16 sq. mm stud type connector (4 Nos) inside the pole at door opening for cable connection, common templates minimum for 15 poles.Detailed specifications of Galvanized Octagonal poles are given in Annexure-XXI of tender document. | — | — | — | 8,25,940 | |
| — | 2.00 | — | — | ||
| Design, supply, erection, testing and commissioning of 12.0 meter High Mast complete with all accessories - The price shall cover for design supply, erection, testing and commissioning of 12 meter high mast suitable for 12 Nos LED flood light luminaries of 160 Watt complete with lantern carriage ring, mounting brackets, foundation bolts, templates, winch wire ropes, power tools, etc including connection required for fixing of the above fixture on the high mast.The high mast of 12 meter height should be in two sections, hot dip galvanized and suitable for wind velocity as per IS: 875 (Part 3) 1987 as per latest amendments. It shall also include accessories for high mast including head frame two/three point suspension system with steel wire rope 6 mm diameter (7/19 construction), single drum winch, galvanized lantern carriage arrangement, suitable for 12 (Twelve) Nos of LED luminaries for 12 meter high mast and its control gear boxes and lightning finial. Technical Data Sheet for 12 Meter High Mast and Accessories are given in Annexure- XXI of tender document. | — | — | — | 4,51,880 | |
| — | 180.00 | — | — | ||
| Supply and laying of flexible copper cable, three-core, 1.5 sq mm - The price shall cover for supply and laying of PVC insulated, multi- stranded, flexible, three-core, copper conductor cable, 1.5 sq. mm, 1100 Volt grade, ISI marked, conforming to IS: 694 or latest. The copper wire and earth wire shall be laid in PVC conduit of suitable size and properly fixed as per the instructions of site engineer. | — | — | — | 16,920 | |
| — | 50.00 | — | — | ||
| Supply and laying of flexible copper cable, ten-core, 1.5 sq mm - The price shall cover for supply and laying of PVC insulated, multi- stranded, flexible, ten-core, copper conductor cable, 1.5 sq. mm, 1100 Volt grade, ISI marked, conforming to IS: 694 or latest. The copper wire and earth wire shall be laid in PVC conduit of suitable size and properly fixed as per the instructions of site engineer. | — | — | — | 16,050 | |
| — | 264.00 | — | — | ||
| Design, manufacture, display, installation of wall/hanging/floor mounting type signage/directional boards in flat/half elliptical/ Parabolic/Triangular shape. The display sheet shall be of unbreakable 040 translucent polycarbonate sheet of 2.0 mm thickness. The text/graphics matter visibility shall not be less than 160 deg. The approved colour text and graphics shall be printed/router cut on monomeric calendared vinyl of 70 um thickness and shall be firmly pasted on display sheets/Retro Reflective Boards. The mounting arrangement shall be hanging, wall mounting, ceiling mounting, pole mounting or floor mounting and as per site requirement to be provided by the contractor with their own materials, labour, all Tools & Plants, lead, lift, transportation etc including all applicable taxes. The signage shall have the integral mounting arrangements with sturdy structural frame and ACP cladding on the back side of the signage to avoid rusting and entry of dust. The scope of work covers various railway stations over Vadodara division. The work shall be carried out as per the "Guidelines on Standard Signages at Stations on Indian Railways, 2023" issued by the Ministry of Railways, Government of India. The work shall be executed strictly as per the specifications given in the document which is attached as Annexure. Colour scheme, font sizes, directional arrows, materials, fabrication, text, pictogram shall be as given in the document. | — | — | — | 6,39,144 | |
| — | 1050.00 | — | — | ||
| Providing PVC insulated and sheathed, single core, multi-stranded, Aluminium conductor cable, 10.0 sq. mm - The price shall cover for supply of single core, PVC insulated and sheathed, stranded, Aluminium conductor of 10 sq. mm cross sectional area conforming to IS 1554 - Part-1. The cable shall be flame retardant, should not support combustion and shall be self-extinguishing. The price shall also cover for laying of the cable for earth continuity from different points as advised by site engineer. | — | — | — | 22,050 | |
| — | 250.00 | — | — | ||
| Providing GI earthing strip, 25 x 4 mm with PVC sleeve - The price shall cover for supply and laying of G.I. earthing strip of 25 x 4 mm size covered with black coloured PVC sleeve of superior quality from earth pit to control/distribution panel board. The earthing strip when laid on wall shall be fixed by means of suitable size of GI clamps and screws. | — | — | — | 20,250 | |
| — | 18.00 | — | — | ||
| Providing maintenance free earthing - The price shall cover for providing maintenance free earthing as per the following specifications - (1) High tensile-low carbon steel rod having diameter not less than 17 mm complying with requirements of BS 4360 Grade 43A or EN10025:2-004 S275JR, molecularly bonded by 99.99% pure high conductivity copper on outer surface with copper coating thickness of 250 micron or more, Length 3000 mm (minimum). Certificates from NABL approved labs shall be submitted with test results. (2) Copper earth bus-bar of size 250 mm x 50 mm x 6 mm having electrical conductivity of 101% IACS, minimum 99.9% copper content shall be exothermically welded to rod with 4 holes of 12 mm diameter (two on each side) for connecting earthing conductor. (3) Earth Enhancement compound should have characteristics as mentioned in the RDSO specifications. It should have low resistivity preferably below 0.2 Ohm-meter, supplied in sealed bags (minimum 75 kg per pit for 5' x 5' x 10' size pit and minimum 50 kg per pitfor 300 mm bore type pit. The bags shall be marked with manufacturer's name or trade name, quality, Batch No. and date of manufacture. Certificates from NABL approved labs shall be submitted with test results, for at least following parameters - (i) Composition of Earth Enhancement compound (ii) Resistivity - <2 Ohm-meter (iii) pH value - >7 but <9 (iv) Moisture retaining capacity - >10% at 105 degrees Celsius (v) Water solubility - <5%. (4) Backfill material - Good quality soil or excavated soil free from sand, gravel and stones shall be used for backfilling. (5) Earth pit of size 5 feet x 5 feet x 10 feet or min 300 mm bore up to 10 feet using earth auger shall be made. (6) Inspection chamber - A concrete box of 300 x 300 x 300 mm (inside dimensions) and50 mm thickness of wall, with smooth cement plaster finish shall be provided on the top of the pit. A concrete lid, painted black, approximately 50 mm thick with pulling hooks shall be provided to cover the earth pit. PVC sleeve shall be provided in concrete wall to take out earthing connections. (7) On backside of the cover, date of the testing and average resistance value shall be written with yellow paint on black background. (8) Instead of copper busbarand strips mentioned in the drawing, a GI main bus-bar of minimum size 300 mm x 75 mm x 8 mm to be installed on nearby wall etc. It shall be connected to earthing with two GI strips of 50 mm x 6 mm size each, up to a distance of 10 meters from earth bus-bar (minimum 3 meters x 2 Nos GI strips to be supplied). (9) Earthing shall generally be carried out in accordance with the requirement of I.E. Rules, 1956, as amended from time to time and shall confirm to IS: 3043 of 1987 with latest amendment. (10) The earth value shall be measured and recorded at the site by painting on earth pit or nearest wall along with date of testing. It shall be less than 2 Ohms and neutral to earth voltage shall be less than 3 Volt. (11) Earthing performance after a year of installation shall be jointly checked and measured. It should be less than 2 Ohm. (12) General arrangement of the earth system shall be as the drawing given in Annexure-XXI of tender document. | — | — | — | 1,83,870 | |
| — | 5.00 | — | — | ||
| Providing copper plate earthing - The price shall cover for providing copper plate earthing made from copper plate of 600 mm x 600 mm x 3.15 mm thick (approximately) buried at not less than 2.5 m deep in soil along with charcoal and salt layer alternately. The earth connection should be made with PVC insulated stranded copper conductor of 16 mm2 from earth electrode to earthing bus bar/apparatus. The earth pit shall be 4 m away from the other earth pits and at least 30 m away from the earth pit of Lightning Arrestor. The potential difference between earth and neutral of filtered/stabilized source should be less than 2 Volt. The earthing installation should be provided with RCC circular box with cover and G.I. "J" bolts. The earthing should be carried out as per IS 3043/1987 or latest and relevant I.E. regulations. The contractor shall maintain the earth resistance below 0.5 and joint testing report along with railways' representative shall be submitted to the site-in-charge. | — | — | — | 61,315 | |
| — | 30.00 | — | — | ||
| Removal of unused existing rail poles complete with overhead line spans and other accessories and shifting the released materials to stores depot - The price shall cover for removal of existing rail/tubular poles and complete structure and other accessories by digging pole from base with required tools, tackles and manpower in a safe and secure manner. The dismantled rail/round poles, cross-arms, insulators, M.S. clamps, G.I. pipes and released fittings if any shall be segregated, transported and handed over to the site engineer at his office/stores depot with delivery challan. | — | — | — | 61,680 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TechSpecsofEnergyEfficientLEDBasedLuminaire.pdf
ATTACHMENT
RailwayBoardsletterNo.2018_CE-I_CT_9dated04.06.18.pdf
ATTACHMENT
WesternRailwaysSpecificationsforACBLTPanelsMCCBandMCB.pdf
ATTACHMENT
2024_06_03InstructionforincorporatingtheJPOCircularetc_ProvisionsintheTenderDocumentforallworksrequiringdiggingworksclosetoRly1.pdf
ATTACHMENT
BankGuaranteeverification.pdf
ATTACHMENT
SpecforHighCapacityIVCouplersforEOGcoaches.pdf
ATTACHMENT
Specforthinwalledflexibleelastomericcables.pdf
ATTACHMENT
TenderDocumentBRC-EL-P-27-26-27NEWGCC.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .