Col Siddharth Sharma CWE NW Kochi
Shri M Mani EE QS C
PROVISION FOR DEFICIENT LIFT FOR ATC BUILDING NO P-4 INCLUDING 03 YEARS COMPREHENSIVE MAINTENANCE AT INS GARUDA NAVAL BASE KOCHI
2026_MES_797555_1
CWE(NW)KOCHI/81567
Open Tender
Civil Works
Item Rate
270 days
GE NS KOCHI
As per NIT
7 documents required · 7 mandatory
₹1,000
GS NS KOCHI
₹1.7 L
Yes
5 Nov 2026
5 Nov 2026
7 Dec 2026
5 Nov 2026
3 Dec 2026
26 Nov 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | LIFT AND CIVIL WORK:
Design, supply, installation, testing and commissioning of electrically operated Machine room less (MRL) Passengers lift of capacity 408 kg (06 Passenger) with a speed of 1.25 mtr/ sec to serve ground floor and 04 upper floors (G+4), with microprocessor based operation and with simplex collective, selective, control with or without lift attendant and with variable voltage, variable frequency system with two speed automatic control drive, with elevator sliding car door and landing door made of stainless steel, car cage made out of not less than 1.2 mm thick stainless steel (SS 316), vandal proof (Scratch free, Hairline finish) as well as cage roof covered with stainless steel sheets of suitable size cage floor made of granite floor minimum 10mm thick of approved colour, automatic car levelling micro stroke push button operation and floor indicators in car in all landings, fire man switch, emergency lamp, alarm push button etc with and including automatic rescue device (ARD) battery operated with and including maintenance free battery of suitable capacity and battery charger with optimum direction section in start operation requiring no human intervention, 3D infra red sensor in full length of doors and built in floor announcing system with 03Nos handset one each in car, Top floor near control panel and ground floor and over load indicator with suitable for three phase, 415 volts, 50 Hz AC supply for passenger lift and LT panel incl all accessories such as MCCB/Isolator/MCB and connected items with the recommendation of OEM and EIC including construction of lift building in permanent specification as per E-in-C specifications (excluding pile foundation and pile cap) & including connecting passage with steel structure & SS hand rail, poly carbonate sheet wall & roof (including foundation) and consultancy for structural design & estimate as per architectural drawing all as specified and directed. | 1 | Job | - | - |
| 1.1 | Description for lift:-
(a) Quantity : 01 (One) unit
(b) Assembled Product : Passenger Elevator
(c) Capacity : 408 Kg
(d) Speed : 1.00 m/s
(e) Stops & Openings : 5 Stops, 5 Openings
(f) Floor designations : G,1,2,3,4
(g) Machine type & location : Gearless machine located in the overhead of lift well
(h) Control : Simplex collective selective control
(j) Drive : ACVVVF
(k) Power Supply : 3 Phase, 415V, 50 HZ
(l) Hoist Way Dimensions : 1800mm wide x 1600mm deep
(m) Car Travel : As per site requirement
(n) Overhead : 4200mm
(o) Pit depth : 1600mm
(p) Car Dimensions : 1000mm wide x 1100 mm deep x 2200 mm high
(q) Door Opening :2100 mm high centre opening/stainless steel Hairline finish (SS 316)
(r) Car Design : Stainless steel Hairline finish (SS 316)
(s) Car Flooring : Granite flooring 10mm
(t) Handrail : Round handrail in stainless steel finish provided on rear wall of car
(u) Landing operating panel : Individual landing operating panel for each floor in each elevator
(v) Displays : LCD Displays in cabin operating panel and in all landings
(w) Special Features : Automatic Rescue Devices with visual and audio indicator/3 way intercom/provision for camera cable
(x) Special Features : laminated mirror of entire width of rear panel of half height | - | - | - | - |
| 1.3 | Civil work for lift building
Construction of RCC framed structure lift building in permanent specification all as per E-in-'C's specification excluding pile foundation & pile cap all as per architectual & structural approved drg. | - | - | - | - |
| 1.4 | Civil work for connecting passage
Construction of connecting passage with steel structure and SS hand rail & 6mm poly carbonate sheet for roof and vertical faces all as specified and as per architectual & structural approved drawing.
Note for lift building & connecting passage : Architectural drawing provided with this is tentative. Any variation in size of room and structural members shall be finalised as per structural drg and as per manufacture's requirement for lift room and connecting passage. The rate quoted shall be inclusive of the same. | - | - | - | - |
| 1.5 | Consultancy for structrural design & estimate of lift building in G+4 configuration near ATC building in permanent specifications (Appx area 43.20 Sqm) and steel structural for connecting passage from 1st floor to 4th floor (Appx area 24 Sqm) along with closed varandah at ground floor with foundation all as per architectural drgs and soil report provided, including vetting of structural drawings from NIT/ IIT/ Govt Engineering collage and submisson of final drawings with input data file, structural drgs in autocad (one original set in tracing along with 3 sets in A2 size incl. Foundation plan, floor level plan and roof plan.
Note:-
(a) The design of building & steel structure from first floor to fourth floor shall be considering all parameters as per relevant IS like, IS 456 .2000 (latest version), IS 800 : 2007, IS 11384 : 1985, IS 875, IS 1893, IS 4326, IS 13920 etc. Importance factor 1.0 shall be as per relevant IS with severe exposure condition,the drg has to be got approved from HQ CWE(NW) Kochi before vetting by NIT/NIIT/ Govt Engineering college.
(b) Suitable design for connecting passage resting on existing building shall be part of design included in cost quoted.
(c) Yard stick for building works shall be provided by contractor to take approval from accepting officer. | - | - | - | - |
| 2 | Materials and labour for connecting up Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe as directed/specified for loop earthing etc as required of galvanised iron strip of size 32 x6 mm complete all as specified and directed.
Note; This item shall be measured for the quantity used at site after the length of strip 7.5 Mtr. | 50 | RM | - | - |
| 3 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3½ core. | 100 | RM | - | - |
| 4 | PILE FOUNDATION
Excavation over area ,n. exc. 1.5m in deep and getting out in soft/loose soil complete all as specified and as directed. | 14 | Cum | - | - |
| 5 | Excavation over area exc. 1.5m in depth and upto 3m in depth and getting out in soft/loose soil complete all as specified and as directed. | 5 | Cum | - | - |
| 6 | Boring for end bearing cast in situ piles upto 45 mtr depth mtrs in soil and getting out and disposal of spoil outside defence land using DMC method dia of pile 500 mm complete all as specified and as directed. | 270 | RM | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.63 MB
TENDERDOCUS.pdf
Tender Documents • 3.87 MB
BOQ_894655.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .