Expenditure
Capital (Works)
GSPGT
22 conditions · 3 needing a document upload
The Supply of Goods and Services would be subject to GST Act and Rules applicable from time to time.
I/We have read the various conditions to tender in the attached tender document and agree to abide by the said conditions.
I/We agree to keep this tender open for acceptance for a period of 45 days from the date of closing of this tender and in default thereof I/We will be liable for forfeiture of my/our Bid Security. I/We offer to do the work for Railway, at the rates quoted in the attached Schedule and hereby bind myself/ourselves to complete the works in all respects.
I/We also hereby agree to abide by the updated Regulations of Tenders and Contracts and General Conditions of Contract issued by the Engineering Department of Indian Railways along with correction slips issued from time to time and to carryout the work according to the Special Conditions of Contract and specifications of materials and works as laid down by Railway in the Annexed Special Conditions / Specifications, Schedule of Work for the present contract.
All rates quoted in the tenders shall be deemed to be inclusive of CGST, SGST, IGST etc., payable by the contractor to the Government or any public body and no additional amount/rate or claim will be entertained on this account by the Railways. Also no claim whatsoever will be accepted by Railways on account of revision of tax rates, new taxes of statutory nature by State/Central Govt.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
The tenderer shall go through the entire tender documents thoroughly and strictly adhere the instructions and directions given at different pages.
Deployment of Qualified Engineers at Work Sites by the Contractor - The Contractor shall employ 1 No. of qualified Graduate Engineer for works Rs. 200 Lakh or more and 1 No. of Diploma Engineer for works costing more than Rs. 25 Lakh, but less than Rs 200 Lakh
Augmentation of power supply connection at SRR-River bed pump house - Electrical arrangements
J-E-33-2025-26-W~SR
J-E-33-2025-26-W
Open
Works - General
6 Months
Palakkad, Kerala
₹0
₹40,300
15 Jan 2026
22 Dec 2025
1 Jan 2026
65 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 20,12,368 | ||
| — | 1.00 | — | — | ||
| "Shifting of existing 63kVA DG set with acquistic enclosure and AMF panel to new location (to new plinth) with all accessories. Note:- New proposed Location for DG set is very nearer to the existing location. " | — | — | — | 12,500 | |
| — | 1.00 | — | — | ||
| "Supply at site, erection, testing and commissioning of wall mounting metallic, 1- phase, double door, MCB Distribution Board 12way having specification Similar to L&T Model No. DBSPN012DDS, powder coated with the supply and fixing of the following, In Coming DP MCB - 40Amps - 1Nos. DP ELCB-100mA, 40Amps - 1Nos. Out Going SP MCB of 6A to 32A - 8 Nos. of as outgoing including internal wiring connection, with earthing / neutral link, din channel complete with all accessories. Copper lugs shall be used for termination of wire in MCB'S and Aluminium sockets for cables termination and plastering and finishing to original level as directed by Engineer In charge." | — | — | — | 14,000 | |
| — | 1.00 | — | — | ||
| "Design, fabrication, supply, erection, testing and commissioning of 14 SWG Indoor type medium voltage main distribution board (Essential) with the following Incoming : 1) 1Nos. of MCCB 4 Pole 200A, 36kA having features/Specification similar to L&T Model No. CM92109OON1OG with Thermal Magnetic Release, adjustable over load, adjustable Shortcircuit. 2) 1 No. of 4 pole 200A on load change over switch having features/Specification similar to L&T Model No. CO22000OOOA. Outgoing 1) 1Nos. of MCCB 4 Pole 125A, 25kA having features/Specification similar to L&T Model No. CM90642OOLO with Thermal Magnetic Release, adjustable over load, adjustable Shortcircuit. 2) 3Nos. of MCCB 4 Pole 100A, 25kA having features/Specification similar to L&T Model No. CM91712OOKOOG with Thermal Magnetic Release, adjustable over load, adjustable Shortcircuit. 3) 1Nos. of MCCB 4 Pole 63A, 25kA having features/Specification similar to L&T Model No. CM91712OOHOOG with Thermal Magnetic Release, adjustable over load, adjustable Shortcircuit. 4) 32A DP MCB - 4 Nos. 5) Multifunction meter - 2 Nos., 6) Suitable length of electrolytic copper busbar (approximate 250 Sq.mm) and other standard fittings conforming to relevant IS, Note:- a) Approximate size of the panel - 1750mm x 1825mm x 320mm (L x H x D)" | — | — | — | 3,60,000 | |
| — | 50.00 | — | — | ||
| Supply and laying of 3core 16sqmm Copper submersible cable including providing suitable waterproof joint if required | — | — | — | 55,650 | |
| — | 100.00 | — | — | ||
| Supply and laying of ISI marked Medium duty PVC rigid wiring conduit pipe of size 20mm dia for Open wiring including, tees, bends, junction boxes etc and finishing to original level & Wall thickness 1.4mm +/- 0.2mm. | — | — | — | 6,000 | |
| — | 10.00 | — | — | ||
| Supply and laying of ISI marked Medium duty PVC rigid wiring conduit pipe of size 25mm dia for Open wiring including, tees, bends, junction boxes etc and finishing to original level & Wall thickness 1.4mm +/- 0.2mm. | — | — | — | 820 | |
| — | 30.00 | — | — | ||
| Supply and laying of ISI marked Medium duty PVC rigid wiring conduit pipe of size 32mm dia for Open wiring including, tees, bends, junction boxes etc and plastering and finishing to original level & Wall thickness 1.4mm +/- 0.2mm | — | — | — | 2,340 | |
| — | 135.00 | — | — | ||
| Supply and Single phase wiring by means of 2 nos. of 1.5 Sq.mm (P&N) and 1 No. of 2.5 Sqmm (Earth) size Flame Retardant Low Smoke & Halogen (FR- LSH) PVC insulated single core multistranded flexible copper cable with ISI mark of approved make with coded color for Phase, Neutral and Earth through already erected PVC casing and capping or pipes, junction boxes, distribution boards etc., | — | — | — | 20,250 | |
| — | 19.00 | — | — | ||
| Supply and fixing of 3 plate ceiling rose as ditected by site engineer incharge. | — | — | — | 1,520 | |
| — | 4.00 | — | — | ||
| Supply & Fixing of 40W LED street light fittings on the Octogonal Poles/Rail Poles/Wall of the building with suitable GI pipe and clamps if necessary. GI pipe has to be bend as directed at site including wiring arrangements/Point wiring to the fittings. | — | — | — | 20,000 | |
| — | 3.00 | — | — | ||
| "Supply and concealing of sheet metal boxes with 6-way module along with modular frame & plate including plastering and finishing to original level. " | — | — | — | 1,674 | |
| — | 1.00 | — | — | ||
| "Supply and concealing of sheet metal boxes with 3-way module along with modular frame & plate including plastering and finishing to original level. " | — | — | — | 423 | |
| — | 15.00 | — | — | ||
| Supply and fixing of modular type one way 6A switch as directed by site engineer incharge. | — | — | — | 1,620 | |
| — | 3.00 | — | — | ||
| Supply at site, fixing of 3pin or 5pin Modular type Socket - 6A with 1Way modular controlling switch of L&T, Legrand make or similar on the already erected modulr control /switch boards including internal wiring [ Socket - 2 Module, Switch 1 Module ] | — | — | — | 1,479 | |
| — | 1.00 | — | — | ||
| Dismatling cables from existing LT panel, AMF panel, pump panel etc..., and handing over the same including dismantling old LT panel, pump panel, oil cooled starters, Stabilizer etc.., from the existing positions | — | — | — | 20,000 | |
| — | 5.00 | — | — | ||
| "Supply and Fixing of 18W to 20W LED batten tube light Luminary.The fittings have to be fixed on the wall/ceiling/PF Shelter with suitable clamps. " | — | — | — | 2,235 | |
| — | 1.00 | — | — | ||
| Supply and fixing of 80W to 90W flood type LED type luminaire on the already erected Dwarf rail poles / 2 way cross arms etc.., As directd by site engineer incharge. | — | — | — | 6,000 | |
| — | 2.00 | — | — | ||
| Supply and fixing of 150mm sweep size BLDC Exhaust fan on the suitable location with clamps including construction of hole on the wall as directed by site Engineer. | — | — | — | 6,550 | |
| — | 5.00 | — | — | ||
| "Supply of Concealed type Earthing. This consisting of supply at site, erection, testing and commissioning of G.I. Earth Electrode 50mm dia, 3000mm long, 'C' class (heavy duty/ISI marked supply and and fixing of earth inspection chamber, lid, as per CEE Drg. No.EL/P/TYPE-1022 with charcol & salt / Bentonite Compound Filling, which includes the cutting and removing of granite / marble / kadappa stone paved platform and cement concreted areas etc., excavation / augering of earth pit by suitable boring equipments. The earth pot shall be provided in level with flooring. The above includes reconstruction of the area of granite / marble / kadappa stone / cement concrete etc.., to bring back to the original condition duly providing granite / marble / kadappa stone / cement concrete etc.., The earth pot shall be painted black and earth value to be recorded" | — | — | — | 35,800 | |
| — | 10.00 | — | — | ||
| "Supply and Single phase wiring by means of 2 nos. of 6 Sq.mm (P&N) and 1 No. of 10 Sqmm (Earth) size Flame Retardant Low Smoke & Halogen (FR- LSH) PVC insulated single core multistranded flexible copper cable with ISI mark of approved make with coded color for Phase, Neutral and Earth through already erected PVC casing and capping or pipes, junction boxes, distribution boards etc., " | — | — | — | 4,520 | |
| — | 3.00 | — | — | ||
| "Supply and fixing of Three Phase Submersible Pump Controller /Starter panel similar to L&T Model No. MU-G40 FASD suitable to operate 40HP open well submersible pump set. The said starter panel has to be consider supply and fixing of digital voltmeter, ammeter, thermal overload Relay, single phase preventer with dry run preventer, ON/OFF push button switch, LED indication for 3-phases, etc..,." | — | — | — | 1,41,513 | |
| — | 2180.00 | — | — | ||
| Removal of OH line conductors (in meters - 1No. of conductor) as directed by site engineer incharge. | — | — | — | 10,900 | |
| — | 22.00 | — | — | ||
| "Removal of existing Rail/RCC/Tubular poles & shifting to the proposed location as directed by site engineer incharge. Note:- Same has to be stacked at suitable location (within 2km) as directed by site engineer incharge." | — | — | — | 33,000 | |
| — | 1.00 | — | — | ||
| "Dismantling of 2 Nos of 160kVA transformer & shifting to the proposed location as directed by site engineer incharge. Note:- Same has to be stacked at suitable location (within 2km) as directed by site engineer incharge." | — | — | — | 11,922 | |
| — | 2.00 | — | — | ||
| "Dismantling of existing 4 Pole structure (Rail/RCC) & shifting to the proposed location as directed by site engineer incharge. Note:- Same has to be stacked at suitable location (within 2km) as directed by site engineer incharge." | — | — | — | 33,778 | |
| — | 1.00 | — | — | ||
| Supply and Fixing of heavy duty Power Factor Correction Capacitors of capacity 12.5kVAR as directed by site engineer incharge. | — | — | — | 6,588 | |
| — | 2.00 | — | — | ||
| "Supply, Erection, Testing and Commissioning of 12m Double Pole structure (by using A Pole) inclusive of 11kV, 400A D/B GOS, Post Insulator, Pin Insulator, Disc Insulator, 1set of Lightning Arrester, 0SWG Electrolytic Solid Copper Rods, Anticlimbing Devise, Channel cross arms and angle cross bracings etc,,. confirming to KSEBL Standards inclusive of all accessories such as clamps, bolts, nuts, washers etc.., and painting with two coats in each of primer zinc chromate and aluminium paints. Note:- 1) Necessary drawing approval may be obtained before commencement of work. 2) This scope of work includes supply, erection & testing and commisioing of 2 Nos of 9m/11m A pole." | — | — | — | 1,92,206 | |
| — | 100.00 | — | — | ||
| Excavation of cable trench in all kinds of soil up to a depth of 1.0 Mtr. & Width of 0.3 Mtr duly clearing the roots of trees etc. and refilling with the excavated soil up to normal level. Depth and Width can be varied based on site Condition as directed by site engineers in charge. Concerned Measurement will be taken in Cubic meters. | — | — | — | 50,000 | |
| — | 3.00 | — | — | ||
| Breaking of cement concrete flooring and finishing to original level by cement concrete in an approved manner | — | — | — | 15,000 | |
| — | 5.00 | — | — | ||
| "Supply at site & placing of flat type cable route indicator at regular intervals on straight route and one each at every route diversion from straight line as directed by site engineer. The said cable Route Indicator has to be grouted in a concrete mix of ratio 1:3:6with 300mmX200mmX300mm size." | — | — | — | 4,080 | |
| — | 260.00 | — | — | ||
| "Laying HT XLPE UG cable of sizes beyond 3x185 sq mm and upto and including 3x300 Sq.mm including conveying cable from Sub Regional Store/stacking place to work site and laying it carefully using cable rollers, taking through stone ware/G.I Pipes at road crossing / culverts / bridges etc.., where ever necessary, providing identification tags at 5m intervals, filling the space around the cable with riddled soil and covering the top with bricks, providing cable route markers at 100m intervals, inclusive of cost of all materials (other than cost of GI/HDPE pipe & UG Cable), labour and transport including crane charges excluding excavation and backfilling Note: - Cable will be supplied by Railway from the Office of SSE/Electrical/W/PGT." | — | — | — | 3,90,000 | |
| — | 1.00 | — | — | ||
| "Supply, Erection, Testing and commissioning of Horizontal end suction type pump having features/Specification similar to kirloskar make Model No. DB 100/40XE, with CI casting, CI impeller, CS shaft, Gland Packed Coupled to 22kW/30HP, 1475RPM TEFC Squirrel cage induction motor having features/Specification similar to Kirloskar make on a common base frame with coupling and coupling guard Suitable for 2200 LPM @ 40 meter head. Suitable Starter panel with Ammeter, volt meter, dry run preventor, single phase preventor etc.., has also to be Supplied and fixed as directed by site engineer incharge. Suitable foundation for the said Booster pump to be provided by the contractor as directed by site engineer incharge. Note:- 1) 1 No. of CI type NRV & 2 Nos of coupler has to be supplied by the contrcator. 2) 4 inch Delivery & 6 inch suction (Approximate) for the said pump shall ensured. 3) Scope of work including Supply, Erection, Testing & Commissioning of said induction motor & coupled Pump suitably aligned on a common frame work ." | — | — | — | 5,50,000 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .