| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.6 LAccepted-AOC D NO 35 14 13 1 R P PETA KANCHARAPALEM VISAKHAPATNAM 530 008 | VISAKHAPATANAM | ANDHRA PRADESH | 530008 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹25.6 L+₹2.6 L (11.4%)Rejected-Finance | L2 | Rejected-Finance Being not L1 | |
| 3 | L3₹27.8 L+₹4.8 L (20.7%)Rejected-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | L3 | Rejected-Finance Being not L1 | |
| 4 | L4₹32.9 L+₹9.9 L (42.8%)Rejected-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | BAPATLA | ANDHRA PRADESH | 504214 | L4 | Rejected-Finance Being not L1 | |
| 5 | L5₹33.0 L+₹10.0 L (43.4%)Rejected-Finance HOUSE NO 36 93 354 9 INDIRA NAGAR 5 NH 16 KANCHARAPALEM POST VISAKHAPATNAM 530 008 | VISAKHAPATANAM | ANDHRA PRADESH | 530008 | L5 | Rejected-Finance Being not L1 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
29 Nov 2021, 6:00 pmClosed
Garrison Engineer Utility-I Visakhapatnam
Garrison Engineer Utility-I Near Samudrika Naval Base Post Visakhapatnam -530 014
REPAIR MAINT TO LT UG CABLES, LT PANELS and SWITCHGEARS AND OTHER ELECTRICAL WORKS AT NAD TECHNICAL AREA AND NAD RESIDENTIAL AREA UNDER AGE E/M NO-II OF GE (U-I) VISAKHAPATNAM
2021_MES_487289_1
8358/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Garrison Engineer Utility-I
CLASS D
8 documents required · 8 mandatory
₹500
Garrison Engineer Utility-I
₹80,000
Yes
16 Dec 2021
9 Nov 2021
30 Nov 2021
9 Nov 2021
29 Nov 2021
24 Nov 2021
Amount
Excavation in trenches n.exc 1.5 m wide and not exc 1.5 m depth and getting out in soft / loose soil complete all as specified and directed.
Returning and filling in of excavated material any type including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each complete all as specified and directed.
Removal of surplus excavated material of any type to a distance not exceeding 50 m and depositing where directed at a level not exc. 1.5 m above the starting point complete all as specified and directed.
Supply and spreading clean dry sand for cable cushioning in trenches complete all as specified and as directed. (Note: Punned thickness only shall be measured)
Supply and laying sub class 'B' bricks of old size (approved size locally available) laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge
M&L for GI pipe light grade 50 mm dia laid along road crossings / plinth protection with suitable fittings for cable protection or fixed to the pole/ Wall complete all as specified and directed by Engineer-in-Charge . Make : Surya Roshni Ltd / Tata / Jindal steel / Prakash
M&L for GI pipe light grade 80 mm dia laid along road crossings / plinth protection with suitable fittings for cable protection or fixed to the pole/ Wall complete all as specified and directed by Engineer-in-Charge . Make : Surya Roshni Ltd / Tata / Jindal steel / Prakash
Cutting the tarmac / hard standings and excavating in trenches across the road with a size not exceeding 0.45 m wide and 0.6 m depth for laying cable including making good the excavated portion by means of PCC 1:3:6, type C1 matching with the surroundings complete all as specified and as directed.
Supply laying, testing and commissioning LT XLPE insulated , armoured heavy duty electric FRLS cable of following sizes, 1100 volts grade with stranded aluminium conductor laid in trenches / passing through pipe / duct/ road crossing /fixed on poles / walls Complete all as specified and directed. MAKE: Havells / Gloster / KEI Industries Ltd / Polycab / Asian Cables / Finolex [Note: The rate quoted shal bel inclusive of termination at ends with suitable aluminium lugs where required]
10 Sqmm 4 core
16 Sqmm 4 core
25 Sqmm 4 core
35 Sqmm 3.5 core
50 Sqmm 3.5 core
70 Sqmm 3.5 core
95 Sqmm 3.5 core
120 Sqmm 3.5 core
150 Sqmm 3.5 core
185 Sqmm 3.5 core
240 Sqmm 3.5 core
Supply and fix in repairs Air Circuit Breaker 4 Pole, 415 V, with Thermal Magnetic Release (Manual Fixed type) of rating 800 Amps, breaking capacity 50 KA Complete all as specified and directed. Make: HPL/C&S/Schneider/L&T/ Indoasian/GE/Havells
Supply and fix MCCBs of following current carrying capacity including necessary modification in the panel and taking down existing one complete all as specified and as directed. Make: GE/L&T/Havells/Indoasian/HPL/standard
3 Pole MCCB 320-400 Amps, Adjustable type,415V, 36 KA rating
3 Pole MCCB 250 Amps, Adjustable type, 415 V, 36 KA rating
3 Pole MCCB 200 Amps, Adjustable type, 415 V, 36 KA rating
3 Pole MCCB 160 Amps, Adjustable type, 415 V, 36 KA rating
3 Pole MCCB 100 Amps, Adjustable type, 415 V, 36 KA rating
3 Pole MCCB 125 Amps, Adjustable type, 415 V, 16 KA rating
4 Pole MCCB, 415 V, Adjustable type with breaking capacity 35 KA, 400 A rated
4 Pole MCCB, 415 V, Adjustable type with breaking capacity 25 KA, 250 A rated
4 Pole MCCB, 415 V, Adjustable type with breaking capacity 25 KA, 200 A rated
4 Pole MCCB, 415 V, Adjustable type with breaking capacity 25 KA, 160 A rated
4 Pole MCCB, 415 V, Adjustable type with breaking capacity 25 KA, 100 A rated
Supply and fix in repairs Isolator 415 Volts of following current carrying capacity. Make: GE/L&T/Havells/Indoasian/HPL/standard
4 Pole 63 Amps
4 Pole 100 Amps
TPN 63 Amps
TPN 100 Amps
M&L for detecting LT UG cable faults located in any stretch/ depth with sophisticated cable fault locator consisting of microprocessor based pre-locator system, HV surge generator, fault pin point surge wave reciever, cable indentification instrument , cable tracer for exact location of under ground cable routes. Note: The rate quoted deemed to be inclusive of transportation of equipment and charges for service engineer. The fault locator shall be arranged by contractor only.
Supply, fixing and testing straight through joint heat shrinkable type with jointing kit suitable for cable XLPE of size 3.5/4 core 25 to 50 sq mm, insulated armoured heavy duty aluminium conductor 1100 Volts grade complete all as specified and directed. Make: 3M / Denson / M-Seal / Raychem
All as per Item No.14 herein before but for cable of size 3.5 core 70 to 150 sq.mm.
All as per Item No. 14 herein before but for cable of size 3.5 core 185 to 300 sq.mm.
Supply, fixing and testing heat shrinkable type end termination joint kit, suitable for cable XLPE of size 3.5 / 4 core 50 to 95 sq mm , insulated armoured heavy duty aluminium conductor 1100 Volts grade complete all as specified and directed. Make: 3M / Denson / M-Seal / Raychem
All as per Item No.17 herein before but for cable of size 3.5 core 120 to 185 sq.mm.
Disconnecting, dismantling of existing feeder pannel and supply, fabricate, install, testing and commissioning of LT feeder panel board of suitable size, out door type double door, dust and vermin proof made out of 3.15 mm thick MS sheet mounting on suitable size foundation with 150 mm thick PCC (1:3:6) type C 2 with 100 mm offsets and panel board with front and back opening and locking arrangement compete two coats of finishing powder coated paint of approved shade over one coat of Zinc chrome red oxide primer including horizontal busbar of aluminium strip suitable size for three phase 4 wire including the following accessories and fitted in complete all as specified and directed : - (a) Incomming: MCCB 4 pole 415 volt 35 KA breaking capacity adjustable thermal release range 320 amp -01 No.
(b) Outgoing: (i) MCCB 3 pole 415 volt 25 KA breaking capcity adjustable thermal release range 125 amp – 04 Nos (ii) Multifunnction Meter, Phase Indicator (R, Y & B) Makes : (i) MCCB/MCB : Legrand / L & T / Siemens / ABB / C & S / Schneider / GE (ii) Volt Meter/Ammeter : Havells / HPL / L & T / AE / Schneider / BCH
Disconnecting, dismantling of existing feeder pannel and supply, fabricate, install, testing and commissioning of LT feeder panel board of suitable size, out door type double door, dust and vermin proof made out of 3.15 mm thick MS sheet mounting on suitable size foundation with 150 mm thick PCC (1:3:6) type C 2 with 100 mm offsets and panel board with front and back opening and locking arrangement compete two coats of finishing powder coated paint of approved shade over one coat of Zinc chrome red oxide primer including horizontal busbar of aluminium strip suitable size for three phase 4 wire including the following accessories and fitted in complete all as specified and directed : - (a) Incomming : (i) ACB 4 pole 415 volt 35 KA breaking capacity adjustable thermal release range 800 Amp -01 No
(b) Outgoing : (i) MCCB 3 pole 415 volt 25 KA breaking capacity adjustable thermal release range 400 Amp – 01 No (ii) MCCB 3 pole 415 volt 25 KA breaking capacity adjustable thermal release range 250 Amp – 03 Nos (iii) MCCB 3 pole 415 volt 25 KA breaking capacity adjustable thermal release range 40 Amp – 2 Nos (iv) Multifunnction Meter, Phase Indicator (R, Y & B) Makes : (i) ACB/MCCB/MCB : Legrand / L & T / Siemens / ABB / C & S / Schneider / GE (ii) Volt Meter/Ammeter : Havells / HPL / L & T / AE / Schneider / BCH
Disconnecting, dismantling of existing feeder pannel and supply, fabricate, install, testing and commissioning of LT feeder panel board of suitable size, out door type double door, dust and vermin proof made out of 3.15 mm thick MS sheet mounting on suitable size foundation with 150 mm thick PCC (1:3:6) type C 2 with 100 mm offsets and panel board with front and back opening and locking arrangement complete two coats of finishing powder coated paint of approved shade over one coat of Zinc chrome red oxide primer including horizontal busbar of aluminium strip suitable size for three phase 4 wire including the following accessories and fitted in complete all as specified and directed : - (a) Incomming: (i) MCCB 4 pole 415 volt 35 KA breaking capacity adjustable thermal release range 100 amp – 01 No
(b) Outgoing: (i) MCCB 3 pole 415 volt 25 KA breaking capacity adjustable thermal release range 63 amp – 07 No. (ii) Multifunnction Meter, Phase Indicator (R, Y & B) Makes : (i) MCCB/MCB : Legrand / L & T / Siemens / ABB / C & S / Schneider / GE (ii) Volt Meter/Ammeter : Havells / HPL / L & T / AE / Schneider / BCH
Disconnecting, dismantling of existing feeder pannel and supply, fabricate, install, testing and commissioning of LT feeder panel board of suitable size, out door type double door, dust and vermin proof made out of 3.15 mm thick MS sheet mounting on suitable size foundation with 150 mm thick PCC (1:3:6) type C 2 with 100 mm offsets and panel board with front and back opening and locking arrangement compete two coats of finishing powder coated paint of approved shade over one coat of Zinc chrome red oxide primer including horigental busbar of aluminium strip suitable size for three phase 4 wire including the following accessories and fitted in complete all as specified and directed : - (a) Incomming: MCCB 4 pole 415 volt 50 KA breaking capacity adjustable thermal release range 400 amp -02 Nos. (ii) On load change over switch 415 volt, 400 amp – 01 No
(b) Outgoing: (i) MCCB 4 pole 415 volt 35 KA breaking capacity adjustable thermal release range 250 amp – 02 Nos. (ii) Multifunnction Meter, Phase Indicator (R, Y & B) Makes : (i) MCCB/MCB : Legrand / L & T / Siemens / ABB / C & S / Schneider / GE (ii) Volt Meter/Ammeter : Havells / HPL / L & T / AE / Schneider / BCH
M&L for earthing complete with GI earth plate electrode of size 60cm x 60cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5m below the normal ground level connected with GI strip 32 x 6mm by means of bolts, nuts, check nuts & washers of galvanished iron steel including necessary excavation and earth work in any type of soil, removing surplus soil to a distance not exc 50m, with and including PCC chamber in PCC (1:2:4), type B1,using (20mm graded stone aggregate), "mild steel angle iron frame" made out of MS angle iron of size 40x 40 x 6 mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6mm thick CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 20mm dia medium grade pipe for watering 40mm dia light grade, GI pipe for lead protection in & including alternate layers of charcoal dust and common salt complete all as shown in electrical "plate No '3' of SSR Part-I and connected to earthing test point all as specified and indicated including testing on completion including retrieving old GI earth plate, CI cover, GI pipes, angle iron frame from existing earthing as directed.
M&L for Maintenance and attending complaints / breakdowns at NAD Technical area and NAD Residential area comprising of LT panels, over head lines/ underground LT cables upto main distribution boards at buildings including repairs of day to day maintenance of LT panels/Perimeter lights for smooth & trouble free LT power supply as directed by Engr-In-charge including rectification of minor defects to electrical controls gear/accessories.
Note : The rate quoted is inclusive for the following :- (i) (a) Attending minor repairs/breakdowns without involving any new (major) materials. (b) Cost includes the tools for attending break down and minor materials like lugs and PVC tapes,Job Cards and Complaint registers etc. (c) Major repairs,Break downs invloving S&F of materials such as cables,Joints,MCCBs etc are out side the scope of this item and shall be measured and paid separately.
(ii) Contractor should ensure to carry out the work through qualified Technician/Electrician and assisted by the helper. Necessary tools & plants and transportation charges are deemed to be included in the unit rate quoted. (iii) On completion of the task/attending break down necessary Job card shall be submitted duly signed by the stake holder.
Cuting of trees / bushes in surrounding of LT Panels of any size and complete cleaning of grass upto 1.5 m radius area around the panel in every quarter i.e for 3 Months complete all as directed
Excavation of cable size 70 Sqmm to 300 Sqmm from its loop, cleaning, cutting of old termination kit and refill of termination kit of suitable size alongwith refilling of cable with sand and bricks.
DELTA CONSTRUCTIONS
SRI SRK ENGINEERS
M/S SRI VENKATA BHAVANI CONSTRUCTIONS
SAMPATH ENTERPRISES
LEOENTERPRISES
VENKATESWARA ENGINEERS AND CONTRACTORS
PRADEEP ENTERPRISES
SRIESWARI ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .