CWE (AF) JODHPUR
HQ CWE (AF) JODHPUR
REPAIR/REPLACEMENT AND SERVICING PARTS OF AC PLANTS, VRVS AND ALLIED WORKS AT AF STATION JODHPUR
2020_MES_337736_2
85841/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) JODHPUR
Please ref tender documents
7 documents required · 7 mandatory
₹500
GE (AF) JODHPUR
₹70,000
Yes
30 Jun 2020
16 May 2020
8 Jun 2020
16 May 2020
6 Jun 2020
25 May 2020
60 days
Amount
M & L for servicing of water cooled reciprocating chiller unit capacity 60 TR make: Voltas model No. 5 H 66.(auditorium) first checking of all safety controls & setting parameter, electrical panels pneumatic testing and leak testing ,before start over hauling first to do proper pump down the compressor unit and drainout the old compressor oil ,cleaning the oil chamber and replacement of defective compressor assessories and reassembling the compressor after over hauling, charging the compressor fresh oil, start & testing the compressor net oil, off load & full load testing completely up to entire satisfaction of Engineer-in-Charge. NOTE:- (i) The spare parts required for replacement shall be measured and paid separately as supply only. (ii) All spare parts shall be of make Voltas.
(a) supply & fix oil filter
(b) supply and fix liquid line strainer
(c) supply and fix pressure transducer 0-30 BAR AKS 3000(060G1081)
(d) supply and fix solenoid valve with coil 220v
(e) supply and fix oil pump
(f) Supply only oil seal
(g) Supply only oil seal plate
(h) supply and fix saftey valve size 5/8"
Ditto all as per Ser item No 1.00 above but (IACCS 33 SU) capacity 50 TR make:voltas model no. 5 H 60(IACCS 33 SU)
(a) supply & fix oil filter
(b) supply and fix liquid line strainer
(c) supply and fix pressure transducer 0-30 BAR AKS 3000(060G1081)
(d) supply and fix solenoid valve with coil 220v
(e) supply and fix oil pump
(f) Supply only oil seal
(g) Supply only oil seal plate
(h) supply and fix saftey valve size 5/8"
Supply and charging of compressor oil (mineral) suitable for voltas water cooled recirocating chillers model 5H 60/5 H 66
Supply and charging for refrigerant R-22 Gas (Make:- Mafron/ Feron/floron ) complete all as specified and directed.
M&L for replacement of micro processor controller panel, suitable for voltas water cooled recirocating chillers model 5H 60/5 H 66 Digital display of all vital parameter for water cooled reciprocating pkg chiller plant 50 TR as per sample Model No-VLRP SINGLE V2A,Type -DELUX Range-6/5/4 ,Aux supply-8v &12 V, Make-SOFTHARD or equivalent complete all as specified and directed.
M & L for replacement of microcomputer voltage protection device(MVPD) with display complete model-EC, Type-MVPD, Range 30-220 Amps,Aux supply-230V,Special -5 sec Curve MPD make -SOFTHARD.
Material & Labour for finding out the leakage with the pressure test of scroll compressor circuit unit capacity up to11 TR, identifing gas and oil leakage and removing the same and Leak repairing by brazing/flaring and flushing the sysytem by nitrogen gas and pressure testing for leakage and rectified and after rectification vacumacation, pressure testing, and gas charging R-407c for achieve desire pressure and testing complete to the entire satisfaction of Engineer-in-Charge NOTE :- Gas charging required shall be measured and paid separately as supply only.
Ditto all as per Ser item No 7.00 above but capacity up to11 TR to 25 TR,
Ditto all as per Ser item No7.00 above but capacity up to 25 TR to 50 TR,
Material and labour for Repair of chiller unit capacity up to 25 TR with Nitrogen pressure testing ,removing of end shield of evaporator and condenser to check and repair of leakage , plugging of tubes ,dismantling the defective compressor and replace the same with new one refrigerant charging and re commissioning of the chiller and compressor and gas charging R-407c for achieve desire pressure and testing complete to the entire satisfaction of Engineer-in-Charge NOTE :- Gas charging required shall be measured and paid separately as supply only.
M&L for taking out unserviceable sealed unit (compressor) as existing and replacing the same with new packaged type sealed unit (compressor) 12.5 ton capacity ,model-SZ185S4RC , three phase, 415 volt of models Danfoss make including necessary modification of the foundation as required to suit the compressor, flushing the sysytem by nitrogen gas and pressure testing for leakage and rectified (by brazing) and after rectification vacumacation, pressure testing, and gas charging R-407c for achieve desire pressure and testing complete to the entire satisfaction of Engineer-in-Charge NOTE :- Gas charging required shall be measured and paid separately as supply only.
M&L for charging of refrigerant R-407c Gas . (Make:- Mafron/ Feron/floron/du point) complete all as specified and directed
M&L for replacement of pilot solenoid valve suitable for water cooled scroll chiller unit cap 25/37/50 TR all as per specified and directed.
M&L for replacement of solenoid coil220v suitable for water cooled scroll chiller unit cap 25/37/50 TR all as per specified and directed.
M&L for replacement of thermostatic expansion valve suitable for water cooled scroll chiller unit cap 25/37/50 TR all as per sample, including brazing at both ends all as required and directed.
M & L for replacement of HP/LP switch suitable for scroll compressor cap up to 12.5 TR all as per specified and directed.
M&L for replacement of Drier filter suitable for Package type AC Plant size 5/8" Make: Catch All Model : C-165
M&L for replacement of chilled water sensor complete all as specified and directed
M&L for replacement of old unservicable pressure relief valve of condenser 5/8" BSP threaded suitable for 300 PSI complete all as specified and directed
M&L for replacement of pressure transducer range 18 bar/30 bar connection type 1/4 BSP make :meas
M&L for replacement of micro processor controller panel, Digital display of all vital parameter for water cooled scroll type chiller plant as per sample Model No-SCR44TR(MPD) ,Type -DELUX Range-5-30 Amp , Make-SOFTHARD or equivalent complete all as specified and directed
M&L for replacement of micro processor controller panel VLRP, Digital display of all vital parameter for water cooled scroll type chiller plant cap 22TR as per sample Model No-V3A ,Type -DELUX Range-16/4/12 ,Aux supply -15 VAV , Make-SOFTHARD or equivalent complete all as specified and directed
M&L for replacement of micro processor controller panel VLRP, Digital display of all vital parameter for water cooled scroll type chiller plant cap 11TR as per sample Model No-V3A ,Type -DELUX Range-7/2/2 Aux supply -15VAV , Make-SOFTHARD or equivalent complete all as specified and directed
M & L for replacement of microcomputer voltage protection device(MVPD) with display complete model-EC, Type-MVPD, Range 5-30 Amps,Aux supply-230V,Special -5 sec Curve MPD make -SOFTHARD or equivalent complete all as specified and directed
Supply and fix in replacement of HMI (SCR44TR) display make softhard forwater cooled scroll chiller unit .
M&L for repairs of condenser/chiller pumps from 2HP Upto 7.5 HP including dismantling of Pump of following capacity and segregating to its parts for repairs and maintenance, replacement only of shaft bearing, impeller key, shaft sleeve, impeller and grinding / polishing, bend removing etc complete including painting by two coats of synthetic enamel paint reassembling of pump after completion of work & testing complete all as per direction and satisfaction of Engineer in charge. Note:- Supply only of bearing and sleeve, impeller will be measured and paid under relevent item of work.
Supply and fix in replacement of srare parts of pumps sets (To be incorporated under respective item above ) :- (a) Shaft bearing as per existing specifications.
(b) Shaft sleeve as per existing specifications.
(c) Impeller with key as per existing specifications.
(d) Mechanical Couplings as per existing specifications.
(e) rubber type coupling as per existing specifications.
M & L for repairing /Disconnecting the electrical and mechanical connection of burnt electrical motors from the site / location, transporting to and from to work shop. Rewinding of electrical motors/ pump motors by dismantling and removing the burnt cut copper winding wire cleaning the slots of stator with petrol and brushes winding polyster based super enamelled copper wire of same gauge of original one with proper class of insulation including varnishing and heating the coil and remove air bubbles complete stator / roter after rewinding reassembling all parts including reinstalling connection to original position and testing on full load all as directed by Engineer in charge for different capacity of motor as per following :- (a) 1 to 2 HP
(b) 3 to 5 HP
(c) 7.5 to 15 HP
(e) 50 to 100 HP
M&L for replacement of Hexagonal Green Plastic Wire Mesh for cooling tower as per sample and directed by ENGG -IN CHARGEH
M&L for replacement ofThermostat Honey well 0-30 degree C
M&L for disconnecting electrical connections motor located at the top of cooling tower,keep cables at safe custody for reconnection and dismantling and taking out fan blade assembly along with motor mounted on base frame at the top of cooling tower after cutting/dismentaling all nuts, bolts and fixtures from the mounting frame and removing whole assembly including motor and base frame from the top of cooling tower with the help of T&P for servicing of cooling tower suitable for 100-120 TR capcity including following complete:- (i) Cleaning /scrapping of inner& outer surface of FRP basin, repair of damaged portion if any incuding FRP lining of all surfaces joints to avoid leakage including replacement of all nuts and bolts joining all parts of Basin complete. (ii) servicing cooling tower plant through cleaning re-agent complete pipe line, including servicing of cooling tower motor and fan and make the necessary alignment with motor. (iii) replacement of bearing if any of suitable cap if any after necessory work including gressing and replacement of nut bolts and preventing leakage if any by means of suitable adetives etc all as directed and specified. (iv) taking out PVC fills blocks, cleaning and refixing as per existing location and channel direction if pvc fills vintage then replace with new one measure seprately . (v) servicing of spray header and sprinkler assy complete. (vi) repair of water strainer complete.
32.Ditto all as per Ser item No 31.00 above but cooling tower suitable for 25- 60 TR capcity
33.Supply only spare parts of cooling tower of capacity 15 TR to 150 TR for the following Make : Kool Drop / MIHIR / ADVANCE / HIMGIRI. (To be incorporated under item above :- (a) cooling tower PVC fills in colums of size 600mm x 300mm x 150mm size and min wt 600 gram as per existing specification and requirement.
34.supply and fix in replacement of Cooling Tower Sprinkler Assembly such as Sprinkler, Sprinkler Pipe, Elimentor, Tension bar and Turn buckle for Cooling Tower capacity 120 TR model no 9062 make :-MIHIR or equivalent suitable as per existing and ali as per directed by engg in charg
35. supply and fix in replacement of Cooling Tower Sprinkler Assembly such as Sprinkler, Sprinkler Pipe, Elimentor, Tension bar and Turn buckle for Cooling Tower capacity 50 TR/30 TR model no 5051 ,model no 5022 &model no 5021 make :-Delta or equivalent suitable as per existing and ali as per directed by engg in charg
Cooling tower PVC nozzles size 2" dia suitable as per existing al as per directed by engg in charge.
Roler bearing/Pedestal bearings for fan motor as per sample of make SKF/AKB
Ball / Roller bearing for Sprinlkler top and Bottom Hub for 25 TR to 120 TR capacity .
M& L for coating FRP lining of 6 mm thickness on cooling water piping near cooling towers to minimize corrosion of MS piping of 125/100/80 mm diameter complete all as per specified and directed.
S&F in replacement of of PN 1.6 butterfly valves size 125 mm duly insulated with companion flanges,nuts,bolts,gaskets etc.as specified . butterfly valves with cast iron body, seat of black nitrile rubber ,nylon coated S.G.iron disc,epoxy powder coated shaft AISI 410 etc.complete all as specified and directed. Make Audco/castel/kirloskar
Ditto all as per Ser item No 40.00 above but size 100mm.
Ditto all as per Ser item No 40.00 above but size 80mm.
Ditto all as per Ser item No 40.00 above but size 65mm.
Ditto all as per Ser item No 40.00 above but size 50mm.
Ditto all as per Ser item No 40.00 above but size 40/32mm
Material and labour for replacement of rotational moulded polyethylene water storage tank (cylinderical vertical with closed top) of cap 5000 ltrs hoisted and fixed in position all as specified in SSR Part-I
Ditto all as per Ser item No 46.of cap 500 ltrs.
Pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width and setting in mortar,complete 1:2:4 type B1 of 20 mm greaded aggregate for foundation of any requirements as per directed by engg in charge .
M & L for Descaling the condenser by descaling compound / hydrochloric acid by soaking method,disconnecting condensor from the system by taking out nuts, bolts, studs, valves and MS/GI pipe line from both side cover, cleaning each tube with nylon brush,flushing with alkaline solution,connecting back both side cover including replacingleather gasket 4 mm thick for following capacities of condensers suitable for AC Plant installed as indicated below complete all as specified and directed and all as per manufacturers instruction and to the entire satisfaction of Engineer-in-charge. (a) chiller unit cap 60 TR (Auditorium)
b)Ditto all as per Ser item No 49.00 above but chiller unit cap 50 TR (IACCS 33SU, ILS)
c)Ditto all as per Ser item No 49.00 above but chiller unit cap 37 TR( ccc & FMS )
d)Ditto all as per Ser item No 49.00 above but chiller unit cap 25 TR (23MMPU,parachute,EW lab &instrument lab)
e)Ditto all as per Ser item No 49.00 above but chiller unit cap 11 TR(ACMI, Base opps,bomb dumpem25 &em26)
f)Ditto all as per Ser item No 49..00 above but chiller unit cap 7.5 TR(bomb dump)
M&L for servicing and cleaning of AHU cooling coil 4-6 rows deep of capacity 8000cfm to 18000 cfm through cleaning agent and remove the oil and dust from fins and cooper tubes/ pipes complete checking of copper tubing for leakage maching/ repairing /brazing of leakaged tubes complete including sealing of joints all as directed by engineer in charge.
S&F in replacement of air filter for AHU, Filter section consists of 50 mm thick washable HDPE 90% down 10 micron Pre-Filters, AHU pre filter having HDPE media with aluminium / GI frame & filter as per the existing size of 600mmX600mmX50/40 mm mm complete all as specified and directed. (Make :- Supreme/Athlete or equivalent
M&L for replacement of' V Belt of A & B Series any sizes for AHU 's as per site requiement complete all as specified and directed
M&L for repair of ducting insulation made out of fiber glass wool roll of density 24 kg/cum of thickness of insulation 50 mm including jointing with propper sealing against any leakges and applying rubber based adhesive CPRX compound,sealing of all longitudinal joints and circular overlaps with and including aluminium foil tape 50 mm wide to make the insulation leak proof,securing the insulation with and including mechanically fastened nylon / steel straps of size 12 mm/50 mm at maximum intervals of 1.2 mtr complete all as directed by Engineer-in-charge.
M&L for repair of chilled water piping size 80 /100 mm duly insulated 50 mm thick TF quality EPS pipe section insulation of 18 kg/cu.mt density & covered with GI chicken wire mesh and two coats 12mm sand cement plaster as per specification complete all as specified and directed by engg in charge.
Supply and fix in replacement of water presuure gauge 0-7 kg / cm2 including Female Stainless Steel Gauge Fittings, Material Grade: SS304 type Make Febig or equivant suitable makes as per appx 'B' complete all as specified and directed
S&F in replacement of thermometer to condenser/chiller, inlet or outlet water pipes including addition alteration to pipe line for fixing thermometer Range 0-100 degree F / degree centigrade complete all as specified and directed
M&L for replacement of 25 mm dia. Auto Air Purge valve for chilled water piping complete all as specified and directed.
M&L for replacement of butter fly valve 15 mm dia complete all as specified and directed..
S&F in repair MS pipe medium grade welded in shape i.e bend . Elbow. Tee. flange etc for condensser and water pipe laid on floor, ground including making hole in wall, brics work and welding of nipple for installing of pressure gauge, thermameters , plug cock etc , duly painted over a coat of red oxide complete all as specified and directed of follwing sizes. 80mm dia.
Supply and fix steel water Tubing medium grade with all fitting laid in wall/trenches (a) 15 mm dia
(b) 25 mm dia
S&F in repairs worn out HRC fuses (Cylindrical / DIN type / Bolted) conforming IS 13703 Part - II with high breaking capacity suitable for existing holders all as specified and as directed for the following capacities :- (a) 10 Amps to 100 Amps
Supply & laying in replacement LT cable XLPE insulated , armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area of size 3.5 core x 70 sqmm complete all as specified and directed
Supply & laying in replacement LT cable XLPE insulated , armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area of size 3.5 core x 50 sqmm complete all as specified and directed
Supply and fix in replacement of PVC insulated 4 Core copper Cable of size 16 Sqmm complete all as specified and directed
S&F in replacement of Digital AC Voltmeter input 0-60 VAC,Range1%-150% of input complete all as specified and directed
S&F in replacement of Digital AC Ammeter input programmable (1A to 5A) Range2%-12% of input complete all as specified and directed
M&L for replacement of Indicating Light, 240V AC, LED Type Red, Yellow, Blue complete all as specified and directed
M&L for replacement of Mushroomhead Push Button, Press to Lock Turn To Release complete all as specified and directed
M&L for replacement of ON/OFF Push Button complete all as specified and directed
M&L for replacement of repair of thermal Relay MNX 32A 3-6 Amp complete all as specified and directed
M&L for replacement of thermal Relay MNX 32A 6-10 Amp complete all as specified and directed
M&L for replacement of MNX -A1 size contactor complete all as specified and directed
M&L for replacement of MNX -A2 size contactor complete all as specified and directed
M&L for replacement of MNX 32A contactor with NO/NC switch complete all as specified and directed
M&L for replacement of MNX 18A contactor with NO/NC switch complete all as specified and directed
M&L for replacement of MNX 12A contactor with NO/NC switch complete all as specified and directed
M&L for replacement of Timer GIC star/delta complete all as specified and directed
M&L for replacement of connector for suitable to chiller panel complete all as specified and directed
M&L for replacement of starter block contactor 3TF34-C3 with NO/NC switch complete all as specified and directed
M&L for replacement of starter block contactor 3TF43-C3 with NO/NC switch complete all as specified and directed
M&L for replacement of starter block contactor 3TF46-C3 with NO/NC switch complete all as specified and directed
Supply and Fixing in replacement of MCCB 400 Amp 4Pole 50 KA complete all as specified and directed
Supply and Fixing in replacement of MCCB DU 250 Amp 4 Pole 35 KA complete all as specified and directed
Supply and Fixing in replacement of MCCB DU 160 Amp 4 Pole 35 KA complete all as specified and directed
Supply and Fixing in replacement of MCCB DU 100 Amp 3 Pole 25 KA complete all as specified and directed
Supply and Fixing in replacement of MCB TP C63 Amp 415 Volt complete all as specified and directed
Supply and Fixing in replacement of MCB TP C40/32 Amp 415 Volt complete all as specified and directed
M&L for replacement of remot control hand set complete for ductable AC 5.5/8.5/11 TR with suitable size of copper conductor cord for operation of AC & having provn of display for current ,room temp fault diagnosis i.e reverse phasing single phasing sensor fault over voltage &under voltage completeall as specified and directed by Engineer-in-Charge.
M&L for taking out unserviceable sealed unit (compressor) 5 ton capacity , three phase, 415 volt of models as existing and replacing the same with new packaged type sealed unit (compressor) of Hitachi/Danfoss make including necessary modification of the foundation as required to suit the compressor, vacumacation, pressure , testing, leaking, rectification including gas charging R-22 for achieve desire pressure and testing complete to the entire satisfaction of Engineer-in-Charge
S&F in replacement of PCB control card with outer & inner set complete suitable for 5.5 TR ductable AC all as specified and directed by Engineer-in-Charge.
M&L for any size of ductable AC servicing of indoor and out door unit and finding out the leakage the pressure test of the condenser of cooling coil of ductable type AC of any capacity and dismantling the same for repair the leakage point by brazing/soldering including charging the gas R-22/410, taking down/refixing the inner unit/outer unit and testing the AC to the entire satisfaction of Engineer-in-Charge.
M&L in repair of PCB control card with outer & inner set complete suitable for any type ductable AC of any capacity requirement complete and testing the AC after the replacement of PCB as specified
M&L for replacement of Indoor blower fan motor of capacity 5.5Ton, suitable for ductable AC cooling coil (as per sample ) complete all as specified and as directed by Engineer-in-Charge. Make - Hitachi/Danfoss/Tecumesh
M&L for replacement of Outdoor fan motor of capacity 5.5 Ton, suitable for ductable AC (as per sample ) complete all as specified and as directed by Engineer-in-Charge. Make - Hitachi/Danfoss/Tecumesh
M&L for replacement of blower of dia 5/8 suitable for ductable AC 5.5 ton capacity Make - Hitachi/Danfoss/Tecumesh
M&L for replacement of Al Fan blade for out door Fan motor assembly suitable for ductable AC 5.5/8.5 ton capacity Make - Hitachi/Danfoss/Tecumesh
M&L for replacement of Power contactor 32 Amps suitable for ductable AC 3 phase 415 Volt Cat Part no - 3TF34 00 - 0A.Make-Siemens
M&L for repair of VRV out door unit Make - DAIKIN ,cleaning the dust particals , tightened all loose connection, servicing all connected components finding out the leakage & the pressure test of the condenser of cooling coil of VRV type AC of capacity 18 HP,22HP & 32 HP and the same for repair the leakage point by brazing/ soldering including gas charging R-22/R-407C/R-410, and testing the AC to the entire satisfaction of Engineer-in-Charge
M&L for WATER JET servicing of VRV (complete indoor and outdoor unit by using service bag cover & cooling coil rinse solution for cleaning of coils),cassette type AC of 2.5/3.0/4.0/5.0 HP capacity taking out the indoor top cover outdoor top cover from existing location, cleaning of cooling coil , condenser coil, and other components using clean water greasing of fan, motor, blower etc without damage any part and reinstall at the same location all as directed by the Engineer-in-Chargeb
S&F in replacement of PCB control card for VRV Indoor unit cassette type AC all as specified and directed by Engineer-in-Charge.
M&L for repair of cassette type AC, PCB control card by finding out the fault and changing of diod, transformers, IC, display , connecting cord what ever required on ground and testing the AC after the replacement of components all as specified and directed by Engineer-in-Charge.
M &L for WATER JET servicing of package type AC 's cap 7.5/5.5/30 TR complete indoor and out door unit from existing location for servicing inner and outer filter complete with T&P and other accessories as directed.
M&L for WATER JET servicing of tower AC cap 4TR by taking out the same from existing location , cleaning all dust particals of cooling coil with cooling coil rinse solution and other components by the help of blower, motor , blower etc without damage any part and reinstall at the same location all as directed by the Engineer-in-Charge.
M&L for replacement of 63mm dia gun metal branch pipe and noggle conforming to IS 903 complete complete all as specified and directed.
M&L for replacement of 63mm dia 15 m hose pipe confirming to IS -636 complete with male and female coupling conforming to IS 903 complete all as specified and directed.
M &L for replacement of electrial rubber mat sheet size 2mx1m all as per directed by engg-in charge.
Mahesh Dave
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .