Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.1 LAccepted-Finance | ₹9.1 L | L1 | Accepted-Finance First Lowest |
| 2 | L2₹9.6 LAccepted-Finance KACHEETTI PUTHEN VEEDU PALIYODE KUNNATHUKAL ANAVOOR P O TRIVANDRUM 695124 | THIRUVANANTHAPURAM | THIRUVANANTHAPURAM | KERALA | 695124 | ₹9.6 L | L2 | Accepted-Finance Second lowest |
Tender Value
₹8.3 L
EMD Value
₹20,900
Closing Date
4 Jul 2026, 5:00 pmClosed
Executive Engineer,TDB Trivandrum
Office of the Executive Engineer TDB Nanthancode Trivandrum
Thiruvallam Devaswom in Trivandrum Group-Repairs and maintenance to the rooms at Bhajanamadom-reg (RETENDER)
2026_TDB_855984_2
EET/eT-11/2026-27
Open Tender
Civil Works - Others
Percentage
60 days
Thiruvallam Devaswom
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,971
₹20,900
7 Jul 2026
1 Jul 2026
6 Jul 2026
1 Jul 2026
4 Jul 2026
1 Jul 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | 1.Repair and maintenance to windows:
Taking out doors, windows and clerestory window shutters (steel or wood ) including stacking within 50 metres lead:Of area 3 sq. metres and below | - | Each | 151.6 | - |
| 1.02 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately): For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) | - | Kg | 597.71 | - |
| 1.03 | For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) | - | Kg | 723.98 | - |
| 1.04 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) | 1 | m2 | 1,307.23 | ₹1,305.92 |
| 2.01 | 2.Roof waterproofing:
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. | - | m2 | 57.76 | - |
| 2.02 | 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) | - | m2 | 377.98 | - |
| 2.03 | 9 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete | - | m2 | 351.43 | - |
| 2.04 | Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. | - | Bag | 77.58 | - |
| 2.05 | Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources). | - | m3 | 13,740.86 | - |
| 2.06 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more | - | kg | 114.92 | - |
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.13 MB
NIT_for_site.pdf
Tender Documents • 0.18 MB
BOQ_1450733.xls
BOQ • 0.32 MB
priliminaryagrementcorrected.pdf
Tender Documents • 0.02 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].