Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.4 LAccepted-AOC 61 ABHAY GARH SCHEME AIR FORCE JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L1 | Accepted-AOC LOWEST REASONABLE BID | |
| 2 | L2₹46.4 L+₹2.0 L (4.43%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹46.8 L+₹2.4 L (5.42%)Rejected-Finance NAYA BASS MAHAMANDIR JODHPUR RAJASTHAN 342006 | JODHPUR | JODHPUR | RAJASTHAN | 342006 | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹50.6 L+₹6.2 L (14.0%)Rejected-Finance 10 ABHAY GARH SCHEME CENTRAL SCHOOL AIR FORCE JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L4 | Rejected-Finance NOT LOWEST | |
| 5 | Rejected-Technical 0 NEAR SHIV MANDIR KALYANIPURA KRIPAL NAGAR AJMER RAJASTHAN 305001 | AJMER | RAJASTHAN | 305001 | - | Rejected-Technical Not Eligible bidder as No in WLR |
Tender Value
₹53 L
EMD Value
₹1.0 L
Closing Date
7 Apr 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE ARMY JODHPUR
CWE ARMY MULTAN LINES ARMY AREA JODHPUR
SPL REPAIR FOR RE ROUNTING OF HT 33 KV FEEDER FOR SHIKARGARH TAKE OVER POINT AT ARMY AREA UNDER GE ARMY UTILITY JODHPUR
2022_MES_511669_1
82122/74/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
JODHPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE ARMY UTILITY
₹1.0 L
24 May 2022
3 Mar 2022
14 Apr 2022
3 Mar 2022
7 Apr 2022
24 Mar 2022
60 days
Amount
M&L for XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with multistranded aluminium conductor, 33000 volts Earthed, grade cross sectional area 120 sq. mm, 3 core conforming to IS 7098 (Part-II) 2011 with upto date amendments complete all as specified and as directed.
Excavation in trenches manually not exceeding 1.5 m wide and not exceeding 1.5 mtr in depth for laying of cables, erection of poles, struts/stays, leveling of yard etc not exceeding 10 M² on plan and not exceeding 1.5 mtr in depth and getting out in soft/loose soil.
Excavation in trenches not exceeding 1.5 m wide and exceeding 1.5 m in depth upto 3.0 m for erection of poles, struts/stays, leveling of yard etc not exceeding 10 M² on plan and getting out in soft/loose soil.
Material and labour for sand cushioning to underground cable screened un-washed river sand including watering and consolidation complete all as specified and as directed.
Supplying and laying reinforced precast concrete cable cover, class EHV, type 1 with peak, size 450mm x 230mm x 50mm complete laid over the cable perpendicular to the cable for protection complete all as specified and as directed.
Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25 cm in soil.
Removing of excavated soil not exc. 50 M from starting points all as directed by EIC.
Material and labour for Cement concrete (1:3:6) type C -2 using 40 mm graded stone aggregate for foundation of pole /struts/stay assembly etc complete all as directed by EIC.
Material and labour Cement concrete (1:3:6) type C -1 using 20 mm graded stone aggregate for pedestal of poles/copping including necessary frame work ,fair finishing to exposed surfaces using extra cement complete form, all as directed by EIC.
Material and labour for prestressed cement concrete poles 11 M long of size 152 mm x 152 mm at top and 152 mm x 260 mm at bottom class-9, conforming to relavent latest IS including refixing of connecting items complete all as specified and directed by Engr-in-Charge on site. Note : - (i) PCC Work, excavation and earthwork will be measured and paid separately under relevant item. (ii) Refixing of cross arms (Channels/angles) and insulators will be measured and paid seperately under respective item of schedule. (iii) Necessary Zebra painting to be carried out on the bottom of pole upto 1.5 Mtr and Pole numbering as directed and cost is deemed to be included in quoted rate.
Material and labour for steel structure, cross arms, bracing supports, clamps, back plates of any type, section incl. nuts, bolts, washers, welding, fabrication/bending cold or hot in any size and shape required at site complete applying of two coats of aluminum paints over a coat of red oxide primer incl dismantling complete all as directed by Engr-in-charge.
Material and labour of unserviceable end jointing kit, outdoor type heat shinkable, 120 sq. mm 3 core suitable for 33KV 3 Core, XLPE electric cable complete all as specified and directed.
Supply & Fix Pin type, porcelain , vitreous, white , green & brown insulator including one galvanised iron long steel spindle, two galvanised iron washer and one galvanised iron nut, working pressure 33000 Volts and of size 290 mm dia x 290 mm height, ISI marked, for 10 KN max failing load complete all as specified and as directed.
Supply, fixing & stringing of ACSR conductor on poles with jumpring and binding with aluminium conductors and in yards with and incl aluminum connectors of required shape and suitable for conductor size all as directed by Engr-in-Charge.
Supply and fixing of disc type porcelain vitreous, white brown or green 145mm height and 255mm dia ball and socket type three disk assembly for tension with tension clamp for conductor working pressure 33000 volt grade, conform to IS-13134, for 7.5 KN max failing load complete all as specifed and as directed.
Supply and fix GI pipe, 'light grade' 100mm dia, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed.
Earthing complete with galvanized steel earth plate electrodes 600mmx600mmx6 mm thick buried directly in ground earth (earth pit not less 2.25 m deep below ground level) with top edge of the plate not less then 1.5 mtr below normal ground level connected to galvanised iron earthing strip 32mm x6mm thick by means of bolt nuts check nuts and washers of galvanized iron or steel all as specified & shown in electrical plate No.3 of MES SSR part-I 2009 connected to earth test point as specified and testing on completion including provision of 40 mm dia light grade pipe up to 7.5 mtr length as protection & watering pipe shall be 20 mm bore medium grade including all excavation & earth work in any type of strata incl PCC pit (1:3:6) type C-1 with RCC cover including charcoal , salt, funnel, all as directed at site. Note : Rate included for dismantling of old earth pit and removal from site.
All as per item no. 17.00 here-in- above item,but using galvanised iron wire 4mm dia as earthing lead.
Supply and fix earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4 mm dia galvanised iron or steel wire complete all as specified and as directed.
Supply and fix HT 33 KV out door type gang operated air-break switch suitable for horizontal or vertical mounting fixed type complete with 9 polymer/porcelain insulators of rating upto 200 Amps complete all as specified and as directed.
Material and labour of old unserviceable LA station class heavy duty, gap less confirming to IS 3070 having having system voltage 33 KV highest system voltage 36 KV, system fault level 25 KA, LA rated voltage 42 KV, maximum continuous operationg voltage 36 KV rms, nominal discharge current 10 KA, rated frequency 50Hz complete with all fittings suitable for 33 KV, 3 phase, earth distribution system complete all as specified. Note : Connecting earthing lead of LA shall be passed through Non metallic rigid PVC conduit and cost for the same deemed to be included in rate quoted by the contactor.
M&L for Auguring/ Driling /Boring of holes under road, pavement, hard standing by trenchless technology by mannual /machine, including fixing of HDPE pipe of 150 mm dia complete all as specified and directd by EIC.
M&L for anti-climbing device, spikes type fabricated out of M.S. bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified and as directed.
Re-routing of XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 33000 volts grade, of size 3 core 120 sqmm to185 sq mm including required earth work, sand cushioning and protection cover etc. complete all as specified and as directed.
M&L for cable path indicator made of 10 cm thick stone slab of size 60 cm x 30 cm duly marked and embadded in PCC foundation as directed by EIC.
M&L for danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size for HT, 25x20cm size complete all as specified and as directed.
S.G.ENGINEERING COMPANY
Anil Builders
RISING ELECTRICALS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .