Loading…
Loading…
Tender Value
₹82.8 L
EMD Value
₹1.7 L
Closing Date
12 Oct 2026, 3:00 pm
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
GENERAL
15 conditions · 4 needing a document upload
(As per advance correction slip No.1 of GCC April 2022) The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB of GCC-April-2022 along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
Annexure V :- As per Clause 6.1 Part-1 of GCC- The tenderer shall submit a copy of certificate (Enclosed as Annexure-V) stating that all their statements/documents submitted alongwith bid are true and factual. Non submission of above certificate by the bidder shall result in summarily rejection of his/their bid.
The minimum Eligibility Criteria: for costing more than 50 lakhs :- Applicable. 10. Eligibility Criteria: 10.1 Technical Eligibility Criteria: (a) The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i) Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii) One similar work costing not less than the amount equal to 60% of advertised value of the tender. (b)(1) In case of tenders for composite works (e.g. works involving more than one distinct component, such as Civil Engineering works, S&T works, Electrical works, OHE works etc. and in the case of major bridges - substructure, superstructure etc.), tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i) Three similar works each costing not less than the amount equal to 30% of advertised value of each component of tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of each component of tender, or (iii) One similar work each costing not less than the amount equal to 60% of advertised value of each component of tender. Note for b (1): Separate completed works of minimum required values shall also be considered for fulfillment of technical eligibility criteria for different components. (b)(2)In such cases, what constitutes a component in a composite work shall be clearly pre-defined with estimated tender cost of it, as part of the tender documents without any ambiguity. (b) (3) To evaluate the technical eligibility of tenderer, only components of work as stipulated in tender documents for evaluation of technical eligibility, shall be considered. The scope of work covered in other remaining components shall be either executed by tenderer himself if he has work experience as mentioned in clause 7 of the Standard General Conditions of Contractor through subcontractor fulfilling the requirements as per clause 7 of the Standard General Conditions of Contract or jointly i.e., partly himself and remaining through subcontractor, with prior approval of Chief Engineer in writing. However, if required in tender documents by way of Special Conditions, a formal agreement duly notarised, legally enforceable in the court of law, shall be executed by the main contractor with the subcontractor for the component(s) of work proposed to be executed by the subcontractor(s), and shall be submitted along with the offer for considering subletting of that scope of work towards fulfilment of technical eligibility. Such subcontractor must fulfill technical eligibility criteria as follows: The subcontractor shall have successfully completed at least one work similar to work proposed for subcontract, costing not less than 35% value of work to be subletted, in last 5 years, ending last day of month previous to the one in which tender is invited through a works contract. Note: for subletting of work costing up to Rs 50 lakh, no previous work experience of subcontractor shall be asked for by the Railway. In case after award of contract or during execution
Note for Item 10.1: Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organisation, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate.10.1Definition of similar works :The criteria for similar nature of work for said tender is given below as CEE/JBP's L.No. WCR/L/10/Similar Nature/3689, dtd.11.04.2012. similar nature of work criterion for Electrical General Service (GS) for Electrification work in Electrical department of WCR shall include works executed with Central Government, Semi Government/PSUs of Central Government and/or State Governments have been defined as under :- (A)The level of skills required in following work of electrification is almost same. (a) Electrification of service buildings. (b) Electrification of staff quarters, offices. (c) Electrification of offices. (d)Electrification of road & colony lighting. (e)Electrification of circulating area lighting. (f)Erection & commissioning of LT, HT upto 33 kV overhead mains. (g) Sub-station installations &commissioning. (h) Electrification of washing pits, Sheds & Workshops etc. (i) Any above work or combination of (a) to (h) above.
33 conditions · 3 needing a document upload
Labour Cooperative Societies shall submit only 50% of bid security for which the tenderers are required to upload Registration certificate issued by appropriate authority without which their offer will not be considered. Such firms should also declare that -" We are a Labour Cooperative Society and our Registration No. is .................... with .......................and hence required to deposit only 50% of Bid Security
Any firm recognized by Department of Industrial Policy and Promotion (DIPP) as 'Startups' shall be exempted from payment of Bid Security on submission of Registration Certificate issued by appropriate authority. For such firms it is required to upload a copy of Registration Certificate issued by appropriate authority without which their offer will not be considered. Such firms should also declare that - I/We am/are a Startup firm registered by ........................ Department of Industrial Policy and Promotion (DIPP) and my registration number is ................ valid upto ...................... (Copy enclosed) and hence exempted from submission of Bid Security.
THE OFFERS WITHOUT EARNEST MONEY EXCEPT IN CASE OF EXEMPTION CLAIMED AS PER COMMERCIAL COMPLIANCE OF NIT WILL BE SUMMARILY REJECTED.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Implementation of Labour Codes: - Contractor/Tenderer has to ensure Implementation of Labour Codes and strengthening compliance in respect of labour - reg. (Ref. - Rly. Bd. L. No. 2026/E(LL)/AT/CNR/5, dtd. 05.08.2026 and WCR/JBP's L. No. WCR/L/01/1134/Rly.Bd, dtd. 18.08.2026 (copy attached as document).
The Responsibilities of the contractor and the personnel engaged by them:- A mandatory orientation/training session of one to two days as may be needed/ required, conducted by Railway officials, for the contractor and the personnel deployed for specific work. The training should cover safety precautions, risks involved, required accuracy standards, work methodology and the sequence of activities to be followed in the field. No contractual labour without such training should be allowed to work on line.
LNR - Provision of FOB with ramp at Lunirichha to eliminate deficiency in MEA and Thuria - Provision of FOB with ramp at Thuria to eliminate deficiency in MEA and KRLS - Provision of FOB with ramp at Kurlasi to eliminate deficiency in MEA and DKRA - Provision of FOB with ramp at Dhuankheri to eliminate deficiency in MEA and Providing Power Supply through AT, Procurement of Furniture, Oil based Heaters, Mink Blankets, and Hot-Cold Water Dispensers for the Running Room of Kota Division, Crew & Guard Lobbies including Provision of Modular Furniture, Supply, Computerization (Computers, Printers, Scanners, UPS) & Other associate facilities. (Electrical G work for provision of AT supply at JLWC Running Room and Electrical G work for provision of AT supply at BXN Running Room and Electrical G work for provision of AT supply at SWM Running Room) and Interlocking of non- interlocked LC gate having TUV more than 20000 on Kota division" (LC 13 on KOTA-RTA Sec.) and Construction of S&T Building in connection with Interlocking of LC No: 08, 14, 51, 65, 68, 93 of KOTA-COR section of Kota Division.
EL-50-331-2026-27~WCR
EL-50-331-2026-27
Open
Works - General
18 Months
Kota, Rajasthan
₹0
₹1.7 L
16 Sept 2026
16 Sept 2026
28 Sept 2026
127 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 82,80,027.03 | ||
| — | 363.00 | — | — | ||
| Supply of LED tube light Box type Luminaire 20 watt complete with tube suitable for 230 V AC. | — | — | — | 1,26,919.32 | |
| — | 363.00 | — | — | ||
| Fixing, testing & commissioning of LED tube light Box type Luminaire 20 watt complete with tube suitable for 230 V AC. | — | — | — | 18,150 | |
| — | 40.00 | — | — | ||
| Supply of LED Street light fitting 30 watts suitable for 230 V AC. | — | — | — | 27,977.2 | |
| — | 40.00 | — | — | ||
| Installation, testing & commissioning of LED Street light fitting suitable for 230 V AC. | — | — | — | 12,036 | |
| — | 20.00 | — | — | ||
| Supply of LED FLOOD Light Fitting 150 watt complete suitable for 230 V AC 50 HZ. | — | — | — | 26,000 | |
| — | 20.00 | — | — | ||
| Installation, testing, commissioning of LED FLOOD Light Fitting complete suitable for 230 V AC 50 HZ. | — | — | — | 6,018 | |
| — | 60.00 | — | — | ||
| Supply & fixing of 'B' class GI pipe fitting made for 40mm dia for fixing of CFL fittings with all required accessories i.e. MS clamps, nut bolt washers etc. | — | — | — | 33,981.6 | |
| — | 220.00 | — | — | ||
| Wiring of light point in PVC rigid conduit pipe size 19/20 mm medium class minimum thickness 1.4 mm of ISI mark with 1.5 sqmm multistrand PVC insulated copper cable and 2.5 sqmm PVC insulated copper wire green coloured for earthing with connections etc. | — | — | — | 1,05,336 | |
| — | 1600.00 | — | — | ||
| Supply of material and wiring, testing and commissioning of sub main phase and neutral in PVC rigid conduit pipe size 25 mm dia. medium class mark with 4 sq.mm. PVC insulated single core multistransd copper cable with 2.5 sq.mm. PVC insulated copper wire green coloured for earthing and connection etc. Separate PVC pipe to be provided for this item. | — | — | — | 1,59,472 | |
| — | 4550.00 | — | — | ||
| Laying, testing & commissioning of ISI marked LT XLPE cable size 4 core aluminum conductor 1100 volt with connection etc. Note: Cable will be supplied by railway. | — | — | — | 1,13,977.5 | |
| — | 1260.00 | — | — | ||
| Digging of trench in pucca trench in yard /platform 50cm. deep and 35cm. wide including replaster on surface by cement oncrete after laying of cable. | — | — | — | 2,85,881.4 | |
| — | 2800.00 | — | — | ||
| Digging of trench in all type of soils/road cutting 100 cm. deep and 50cm. wide including supply and laying of "B" class bricks on both side & top of the cable and refilling the trench after laying of cable.2800 | — | — | — | 3,98,552 | |
| — | 560.00 | — | — | ||
| Supply of material of RCC hume pipe 6" dia (150mm) as per IS: 456-1978 or latest in existing trench under Railway track including jointing and all required accessories etc. | — | — | — | 2,48,550.4 | |
| — | 560.00 | — | — | ||
| Laying of RCC hume pipe 6" dia (150mm) as per IS: 456-1978 or latest in existing trench under Railway track including jointing and all required accessories etc. | — | — | — | 25,004 | |
| — | 210.00 | — | — | ||
| Supply, laying, fixing of heavy-duty ISI marked B class GI pipe of 3.65 mm wall thickness & 50 mm diameter to be laid along the wall or floor with proper galvanized clamp through the wall or underneath the floor in cement concrete. | — | — | — | 80,803.8 | |
| — | 62.00 | — | — | ||
| Supply of material & providing GI. pipe earthing arrangement by digging the pit as per DRM/KTT's Drg. No. 01913EL/R1 or latest complete in all type of soils including rocky area. Earth value will be taken by the contractor in the presence of Railway representative and written on the earth pit by the contractor. | — | — | — | 1,50,300.4 | |
| — | 16.00 | — | — | ||
| Supply of Flykill-LITE Insect killer machine approximate:26 Inch L X 4.5 Inch W X 12.5 Inch H. Two tubes 18W X 2, Aluminium Body. | — | — | — | 67,310.24 | |
| — | 16.00 | — | — | ||
| Installation, testing & Commissioning of Flykill-LITE Insect killer approximate:26 Inch L X 4.5 Inch W X 12.5 Inch H. Two tubes 18W X 2, Aluminium Body. | — | — | — | 2,400 | |
| — | 22.00 | — | — | ||
| Supply of materials of main distribution box 10 way suitable for housing MCB and ELCB with copper busbar and neutral link. Distribution box should be fixed on wooden taper plug or steel fasteners etc. with providing and fixing of 01 no. MCB DP 32 Amp. breaking capacity 6 KA and 06 Nos. MCB SP 6-32 Amp. breaking capacity 6 KA with 01 No. ELCB 40 Amp. DP, sensitivity 100 m.Amp. and connections etc. The distribution board is to be fixed on wall with the help of rag bolt /fastener or on board and connecting the same with suitable size of wire duly crimped lugs. | — | — | — | 1,00,592.14 | |
| — | 22.00 | — | — | ||
| Fixing, testing & commissioning of main distribution box 10 way suitable for housing MCB and ELCB with copper busbar and neutral link. Distribution box should be fixed on wooden taper plug or steel fasteners etc. with providing and fixing of 01 no. MCB DP 32 Amp. breaking capacity 6 KA and 06 Nos. MCB SP 6-32 Amp. breaking capacity 6 KA with 01 No. ELCB 40 Amp. DP, sensitivity 100 m.Amp. and connections etc. The distribution board is to be fixed on wall with the help of rag bolt /fastener or on board and connecting the same with suitable size of wire duly crimped lugs. | — | — | — | 11,195.36 | |
| — | 280.00 | — | — | ||
| Drilling of Horizontal bore below track/road by pushing method for laying of HDPE/DWC pipe of various size. | — | — | — | 11,38,020.8 | |
| — | 280.00 | — | — | ||
| Supply of material, providing, commissioning and laying of DWC/HDPE pipe of 160/138 mm dia cabling under road/track. As per explanatory notes. | — | — | — | 1,49,727.2 | |
| — | 24.00 | — | — | ||
| Dismantling of existing 5/9/11 meter long old rail / tubular poles / Octagonal poles and handing over/ deposited the same to railway store of concerned supervisor. | — | — | — | 15,384 | |
| — | 16.00 | — | — | ||
| Dismantling of old Wiring, L. P/F. P/fittings/boards etc & depositing to Concern Rly.Store. | — | — | — | 4,234.08 | |
| — | 160.00 | — | — | ||
| Supply, installation testing & commissioning of cable tray hot dip galvanized wiremash of size 105x400 mm including all accessories with cover. Dia of wire used should be minimum 5 mm. Completed in all respect as per detailed specification attached. | — | — | — | 7,19,201.6 | |
| — | 192.00 | — | — | ||
| Design, Survey, Proposal with Technical Elevation Drawings & 3D layout, Manufacture, Display of wall / hanging / floor / pole mounting type LED illuminated, Modular, Changeable Aluminium extruded profile signage / direction board as per attached Detailed Specification. | — | — | — | 3,30,781.44 | |
| — | 192.00 | — | — | ||
| Erection, Installation and testing of wall / hanging / floor / pole mounting type LED illuminated, Modular, Changeable Aluminium extruded profile signage / direction board as per attached Detailed Specification. | — | — | — | 28,800 | |
| — | 6.00 | — | — | ||
| Supply of LT Distribution panel outdoor type with canopy Enclosure 16 Gauge fabricated with MS angle Size 1575X1200X400 mm (HXWXD) approx. with door and locking arrangement duly painted red oxide and power coated enamel paint consisting of following items - INCOMING CIRCUIT- 01 No. MCCB 4 pole 160 Amp. 25 KA TM Release, Type: DN1-250C, 415V AC, 50 HZ. Ampere meter with selector switches -01 no., voltmeter with selector switch -01 no., indication lamp RYB 03 nos., Changeover Onload Manual 160 Amp. 04 Pole 01 no. with indicator 02 no., CT 150/5A 15VA- 03 nos., Copper busbar Main 200 Amp. rating- 01 set & Earth 200 Amp. - 01 Set, MCB 6A SP C 10KA - 04 nos.. OUTGOING CIRCUIT- TM Release 04 no. MCCB 4 pole 63 Amp. 25 KA. All MCCB in incoming and outgoing circuit will be provided with Extended Rotary Handle and Spreader Terminals - 4 Pole (Set of 8) etc. as per attached detailed specification. | — | — | — | 6,53,645.1 | |
| — | 6.00 | — | — | ||
| Installation, fabrication, testing & commissioning of LT Distribution panel outdoor type with canopy Enclosure 16 Gauge fabricated with MS angle Size 1575X1200X400 mm (HXWXD) approx. with door and locking arrangement duly painted red oxide and power coated enamel paint consisting of following items -INCOMING CIRCUIT- 01 No. MCCB 4 pole 160 Amp. 25 KA TM Release, Type: DN1-250C, 415V AC, 50 HZ. Ampere meter with selector switches -01 no., voltmeter with selector switch -01 no., indication lamp RYB 03 nos., Changeover Onload Manual 160 Amp. 04 Pole 01 no. with indicator 02 no., CT 150/5A 15VA- 03 nos., Copper busbar Main 200 Amp. rating- 01 set & Earth 200 Amp. - 01 Set, MCB 6A SP C 10KA - 04 nos. OUTGOING CIRCUIT- TM Release 04 no. MCCB 4 pole 63 Amp. 25 KA. All MCCB in incoming and outgoing circuit will be provided with Extended Rotary Handle and Spreader Terminals - 4 Pole (Set of 8) etc. as per attached detailed specification. | — | — | — | 56,844 | |
| — | 330.00 | — | — | ||
| Digging of the trench and refilling after laying of pipe under track at the depth of 1 meter from the formation level etc. | — | — | — | 52,107 | |
| — | 1.00 | — | — | ||
| Supply, Installation, testing & commissioning of Single phase to Three phase Static Converter for connection with AT supply having following specifications: 1. Capacity: 100 KW, 2. Input: 230 V AC (190-290 V) single phase,3. Output: 415 V, 3 phase 4 wire (R, Y, B & N) (380-440 V),4. Load: Mixed 1 phase & 3 phase i.e. light, ceiling fan, 3 phase induction load of lift, escalator, water pump etc with pf 0.8.5. Protection: Overload, Short Circuit, Lightening, Over Voltage, Under Voltage, High Temperature, Single Phasing. 6. MIS: Must have on line monitoring facility through web, through GSM SIM (mobile network) of important data including protection data at para no.5. 7. Enclosure: Indoor type (to be provided in covered area) and as per detailed specification attached. | — | — | — | 15,17,643.37 | |
| — | 2.00 | — | — | ||
| Supply, Installation, testing & commissioning of Static Hot Standby Dual Input (2 Input) 3 Phase (3P+N+G) & Single output 3 Phase (3P+N+G) as per attached detailed specification. | — | — | — | 3,70,390.44 | |
| — | 49.00 | — | — | ||
| Supply of BEE 5 star rated energy efficient BLDC ceiling fan, sweep size: 1200mm, complete with wiring connection etc. as per detailed specification attached. | — | — | — | 1,32,147.12 | |
| — | 49.00 | — | — | ||
| Erection and fixing of BEE 5 star rated energy efficient BLDC ceiling fan, sweep size: 1200mm, complete with wiring connection etc. as per detailed specification attached. | — | — | — | 9,800 | |
| — | 7.00 | — | — | ||
| Supply of wall mounted bracket fan sweep 400 mm suitable for 230 volts , 50 hz moving type with regulator and control switch on & off with accessories. | — | — | — | 12,014.03 | |
| — | 7.00 | — | — | ||
| Fixing of wall mounted bracket fan sweep 400 mm suitable for 230 volts, 50 hz moving type with regulator and control switch on & off with accessories. | — | — | — | 700 | |
| — | 21.00 | — | — | ||
| Supply of exhaust fan sweep size 300 mm suitable for 230-volt AC 50 Hz complete with accessories. | — | — | — | 24,268.23 | |
| — | 21.00 | — | — | ||
| Fixing, testing & commissioning of exhaust fan sweep size 300 mm suitable for 230- volt AC 50 Hz complete with accessories. | — | — | — | 2,025.24 | |
| — | 21.00 | — | — | ||
| Supply of materials of main distribution box 4+2 way suitable for housing MCB and ELCB with neutral link. Distribution box should be fixed on wooden taper plug or steel fasteners etc. with supply and fixing of 01 no. MCB SPN 16 Amp. breaking capacity 10 KA and 02 Nos. MCB SP 6-32 Amp. breaking capacity 10 KA with 01 No. ELCB 25 Amp. DP, sensitivity 30 m. Amp. and connections etc. The distribution board is to be fixed on wall with the help of rag bolt /fastener or on board and connecting the same with suitable size of wire duly crimped lugs. | — | — | — | 81,869.76 | |
| — | 21.00 | — | — | ||
| Fixing, testing and commissioning of main distribution box 4+2 way suitable for housing MCB and ELCB with neutral link. Distribution box should be fixed on wooden taper plug or steel fasteners etc. with supply and fixing of 01 no. MCB SPN 16 Amp. breaking capacity 10 KA and 02 Nos. MCB SP 6-32 Amp. breaking capacity 10 KA with 01 No. ELCB 25 Amp. DP, sensitivity 30 m.Amp. and connections etc. The distribution board is to be fixed on wall with the help of rag bolt /fastener or on board and connecting the same with suitable size of wire duly crimped lugs. | — | — | — | 9,106.65 | |
| — | 273.00 | — | — | ||
| Supply, installation, testing & commissioning of concealed wiring of light/Fan/Bell points in PVC rigid conduit pipe size 25mm dia medium class minimum thickness approx. 1.6mm to 1.8mm of ISI mark with 1.5 sq.mm. multistrand PVC insulated copper conductor cable confirming to IS:694-1990 or latest with one holder/ceiling rose on junction box with round plate with 2.5 sq.mm. PVC insulated copper wire green coloured for earthing alongwith connection etc. including stone wall cutting, replaster, painting and other civil work | — | — | — | 1,05,929.46 | |
| — | 3500.00 | — | — | ||
| Supply of material for concealed wiring of sub main phase & neutral in PVC rigid conduit pipe size 25mm dia medium class minimum thickness approx. 1.6mm to 1.8mm of ISI mark with 4 sq.mm. PVC insulated single core multistrand copper cable with 2.5 sq.mm. PVC insulated copper wire green coloured for earthing & connection etc. Separate PVC pipe to be provided for this item. including stone wall cutting, replaster, painting and other civil work | — | — | — | 4,41,210 | |
| — | 3500.00 | — | — | ||
| Erection, testing & commissioning of concealed wiring of sub main phase & neutral in PVC rigid conduit pipe size 25mm dia medium class minimum thickness approx. 1.6mm to 1.8mm of ISI mark with 4 sq.mm. PVC insulated single core multistrand copper cable with 2.5 sq.mm. PVC insulated copper wire green coloured for earthing & connection etc. Separate PVC pipe to be provided for this item. including stone wall cutting, replaster, painting and other civil work | — | — | — | 3,35,825 | |
| — | 28.00 | — | — | ||
| Supply of flush metal box of 2-Module with connection used for concealed modular flush metal box wiring. | — | — | — | 1,965.6 | |
| — | 28.00 | — | — | ||
| Erection & fixing of flush metal box of 2-Module with connection used for concealed modular flush metal box wiring. | — | — | — | 320.04 | |
| — | 28.00 | — | — | ||
| Supply of plate Inner & Outer 2-Module used for concealed modular wiring. | — | — | — | 4,097.52 | |
| — | 28.00 | — | — | ||
| Erection & fixing of plate Inner & Outer 2-Module used for concealed modular wiring. | — | — | — | 506.24 | |
| — | 14.00 | — | — | ||
| Supply of flush metal box of 4-Module with connection used for concealed modular flush metal box wiring. | — | — | — | 1,815.52 | |
| — | 14.00 | — | — | ||
| Erection & fixing of flush metal box of 4-Module with connection used for concealed modular flush metal box wiring. | — | — | — | 295.54 | |
| — | 14.00 | — | — | ||
| Supply of plate Inner & Outer 4-Module used for concealed modular wiring. | — | — | — | 3,807.58 | |
| — | 14.00 | — | — | ||
| Erection & fixing of plate Inner & Outer 4-Module used for concealed modular wiring. | — | — | — | 470.54 | |
| — | 21.00 | — | — | ||
| Supply of flush metal box of 8-Module with connection used for concealed modular flush metal box wiring. | — | — | — | 3,704.82 | |
| — | 21.00 | — | — | ||
| Erection & fixing of flush metal box of 8-Module with connection used for concealed modular flush metal box wiring. | — | — | — | 602.91 | |
| — | 21.00 | — | — | ||
| Supply of material of plate Inner & Outer 8-Module used for concealed modular wiring. | — | — | — | 6,305.46 | |
| — | 21.00 | — | — | ||
| Erection & fixing of plate Inner & Outer 8-Module used for concealed modular wiring. | — | — | — | 735 | |
| — | 294.00 | — | — | ||
| Supply of S.P. switch 6 / 10 Amp. one way (1-Module). | — | — | — | 36,117.9 | |
| — | 294.00 | — | — | ||
| Erection & fixing of S.P. switch 6 / 10 Amp. one way (1-Module). | — | — | — | 4,921.56 | |
| — | 70.00 | — | — | ||
| Supply of blank plates (1-Module) used for concealed modular wiring. | — | — | — | 2,165.1 | |
| — | 70.00 | — | — | ||
| Erection & fixing of blank plates (1-Module) used for concealed modular wiring. | — | — | — | 239.4 | |
| — | 21.00 | — | — | ||
| Supply of 6 Amp. 5-pin socket (2-Module). | — | — | — | 3,935.4 | |
| — | 21.00 | — | — | ||
| Erection & fixing of 6 Amp. 5-pin socket (2-Module). | — | — | — | 486.36 | |
| — | 21.00 | — | — | ||
| Supply of fan regulator 5-step (2-Module) used for concealed modular wiring. | — | — | — | 14,632.59 | |
| — | 21.00 | — | — | ||
| Erection & fixing of fan regulator 5-step (2-Module) used for concealed modular wiring. | — | — | — | 770.07 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Clarification-Annexure-VofGCCwithTenders..pdf
ATTACHMENT
GCC_April-2022_Final.pdf
ATTACHMENT
AnnexureLC-Inclusionofletterofcredit.pdf
ATTACHMENT
GCCAdv.CorrectionslipofGCC1-10_1.pdf
ATTACHMENT
GCCAdvanceCorrectionSlipNo11.pdf
ATTACHMENT
SpecificationofLEDLuminare-2026-1.pdf
ATTACHMENT
3DSignageBoardSpecification.pdf
ATTACHMENT
Annexure-E.pdf
ATTACHMENT
MakeinIndiapolicylatestamendment.pdf
ATTACHMENT
DempoymentofEngineers.pdf
ATTACHMENT
GCCAdvanceCorrectionSlipNo.12.pdf
ATTACHMENT
ImplementationofLabourCodesinrespectofcontractlabour_compressed.pdf
ATTACHMENT
TenderSch.EL50-3312026-27-2_1.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .