Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.3 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹7.4 L+₹5,432.73 (0.74%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹7.4 L+₹5,867.39 (0.80%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹7.4 L+₹7,623.28 (1.04%)Rejected-AOC SHAZIYA MANZIL PUTHALAM AREACODE 673639 | MALAPPURAM | KERALA | 673639 | L4 | Rejected-AOC L4 |
Tender Value
₹8.8 L
EMD Value
₹13,258
Closing Date
23 Sept 2021, 5:00 pmClosed
Assistant Executive Engineer
Assistant Executive Engineer,PWD Buildings Sub Division, Cherani, Karuvambram (PO) Manjeri
GENERAL-Special repairs to police family quarters, Manjeri- Leak proofing and other Repair works Buildings NO.33-1499,1500,1501,1502- Work-General Civil work
2021_PWD_439693_1
TR/BL/2021/635/1
Open Tender
Civil Works - Buildings
Item Rate
180 days
Manjeri
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,950
Yes
₹13,258
Yes
9 Nov 2021
15 Sept 2021
28 Sept 2021
15 Sept 2021
23 Sept 2021
15 Sept 2021
Amount
DETAILED ESTIMATE
15.31:Dismantling tiled roofing with battens, boarding etc. complete including stacking of serviceable material and disposal of unserviceable material within 50 metres lead.
15.12.1:Dismantling doors, windows and clerestory windows (steel or wood ) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead:Of area 3 sq. metres and below
15.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
50.9.13.3:Supplying and fixing Vengai wood wrought and put up for roof members including cost and conveyance of materials etc. complete.
od61784/2020_2021/BL:Re roofing MP tiles including all charges (based on specification code 12.48)
od61785/2020_2021/BL:Supplying and fixing340mm MP roofing tiles including all charges etc complete
12.49:Providing & laying on roof pressed clay tile ridge (Mangalore tile) of 20 mm thickness and of approved pattern on steel frame work complete (steel frame work to be paid separately ).
13.32.1:Pointing on tile brick work with cement mortar 1:3 ( 1 cement : 3 fine sand):Flush /Ruled / Struck or weathered pointing
50.9.1.1:Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood
50.9.2.1:Providing and fixing paneled and glazed shutters for doors, windows and clerestory windows, 35 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineerin - charge using Anjili/ Jack wood
50.9.4.1:Providing and fixing paneling or paneling and glazing in paneled or paneled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured) paneling for paneled or paneled and glazed shutters 25 mm to 40 mm thick using good quality Anjili/ Jack wood
od61786/2020_2021/BL:Supplying and providing best quality PVC Door having thick 30mm or nearest size with frame including all cost of furniture fitting, labour charges for making and fixing in position etc complete.
od61787/2020_2021/BL:providing ceiling with TKT board 9mm thick with 7.5x7.5mm size Aluminium square tube for fraames and squre tube for rrames and supports L section on sides T section for fixing the boardtying with GI wire etc. including all charges (details for 10.00x3.00m =30 m2 ) a) 25.4mx25.4m(1.59mm thick size equal angle length wise 2x 10.00m = 20.00 width 2x3.00m = 6.00m Total = 26.00m add 5% wastage = 1.30 Total = 27.30m @ 0.211kg/m = 5.760 kg b) 25.40mmx25.40mm square tube 1mm thich length wise (1m c/c) 4x10.00m =40.00m cross (1.50m c/c)3x11x0.972 =32.07m strut 4x6x.50 =12.00m Total = 88.07m add 5% for wasteage =4.20m Total 88.27m @0.264kg/m =23.30kg total weight29.06 kg
18.54.1:Providing and fixing PTMT bib cock of approved quality and colour.15 mm nominal bore, 86 mm long, weighing not less than 88 gms
15.28.2:Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking the material within 50 metres lead of :Asbestos Sheet
50.10.2:Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
12.50:Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
OD20678/2021-2022:Cleaning septic tank after removing the RCC Covering slab drawing out the night soil from tank with one extra lift and conveyed with one extra lead and filling the night soil in the pit newly constructed and re-filling earth for conveying the night soil and cleaning the tank etc. complete as per the directions of the engineer in charge
50.18.7.2.1:Providing and fixing PVC pipes, fittings including fixing the pipe with claps at 1.00 metre spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 20 mm dia 12Kgf/cm2 - Internal work - Exposed on wall
50.18.9.9.1:Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2
50.18.7.6.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 6 Kgf/cm2 - Internal work- Exposed on wall
15.7.4:Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar
50.6.7.2:Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc.
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
5.1.3:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
10.25.2:Item Shifted to Sub head 14 as item 14.73 Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
17.13.2:Providing and fixing white vitreous china water closet squatting pan ( Indian type):Orissa pattern W.C. pan of size 580x440 mm
26.40:Providing and fixing hard drawn steel wire fabric of size 75 x25 mm mesh or other suitable size wire mesh to be fixed & firmly anchored to the concrete surface by means of "L" shaped mild steel shear key welded with existing reinforcement including the cost of materials, labour, tool & plants as approved by Engineer-in-charge.
11.40:Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer) of Ist quality conforming to IS: 15622 of approved make in all colours, shades, except white, Ivory, Grey Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigments etc., complete.
14.54.1:Painting with synthetic enamel paint of approved brand and manufacture of required colour to an give even shade:One or more coats on old work
13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
14.53.1:Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade:One or more coats on old work
od61789/2020_2021/BL:Engaging man mazdoor for cleaning premises
od61790/2020_2021/BL:engaging carpenter for repairing furniture
11.20.4:Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand).Ordinary cement without any pigment
SUDHEER K
K. MOOSA
V. LIYAKATHALI
Bidder Name
K. MOOSA
SUDHEER K
V. LIYAKATHALI
SHIHABUDDEEN.PK
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_625145.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .