Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹47.3 LAccepted-AOC THOTTAPPALLY HOUSE EMILY KALPETTA P O KERALA 673121 | WAYANAD | KERALA | 673121 | 1 | Accepted-AOC After negotiation with the first lowest bidder, the total accepted PAC is Rs. 4729672/-. Hence accepted | |
| 2 | Rejected-Technical | - | Rejected-Technical The second lowest bidder, the total amount is above the estimated amount. Hence Rejected |
Tender Value
₹48.6 L
EMD Value
₹50,000
Closing Date
10 Feb 2021, 3:00 pmClosed
Executive Engineer
KSHB-Kozhikode Division, Chakkorathukulam
Renovation of OP units in NMCH Block GENERAL MEDICINE ANDPSYCHIATRY
2021_KSHB_410560_1
EE/KKD/4/2020-2021-R
Open Tender
Civil Works - Buildings
Item Rate
180 days
NMCH Block, Govt. Medical College
As per NIT Condition
3 documents required · 3 mandatory
₹2,500
Yes
₹50,000
Yes
KSHB-Kozhikode Division, Chakkorathukulam
25 May 2022
1 Feb 2021
11 Feb 2021
2 Feb 2021
10 Feb 2021
2 Feb 2021
2 Feb 2021 - 10 Feb 2021
5 Feb 2021
Amount
GENERAL MEDICINE
Dismantling aluminium / Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in 50 metres lead as directed by Engineer - in-Charge
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm
Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar
Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.
Dismantling the existing damaged wash basin as directed by the deparmental officers at site
Taking out doors, windows and clerestory window shutters (steel or wood ) including stacking within 50 metres lead:Of area 3 sq. metes and below
Providing & Fixing of Armstrong Mineral Fibre Acoustical Suspended Ceiling System with Dune (Bevelled Tegular) Edge Tiles With Armstrong 15mmExposed GRID. <br>The tiles should have Humidity Resistance (RH) of 99%, NRC 0.5, Light Reflectance 85%, Thermal Conductivity k = 0.052 - 0.057 w/mK, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 16mm , suitable for Green Building application, with Recycled content of 32%. <br>The tile shall be laid on Armstrong Silhouette profile grid system with 15mm white flanges incorporating a 6mm central reveal in white/black colour and with a web height of 38mm and a load carrying capacity of minimum 14 Kgs/M2 & minimum pull out strength of 100 Kgs.. Silhouette, Main Runners & Cross Tees to have mitred ends & “birdsmouth” notches to provide mitred cruciform junctions. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system of Armstrong make. . <br>The Tile & Grid system used together should carry a 30 year warranty. <br>INSTALLATION:To comprise main runner spaced at 1200mm centres securely fixed to the structural soffit using Armstrong suspension system (specifications below) at 1200mm maximum centre. The First/Last Armstrong suspension system at the end of each main runner should not be greater than 450mm from the adjacent wall. <br>Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm centre to form 1200 x 600 mm module. Cut cross tees longer than 600mm require independent support. 600 x 600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200 mm cross tees.<br>Perimeter trim to be Armstrong wall angles of size 3000x19x19mm, secured to walls at 450 mm maximum centres.<br>Installation to be carried out by Armstrong Trained Installation team & Installation should be carried out as per Armstrong recommended procedure.<br>ARMSTRONG SUSPENSION SYSTEM accessories manufactured and supplied by Armstrong World Industries consisting of M6 Anchor Fasteners with Vertical Hangers made of Galvanised steel of size 26 x 26 x 25 x 1.2mm with a Galvanised Thickness of 80gsm, A pre Straightened Hanger wire of dia – 2.5 mm of 1.8 m length., thickness of 80gsm and a tensile strength of 344-413 MPa, along with Adjustable hook clips
Providing & fixing suspended ceiling in flat, curved or other shapes as indicated in the drawing including fixing of G I. perimeter channels of size 0.55mm thick having one flange of 20mm and another flange of 30mm and web of 27mm along with perimeter of ceiling, screw fixed to be onto brick wall / partition with the help of nylon sleeves and screws, at 610mm centers. Then suspending G I. intermediate channels of size 45mm, 0.9mm thick with two flanges of 15mm each from the soffit at 1220mm centers with ceiling angle of width of 25mm X 10mm X 0.55mm thick fixed to soffit with Gig. cleat and steel expansion fasteners. Ceiling section of 0.55mm thickness having knurled web of<br>51.5mm and two flanges of 26mm each with lips of 10.5mm are then fixed to the intermediate channel with the help of connecting clip and indirection perpendicular to the intermediate channel at 457mm centers. all sections are gyproc ultranew<br>12.5 mm tapered edge Standard Gypsum board (confirming to IS: 2095- 1982 & 2542- 1981)gyproc or equivelant is then screw fixed to ceiling section with 25mm drywall screws at 230mm centers. Screw fixing is done mechanically either with screw driver or drilling machine with suitable attachment. Finally the standard gypsum boards are to be jointed and finished so as to have a flush look which includes filling and finishing the tapered and square edges of the board with jointing compound, Joint paper tape. Thecolour, shade and texture should be approved by Architect. Rate shall be include with all material shifting with all lead and lifts, masking for fixtures<br>& frames, cutting light & AC cut outs & temporary stand & scaffolding where ever required as per instruction by architect.
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
11.41.2, 11.42, 11.43: Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, including grouting the joints with white cement and matching pigments etc., complete.- Size of Tile 600x600 mm Ceramic/ Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3 mm thickness.<br>
Providing floor finish with anti-skid ceramic tiles best quality (exact shade to be got approved by the architect) of size 300mmx300mm or nearest size for the toilets rooms , passage etc..laying in cement mortar 1:4 12mm thick and closing the joints with white cement slurry mixed with approved matching pigment including cost and conveyance of all materials to site, labour charges for laying and finishing tothe required level and slope etc. complete for all floors. <br>
Providing and fixing I st quality ceramic glazed wall tiles of size 45x30 cms conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.75 ltr/10 sqm of approved brand and manufacture
Mirror polishing on marble work/ granite work/stone work where ever required to give high gloss finish complete.
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 25 mm pipe 12 kgf/cm2
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 6 kgf/cm2
Supplying and fitting Automatic door closer for aluminium door including labour charges for fitting conveyance etc complete<br> 0
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Surgeon Type wash basin of size 660x460 mm with single 15 mm C P. brass pillar taps with elbow operated levers ISI marked
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
Extra for providing opening or required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal boreer coating 50 micron)
Supplying and fixing 15 mm CP angle cock
Providing and fixing PTMT Soap Dish Holder having length of 138 mm, breadth 102 mm, height of 75 mm with concealed fittings arrangements, weighing not less than 106 gms.
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm. weighing not less than 170 gms2
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)
For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness
Providing and fixing Aluminium grill work includind cost and conveyance of labour charges and cost of channel fixing etc complete.<br>
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides
Brick work with common burnt clay F.P.S (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand)s
12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more
Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
Providing and laying gang saw cut 18 mm thick, mirror polished pre moulded and pre polished machine cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring in road side plazas and similar locations, laid over 20 mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement mixed with matching pigment, epoxy touch ups etc. complete as per direction of Engineer-in-charge.Area less than 0.50 sqm.
Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite work
Supplying and fitting LESSO EITI /ALUPLAST/KOEMMERING OR similar type upvc fixed partition wall using steel frames of size60x40mm,upvc frame of size 60x57 ,1.5mm thick steel reinforcement inside upvc frame ,5mm plain / frosted glass or upvc panel which ever is proposed by engineer in charge including ,making charges ,conveyace charges,installation cgharges etc complete as directed by the engineer incharge<br
Supplying and fitting LESSO EITI /ALUPLAST /KOEMMERLINGOR similar type upvc door using frames of size112x60mm,steel frame work 60x50mm,2mm thick steel reinforcement inside upvc frame ,5mm plain / frosted glass or upvc panel which ever is proposed by engineer in charge including hinges,friction stays,screws,silicon sealant,single point lock/dead lock (godrej),handle,pedal,automatic door closer(godrej) ,making charges ,conveyace charges,installation cgharges etc complete as directed by the engineer incharge NMCH<br>
Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved
Charges for loading ,transporting ,unloading to the dismantled serviceable materials such as anodised aluminium doors and partition walls having particle board and glass etc to the PWD store shed which is about 500mts apart as directed by the engineer in charge
PSYCHIATRY
Dismantling aluminium / Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in 50 metres lead as directed by Engineer - in-Charge
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm
Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar
Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
Providing & Fixing of Armstrong Mineral Fibre Acoustical Suspended Ceiling System with Dune (Bevelled Tegular) Edge Tiles With Armstrong 15mmExposed GRID. <br>The tiles should have Humidity Resistance (RH) of 99%, NRC 0.5, Light Reflectance 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 16mm , suitable for Green Building application, with Recycled content of 32%. <br>The tile shall be laid on Armstrong Silhouette profile grid system with 15mm white flanges incorporating a 6mm central reveal in white/black colour and with a web height of 38mm and a load carrying capacity of minimum 14 Kgs/M2 & minimum pull out strength of 100 Kgs.. Silhouette, Main Runners & Cross Tees to have mitred ends & “birdsmouth” notches to provide mitred cruciform junctions. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system of Armstrong make. . <br>The Tile & Grid system used together should carry a 30 year warranty. <br>INSTALLATION:To comprise main runner spaced at 1200mm centres securely fixed to the structural soffit using Armstrong suspension system (specifications below) at 1200mm maximum centre. The First/Last Armstrong suspension system at the end of each main runner should not be greater than 450mm from the adjacent wall. <br>Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm centre to form 1200 x 600 mm module. Cut cross tees longer than 600mm require independent support. 600 x 600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200 mm cross tees.<br>Perimeter trim to be Armstrong wall angles of size 3000x19x19mm, secured to walls at 450 mm maximum centres.<br>Installation to be carried out by Armstrong Trained Installation team & Installation should be carried out as per Armstrong recommended procedure.<br>ARMSTRONG SUSPENSION SYSTEM accessories manufactured and supplied by Armstrong World Industries consisting of M6 Anchor Fasteners with Vertical Hangers made of Galvanised steel of size 26 x 26 x 25 x 1.2mm with a Galvanised Thickness of 80gsm, A pre Straightened Hanger wire of dia – 2.5 mm of 1.8 m length., thickness of 80gsm and a tensile strength of 344-413 MPa, along with Adjustable hook clips
Providing & fixing suspended ceiling in flat, curved or other shapes as indicated in the drawing including fixing of G I. perimeter channels of size 0.55mm thick having one flange of 20mm and another flange of 30mm and web of 27mm along with perimeter of ceiling, screw fixed to be onto brick wall / partition withthe help of nylon sleeves and screws, at 610mm centers. Then suspending G I. intermediate channels of size 45mm, 0.9mm thick with two flanges of 15mm each from the soffit at 1220mm centers with ceiling angle of width of 25mm X 10mm X 0.55mm thick fixed to soffit with Gig. cleat and steel expansion fasteners. Ceiling section of 0.55mm thickness having knurled web of<br>51.5mm and two flanges of 26mm each with lips of 10.5mm are then fixed to the intermediate channel with the help of connecting clip and indirection perpendicular to the intermediate channel at 457mm centers. all sections are gyproc ultranew<br>12.5 mm tapered edge Standard Gypsum board (confirming to IS: 2095- 1982 & 2542- 1981)gyproc or equivelant is then screw fixed to ceiling section with 25mm drywall screws at 230mm centers. Screw fixing is done mechanically either with screw driver or drilling machine with suitable attachment. Finally the standard gypsum boards are to be jointed and finished so as to have a flush look which includes filling and finishing the tapered and square edges of the board with jointing compound, Joint paper tape. Thecolour, shade and texture should be approved by Architect. Rate shall be include with all material shifting with all lead and lifts, masking for fixtures<br>& frames, cutting light & AC cut outs & temporary stand & scaffolding where ever required as per instruction by architect.
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
11.41.2, 11.42, 11.43: Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, including grouting the joints with white cement and matching pigments etc., complete.- Size of Tile 600x600 mm Ceramic/ Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3 mm thickness.<br>
Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Twoor more coats on new work
Providing & Fixing of Armstrong Mineral Fibre Acoustical SFinishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.75 ltr/10 sqm of approved brand and manufacture
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 25 mm pipe 12 kgf/cm2
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the walletc. 50 mm pipe 6 kgf/cm2
Dismantling the existing damaged wash basin as directed by the deparmental officers at site
Supplying and fitting Automatic door closer for aluminium door including labour charges for fitting conveyance etc complete<br>
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Surgeon Type wash basin of size 660x460 mm with single 15 mm C P. brass pillar taps with elbow operated levers ISI marked
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of thefloor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
Extra for providing opening or required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore
Supplying and fixing 15 mm CP angle cock
Providing and fixing PTMT Soap Dish Holder having length of 138 mm, breadth 102 mm, height of 75 mm with concealed fittings arrangements, weighing not less than 106 gms.
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm. weighing not less than 170 gms
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium(minimum thickness of powder coating 50 micron)
For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)r
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness
Providing and laying gang saw cut 18 mm thick, mirror polished pre moulded and pre polished machine cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring in road side plazas and similar locations, laid over 20 mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement mixed with matching pigment, epoxy touch ups etc. complete as per direction of Engineer-in-charge.Area less than 0.50 sqm
Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite work
Supplying and fitting LESSO EITI /ALUPLAST/KOEMMERLING OR similar type upvc fixed partition wall using steel frames of size60x40mm,upvc frame of size 60x57 ,1.5mm thick steel reinforcement inside upvc frame ,5mm plain / frosted glass or upvc panel which ever is proposed by engineer in charge including ,making charges ,conveyace charges,installation cgharges etc complete as directed by the engineer incharge<br>
Supplying and fitting LESSO EITI /ALUPLAST /KOEMMERLING OR similar type upvc door using frames of size112x60mm,steel frame work 60x50mm,2mm thick steel reinforcement inside upvc frame ,5mm plain / frosted glass or upvc panel which ever is proposed by engineer in charge including hinges,friction stays,screws,silicon sealant,single point lock/dead lock (godrej),handle,pedal,automatic door closer(godrej) ,making charges ,conveyace charges,installation cgharges etc complete as directed by the engineer incharge NMCH<br>
Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved
Charges for loading ,transporting ,unloading to the dismantled serviceable materials such as anodised aluminium doors and partition walls having particle board and glass etc to the PWD store shed which is about 500mts apart as directed by the engineer in charge
MODIFICATION OF EXISTING STORE ROOM AS CONSULTING ROOM OF PHYCHIATRY
Providing & Fixing of Armstrong Mineral Fibre Acoustical Suspended Ceiling System with Dune (Bevelled Tegular) Edge Tiles With Armstrong 15mmExposed GRID. <br>The tiles should have Humidity Resistance (RH) of 99%, NRC 0.5, Light Reflectance 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 16mm , suitable for Green Building application, with Recycled content of 32%. <br>The tile shall be laid on Armstrong Silhouette profile grid system with 15mm white flanges incorporating a 6mm central reveal in white/black colour and with a web height of 38mm and a load carrying capacity of minimum 14 Kgs/M2 & minimum pull out strength of 100 Kgs.. Silhouette, Main Runners & Cross Tees to have mitred ends & “birdsmouth” notches to provide mitred cruciform junctions. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system of Armstrong make. . <br>The Tile & Grid system used together should carry a 30 year warranty. <br>INSTALLATION:To comprise main runner spaced at 1200mm centres securely fixed to the structural soffit using Armstrong suspension system (specifications below) at 1200mm maximum centre. The First/Last Armstrong suspension system at the end of each main runner should not be greater than 450mm from the adjacent wall. <br>Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm centre to form 1200 x 600 mm module. Cut cross tees longer than 600mm require independent support. 600 x 600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200 mm cross tees.<br>Perimeter trim to be Armstrong wall angles of size 3000x19x19mm, secured to walls at 450 mm maximum centres.<br>Installation to be carried out by Armstrong Trained Installation team & Installation should be carried out as per Armstrong recommended procedure.<br>ARMSTRONG SUSPENSION SYSTEM accessories manufactured and supplied by Armstrong World Industries consisting of M6 Anchor Fasteners with Vertical Hangers made of Galvanised steel of size 26 x 26 x 25 x 1.2mm with a Galvanised Thickness of 80gsm, A pre Straightened Hanger wire of dia – 2.5 mm of 1.8 m length., thickness of 80gsm and a tensile strength of 344-413 MPa, along with Adjustable hook clips
Providing & fixing suspended ceiling in flat, curved or other shapes as indicated in the drawing including fixing of G I. perimeter channels of size 0.55mm thick having one flange of 20mm and another flange of 30mm and web of 27mm along with perimeter of ceiling, screw fixed to be onto brick wall / partition with the help of nylon sleeves and screws, at 610mm centers. Then suspending G I. intermediate channels of size 45mm, 0.9mm thick with two flanges of 15mm each from the soffit at 1220mm centers with ceiling angle of width of 25mm X 10mm X 0.55mm thick fixed to soffit with Gig. cleat and steel expansion fasteners. Ceiling section of 0.55mm thickness having knurled web of<br>51.5mm and two flanges of 26mm each with lips of 10.5mm are then fixed to the intermediate channel with the help of connecting clip and indirection perpendicular to the intermediate channel at 457mm centers. all sections are gyproc ultranew<br>12.5 mm tapered edge Standard Gypsum board (confirming to IS: 2095- 1982 & 2542- 1981)gyproc or equivelant is then screw fixed to ceiling section with 25mm drywall screws at 230mm centers. Screw fixing is done mechanically either with screw driver or drilling machine with suitable attachment. Finally the standard gypsum boards are to be jointed and finished so as to have a flush lookwhich includes filling and finishing the tapered and square edges of the board with jointing compound, Joint paper tape. Thecolour, shade and texture should be approved by Architect. Rate shall be include with all material shifting with all lead and lifts, masking for fixtures<br>& frames, cutting light & AC cut outs & temporary stand & scaffolding where ever required as per instruction by architect.
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
11.41.2, 11.42, 11.43: Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, including grouting the joints with white cement and matching pigments etc., complete.- Size of Tile 600x600 mm Ceramic/ Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3 mm thickness.<br>
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm
Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar
Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.
Providing floor finish with anti-skid ceramic tiles best quality (exact shade to be got approved by the architect) of size 300mmx300mm or nearest size for the toilets rooms , passage etc..laying in cement mortar 1:4 12mm thick and closing the joints with white cement slurry mixed with approved matching pigment including cost and conveyance of all materials to site, labour charges for laying and finishing to the required level and slope etc. complete for all floors. <br>
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new wo
Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.75 ltr/10 sqm of approved brand and manufacture
Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
Supplying and fitting LESSO EITI /ALUPLAST KOEMMERLING OR similar type upvc fixed partition wall using steel frames of size60x40mm,upvc frame of size 60x57 ,1.5mm thick steel reinforcement inside upvc frame ,5mm plain / frosted glass or upvc panel which ever is proposed by engineer in charge including ,making charges ,conveyace charges,installation cgharges etc complete as directed by the engineer incharge<br>
Supplying and fitting LESSO EITI /ALUPLAST/ KOEMMERLING OR similar type upvc door using frames of size112x60mm,steel frame work 60x50mm,2mm thick steel reinforcement inside upvc frame ,5mm plain / frosted glass or upvc panel which ever is proposed by engineer in charge including hinges,friction stays,screws,silicon sealant,single point lock/dead lock (godrej),handle,pedal,automatic door closer(godrej) ,making charges ,conveyace charges,installation cgharges etc complete as directed by the engineer incharge NMCH<br>
M SURESH
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_583404.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .