RequiredExperience with Government
RequiredAnnual Turnover
RequiredCertificate (Requested in ATC)
RequiredOEM Authorization Certificate
RequiredOEM Annual Turnover Bid to RA enabled No Note: 1. OEM Turn Over Criteria: The minimum average annual financial turnover of the OEM of the offered product during the last three years
Requiredending on 31st March of the previous financial year
Requiredshould be as indicated in the bid document. Documentary evidence in the form of certified Audited Balance Sheets of relevant periods or a certificate from the Chartered Accountant/Cost Accountant indicating the turnover details for the relevant period shall be uploaded with the bid. In case the date of constitution/incorporation of the OEM is less than 3 year old
Requiredthe average turnover in respect of the completed financial years after the date of constitution shall be taken into account for this criteria. Fixed Clean Agent Gas Based Cylinderless Fire Suppression System ( 64 pieces ) Technical Specifications 1/6 * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) GENERIC System Operation The heat-sensitive polymer/Plastic tubing stores extinguishing clean agent agent in the tube itself eliminating the need for external cylinder .It should also have a inbuilt pressure gauge (maintaining low pressure) which shows the pressure in the tube. In case of fire
Requiredwhen temperature inside panel/engine compartment reaches between 80-120ºC
Requiredthe heat-sensitive tubing bursts at the point it is in contact with the flame to form a miniature nozzle. The extinguishing agent is sprayed out of the tube through the miniature nozzle
Requiredflooding the localized area and instantly extinguishing the flame. The heat-sensitive polymer/Plastic tubing stores extinguishing clean agent agent in the tube itself eliminating the need for external cylinder .It should also have a inbuilt pressure gauge (maintaining low pressure) which shows the pressure in the tube. In case of fire
Requiredwhen temperature inside panel/engine compartment reaches between 80-120ºC
Requiredthe heat-sensitive tubing bursts at the point it is in contact with the flame to form a miniature nozzle. The extinguishing agent is sprayed out of the tube through the miniature nozzle
Requiredflooding the localized area and instantly extinguishing the flame. CYLINDER-LESS AUTOMATIC FIRE DETECTION & SUPPRESSION SYSTEM or Fixed Clean Agent Gas based Fire Suppression System suitable for maximum 2 metre cube volume Designed to fight fires that occur in the enclosed space of electric panels/closed cabinets/Racks/Vehicle Engine Compartments. The system's split second detection and activation ensures that the fires are killed in the nascent stage inside the most vulnerable spaces . Designed to fight fires that occur in the enclosed space of electric panels/closed cabinets/Racks/Vehicle Engine Compartments. The system's split second detection and activation ensures that the fires are killed in the nascent stage inside the most vulnerable spaces . Suitability of system For Vehicle Engine compartment Fire Protection: HFC236fa For Vehicle Engine compartment Fire Protection: HFC236fa Volume of protected enclosed Area for which Cylinderless Tubing System is 0.78-1.16 m³ 0.78-1.16 m³ 2/6 required (cubic meter) Type of Clean agent with zero ODP(ozone depleting potential) as per NFPA 2001 to be used for fire suppression HFC236fa For Vehicle Engine compartment Fire Protection * Clean Agent listing UL * CONSTRUCTIONAL Tubes Containing the clean agent design Compliant to European Union Directive 2014/68/EU for Pressure Equipment * Electrical non conductive Clean Agent Type Yes * Clean agent Capacity in each Tube 1 1.0 Length of Heat Sensing Tube (HST) made of special modified polymide (PA) in (meter) approved by ILAC UL LISTED 4.19 4.19 Internal Diameter of Heat Sensing Tube 15 mm ±5% * Out side diameter of heat sensing tube 18 mm±5% * Additional Pressure Switch No * Additional Audio Signalling Unit No * The scope of work shall cover supply and commissioning of Cylinder less Clean Agent Gas based automatic fire detection fire suppression system based on polyamide tube Yes * The work is required to be executed for (consignee address) on electrical panels or vehicles at site Yes * The fire extinguishing agent shall be a clean Yes * 3/6 agent which shall be self contained in tube along with inbuilt pressure gauge for easy identification in case of leakage PERFORMANCE Ozone Depleting Potential Zero * HST Tube type Single layer * Burst Pressure at 20 ⁰C for Clean Agent Filled Tube 20 * Minimum and maximum operation temperature minimum -40°C
Requiredmaximum + 80°C minimum -40°C
Requiredmaximum + 80°C System operating pressure 15 bar maximum * CERTIFICATION Complete system testing and certification from ILAC/NABL as per European Union Directive 2014/68/EU for Pressure Equipment covering all declared parameters Yes * Test report of the Heat sensing tube Yes * Marking of OEM Supplier Name & year of production on the tube Yes * System operation and maintenance manual to be submitted along with the supplies Yes * Design lifespan period (Min 5 years) 5 * Test Report No and Date - * Name and Address of the Lab - * Test Reports to be furnished to the buyer on demand Yes * Warranty of the complete system 1 1.0 * Specifications highlighted in bold are the Golden Parameters. * Bidders may note that In respect of non-golden Parameters
Requiredthe specifications 'Values' chosen by Buyer will generally be preferred over 'Bid requirement ( allowed Values) by the Buyer. 4/6 Additional Specification Documents