Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.0 LAccepted-AOC 43 SABJI MAHAL ORDERLY BAZAR PO BARRACKPORE DIST 24 PARGANAS N KOLKATA 700120 | KOLKATA | 24 PARGANAS N | WEST BENGAL | 700120 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹41.6 L+₹4.3 L (11.6%)Rejected-Finance GOALAPARA MONIRAMPUR PO BARRACKPORE DIST 24 PARGANAS NORTH KOLKATA 700 120 WB | KOLKATA | 24 PARGANAS NORTH | WEST BENGAL | 700120 | L2 | Rejected-Finance Rejected being higher than L1 | |
| 3 | Rejected-Technical 20 NO TIKIA MAHAL ORDERLY BAZAR BARRACKPORE DIST 24 PARGANAS NORTH STATE WEST BENGAL PIN 700 120 | BARRACKPORE | 24 PARGANAS NORTH | WEST BENGAL | 700120 | - | Rejected-Technical Rejected due to not enlisted in appropriate category | |
| 4 | Rejected-Technical | - | Rejected-Technical Rejected due to not enlisted in appropriate category | |
| 5 | Rejected-Technical | - | Rejected-Technical Rejected due to not enlisted in appropriate category |
| Sl No | Description | Qty | Unit | JADAV CONSTRUCTION L2 | S.C. TRADING COMPANY L1 |
|---|---|---|---|---|---|
| 1.00 | Carryout monthly inspection and checking of Fire alarm detection and extinguisher system by the OEM or their authorised dealer as approved by GE at 6 Wg and Jaffarpore for the following parameters :-
(a) All Fire & smoke detectors are working satisfactorily and within the parameters as governed by IS 2189 :2008 & ISO 12239 : 2010.
(b) All heat sensitive detectors are working satisfactory as per IS 2173: 2010.
(c) The sense and detection timing of fire /Smoke detector are within the parameter and response time to trigger the extinguisher is as per the IS 2189: 2008
(d) To check the system pressure as per OEM manual including serviceability and action response time of manifold system as per OEM existing set requirement.
(e) To check all the system valves are working with the threshold parameters.
(f) To check as release system and calibration in case of requirement as per exisiting system & OEM standards and as per IS 15493(2004).
(g) To check all the addressable components including siren/hooter, monitor module Panel are working satisfactorily.
(h) Servicing and cleaning of fire detector panels, detectors, modules, with the periodicity as decided by OEM or their certified agency.
Contd... | 9 | Per Month | 36,000 ₹3,24,000 | 30,725 ₹2,76,525 Lowest |
| 1.10(j) Material and labour charges for replacement of minor parts such as gasket, gland packing, polish paper, distilled water for battery, battery terminals, cotton cloths and all type of washers of valves are included in the quoted rates. (k) During of currency of contract all the items of complete Fire system shall be in good and operating condition. If any abnormality is found the same shall is found the same shall be reported to Engr-in-charge immediately and be rectified on priority. Breakdown Maintenance:- (a) All breakdown shall be attended and rectified in 24 hrs. If skilled technician is not able to rectifiy the breakdown then contractor shall contact the OEM/OEM certified agency for rectification of breakdown. No extra payment shall made on this account for any breakdwon service during maintenance period. (b) Breakdown maintenance calls will be attended within a maximum of 24 hrs of the receipt of the complaintd and be rectified in 48 hrs. If breakdown is not rectified in 48 hrs, penality of Rs. 1000/day shall be imposed. (c) The contractor will also maintain service reports for all visits & breakdown visits & copy of the same will be submitted every month, if any (d) The cost of the above are deemed to be included in the quoted rates. (e) The bidder are requested to visit the work site before quoting their tender. | |||||
| 2.00 | Servicing, overhauling and testing of empty Gas Cylinder of capacity 120 Litres and Supply, testing after filling of gas FK-5-1-12 Fire Protection fluid compound of carbon, fluorine and oxygen (CF3CF2C(O)CF(CF3)2) of 42 Bar pressure system not less than 100 kgs as per OEM certification complete with checking pressure gauge, head valve, cylinder Hydrotest including two coat of flame retardant paint on cylinder in red colour over one coat of red oxide primer including preperation of surfaces complete all as specified and directed.
Note: -
(i) Cost of gas shall be included in the quoted rates.
(ii) Transportation included in the quoted rates.
(iii) Test certificate shall be submitted by the contractor for both i.e. empty and filled gas cylinder with weight of each cylinder as directed by Engr-in charge. | 2 | Each Job | 2,38,000 ₹4,76,000 | 2,30,000 ₹4,60,000 Lowest |
| 3.00 | Servicing, overhauling and testing of empty Gas Cylinder of capacity 110 Litres and testing after filling of gas FK-5-1-12 Fire Protection fluid compound of carbon, fluorine and oxygen (CF3CF2C(O)CF(CF3)2) of 42 Bar pressure system not less than 80 kgs as per OEM certification complete with checking pressure gauge, Head valve, cylinder Hydrotest including two coat of flame retardant paint on cylinder in red colour over one coat of red oxide primer including preperation of surfaces complete all as specified and directed.
Note: -
(i) Cost of gas shall be included in the quoted rates.
(ii) Transportation included in the quoted rates.
(iii) Test certificate shall be submitted by the contractor for both i.e. empty and filled gas cylinder with weight of each cylinder as directed by Engr-in charge. | 2 | Each Job | 2,16,000 ₹4,32,000 | 1,96,000 ₹3,92,000 Lowest |
| 4.00 | Servicing, overhauling and testing of empty Gas Cylinder of capacity 80 Ltrs and testing after filling of gas FK-5-1-12 Fire Protection fluid compound of carbon, fluorine and oxygen (CF3CF2C(O)CF(CF3)2) of 42 Bar pressure system not less than 60 kgs as per OEM certification complete with checking pressure gauge, Head valve, cylinder Hydrotest including two coat of flame retardant paint on cylinder in red colour over one coat of red oxide primer including preperation of surfaces complete all as specified and directed.
Note: -
(i) Cost of gas shall be included in the quoted rates.
(ii) Transportation included in the quoted rates.
(iii) Test certificate shall be submitted by the contractor for both i.e. empty and filled gas cylinder with weight of each cylinder as directed by Engr-in charge. | 3 | Each Job | 1,74,000 ₹5,22,000 | 1,60,250 ₹4,80,750 Lowest |
| 5.00 | Supply, Installation and testing of new 120 Litres Capacity Seamless cylinder including filled with fire protection fluid not less than 100 kgs as per OEM certification and valve assembly and pressure gauge with a safety burst disc and meet a safety capacity for 42Bar pressure system UL listed & CCOE Approved Cylinder, complete duly Approval-UL/LPCB/VDS Listed complete all as specified and directed.
Make : Honeywell/Seimens/Esser | 2 | Each | 2,62,000 ₹5,24,000 | 2,45,250 ₹4,90,500 Lowest |
| 6.00 | Supply and fix Electric Control Head operated electrically from the Detection & Control System or locally with a manual lever on the control head for 42Bar pressure system duly Approval-UL/LPCB/VDS Listed complete all as specified and directed.
Make : Honeywell/Seimens/Esser. | 4 | Each | 53,000 ₹2,12,000 | 47,000 ₹1,88,000 Lowest |
| 7.00 | Supply and fix Pressure Operated Control Head which allows for pressure actuation slave cylinders and is mounted directly on top of the slave cylinders valve duly Approval-UL/LPCB/VDS Listed complete all as specified and directed.
Make : Honeywell/Seimens/Esser | 2 | Each | 12,400 ₹24,800 | 9,307 ₹18,614 Lowest |
| 8.00 | Supply and fix Master Cylinder Adapter Kit used to actuate the Slave Cylinder for 42 Bar system duly Approval-UL/LPCB/VDS Listed complete all as specified and directed.
Make : Honeywell/Seimens/Esser | 2 | Each | 7,441 ₹14,882 | 5,375 ₹10,750 Lowest |
| 9.00 | Supply and fix discharge hose, 1-1/2” (use with 34, 80, 120 & 140 Ltr. Cylinders) UL listed complete all as specified and directed. | 2 | Each | 31,500 ₹63,000 | 23,000 ₹46,000 Lowest |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
25 Oct 2025, 6:00 pmClosed
GE AF Barrackpore
GE AF Barrackpore Post Barrackpore Dist 24 Parganas North Kolkata 700120
REPAIR / MAINT OF FIRE ALARM AND FIRE EXTINGUISHER SYSTEM, REFILLING OF EXTINGUISHER GASES AND ITS CONNECTED WORKS AT VARIOUS LOCATIONS OF 6WG AF UNDER GE (AF) BARRACKPORE
2025_MES_733828_1
8638/BKP/AF OF 2025-26
Open Tender
Miscellaneous Works
Item Rate
270 days
GE AF Barrackpore
Class-D,
Category-c(vi)
2 documents required · 2 mandatory
₹500
GE AF Barrackpore
₹70,000
Yes
22 Nov 2025
4 Oct 2025
27 Oct 2025
4 Oct 2025
25 Oct 2025
18 Oct 2025
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.39 MB
Tenderdoc8638.pdf
Tender Documents • 1.09 MB
BOQ_821636.xls
BOQ • 1.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .