Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.4 LAccepted-AOC | L1 | Accepted-AOC AOC accepted. | |
| 2 | L2₹39.5 L+₹14,834.40 (0.38%)Rejected-AOC NO 26 SRI GANESH 7TH CROSS BDS NAGAR DIBBUR RAMAIAH LAYOUT K NARAYANPURA MAIN ROAD BANGALORE 560 077 | BENGALURU URBAN | KARNATAKA | 560077 | L2 | Rejected-AOC AOC rejected. | |
| 3 | L3₹49.3 L+₹9.9 L (25.0%)Rejected-AOC | L3 | Rejected-AOC AOC rejected. | |
| 4 | L4₹49.6 L+₹10.2 L (25.8%)Rejected-AOC | L4 | Rejected-AOC AOC rejected. |
Tender Value
Refer Docs
EMD Value
₹93,000
Closing Date
25 Nov 2021, 6:00 pmClosed
GE DEHRADUN
GE (MES) Dehradun, Garhi Cantt, Mall Road, Tele - 01352750580
Special Repair to roof, window, doors and sunkun floor in Bldg No P-136 MT line, Bldg no P-26 incl WC/ bath and approach path area from Akash Ganga bldg at young road, Bldg no P-58 APS Birpur and Provn of DG Set for Area Account Office under GE Deh
2021_MES_484095_1
8360/A/E8
Open Tender
Civil Works
Item Rate
180 days
DEHRADUN
Class D cat a (i) and b (i)
8 documents required · 8 mandatory
₹500
GE DEHRADUN
₹93,000
13 Dec 2021
27 Oct 2021
27 Nov 2021
27 Oct 2021
25 Nov 2021
11 Nov 2021
Amount
M&L for excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep in hard/ dense soil for foundation, LT cables etc. or for shafts, wells, cesspits, manholes, pierholes, cable etc n.exc 10 Sqm on plan and getting out complete all as specified and directed by Engr-in-Charge.
Returning, filling in soil including spreading, leveling watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed by Engr-in-Charge.
Removing excavated surplus soil/material not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed by Engr-in-Charge.
Demolition of cement concrete unreinforced in ground floors and pavings n. exc. 15 cm thickness(below or above ground level) complete all as specified and directed by Engr-in-Charge.
Dismantling asbestos cement sheet (Corrugated, semi corrugated etc) in roof covering including ridge, vally gutters complete all as specified and directed by Engr-in-Charge. .
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof/wall coverings complete all as specified and directed by Engr-in-Charge.
Dismantling structural steel work including doors, gates any description complete all as specified and directed by Engr-in-Charge.
M&L for pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 MPA as in roof covering/cladding to wall fixed with self tapping screws, complete all as specified and directed by Engr-in-Charge.
S&F pre-painted Galvalume aluminum zinc coating GI based plain steel 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall fixed with self tapping screws complete all as specified and directed by Engr-in-Charge.
Dismantling wall and ceiling boards (Fibre, pulps, insulation etc) or insulation boards / Slabs/ Blankets of any thickness incl cover fillets if any complete all as specified and directed by Engr-in-Charge.
Providing & fixing tiled false ceiling Perforated Accostic GYP board tile Ivory painted (High Pressure Steam cured) of 12mm thickness (as per IS : 14862) of size 595x595mm and any one of the design (Cascade or electra) in true horizental level, suspended on inter locking metal grid of hot dipped galvanised steel section (Galvanised @120 grms, both side inclusive and black painted groove on all T webs) consisting of main T runner with suitably spaced joints to get required length and 15x32mm made from 0.30mm thick sheet spaced at 1200mm c/c and croos 'T' of size 15x32mm made of 0.30mm sheet 1200mm long spaced between main "T" at 600 mm c/c to form a grid of 1200x600mm and secondary cross "T" of length 600mm and size 15x32 mm made of 0.30mm thick sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x22x0.40mm and laying false ceiling tiles in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI soffit cleats fixed to existing RCC lintel with dash fasteners, GI adjustable rods of 3mm dia with galvanised Butterfly level clips or 3mm dia GI wire spaced at 1200mm c/c along main 'T', bottom exposed width of 15mm, all 'T'' sections shall be pre-painted with polyester paint and black painted groove at center of size 4mm depth and 4.5mm width, all complete at all heights as per direction of Engineer-in-Charge. Make-1) Everest/ Saint Gobin or equivalent as approved by GE . :2) Taking down carefully of existing accessories from wall/ ceiling i.e adaptor, CCTV camera etc adn re-fixing is included in the quoted rate by contractor.
Providing & fixing tiled false ceiling of Everest Designer tile Ivory painted (High Pressure Steam cured) of 4mm thickness (as per IS : 14862) of size 595x595mm and any one of the design (Cascade or electra) in true horizental level, suspended on inter locking metal grid of hot dipped galvanised steel section (Galvanised @120 grms, both side inclusive and black painted groove on all T webs) consisting of main T runner with suitably spaced joints to get required length and 15x32mm made from 0.30mm thick sheet spaced at 1200mm c/c and croos 'T' of size 15x32mm made of 0.30mm sheet 1200mm long spaced between main "T" at 600 mm c/c to form a grid of 1200x600mm and secondary cross "T" of length 600mm and size 15x32 mm made of 0.30mm thick sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x22x0.40mm and laying false ceiling tiles in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI soffit cleats fixed to existing RCC lintel with dash fasteners, GI adjustable rods of 3mm dia with galvanised Butterfly level clips or 3mm dia GI wire spaced at 1200mm c/c along main 'T', bottom exposed width of 15mm, all 'T'' sections shall be pre-painted with polyester paint and black painted groove at center of size 4mm depth and 4.5mm width, all complete at all heights as per direction of Engineer-in-Charge.
Dismantling timber scantlings 40 Sqcm and over in section in any position in framed/ unframed work complete all as specified and directed by Engr-in-Charge.
S&F second class hardwood as in scantling, clean sawn, timber framed and fixed in any position complete all as specified and directed by Engr-in-Charge.
S&F rolled mild steel sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates conforming to Fe-410-W (Gde-E-250) quality A complete all as specified and directed by Engr-in-Charge.
S&F mild steel Framed work such as grills, gratings , Iron Chowkhats etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work mild steel conforming toFe 290. Gde-E-165 complete all as specified and directed by Engr-in-Charge.
S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc of Fe-290 (Gde E-165) and painted one shop coat of zinc chromate primer paint including preparation of surface at contractor workshop before fabrication complete all as specified and directed. complete all as specified and directed by Engr-in-Charge.
Demolition of brick work or stone/ boulder masonry built in cement mortar including all quoins, arches, pillars etc. but excluding ashlars facing, dressed stone work & precast concrete articles complete all as specified and directed by Engr-in-Charge.
M&L for brick work with sub class 'B' bricks, straight or curved on plan exceeding 6 mtr mean radius and built in cement mortar (1:6) complete all as specified and directed (using old size bricks).
Taking down cement or cement lime plaster on walls of any description including racking out joints hacking for key, scrubbing down with water etc. and removing rubbish complete all as specified and directed by Engr-in-Charge.
M&L rendering 15mm thick on fair faces of brick work in CM 1:6 and finished surfaces even and smooth without using extra cement complete all as specified and directed by Engr-in-charge
M&L for rendering 15mm thick in cement mortar 1:4 on walls (fair / unfair finished faces of brick/concrete), finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge. (Water proofing compound where ever ordered shall be added and the same will be measured and paid separately)
Taking down existing roof treatment/cement plaster on roof including racking out joints, hacking for key and scrubbing down with water etc complete all as specified and ditected.
M&L for rendering 15 mm thick on roof surfaces including facia in cement mortar 1:4 finished surfaces even and smooth without using extrar cement complete all as specified and as directed by Engr-in-Charge.
M&L 10 mm thick ceiling plaster in CM (1:4) on fair faces of concrete surfaces finished even and smooth without using extra cement including fixig of wire mesh to receive plaster where required complete all as specified and ditected.
Supply only integral waterproofing compound complete all as specified and ditected.
M&L for 75mm cement concrete type D-2 1:4:8 (using 40mm graded aggregate) sub base to receive top layer complete all as specified and directed by Engr-in-Charge..
M&L for precast PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in coping, benching etc including necessary weathering, slightly rounded or chamfered angles and throating complete all as specified and directed by Engr-in-Charge.
Taking down chowkats or frames exc. 1.5 Sq mtr and not exc 4 Sq mtr each with shutters without taking off shutters from the frames complete all as specified and as directed by the Engineer-in-Charge
Taking down chowkats or frames Chowkhats or frames not exc. 1.5 sqm each each with shutters without taking off shutters from the frames complete all as specified and as directed by the Engineer-in-Charge
Taking down shutters of any description exc 1 sqm n.exc 2 sqm each and refixing in same opening after necesssary repair complete all as specified and directed by Engr-in-Charge.
Taking down shutter of any description n.exc 1.00 sqm each complete all as specified and directed by Engr-in-Charge.
S&F 2nd class hard wood plain, solid, straight Chowkats & frames, wrought, framed rebated on the solid, rounded or chamfered, put together withglue pinned at joints, supplied & fixed complete all as specified and directed by Engr-in-Charge.
M&L cutting holes in brick wall built in cement mortar exc half brick but n exc one brick for inserting hold fast etc and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required complete all as specified and directed by Engr-in-Charge.
Cutting holes into or through brick walls built in cement mortar and making good in CM 1:3 or cement cone 1 :2:4 Type Bl as required area exc 150 Sqcm & n.exc 400 Sqcm complete all as specified and directed by Engr-in-Charge.
S&F mild steel flat iron for hold fasts and similar articlesincluding bolts conf to Fe-290 gde E-165, complete all as specified and directed by Engr-in-Charge.
Supply and fix 35 mm thick second class hard wood plain framed paneled shutters (two panels) with lock rail and panels of 9 mm BWP commercial ply or 12 mm veneered particle board for others with commericial veneering on both faces and size of members of door shutters as per IS :1003(part I ) as specified in SSR part I section 3 clause 8.20 (a) fitted to chowkats, kiln seasoned and chemically pressure treated complete all as specified and as directed by the Engineer-in-Charge
Supply and fix 35 mm thick second class hard wood glazed and skeleton door shutters, open rebated and prepared to receive glass/gauge etc., without sash bars but divided into two panels, with bottom panel fitted 9 mm B.W.P. comercial ply or 12 mm venered particle board with commercial veneering, (half panel board & half wire mesh) wood additional stiles/rails edges of framing plain, chamfered or rounded fitted with miterd beads for receiving glass, gauge etc,size of members of door shutters as specified in SSR part I section 3 Clause 8.20(a) fitted to chowkats complete all as specified and as directed by the Engineer-in-Charge Note- wire cloth will be measured and paid separtely.
S/F Solid PVC door frame of size 50mmX47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube in opening as per specification & drawing as shown in SSR part II complete all as specified and directed by Engr-in-Charge.
S/F Factory made solid panel PVC door shutter 30 mm thick [Style] consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC "C" channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement supplying & fixing in frame at site as per specification & drawing as shown in SSR part II, complete all as specified and directed by Engr-in-Charge.
S&F factory made steel windows with side hung shutters including box type hinges with MS handles and tower bolts complete with glazing bars dovetailed or welded with one shop coat of primer complete all as specified and directed by Engr-in-Charge.
S&F factory made steel windows with side hung shutters including box type hinges with MS handles and tower bolts complete without glazing bars, as fly proof shutters with one shop coat of primer complete all as specified and directed by Engr-in-Charge.
S&F factory made steel windows or ventilators, fixed type, with glazing bars complete all as specified and directed by Engr-in-Charge.
M&L for Ist class hardwood beads,mitred, straight sectional area exe 6 and n exe 9 sqcm for fixing of wire cloth etc complete all as specified and directed by Engr-in-Charge.
S&F 300mm long MS Helical door spring welded to steel frame or fixed to wooden door frame with screws including roller and roller plate etc complete all as specified and directed by Engr-in-Charge.
S&F in repair 300mm long MS Helical door spring to steel chowkhat with same as but fixed to wooden door frame including roller and roller plate etc of approved quality complete all as specified and directed by Engr-in-Charge.
S&F 200 mm long,stainless steel barrel tower bolts of 204 gde complete all as specified and directed by Engr-in-Charge..
S&F 100 mm long,stainless steel, barrel tower bolts of 204 gde complete all as specified and directed by Engr-in-Charge.
M&L butt hinges mild steel, medium weight 100 mm size complete all as specified and directed by Engr-in-Charge.
S&F 100 mm size butt hinges, cast brass, with mild steel hinge pin, bright polished and fixed, typeB-11 , complete all as specified and directed by Engr-in-Charge.
S&F 150mm size stainless steel handles, D type, 204 gde fixed with stainless steel screws all as directed complete all as specified and directed by Engr-in-Charge.
S&F 125mm size stainless steel handles, D type, 204 gde fixed with stainless steel screws all as directed complete all as specified and directed by Engr-in-Charge.
S&F 100mm size stainless steel handles, D type, 204 gde fixed with stainless steel screws all as directed complete all as specified and directed by Engr-in-Charge.
M&L for 35 mm thick, factory made BWR flush shutters, solid core construction, with block board core and plywood face pannels commercial type on both sides including provision of suitable blocks for taking mortice locks, latches or other fittings complete all as specified and directed.
S&F factory made 100 % solid wood plastic composite (WPC) flush type shutter of 18mm thickness one side laminate consisting of panel of PVC profile of 18mm (+ 0.7mm) thick of denisity 600 kg per cum manufactured by ISO-9000 certified company using for shutter cillicia ply 18mm thick and fixed with frame. The thickness of shutter is edges painted by matching colour of PVC lining of plain/prelim coloured PVC sheet using etc complete as per manufacture specification.
Taking down existing projected type hings from the steel window carefully with disturbing frame and S&F 50 mm long mild steel box type hinge weld to steel frame and shutter with welding and making good including touch with paint and with existing surfaces including scaffolding all as directed by Engr-in-charge.
M&L plain fillets 2nd class Hard wood exc 13 & n exc 25 Sqcm Square or rectangular in section, wrought secured with nails or barbs complete all as specified and ditected.
S&F Hasp and staple 100mm safety type, stainless steel 304 grade with hinge pin including bolt to hinge plate and fixed with screws complete all as specified and ditected.
S&F floor door stopper of stainless steel double legged and tongue, 304 grade, with hard drawn steel spring, fixed in floor, overall length of cover plate 140mm complete all as specified and ditected.
S & F Continuous (Piano) hinges, mild steel, bright finished or stainless steel 304 grade, width of flaps (When open) 30 mm complete all as specified and ditected.
S&F magnet catcher for cub board with brass body and striking plate including letting in and fixed complete all as specified and directed.
S&F stainless steel sliding door bolts 204 grade,250mm long, hasp and staple type with bright bolt not less than 12mm dia with and incl a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and ditected.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames including punching or drilling out old glazing pins/spring clips complete all as specified and directed by Engr-in-Charge.
M & L sheet glass ordinary quality 4mm thick and glazing with oil putty or fixed with bead/ glazing pins in squares n.exc 0.5 sqm each pane ,all corner of glass to be fixed with silicon complete all as specified and directed by Engr-in-Charge.
M & L fiigured glass,pin head type, 4mm thick and glazing with oil putty or fixed with bead/ glazing pins in squares n.exc 0.5 sqm each pane ,all corner of glass to be fixed with silicon complete all as specified and directed by Engr-in-Charge.
S&F Stainless steel 304 grade wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples with 8% nickle complete all as specified and ditected.
S&F in repairs Stainless steel 304 grade wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples with 8% nickle complete all as specified and ditected.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engr-in-Charge.
M&L for coloured Non Skid Ceramic tiles 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.06 sqm but not exceeding 0.11 sqm , in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed 15mm thick in CM 1:6 complete all as specified and directed by Engr-in-Charge.
M&L for coloured Non Skid Ceramic joint free tiles 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm , in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed 15mm thick in CM 1:6 complete all as specified and directed by Engr-in-Charge.
M&L for coloured Glazed ceramic tiles in vertical surfaces of size 350mm x 250mm x 7mm/ 450x 350 x 7mm thick over and including 10 mm thick bedding layer in CM 1:4 , set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engr-in-Charge.
M&L for coloured Non Skid Ceramic joint free tiles 7 to 8mm thick (square/rectangular) as in skirting cut from tiles exceeding 0.11 sqm but not exceeding 0.18 sqm, set and jointed in neat cement slury and pointed in white or coloured cement to match including screed bed 10mm thick in cm 1:4 complete all as specified and directed by Engr-in-Charge.
M & L for 25 mm thick Cement concrete 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) as in floor base complete all as specified and directed by Engr-in-Charge.
M&L for sand cushioning for laying of inter locking tiles (paving blocks ) etc laid in layers, including water and consolidation complete all as directed by Engineer-in-charge.
M&L for prepolished machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm tickness , M-35 grade, over well rammed sand ,set, jointed and pointed in neat cement slurry in floors with grey cement & pigments all as directed by Engineer-in-Charge.(Note- sand wiil be measured and paid seperetely under respective item of schedule)
M & L for coloured prepolished rubber moulded chequred cement concrete tile 30 cm x 30 cm x 22 to 25 mm thick set, jointed and pointed in neat cement slurry as in floor with grey cement and filling joints with colour pigment over and including 15 mm thick screed bed in cement mortar 1:6 including dismantling of old tiles complete.complete all as specified and directed.
Demolition of Stone slabs and tiles laid, bedded in any mortar of any description or thickness in floors, aprons etc complete all as specified and directed by Engr-in-Charge.
M&L for 20 to 22mm thick Machine cut kota stone slab 550 x 550mm in one colour as in flooring over and including 15 mm thick CM 1:6 screed base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and directed by Engr-in-Charge.
M&L for 20 to 22mm thick Kota stone tiles (Pre-mirror polished), in riser of steps, skirting, etc, set and jointed in neat cement slurry and pointed in coloured cement to match tiles including rounding the edges of kota stone over and including 10mm thick backing coat in cement mortar (1:4), surfaces finished even and rough to receive tiles, , complete all as specified and directed by Engr-in-Charge.
M&L 18 to 20 mm thick machine cut polished Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including grinding and moulding of exposed edges of granite complete all as specified and directed by Engr-in-Charge.
M&L for PCC (1:3:6) type C-2 (using 40mm graded stone aggreate), 75 mm thick as in plinth protection, finishing the surface even & fair without using extra cement the plinth protection shall be laid in alternate bays n exe 2 Sqm, 10mm joints shall be provided, joints shall be filled with bitumen mastic, bitumen mastic comprise of 1 Part of Hot bitumen 85/25 grade and 3 parts of sand all by weight complete all as specified and directed by Engr-in-Charge.
Taking up or down steel tubing and connections with all fittings for 15 mm bore GI tubing complete all as specified and directed by Engr-in-Charge.
Taking up or down steel tubing and connections with all fittings for 20 mm bore GI tubing complete all as specified and directed by Engr-in-Charge.
Refixing of old steel tubing and connections in new or old position with all fittings to floor, wall or ceiling as directed, for 15mm bore GI tubing complete all as specified and directed by Engr-in-Charge.
Refixing of old steel tubing and connections in new or old position with all fittings to floor, wall or ceiling as directed, for 20mm bore GI tubing complete all as specified and directed by Engr-in-Charge.
M&L cutting chases, pinning in, making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves lintels etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good cutting not exc 10cm girth complete all as specified and directed by Engr-in-Charge.
S&F medium grade galvanised steel tubing with all fittings fixed to wall or laid in floors of 15 mm bore complete all as specified and directed by Engr-in-Charge.
S&F medium grade galvanised steel tubing with all fittings fixed to wall or laid in floors of 20 mm bore complete all as specified and directed by Engr-in-Charge.
S & F in repair 15 mm bore bib taps, chromium plated cast copper alloy long body, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed by Engr-in-Charge.
S & F in repair 15 mm bore bib taps, chromium plated cast copper alloy short body, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed by Engr-in-Charge.
S&F in repairs CP angle cock fancy type, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engr-in-Charge.
S&F stop valves 15 mm bore fancy type, chromium plated, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed by Engr-in-Charge.
S&F in repair CP brass shower rose 100mm dia suitable for 15 mm dia pipe complete all as specified and directed by Engr-in-Charge.
S&F in repair 08 Litr Dual capacity PVC low level flushing cistern including PVC syphon and float valve with PVC long bend for out let, fixing with WC complete all as specified and directed by Engr-in-charge
S&F in repairs PVC connection 15mm size with PTMT nuts, of 450 mm long complete all as specified and directed by Engr-in-Charge.
S&F in repairs PVC waste pipe not less than 60 cm long with PVC coupler for kitchen sink , WHB , Urinal etc complete all as specified and directed by Engr-in-Charge.
S&F in repairs 20mm dia brass chromium plated tubular towel rails, D type, 60cm long between flanges, complete all as specified and directed by Engr-in-Charge.
S&F in repairs Soap dish 6 inches, fixed with chromium plated brass screws complete all as specified and directed by Engr-in-Charge.
Dismantling water tank of any description exc 250 ltr and not exc 500 ltr Capacity complete all as specified and directed by Engr-in-Charge.
S&F rotational moulded polyethylene 500 Ltrs Capacity water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position in including brass ball valve, with polythelene float three layer external and internal white and fly nut complete screwed down for iron pipe of 15 mm dia complete all as specified and directed by Engr-in-Charge.
Supply and fixed in repair vitreous china wash hand basin including brackets, white of size 550 x 400 mm incl cutting cutting for and pinning in ends of brackets Waste fittings of brass, chromium plated with long screwed shanks and fly-nuts, flange end bedded in cement and other and fixed complete all as specified and directed by Engr-in-Charge.
S&F of pillar tap 15mm dia cast copper allow with capstan head chromium plated screwed down high pressure, with or without lettered hot or cold with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as specified and directed by Engr-in-Charge.
S&F in repair viterous china squatting pan (orissa pattern) long pan size 580x440mm white with integral footrest with cast iron spun 600 mm long 'P' trap (SI 3989 1984), set in cement concrete type B-1 (1:2:4) complete (excluding flushing cistern and flush pipe) complete all as specified and directed by Engr-in-charge.
S&F in repair ball valve high pressure of PTMT with epoxy coated alum rod & high density plastic ball screwed for 20 mm bore iron pipe and fixed ( minimum weight 20mm -210 gms) complete all as specified and directed by Engr-in-Charge.
M&L for preparation of new wooden surfaces over 10 cm width or girth and applying two coat of synthetic enamel paint of any tint , over a coat of pink primer, complete all as specified and directed by Engr-in-Charge.
M&L for preparation of new untreated steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge.
M&L for preparation of old decorated surfaces of wall and applying one coat of white wash on wall complete all as specified and directed. White washing shall be carried out using DDL
M&L for newly plastered surface of walls including cornices and applying two coats of distemper oil emulsion over and including of 2-3 mm thick wall care putty to finish wall surface even & smooth over a primer coat complete all as specified and directed by Engr-in-Charge.
M&L for complete removal of existing treatment of walls including cornices and applying two coats of distemper oil emulsion over and including of 2-3 mm thick wall care putty to finish wall surface even & smooth over a primer coat complete all as specified and directed by Engr-in-Charge.
M&L for preparation of new plastered surfaces of walls and applying two coat of cement base paint on external wall surfaces over a primer coat complete all as specified and directed by Engr-in-Charge.
M&L for complete removal of existing treatment from wall upto plaster surface by electric sand paper grinder, washing, rubbing down and stopping of existing treatment including cleaning of mortar drops, smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots etc and preparation of plastered surfaces finally rubbed and smooth with sand paper and appling two coat of cement base paint on external wall surfaces complete all as specified and directed by Engr-in-Charge.
M&L for three coats of white wash on newly plastered surfaces of walls including preparation of surfaces complete all as specified and ditected.
M&L for three coats of white wash on newly plastered surfaces of ceiling including preparation of surfaces complete all as specified and ditected.
Complete removal of existing treatment of wall by mechanised method and preparation of surface of wall and applying 2-3 mm thick of interior grade acrylic water proof wall care putty and applying one coat of exterior water based primer by using Airless spray techonology with max working pressure of 3300 PPSI and capable of operating single spray gun with a max material hose length of 30 mtr, the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressue and paint usage and certified by jpaint manufacturer and as mentioned in PS and accessories for applying distemper, should be able to spray in hard to reach areas and penetration of distemper, on the surface to achieve excllent application using limited manpower complete all as specified and directed. Note : - Sanding of old decorated surface to be done by mechanical sander with 1500 - 2700 rpm, with internal dust extraction system for clean environment certified by paint manufacturer.complete all as specified and directed by Engr-in-Charge.
M&L for applying two coats of oil bound distemper on new/ already prepared plastered surfaces of walls using Airless spray technology with max working pressure of 3300 PPSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surface to achieve excellent application using limited manpower complete all as specified and directed by Engr-in-Charge. Note : - Sanding of surface to be done by mechanical sander with 1500 - 2700 rpm, with internal dust extraction system for clean environment certified by paint manufacturer.
M&L for applying two coat of exterior weather proof 100% anti fungal acrylic smooth emulsion with silicon additives that offer anti alge high performance exterior wall finish with 6 years of performance warranty by manufacturer applied by using Airless spray technology with max working pressure of 3300 PPSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacture with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper, should be able to spray in hard to reach areas and penetration of distemper on the surface to achieve excellent application using limited manpower complete all as specified and directed by Engr-in-Charge.
M&L for preparing old surface of wood and wood based materials, of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed by Engr-in-Charge.
M&L for applying one coat of synthetic enamel paint on old steel surface of any description over 10 cm width or girth including preparation of surface complete all as specified and directed by Engr-in-Charge.
M&L for complete removal of existing treatment from wall upto plaster surface by electric sand paper grinder, washing, rubbing down and stopping of existing treatment including cleaning of mortar drops, smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots etc and preparation of plastered surfaces finally rubbed and smooth with sand paper complete all as directed by Engr-in-charge.
M&L preparation of old decorated surfaces of ceiling (Plastered) by brooming down or sand paper, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots complete all as directed by Engr-in-charge.
M&L one coat of white wash on already prepared surface of ceiling complete all as specified and directed (white washing shall be carried out using DDL).
M&L for one coat of white wash on already prepared surface of wall complete all as specified and directed. White washing shall be carried out using DDL.
M&L two coat oil bound distemper over a coat of primer of any tint on already prepared surface of walls complete all as specified and directed by Engr-in-Charge.
M&L for preparation of internal surface of wall and applying wall putty 2 to 3mm thick to make the surface smooth as specified and directed by Engr-in-Charge.
M&L for preparation of wall and applying exterior grade wall care putty 2 to 3mm thick to make the surface smooth as specified and directed by Engr-in-Charge.
M&L two coat of weather proof exterior emulsion paint on brick/concrete wall surfaces over and incl primer coat on walls on already prepared surface complete all as specified and directed by Engr-in-Charge.
M/ L for Writing letters or figures (Block. Roman, Italic or Indian) n exc. 30 cm high Writing bldg No with synthetic enamel paint complete all as specified and directed by Engr-in-Charge.
S&F in repair 25 mm dia stainless steel polished 204 grade drapery rod 1mm thick with final decorative, including brackets, decorative finished at both ends complete all as speccified and directed as per approved sample complete all as specified and ditected.
Taking down CI/AC/PVC pipes incl fittings upto 110mm dia and removing from site complete all as specified and directed.
S&F 100mm dia centrifugally cast (spun) iron pipe in any length with ears, with cement joints laid in trenches or in floors as per IS-3989-1984 complete all as specified and directed.
All as per item No 131 here-in-above but fixed to walls including necessary clamps complete all as specified.
S&F 75mm dia centrifugally cast (spun) iron pipe soil and waste pipe in any length with ears, with cement joints laid in trenches or in floors as per IS-3989-1984 complete all as specified and directed by Engr-in-Charge.
All as per item No 133 here-in-above but fixed to walls including necessary clamps complete all as specified and directed.
S&F centrifugally cast (spun) iron bends with cement joint any radius for 100 pipe.mm dia with duck 's foot or heel rest complete all as specified and directed.
S&F centrifugally cast (spun) iron bends with cement joint any radius for 75 pipe.mm dia with duck 's foot or heel rest complete all as specified and directed.
S&F centrifugally cast (spun) iron pipe branch peices, single(equal or unequal) ordinary or inverted (spigot or socket type), or with parrallel branches fitted with oval access doors of 100mm bore dia complete , fixed in repairs complete all as specified and directed.
S&F 75mm centrifugally cast (spun) iron branch piece single equal spigot or socket type fitted with oval access doors complete all as specified and directed.
S&F centrifugally cast (spun) iron bend (any radius) of 100mm bore with oval access door complete all as specified and directed.
S&F centrifugally cast (spun) iron bend (any radius) of 75mm bore with oval access door complete all as specified and directed.
S&F 100 mm dia centrifugally cast (spun) iron cowls complete all as specified and directed.
S&F 75mm dia centrifugally cast (spun) iron fioor trap with grating including jointing to waste pipe fixed in cement concrete type B 1(1:2:4) complete all as specified and directed.
S&F in repairs for 75mm bore dia pipe Stack clamps out of 50mm by 5mm flat iron & 16mm dia round iron stays, including bolts & nuts & securing ends of stay to wall or roof complete all as specified and directed.
S&F in repairs for 100mm bore dia pipe Stack clamps out of 50mm by 5mm flat iron & 16mm dia round iron stays, including bolts & nuts & securing ends of stay to wall or roof complete all as specified and direced by Engr-in-Charge.
S&F PVC (SWR) pipes of 110 mm dia, single socketed fixed to walls complete all as specified and directed by Engr-in-Charge.
S&F PVC (SWR) pipes of 75 mm dia, single socketed fixed to walls complete all as specified and directed by Engr-in-Charge.
S&F PVC (SWR) bends of 110 mm dia, any radius complete all as specified and directed by Engr-in-Charge.
S&F PVC (SWR) bends of75 mm dia, any radius complete all as specified and directed by Engr-in-Charge.
S&F PVC (SWR) junction single Tee equal or unequal 110 mm dia complete all as specified and directed by Engr-in-Charge.
S&F PV C (SWR) junction single Tee equal or unequal 75 mm dia complete all as specified and directed by Engr-in-Charge.
S&F PVC (SWR) floor trap, plain with grating including jointed with solvent cement of 75 mm outlet dia complete all as specified and directed by Engr-in-Charge.
S&F PVC (SWR) vent cowl 100mm dia complete all as specified and directed by Engr-in-Charge.
S&F PVC (SWR) vent cowl 75mm dia complete all as specified and directed by Engr-in-Charge.
S&F in repair sink coupling 32mm dia PTMT half or full threaded complete all as specified and directed by Engr-in-Charge.
S&F in repair CP steel Grating round with steel frame and hinge ,100mm dia complete all as sample approved by Engr-in-charge.
Cutting around the pipe 75/100mm bore waste pipe/soil pipe including taking out plant roots up to any depth in brick masonary and rejointing in pipe joint in appoxy mortar (Asian/Berger) and making good to existing surface all as directed by Engr-in-charge. (After the jointing pipe one week to be open for checking of leaking including necessary scaffolding)
M&L for taking down existing roof treatment of felt etc any thickness or description including cleaning all upto roof slab incluing removing spoil form site and M&L for providing roof treatment as per the following steps :- i) Filling cracks of roof slab with approved chemical sealing compound and applying 15mm thick renedering in CM 1:4 over neat cement slurry @ 3.00 Kg/Sqm over cleaned roof surface with use of approved water proofing compoung. ii) Applying a coat of cold applied bituminous primer @ 0.30 Kg/Sqm followed by APP modified five layer polymeric membrane 3mm thick, minium weight 3.60 Kg/Sqm reinforced with plyester non-woven fabric (weight not less than 150 gms/Sqm) manufactured by M/s STP Ltd or M/s Texsa India Ltd, laid as per the manufacturers instruction with side over lap of 75mm and end over lap of 100mm and finally finished with super silver sheild @ 0.10 Ltr/Sqm. Note : The work of water proofing treatment shall be got executed thorugh manufacturer or authorised applicator only.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for reinforcement cut as required to facilitate demolition, complete all as specified and directed
M&L 65-70mm for reinforced precast cement concrete 1:1:2 with 1.25mm thick MS sheet painted with bituminous paint around the manhole cover (using 20mm graded stone aggregate) as in landings, cover slabs ( for manholes etc.) vibromatic, articles with plain faces including necessary form work using surface vibrator, complete CA No and date of casting to be engraved on the cover slab by stencil and curing will be done in the water resverior all as specified and directed. (Reinforcement shall be measured and paid for separately under respective item of schedule ).
S&F TMT MS bar 8 mm dia & over, cut to length, bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including MS wire ( annealed) not less than 0.9 mm dia complete all as specified and dircted.
Supply, Installing, Commissioning and testing totally enclosed type (Silent operation with canopy CPCB II appoved), static type diesel engine driven generator set of capacity 40KVA/32 KW confirming to IS-4722, 415 Volt, 3 Phase, 4 wire complete including engine, alternator mounted on common base plate of rigid fabricated mild steel base frame all recommended by manufacturer and having following provisions all as specified and directed by Engineer-in-Charge. Make of Engine:Caterpiller STAMFORD/Crompton/CUMMINS INDIA LTD/Kirloskar/GC Make of Alternators:STAMFORD/Crompton/CUMMINS INDIA LTD/Kirloskar/GC
(a) Alternator :- Alternator shall be of capacity 40KVA/32 KW net out put at work site after considering derating factor as per Dehradun and temperature condition as applicable at power factor 0.8, AC 3 Phase, 4 wire, AVR system, screen protected, ball/roller bearing with damp proof cooper winding on each pole to base as pre relevant IS code all as specified (b) Diesel Engine :- Diesel engine shall be vertical type of adequate capacity suitable for above alternator after considering derating factor as per Dehradun confirming to relevant IS code having provision of coupling shaft to drive the above alternator independenlty after considering power loses in all the accessories forming part of the set i.e. coupling any type, Turbo charger, Fuel Pump, Fan etc. Engine should be of multistage, vertical multi cylinder water cooled, 4 stroke, common rail direct injection, cold starting, RPM 1500, industrial type, standard accessories complete in all respect including following provisions all as specified & directed :-
(Note :- DG set will be confirming to notification of Min of Environment). (i) Fly wheel with housing. (ii) Air clearance dry type (iii) Corrosion resisters. (iv) Fuel Filters, Oil Filters. (v) Electronic governer. (vi) Radiator including water pumping with Fan & belt. (vii) Silencer with buffers, tail pieces duly insulated with Asbestos/lagging and sufficiently extended to carry exhaust outside the DG Set building
(viii) Electrically starting system consisting of following items :- (a) Lead acid battery 12 volt 150 AH initially designed - 01 Nos (b) Self starting. (c) Alternator 12 Volt DC complete with holding clamps. (d) start/stop push button, ignition, switches with key system (e) Battery charging system including regulator and generator/alternator. (ix) Engine shall be with turbo charger. (x) Engine protection device low lubricant oil pressure high water temperature and high oil temp over speeding of engine. (xi) Water temp guage, oil temp guage, oil pressure guage, Ameter for display battery charging + Amps etc. (xii) MS fuel tank with breather suitable for 8 hours running on full load with level marking arrangement, stop cock, drain plug made out of 14 SWG sheet metal in built in side base frame inlet and out let connection. (xiii) Semi rotary hand operated pump complete with all accessories including holding clamp heavy duty. (xiv) Anti vibration pads suitable for 40 KVA DG set (xv) Rubber matting 20mm thick of size 2x1 metre size suitable for 11KV- A/U - each - 01 Nos
ACOUSTIC ENCLOSURE: Sheet metal fabricated cope type accoustic enclosure fabricated out of 1.6mm CRCA sheet, surface pre treated with foam materials and pure polyester powder coating complete , the enclosure shall be designed for reducing the sound level to 75 DB at a distance of 1 M from enclosure surface in free field condition suitable for using with AMF system and foundation etc complete all as specified and directed by Engg-in-charge and comprising of the following :- (i) Foundation/ Plinth/Base:- Shall be provided as per manufacturers recommendations, however minimum 0.5 m Space should be available all around the Set and height of plinth shall not be less than 0.5 M. (ii) Diesel storage tank:- Diesel storage tank of capacity adequate for storage of diesel for 8 hours operation of Gen Set. (iii) MISC: Tool kit, Operation and Maintenance catalogue, spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices.
AMF CONTROL PANEL SPECS : (i) Automatic Mains Failure (AMF) Control Panel, factory made shall be able to start up the DG set and transfer the load on to the DG set on mains failure without requiring any human intervention. Similarly on restoration of mains supply, it shall be able to transfer the load to mains supply and switch off the DG set automatically. (ii) The AMF panel shall be an enclosure with IP-53 degree of protection confirming to IS/IEC 0947 (Pt-1)/2007, fabricated from minimum 14 SWG thick CRCA sheet duly pre-treated and aesthetically finished. (iii) The AMF Control Panel shall have the following instruments: (a) Power control unit with bakelite LCD display having features or display Microprocessor based :- (i) Generator Voltage/AC Mains Voltage. (ii) Generator Current. (iii) Power Factor (iv) Frequency. (v) Energy. (vi) Three attempts Engine Start/Engine Cranking Relay. (vii) On -delay timer for Load Change Over. (viii) On-delay timer for Engine Shut Off. (ix) Over Current Relay
NOTES FOR ITEM NO.161 (i) The DG panel and AMF panel shall be complete with internal wiring with suitable size of multi stranded copper cable. The control cables and relays of various panels are included in the scope of this items. (ii) Tools shall be supplied as per manufacturer's instructions and rate quoted is deemed to be included in the cost of DG set (iii) Necessary grouting including mild steel work and anti vibration pad shall be provided by the contractor (iv) First filling of lubricants / engine oil/ Deisel for 10% over loading for one hour in twelve hours duration by artificial electric load test run deemed to be included in the rate quoted for the item. (v) Necessary PCC foundation alongwith one meter plinth protection including connected earth work for installation of DG Set shall be provided as per manufacturer's recommendation and cost deemed to be included in the rate quoted for the same. (vi) Necessary 10% over load test shall be carried out in the presence of Rep of accepting officer/IEM (vii) 2 Nos of chequered rubber Mat (Red colour) heavy duty size of 1 mtr x 2 Mtr x 19 mm with ISI marked complete deemed to be included in the rate quoted for the item. (viii) The contractor shall be carry out all electrical incoming/outgoing connection of cables including cable glands, thimbles, nut, bolt, washers, etc, cable will be measured and paid under respective items of schedule. (ix) Contractor shall submit the complete drawing of DG set with AMF panel which showing the complete drawing, capacities of all controlss, contacts, relays, etc including its make.
Supply & Laying XLPE insulated armoured heavy duty electric cable , with multi stranded aluminium conductor served with an inner sheathing of PVC type armoured with galvanized steel wire or tape and PVC sheathed 1100 volt grade,nominal cross sectional area 50 Sqmm 3.5 core including lugs and heat shrinkable PVC Sleeves on exposed surfaces & teflon tape duly insulated complete laid in trenches, ducts, drawn through pipe across the road/path/alongpoles/wall/floors/equipment etc including jointing and testing complete all as specified and directed by the Engr-in-charge.
Supply & Laying XLPE insulated armoured heavy duty electric cable , with multi stranded aluminium conductor served with an inner sheathing of PVC type armoured with galvanized steel wire or tape and PVC sheathed 1100 volt grade,nominal cross sectional area 10 Sqmm 4 core including lugs and heat shrinkable PVC Sleeves on exposed surfaces & teflon tape duly insulated complete laid in trenches, ducts, drawn through pipe across the road/path/alongpoles/wall/floors/equipment etc including jointing and testing complete all as specified and directed by the Engr-in-charge.
M&L for sand cushioning in trenches for protection of UG cable with river bed sand laid dry in trenches before and after laying of cable, including well ramming and consolidation complete all as specified and directed. (Punned thickness shall be measured)
Supply & Laying well burnt bricks, sub class 'B' brick laid breadth wise, along the cable in trenches after sand cushioning laid for protection of UG cable protection complete all as specified and directed.
Cutting existing road/hardstand of any type by using crow bar chisel uprto a depthof 30 cm for laying GI pipe including making good the surface by returning filling watering ramming in layers 150 mm thick PCC 1:2:4 over 200 mm thick hard core of broken bricks/stones over returning filling watering ramming in layers not exceeding 25 cm thick complete all as specified and directed
M&L for GI tubing medium grade (ISI marked) with all fitting/acessories for protection of cable on pole/wall and under road crossing including clamps, nut bolt etc all as specified and directed of size 50mm dia complete all as specified.
M & L PCC (1:4:8) type D-2 (using 40mm graded caushed stone aggregate) as in foundation of poles and stay etc including form work complete all as specified.
M&L for PCC 1:3;6 type C-1 (using 20 mm crushed stone aggregate) as in coping of poles etc including form work complete all as specified and directed by Engineer-in charge.
Taking down carefully copper/Aluminum point wiring (light, fan socket and power) complete including switches, ceiling rose lamp holder and regulator etc and removing from site and making good disturbed surfaces of walls/floors etc complete all as specified and directed by Eng-in-charge.
M&L for point wiring with 1.5 Sqmm. (nominal area) FRLS, single core PVC insulated 1100 Volts, grade multistranded copper conductor unsheathed in and including concealed PVC conduit medium duty 20 mm dia or higher and heavy grade conduit fittings and heavy duty accessories with suitable size of sunk type cast iron or pressed steel terminal box 1.6mm thick for mounting of switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet as top cover, one green colour FRLS cable of same size as earth wire up to common earth and connected to earth dolly compete all as specified and directed by Eng.-in-charge of following:- Note: The wiring to be done as per IE rule and maintain colour code accordingly.
One light point /bell buzzer point controlled by one-one way switch.
One ceiling fan/Exhaust fan point controlled by one-one way switch through Regulator.
One three pin 5 Amp socket on same board with other switches.
One three pin 5 Amp socket on independent board
One light point controlled by two nos two way switch
All as per item No.171 here-in-above but with 4 Sqmm cable for one 6 pin 15A socket outlet point on independent board
All as per item No 171 here-in-above but one 3 pin socket outlet 15 Amp independent, with cable 2.5 Sq mm size, with earth continuity coductor of size 1.5 Sq mm.
S&F bell push 5 Amps, single pole complete all as specified and directed.
S&F electric bell, AC 230V, single pole complete all as specified and as directed.
S&F switch piano flush, button type 5 Amp SP 250 V AC complete all as specified & directed.
S&F switch piano flush button type 15 Amps SP 250 V AC complete all as specified & directed.
S&F socket outlet multipurpose 3 Pin 5 Amp and 2 Pin 5 Amps 250 V AC complete all as specified & directed.
S&F socket outlet two in one three pin 5 Amp and 15 Amp 2 module 120 W flush type complete al as specified.
S&F switch socket combination 5 Amps, 5 pin, 2 in 1 complete all as specified and directed
S&F switch socket combination multipurpose 5 & 15 Amps, 5 pin, 2 in 1 complete all as specified and directed
S&F switch paino flush button type 5 Amp SP 2 way complete 250 V AC complete all as specified and directed.
S&F step type regulator socket type double module 5 step for ceiling fan 1200/1400 mm size 230 volts 6 Amp 400 watts complete all as specified and directed..
S&F ceiling rose, 3 terminal/PVC/polycarbonate, isolated body 250 V AC complete all as specified and directed..
M&L lamp holder insulated body with back plate suitable for angle and batten fitting complete all as specified.
S&F in replacement flood light fittings. Energy saving environmental friendly, long life, exclusive innovative epoxy powder coated die-cast aluminium housing IP66 flood light with high power LED's as light sources, suitable for high lighting architectural features or retail spaces as 82/100/110 watt or higher size LED , Glass cover, fixed on pole duly fixed on angle iron bracket complete all as specified and directed.
S&F Exhaust fans AC single phase 230/ 240 V, metallic range of size 300 mm sweep,50 Hz with louver of size 300 mm sweep, complete with louvers, shutters and connecting up ceiling rose to connector block of fan including making of holes and grouting of nuts and bolts PCC (1:2:4) B-1 block including taking down old metalic exhaust fan complete all as specified and directed. (Old fans will be deposited in AGE E/M store yard)
S&F in replacement Exhaust fan exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m, complete with louvers, shutters and connecting up ceiling rose to connector block of fan including making of holes and grouting of nuts and bolts PCC (1:2:4) B-1 block including taking down old metalic exhaust fan complete all as specified and directed. (Old fans will be deposited in AGE E/M store yard)
S&F in replacement Water Heater storage type, electric, capacity 35 litres AC single phase 230/ 240 Volt and connecting up including making of holes and grouting of nuts and bolts PCC (1:2:4) B-1 block complete all as specified and directed. (Old geysers will be deposited in AGE E/M store yard)
M&L in replacement sub main wiring with 2 Single core PVC insulated unsheathed FRLS cable 1100 Volts grade heavy duty copper conductor multistranded of size 10 Sqmm. (nominal area) drawing in and including 20 mm dia or higher PVC concealed conduit heavy duty accessories and fittings. PVC insulated unsheathed FRLS cable copper conductor multistranded of size 6 Sq. mm. as earth wire upto common earth and connected to earth dolly complete all as specified & directed. Note:- Three runs of wire and one run of conduit shall be measured as one unit. length.
M&L in replacement submain wiring with 3 runs(1 run for Phase+1 run for Neutral &1 run for Earth, with approved colour code as per EI rules) of 4 Sqmm single core,PVC insulated, unsheathed, multistranded copper conductor FRLS cable 1100 volts grade drawn through and including concealed wiring with PVC conduit pipe of medium duty not less than 15 mm dia including necessary steel conduit specials and connecting with suitable size thimble, and making good surface of disturbed wall/ceiling/floor as match with existing complete all as specified and directed. Note:-3 runs of 4 Sqmm size PVC copper cable, and one run of PVC conduit shall be measured as one unit length.
S&F in replacement sheet metal enclosures 240 volt with 200 Amp rated bus bar for double door 8 way DB,s IP-43 IK 09 metal door suitable for one MCB SPN as incoming and 06 MCB SP as out going complete all as specified and directed.
S&F MCB double pole 240 Volt 10 KA 40 Amp 'B' series conforming to ISI marked complete all as specified & directed.
S&F MCB single pole and 240 volt 10 KA 5-32 Amp 'B' series conforming to ISI marked complete all as specified and directed.
S&F in replacement wall mounted tube light fitting 1x20/22 watts extruded aluminium polycarbonate covers PF 0.9 and above operating voltage 140V-270V colour temp 6500K & lumen input output 95 Lumen per watt and connected to ceiling rose with required length of two core flexible copper cable 23/0.0076 fixed on wall/roof complete all as specified and directed. Make: Philips cat part No TMC 501P1xT LED 22WP-3241(Tube Batten) and MAS LE$D 1200mm 18W-865-T-81 (Tube) / Wipro Cat part No WI0922208 (Tube Batten) LL13-181-65SE (Tube)/ Havells Cat Part No LUMILINEPLUSBS20WLED865SPCSS (Tube Batten)CRYSTAL1213T8DSTL20WLED865SGLASS(TUBE DOUBLE SIDE)
S&F in replacement LED light fitting decorative wall mounting SS brush finish fixture with frosted glass suitable for upto 1x40 watt mini glass lamp with and including one no 12 watt LED lamp. complete with accessories and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified. Make : Havells Cat Part NO LHFOAJE1TN1IO60 or equivelent in Bajaj/ Philips etc as approved.
Materials and labour for earthing complete with galvanised iron earth plate electrode of size 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with and including galvanised earth strip of size 32 x 6mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed by the Engr-in-Charge.
Materials and Labour for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground end vertically to a depth not less than 2.25 meter deep below ground level with top edge of the earth plate at a depth not less than 1.5 M below normal ground level connected to galvanized steel earth wire 4 mm dia by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1, cover slab 54 cm x 54 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm c/c both ways, and with one handle for lifting made out of 10 mm dia MS round bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 15 mm bore galvanized steel tubing (light grade) for protection of earth lead connection, including necessary excavation and earth work in any type of soil and necessary testing complete all as shown on electrical plate No 3 of SSR Part –I (2009) and as directed.
Taking down old u/s DB/main switch/Metal clad box of any size complete with MCBs and removing u/s materials out of site
S & F sheet metal enclosure TPN for DB's when MCB's to be used 8 way with 200 amps bus bar and double door complete all as specified and directed.
S&F Sheet metal enclosure SPN for DB's when MCB's to be used 8 way with 200 amps bus bar double door
S&F MCB TPN 63 Amp, 415 Volts,10 KA 'C' series with all incoming/outgoing connections with proper size of lugs complete all as specified and directed.
All as per item No 202 here-in-above but MCB SP 6 to 32Amp complete all as specified and directed.
S&F Residuel Circuit Breaker (RCOB) for earth leakage, overload & short circuit protection four pole 30 mAof capacity 100 Amps complete all as specified and directed.
S & F MCB SPN 32 Amps,240 Volts,10 KA 'C' series with all incoming/outgoing connections with proper size of lugs complete all as specified and directed. Make Indoasian Part No 810014 or equivalent Crompton/L&T/Anchor/Legrand
S&F Sheet metal enclosures with socket plug top and MCB' SPN enclosure with a two pin and earth plug and socket complete with one single pole 20 A MCB complete all as specified and directed.
Taking down fan, ceiling fan end, dismantling blades and removing fan and blades to store, removing capacitor carefully for overhauling checking serviceability of bearings/bush, winding etc cleaning the fan reassembling after replacing the unserviceable parts such as capacitor, rubber bush, split pins, nut & bolts complete (To be paid under relevant item of the Sch 'A'), and testing the same, hanging ceiling fan connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and directed by Engineer-in-Charge .
Rewinding of ceiling fan with same gauge as per existing gauge super enamalled copper wire including varnishing, drying paper insulation material complete of 1200 mm sweep.complete all as specified and directed
S&F in replacement LED tube light alluminium extruded body with intergrated electronic driver , 20 W complete all as specified and directed. Make Philips Cat No BN 021 LED40S- 6500 PSU GR (4 ft) or equivalent in Bajaj/Havells/C&G.
S&F in replacement LED Mirror light fitting tube light alluminium extruded body with intergrated electronic driver along with fixture, 10 W complete all as specified and directed. Make Wipro Model Trim Neo LL20-111-XXX-65NE3 or equivalent in Bajaj/Havells/C&G.
S&F in replacement fans ceiling complete with electronic type regulator and accessories 230 V,1200 mm sweep PVC AC single Phase 230 V / 240V 50 Hz of , connecting up ceiling rose to connector block of fan including fabricating and fixing of Fan hooks from ceiling truss/angle iron, required length of down rods (As per site requirement) and necessary nuts and bolts complete all as specified and directed. (Old fans will be deposited in AGE E/M store yard)
Supplying, transporting, errecting and fixing Steel tubular swaged poles type 410 SP-31, 8.50 metre long , complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified including painting with two coats of synthetic enamalled paint over one coat of red oxide primer and 06 Nos bands/ straps with yellow and black colour ( 30 cm wide each)epoxy heat resistant paint at a distance 30 cm from plinth block and numbering of poles with black synthetic enamel paint in 2.5 cm height including tarring/Bituminous paint one coat on steel surface embedded in concrete foundation complete all as specified and shown on drawings and directed. Make : M/S ANil Engg Corporation Kanpur/National Tubing Co Kanpur/M/S sohan lal and sons
Supply and Fixing street light bracket made out of 40 mm dia GI pipe light grade bend to shape welding etc and fixing on wall with 40x6 mm flat iron MS clamps including necessary nuts, bolts and washers etc complete all as specified and as directed.
S&F S&F junction box made of glass fibre reinforced and transparent poly carbonate of size 126x228x111, KV PC 8104 with IP 65 protection including MCB SP, 6 Amps 1 No and suitable size clamps fixing for pole/in pcc foundation etc,including taking down the old one, complete all as specified and as directed. Make :-Hensel or equivalent in sintex/ universal.
M&L PVC insulated copper conductor 3 core 1.5 sqmm cable to be drawn inside the pole , including taking down of old one, complete all as specified & as directed.
SRI GANESH ENTERPRISES
M/S SETHI BROTHERS
M/S C S AITHANI
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .