This tender is floated for supply, installation, testing and commissioning of Energy Management System
22000685-HD-10157
22000685-HD-10157
Open Tender
Ludhiana, Punjab
₹0
Exempted
10 Jan 2023
21 Dec 2022
10 Jan 2023
10 Jan 2023
22 Dec 2022 - 31 Dec 2022
| Item No | Item Title | Description | Qty | Unit |
|---|---|---|---|---|
| 1 | POWER QLTY ANALYZER | POWER QLTY ANALYZER — ITEM DESCRIPTION:3 PHASE POWER QUALITY ANALYZER; TYPE:N/A; RANGE:N/A; DIMENSION:N/A; MODEL:N/A; AS PER SPECIFICATION MENTIONED IN ATTACHMENT-2 | - | Each |
| 2 | MULTIFUNCTION METER | MULTIFUNCTION METER — ITEM DESCRIPTION:MULTIFUNCTION METER; TYPE:N/A; RANGE:N/A; DIMENSION:N/A; MODEL:N/A; MANUFACTURER:SCHNEIDER ELECTRIC, L&T OR EQUIVALENT; INPUT VOLTAGE RANGE:VT PRIMARY:999 KV L-L MAX, WITH PROGRAMMABLE CT/PT RATIOS SUITABLE FOR LT SYSTEMS, VALUES TO BE DISPLAYED:AVERAGE LINE CURRENT OF 3-PHASE, PER-PHASE, AND CALCULATED NEUTRAL CURRENT, AVERAGE VOLTAGE OF L-L, L-N PARAMETERS, AND PER-PHASE, FREQUENCY, REAL, REACTIVE AND APPARENT POWER, DISPLACEMENT POWER FACTOR ETC | - | Each |
| 3 | GATEWAY | GATEWAY — PART NAME:COMMUNICATION GATEWAY; PART MATERIAL:N/A; PART RATING:N/A; PART NUMBER:N/A; MANUFACTURER:N/A; CONTROLLER/ROUTER/INTEGRATOR WITH TCPIP CONNECTIVITY AND NETWORK BUS CONNECTIVITY TO CONNECT TO THE BMS SERVER SOFTWARE FOR INTEGRATION OF AHU EC FANS, FAN VFD, VAV, DG PROCESSOR PANEL, UPS, APFCR RELAY, AND OTHER UTILITIES AS DEFINED IN THE IO LIST FORMING PART OF THE BIDDING DOCUMENT ON RS485 MODBUS/LON WORKS PROTOCOL INCLUDING ALL ACCESSORIES AND FITTINGS, ALL COMPLETE AS PER APPROVED DRAWINGS AND SPECIFICATIONS OF THIS TENDER AND DIRECTIONS OF ENGINEER-IN-CHARGE | - | Each |
| 4 | SPLY & INSTLN ETHERNET | SPLY & INSTLN ETHERNET — SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF ETHERNET GATEWAY WITH POWER SUPPLY. 1 ETHERNET PORT (10/100 BASE T), INBUILT WEB DASHBOARD, CUSTOM WEB PAGE SUPPORT, REAL-TIME TRENDING, DEVICE DISCOVERY, TCP/IP, SNMP, SNTP, SMTP PROTOCOL, AUX SUPPLY 24 V DC. APPROVED MAKE. THE ITEM ALSO INCLUDES RACK/ENCLOSURE AS REQUIRED FOR THE GATEWAY. | - | Each |
| 5 | SITC of DCU | SITC of DCU | - | Each |
| 6 | SITC of Branch circuit manager | SITC of Branch circuit manager | - | Each |
| 7 | CAMC FOR SUPPLIED | CAMC FOR SUPPLIED — COMPREHENSIVE AMC FOR 5 YEARS FOR COMPLETE TAS SYSTEM PROVIDED, COST OF ALL SPARES, EQUIPMENT INST. AND SERVICES (PREVENTIVE AND BREAKDOWN) DURING CAMC BY VENDOR, AS PER TENDER SCOPE, TERMS AND CONDITIONS. | - | Lump Sum |
| 8 | SPLY&LAYG OF CAT6 CABLE | SPLY&LAYG OF CAT6 CABLE — SUPPLY AND LAYING OF CAT 6 CABLES, DATA POINT WIRING USING CAT6, 4PAIR TWISTED COMPUTER NETWORKING CABLE SPECIFICATIONS CONFORMING TO ALL TIA/EIA AND ISO CATEGORY6, CLASS E REQUIREMENTS, SCREENED AND SHIELDED IN 1 IN OR 1.5 IN PVC CONDUIT PIPE (PIPE WILL BE PID SEPARATELY IN RESPECTIVE ITEM)PARTLY FULLY CONCEALED IN ALL TYPES OF WALLS, FLOORS, WOODEN PARTITIONS, MODULAR FURNITURE’S, ABOVE FALSE CEILINGS ETC. COMPLETE WITH ALL ACCESSORIES, INCLUDING WIRING TERMINATORS, CONNECTED CIVIL WORKS, ROUGH PLASTERING ETC. THE ABOVE WORK INCLUDES FERRULING AND TERMINATION OF CABLES AT BOTH ENDS. ONE END OF THE CABLE SHOULD BE TERMINATED IN THE INFORMATION OUTLET & THE OTHER END SHOULD BE TERMINATED IN THE JACK PANEL. CABLES SHALL BE COILED IN THE IN-WALL OR SURFACE-MOUNT BOXES IF ADEQUATE SPACE IS PRESENT TO HOUSE THE CABLE COIL WITHOUT EXCEEDING THE MANUFACTURER’S BEND RADIUS. IN HOLLOW WALL INSTALLATIONS WHERE BOX-ELIMINATORS ARE USED, EXCESS WIRE CAN BE STORED IN THE WALL. NO MORE THAN 300MM OF SLACK SHALL BE STORED IN A WALL BOX, MODULAR FURNITURE RACEWAY, OR INSULATED WALLS. EXCESS SLACK MAY BE NEATLY COILED AND STORED IN THE CEILING OR RAISED ACCESS FLOOR FOR EACH DROP LOCATION WHEN THERE IS NOT ENOUGH SPACE PRESENT IN THE OUTLET BOX TO STORE SLACK CABLE. CABLES SHALL BE DRESSED AND TERMINATED IN ACCORDANCE WITH THE RECOMMENDATIONS MADE IN THE ISO/IEC 11801 2ND EDITION DOCUMENT, MANUFACTURER’S RECOMMENDATIONS AND/OR BEST INDUSTRY PRACTICES. PAIR UNTWIST AT THE TERMINATION SHALL NOT EXCEED 6MM FOR CATEGORY 6A / CLASS EA CONNECTING HARDWARE. BEND RADIUS OF THE CABLE IN THE TERMINATION AREA SHALL NOT BE LESS THAN 4 TIMES THE OUTSIDE DIAMETER OF THE CABLE. THE CABLE JACKET SHALL BE MAINTAINED AS CLOSE AS POSSIBLE TO THE TERMINATION POINT. CABLES SHALL BE INSTALLED IN CONTINUOUS LENGTHS FROM ORIGIN TO DESTINATION (NO SPLICES) UNLESS SPECIFICALLY ADDRESSED IN THIS DOCUMENT. | - | Running Meter |
| 9 | SUPLY OF OFC | SUPLY OF OFC — SUPPLY OF 24-CORE, SINGLE MODE,MULTI TUBE, STEEL TAPED ARMORED OPTICAL FIBER CABLE, SHIELDED ADHERING TO ITU-T G.652, ASPER ATTACHED DATASHEET, STANDARD SPECIFICATIONS INCLIDING FACTORY TESTING, INSPECTION, PACKAGING, FORWARDING, TRANSPORTATION, INSURANCE, RECEIPT AND STORAGE AT SITE. | - | Meters |
| 10 | RS 485 DATA CABLE,3105 A | RS 485 DATA CABLE,3105 A — PART NAME:RS 485 DATA CABLE; PART MATERIAL:N/A; PART RATING:N/A; PART NUMBER:3105 A; MANUFACTURER:BELDEN | - | Meters |