Loading…
Loading…
Tender Value
₹27 L
EMD Value
₹27,000
Closing Date
16 Jun 2026, 4:00 pm6d left
kim ind division
ARC work of HT/LT lines, T/C, maintenance (including raising of plinth, TC Booting, MVCC Stringing) & O/H Laying of XLPE Cable Pole to Pole of feeders for SI and any Other Scheme in the jurisdiction of Mota Borasara Sdn under KIM ind Division. Through outsourced agency for existing DGVCL Network for SDN under Kim Division.
312725
KIM/O&M/TECH/N-PROCURE/26-27/01/SR-10 DT:09-06-2026
Open
Electrical and Maintenance Works
Surat
5 documents required · 5 mandatory
₹1,180
DAKSHIN GUJARAT VIJ COMPANY LTD.
₹27,000
9 Jun 2026
9 Jun 2026
9 Jun 2026
16 Jun 2026
9 Jun 2026
Name of Work :- Rate contract for erection of HT/LT line & T/C work for various scheme work for SDN
office under Kim Ind Division Office.
ITEM CODE Details of Works Qty Unit Labour Rate Amount
HT TAPPING FROM THE EXISTING
POLE INCLUDING FIXING OF CROSS
ARMS, CLAMPS ANTI-CLIMBING
DEVICES, DANGER BOARD,
INSULATORS ETC. COMPLETE AND
1 9926000001 PAINTING OF FABRICATED MATERIALS No.
AND NUMBERING COMPLETE WITH
COST OF PAINTS AS PER STANDARD
SPECIFICATION BUT EXCLUDING
ERECTION OF GUY SET AND
ERECTION OF PSC POLES OF 8 *200
KG INCLUDING EXCAVATION OF PIT
AND REFILLING OF EARTH, FIXING
OFCROSS ARMS, TOP FITTING CLAMPS
ANTI-CLIMBING DEVICES, INSULATORS
ETC. COMPLETE AND PAINTING OF
FABRICATED MATERIALS USED ON
THE POLES AND NUMBERING WITH
COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING
ERECTION OF GUY SET AND
File No: DGVCLDOKI/TEN/e-file/6817/2026/2939/Account
Approved By: Executive Engineer,Technical,DGVCLDOKI
Letter No: DGVCLDOKI/0303/06/2026 Approved Date: 08-06-2026
ERECTION OF STEEL POLES OF 9 TO
11 METERS INCLUDING EXCAVATION
OF PIT AND REFILLING OF EARTH,
FIXING OFCROSS ARMS, TOP FITTING
CLAMPS ANTI-CLIMBING DEVICES,
DANGER BOARD, INSULATORS ETC.
3 9926000003 COMPLETE AND PAINTING OF STEEL No.
POLE, FABRICATED MATERIALS USED
ON THE POLEAND NUMBERING WITH
COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING
ERECTION OF GUY SET AND
ERECTION OF STEEL POLE OF
METERS FOR RAILWAY CROSSING ON
BG/MG/NG LINE FOR 0.400/11/22KV
OVERHEAD LINES I.E INCLUDING
EXCAVATION OF PIT & REFILLING OF
EARTH, FIXING CROSS ARMS, TOP
FITTING CLAMPS,ANTI-CLIMBING
DEVICES DANGER BOARD,
INSULATORS ETC. COMPLETE AND
PAINTING OF STEEL POLES,
FABRICATED MATERIALS USED ON
THE POLES AND NUMBERING WITH
COSTOF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING
ERECTION OF GUY SETS AND
ERECTION OF DOUBLE POLE
STRUCTURE OF 8 METERS 200 KG PSC
POLES INCLUDING EXCAVATION OF
PITS & REFILLING OF EARTHING,
FIXING OF CHANNELS, SUPPORTING
ANGLES,CLAMPS, ANTI-CLIMBING
BOARDS,INSULATORS ETC.COMPLETE
AND PAINTING OF FABRICATED
MATERIALS USED ON THE POLES AND
NUMBERING WITH COST OF PAINT AS
PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SETS
AND EARTHING.(WITHOUT AB SWITCH)
File No: DGVCLDOKI/TEN/e-file/6817/2026/2939/Account
Approved By: Executive Engineer,Technical,DGVCLDOKI
Letter No: DGVCLDOKI/0303/06/2026 Approved Date: 08-06-2026
ERECTION OF DOUBLE POLE
STRUCTURE OF 9 TO
METERS.STEEL POLE INCLUDING
EXCAVATION OF PITS & REFILLING
OFEARTH, FIXING OF CHANNELS,
SUPPORTING ANGLES, CLAMPS,ANTI-
CLIMBING DEVICES DANGER BOARDS,
6 9926000006 INSULATORS ETC.COMPLETE & No.
PAINTING OF POLES,FABRICATED
MATERIALSUSED ON THE POLES AND
NUMBERING WITH COST OF PAINTSAS
PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SET
AND EARTHING.(WITHOUT AB SWITCH)
ERECTION OF DOUBLE POLE
STRUCTURE WITH MOUNTING OF AB
SWITCH, HG FUSES OF 8 MTRS 200 KG
PSC POLES INCLUDING EXCAVATION
OF PITS AND REFILLING OF
EARTH,FIXING OF CHANNELS
SUPPORTING ANGLES, CLAMPS, ANTI-
CLIMBING DEVICES, DANGER BOARDS,
INSULATORS,DOFUSES ETC.
COMPLETE AND PAINTING OF
FABRICATED MATERIALS USED ON
THE POLES AND NUMBERING WITH
COSTOF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDINGOF
ERECTION OF GUY SET AND
EARTHING.(WITH AB SWITCH)
ERECTION OF DOUBLE POLE
STRUCTURE WITH MOUNTING OF AB
SWITCH,HG FUSES, 9 TO 11 METERS
STEEL POLES INCLUDING
EXCAVATION OF PITS AND REFILLING
OF EARTH, FIXING OFCHANNEL,
SUPPORTING ANGLES, CLAMPS, ANTI-
CLIMBING DEVICES , DANGER
BOARDS, INSULATORS, ETC.
COMPLETE AND PAINTING OF POLES
FABRICATED MATERIALS USED ON
THE POLES AND NUMBERING WITH
COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING
ERECTION OF GUY SET AND
EARTHING.(WITH AB SWITCH)
File No: DGVCLDOKI/TEN/e-file/6817/2026/2939/Account
Approved By: Executive Engineer,Technical,DGVCLDOKI
Letter No: DGVCLDOKI/0303/06/2026 Approved Date: 08-06-2026
ERECTION OF DOUBLE POLE
STRUCTURES WITH MOUNTING OFAB
SWITCH, HG FUSES,
TRANSFORMERS, LIGHTENING
ARRESTORS, DISTRIBUTION BOX.
OF 8 METER,200KG PSC POLE METERS
POLES INCLUDING EXCAVATION OF
PITS AND REFILLING OF EARTH,
CARTING OF TRANSFORMERS
FROMSTORES TO SITE, FIXING OF
9 9926000009 CHANNELS, SUPPORTING No.
ANGLES,BRACINGS CROSS ARMS
CLAMPS, ANTICLIMBING DEVICES
DANGER BOARDS, CONDUCTOR AND
CABLE WIRING ETC.COMPLETE AND
PAINTING OF FABRICATED MATERIALS
USEDON THE POLES AND NUMBERING
WITH COST OF PAINT AS PER
STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SETS
ERECTION OF DOUBLE POLE
STRUCTURE WITH MOUNTING OF AB
SWITCH,HG FUSES TRANSFORMERS,
LIGHTENING ARRESTORS,
DISTRIBUTION BOX 9 TO 11 METERS
STEEL POLES INCLUDING
EXCAVATION OF PITS & REFILLING OF
EARTH CARTING OF TRANSFORMERS
FROM STORE TO SITE, FIXINGOF
CHANNELS SUPPORTING ANGLES,
BRACING, CROSS ARMS,CLAMPS,
ANTICLIMBING DEVICES, DANGER
BOARDS,CONDUCTOR AND CABLE
WIRING ETC. COMPLETE AND
PAINTING OF POLES FABRICATED
MATERIALS USED ON THE POLES AND
NUMBERING AS PER STANDARD
SPECIFICATION BUT EXCLUDING
ERECTIONS OF GUY SETS AND
ERECTION OF GUY SET INCLUDING
EXCAVATION OF PITS & REFILLING OF
EARTH AS PER STANDARD
SPECIFICATION WITH STAY CLAMPS,
STAY WIRE, ANCHOR ROD, TURN
BUCKLE, EYEBOLT, GUY INSULATOR,
CEMENT CONCRETE BLOCK ETC. BUT
EXCLUDING CONCRETING.
File No: DGVCLDOKI/TEN/e-file/6817/2026/2939/Account
Approved By: Executive Engineer,Technical,DGVCLDOKI
Letter No: DGVCLDOKI/0303/06/2026 Approved Date: 08-06-2026
CONCRETING OF POLES, GUYS, ETC.
INCLUDING COST OF CEMENT SAND
12 9926000012 METAL (1:2:4) AND WATER ETC. AS PER CMT
STANDARD SPECIFICATION.(cement
Should be 53 grade) used for Concreting.
ERECTION OF COIL TYPE EARTHING
INCLUDING COST OF COAL,SALT ETC.
13 9926000013 BUT WITHOUT COST OF GI WIRE AS No.
PER STANDARD SPECIFICATION(20kg
solt+20kg coal)
ERECTION OF GI PIPE/CI PLATE TYPE
EARTHING INCLUDINGCOST OF COAL
SALT ETC. BUT WITHOUT COST OF
PIPE/GIPLATE GI WIRE AS PER
STANDARD SPECIFICATION.(20kg
solt+20kg coal)
ERECTION OF STREET LIGHT FIXTURE
COMPLETE WITH CLAMPS, BRASS
NIPPLE, BRASS HOLDER TECK WOOD
15 9926000015 BUSH,REFLECTORS FUSE, WIRING No.
ETC. AS PER STANDARD
SPECIFICATION BUT EXCLUDING COST
OF(30mm2)ACSR/34MM@,55MM2 AAA
CONDUCTOR for ALL TYPE OF
16 9926000016 CONDUCTOR (EXCEPT DOG
CONDUCTOR) FOR 11/22KV & LT LINES
INCLUDING FIXING OF INSULATORS,
BINDING JUMPERING ETC.
STRINGING OF GI WIRE 8 SWG
INCLUDING BINDING JUMPERING ETC.
PROVIDING SINGLE PHASE SERVICE
CONNECTION WITH PVC 2.5/4MM2
TWIN CORE CABLE FROM TERMINAL
POLE TO METERING POINT INCLUDING
FIXING OF METER WITH METER
EARTHING COMPLETE WORK AS PER
STANDARD SPECIFICATION BUT
EXCLUDING COST OF MATERIALS.
PROVIDING THREE PHASE 4 WIRE
SERVICE CONNECTION WITH PVC
4MM2/10MM2 FOUR CORE CABLE
FROM TERMINAL POLE TO METERING
19 9926000019 POINT INCLUDING FIXING OF METER No.
WITH METER EARTHING COMPLETE
WORK AS PER STANDARD
SPECIFICATION BUT EXCLUDING COST
File No: DGVCLDOKI/TEN/e-file/6817/2026/2939/Account
Approved By: Executive Engineer,Technical,DGVCLDOKI
Letter No: DGVCLDOKI/0303/06/2026 Approved Date: 08-06-2026
ADDITIONAL COST FOR EXCAVATION
OF PIT IN HARD ROCK AREA FOR
ERECTION OF POLE/ GUY ETC. AS PER
STANDARD SPECIFICATION OVER &
ABOVE NORMAL COST COVERED
20 9926000020 AGAINST EXCAVATION OF PIT UNDER No.
NORMAL SOIL FOR ERECTION OF
POLE,GUY, DOUBLE POLE STRUCTURE
EARTHING WITH THE APPROVAL OF
SUPDT.ENGINEER.
PROVIDING GUARDING TO HT LINE ON
ROAD/ RAIL CROSSING.
PROVIDING GUARDING OF LT LINES
ON ROAD/RAIL CROSSING.
23 9926000023 LT LINE TAPPING- SINGLE PHASE No. 51
24 9926000024 LT LINE TAPPING- THREE PHASE No. 93
Stringing/LAYING OF OVER HEAD LT
CABLE FOR ROAD CROSSING,HT LINE
CROSSING AND TELEPHONE LINE
CROSSING ETC.(PER SPAN)
ERECTION OF SINGLE POLE
STRUCTURES WITH , HG
FUSES,TRANSFORMERS, LIGHTENING
ARRESTOR, DISTRIBUTION BOX. ON
METERS 200 KGAND PSC POLE
INCLUDING EXCAVATION OF PITS AND
REFILLING OF EARTH, CARTING OF
TRANSFORMERS FROM STORES TO
SITE, FIXING OF CHANNELS,
SUPPORTING ANGLES,BRACINGS
CROSS ARMS CLAMPS, ANTICLIMBING
DEVICES DANGER BOARDS,
CONDUCTOR AND CABLE WIRING
ETC.COMPLETE AND PAINTING OF
FABRICATED MATERIALS USED ON
THE POLE AND NUMBERING WITH
COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING
ERECTION OFGUY SETS AND
File No: DGVCLDOKI/TEN/e-file/6817/2026/2939/Account
Approved By: Executive Engineer,Technical,DGVCLDOKI
Letter No: DGVCLDOKI/0303/06/2026 Approved Date: 08-06-2026
ERECTION OF SINGLE POLE
STRUCTURES WITH MOUNTING OFAB
SWITCH , HG FUSES,TRANSFORMERS,
LIGHTENINGARRESTOR, DISTRIBUTION
BOX. ON 9 to 11 METERS RSJ POLE
INCLUDING EXCAVATION OF PITS AND
REFILLING OF EARTH, CARTING OF
TRANSFORMERS FROM STORES TO
SITE, FIXING OF CHANNELS,
SUPPORTING ANGLES,BRACINGS
CROSS ARMS CLAMPS, ANTICLIMBING
DEVICES DANGER BOARDS,
CONDUCTOR AND CABLE WIRING
ETC.COMPLETE AND PAINTING OF
FABRICATED MATERIALS USED ON
THE POLE AND NUMBERING WITH
COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING
ERECTION OFGUY SETS AND
ERECTION OF PSC POLES OF 10 *270
KG INCLUDING EXCAVATION OF PIT
AND REFILLING OF EARTH, FIXING OF
CROSS ARMS, TOP FITTING CLAMPS
ANTI-CLIMBING DEVICES, INSULATORS
ETC. COMPLETE AND PAINTING OF
FABRICATED MATERIALS USED ON
THE POLES AND NUMBERING WITH
COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING
ERECTION OF GUY SET AND
ERECTION OF DOUBLE POLE
STRUCTURE OF 10 METERS 270 KG
PSC POLES INCLUDING EXCAVATION
OF PITS & REFILLING OF EARTHING,
FIXING OF CHANNELS, SUPPORTING
ANGLES,CLAMPS, ANTI-CLIMBING
BOARDS,INSULATORS ETC.COMPLETE
AND PAINTING OF FABRICATED
MATERIALS USED ON THE POLES AND
NUMBERING WITH COST OF PAINT AS
PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SETS
AND EARTHING.(WITHOUT AB SWITCH)
STRINGING OF 100MM2 ACSR/100MM2
AAAC CONDUCTOR FOR 11/22KV & LT
30 9926000030 LINES INCLUDING FIXING
OFINSULATORS, BINDING JUMPERING PER KM
File No: DGVCLDOKI/TEN/e-file/6817/2026/2939/Account
Approved By: Executive Engineer,Technical,DGVCLDOKI
Letter No: DGVCLDOKI/0303/06/2026 Approved Date: 08-06-2026
STRINGING OF DOG CONDUCTOR FOR
11/22KV & HT LINES INCLUDING FIXING ONE COND
OF INSULATORS, BINDING JUMPERING PER KM
ERECTION OF DOUBLE POLE
STRUCTURES WITH MOUNTING OF AB
SWITCH, HG FUSES,
TRANSFORMERS, LIGHTENING
ARRESTORS, DISTRIBUTION BOX.
OF 10 METERS 270 KGAND PSC POLES
INCLUDING EXCAVATION OF PITS AND
REFILLING OF EARTH, CARTING OF
TRANSFORMERS FROMSTORES TO
SITE, FIXING OF CHANNELS,
32 9926000032 SUPPORTING ANGLES,BRACINGS No.
CROSS ARMS CLAMPS, ANTI-CLIMBING
DEVICES,DANGER BOARDS,
CONDUCTOR AND CABLE WIRING
ETC.COMPLETE AND PAINTING OF
FABRICATED MATERIALS USED ON
THE POLES AND NUMBERING WITH
COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING
ERECTION OF GUY SETS AND
DISMENTALLING OF 8 MTR PSC POLE
WITH CREDITING OF FABRICATION AT
33 9926000033 STORE & STACKING OF POLE SAFELY No.
ON ROAD SIDE OR CREDITING TO
DEPARTMENTAL STORE
DISMENTALLING OF 10 MTR PSC POLE
WITH CREDITING OF FABRICATION AT
34 9926000034 STORE & STACKING OF POLE SAFELY No.
ON ROAD SIDE OR CREDITING TO
DEPARTMENTAL STORE
DISMENTALLING OF TRANSFORMER
CENTRE (8 MTR PSC POLE) (WITH
TRANSFORMER) WITH CREDITING OF
35 9926000035 FABRICATION & TRANSFORMER AT No.
STORE & STACKING OF POLE SAFELY
ON ROAD SIDE OR CREDITING TO
DEPARTMENTAL STORE
DISMENTALLING OF TRANSFORMER
CENTRE (8 MTR PSC POLE) (WITHOUT
TRANSFORMER) WITH CREDITING OF
FABRICATION AT STORE & STACKING
OF POLE SAFELY ON ROAD SIDE OR
CREDITING TO DEPARTMENTAL STORE
File No: DGVCLDOKI/TEN/e-file/6817/2026/2939/Account
Approved By: Executive Engineer,Technical,DGVCLDOKI
Letter No: DGVCLDOKI/0303/06/2026 Approved Date: 08-06-2026
STRINGING OF LT ABC OF 1*35 SQ MM
+ 1*25 SQ MM INCLUDING FITTING OF
ALL ACESSARIES I.E. SPECIAL DESIGN
SUSPENSION / TENSION CLAMP,
FIXING OF CROSS ARM, LT SHACKLE
INSULATOR ETC. FOR FIXING OF
MESSENGER WIRE AND TO PROVIDE
SERVICE CONNECTION ON AERIAL
BUNCH CABLE BY INSULATED
PIERCEING CONNECTORS THROUGH
SERVICE CONNECTION BOX
COMPLETE AS REQUIRED & DIRECTED
BY ENGINEER IN CHARGE.
STRINGING OF LT ABC OF 3*50 SQ MM
+1*25 SQ MM+1*35 SQ MM INCLUDING
FITTING OF ALL ACESSARIES I.E.
SPECIAL DESIGN SUSPENSION /
TENSION CLAMP, FIXING OF CROSS
ARM, LT SHACKLE INSULATOR ETC.
38 9926000038 FOR FIXING OF MESSENGER WIRE KM
AND TO PROVIDE SERVICE
CONNECTION ON AERIAL BUNCH
CABLE BY INSULATED PIERCEING
CONNECTORS THROUGH SERVICE
CONNECTION BOX COMPLETE AS
REQUIRED & DIRECTED BY ENGINEER
STRINGING OF 11KV ABC OF 3*95 SQ
MM +80 SQ MM INCLUDING FITTING
OF ALL ACESSARIES I.E. SPECIAL
DESIGN SUSPENSION / TENSION
39 9926000039 CLAMP, FIXING OF CROSS ARM, KM
INSULATOR,PREPARING SHACKLE
POINT,JUMPERS ETC. AS REQUIRED &
DIRECTED BY ENGINEER IN CHARGE
STRINGING OF 22 KV ABC OF 3*70 SQ
MM +95 SQ MM INCLUDING FITTING
OF ALL ACESSARIES I.E. SPECIAL
DESIGN SUSPENSION / TENSION
CLAMP, FIXING OF CROSS ARM,
40 9926000040 BINDING TO PIN KM
INSULATOR,PREPARING SHACKLE
POINT,JUMPERS ETC. AS REQUIRED
AND DIRECTED BY ENGINEER IN
File No: DGVCLDOKI/TEN/e-file/6817/2026/2939/Account
Approved By: Executive Engineer,Technical,DGVCLDOKI
Letter No: DGVCLDOKI/0303/06/2026 Approved Date: 08-06-2026
STRINGING OF LT ABC OF 2*50 SQ MM
+1*25 SQ MM+ 35 SQ MM INCLUDING
FITTING OF ALL ACESSARIES I.E.
SPECIAL DESIGN SUSPENSION /
TENSION CLAMP, FIXING OF CROSS
ARM, LT SHACKLE INSULATOR ETC.
FOR FIXING OF MESSENGER WIRE
AND TO PROVIDE SERVICE
CONNECTION ON AERIAL BUNCH
CABLE BY INSULATED PIERCEING
CONNECTORS THROUGH SERVICE
CONNECTION BOX COMPLETE AS
REQUIRED & DIRECTED BY ENGINEER
DISMENTALING OF RSJ (9/11 METER)
42 9926000042 POLE AND CREDITING THE OLD No.
MATERIAL TO STORE
DISMENTALING OF TRANSFORMER
CENTER ON 10MTR,270KG PSC
POLE(WITHOUT TRANSFORMER) WITH
43 9926000043 CREDITING OF FABRICATION AT No.
STORE AND STACKING OF POLE
SAFELY ON ROAD SIDE OR CREDITING
TO DEPARTMENTAL STORE
DISMENTALING OF TRANSFORMER
CENTER ON 10MTR,270KG PSC
POLE(WITH TRANSFORMER) WITH
44 9926000044 CREDITING OF FABRICATION AT No.
STORE AND STACKING OF POLE
SAFELY ON ROAD SIDE OR CREDITING
TO DEPARTMENTAL STORE
DISMENTLING OF 11KV ABC OF 3*95
SQ MM +80 SQ MM AND CREDITING
45 9926000045 FITTING OF ALL ACESSARIES AND KM
FABRICATION TO DEPARTMENTAL
DISMENTLING OF 22 KV ABC OF 3*70
SQ MM +95 SQ MM AND CREDITING
46 9926000046 FITTING OF ALL ACESSARIES AND KM
FABRICATION TO DEPARTMENTAL
DISMENTALING OF LT ABC OF 1*35 SQ
47 9926000047 MM + 1*25 SQ MM AND CREDITING KM
FITTING OF ALL ACESSARIES TO
DEPARTMENTAL STORE.
DISMENTALING OF LT ABC OF 3*50 SQ
MM +1*25 SQ MM+1*35 SQ MM AND
CREDITING FITTING OF ALL
ACESSARIES TO DEPARTMENTAL
File No: DGVCLDOKI/TEN/e-file/6817/2026/2939/Account
Approved By: Executive Engineer,Technical,DGVCLDOKI
Letter No: DGVCLDOKI/0303/06/2026 Approved Date: 08-06-2026
DISMENTALING OF LT ABC OF 2*50 SQ
MM +1*25 SQ MM+ 35 SQ MM AND
CREDITING FITTING OF ALL
ACESSARIES TO DEPARTMENTAL
RESTRINGING OF ALL TYPE OF
CONDUCTOR (EXCEPT DOG
50 9926000050 CONDUCTOR) FOR 11/22KV & LT LINES
INCLUDING FIXING OF INSULATORS,
BINDING JUMPERING ETC.
RESTRINGING OF DOG CONDUCTOR
51 9926000051 FOR 11/22KV HT LINES INCLUDING ,
BINDING JUMPERING ETC.
LABOUR CHARGE FOR THE
52 9926000052 INSTALLATION OF NEW DTR METER. No.
(METER WILL BE PROVIDED BY DGVCL)
LABOUR CHARGE FOR THE
REPLACEMENT OF DTR METER AND
53 9926000053 OLD METER SHOULD BE CREDITED TO No.
SDN STORE. (METER WILL BE
PROVIDED BY DGVCL)
LABOUR CHARGE FOR PROVIDING CT
COIL FOR DTR METER CONNECTION.
(CT COIL WILL BE PROVIDED BY
LABOUR CHARGE FOR REPLACEMENT
OF CT COIL FOR DTR METER
55 9926000055 CONNECTION AND OLD CT SHOULD BE PER CT
CREDITED TO SDN STORE. (CT COIL
WILL BE PROVIDED BY DGVCL)
LABOUR CHARGE FOR FIXING OF MMB
56 9926000056 FOR DTR METER (MMB WILL BE No.
PROVIDED BY DGVCL)
LABOUR CHARGE FOR REPLACEMENT
57 9926000057 OF DTR METER BOX. (METER WILL No.
BE PROVIDED BY DGVCL)
PROVIDING / REPLACEMENT OF 1.5 SQ
MM 10 CORE COPPER CABLE
METER (CABLE TO BE PROVIDED BY
LABOUR CHARGE FOR
PROVIDING/RECONNECTION OF
59 9926000059 TERMINAL CONNECTION WITH
PROPER SIZE OF LUGS. (LUGS COST IS
BORNE BY AGENCY)
File No: DGVCLDOKI/TEN/e-file/6817/2026/2939/Account
Approved By: Executive Engineer,Technical,DGVCLDOKI
Letter No: DGVCLDOKI/0303/06/2026 Approved Date: 08-06-2026
LABOUR CHARGE FOR THE SPOT
READING OF DTR METER WITH DETAIL
SURVEY OF DEFECT IF ANY. A DULY
SIGN COPY BY SURVEYOR PERSON OF
AGENCY IN PRO-FORMA REPORT
60 9926000060 SHOULD BE SUBMITTED TO SDN PER DTR
OFFICE.(* ONLY IF ALL PARAMETER OF
VOLTAGE, CURRENT & LOAD AS
SHOWN IN PER-FORMA IS FILLED) AS
PER THE INSTRUCTION OF ENGINEER
LABOUR CHARGE FOR THE SPOT
READING OF DTR METER WITH DETAIL
SURVEY OF DEFECT IF ANY. A DULY
SIGN COPY BY SURVEYOR PERSON OF
61 9926000061 AGENCY IN PRO-FORMA REPORT PER DTR
SHOULD BE SUBMITTED TO SDN
OFFICE. (DULY FILL PER-FORMA IN
FAULT CONDITION IN WHICH READING
PARAMETER IS NOT SHOWN IN METER)
INSTALLATION OF DTR METER
INCLUDING METER BOX, PROVIDING &
FIXING OF 1.5SQ MM SINGLE STRAND
10 CORE ARMOURED COPPER CABLE
(3.5METER), TERMINATION IN METER &
COIL ETC.(METER, METER BOX,
C.T./P.T. COIL WILL BE PROVIDED BY
INSTALLATION OF DTR METER
INCLUDING METER BOX, TERMINATION
IN METER & COIL ETC. (WITHOUT
10CORE COPPER CABLE) (METER,
METER BOX, C.T./P.T. COIL WILL BE
PROVIDED BY DGVCL)
Binding of messanger Conductorat with a
distance not more than 0.75 mtr with
64 9926000064 turns minimum on XLPE Cable with single No
strand binding wire (including cost of
Supply and Installation of 11/22 kV
Distribution Transformers HT Terminal
65 9926000086 protector (UV Resistance) with using PER SET
95/120/150 sq.mm long barrel aluminum
lug. (1Set = 3 Nos i.e. on R, Y, B)
Supply & Installation of HT EPR Tap on
11/22 kV Distribution Transformer with
replacement of bare conductor by HT ABC
66 9926000087 conductor (DO bottom side to transformer) PER SET
after removal of semi conductor by HT ABC
(6 inch both side). HT ABC to be supplied
by DGVCL. (1Set = 3 Nos i.e. on R, Y, B)
File No: DGVCLDOKI/TEN/e-file/6817/2026/2939/Account
Approved By: Executive Engineer,Technical,DGVCLDOKI
Letter No: DGVCLDOKI/0303/06/2026 Approved Date: 08-06-2026
Supply, Installation, Testing and
Commissioning of Maintenance Free,
Ready Capsule, Pipe-In-Cage (Pic) Type,
67 9926000088 Earth Electrodes for HT Feeder Pole NO
Having 2000 mm Electrode Length as per
the Tender Specifications and Drawing. (All
Materials Will Be Supplied By Agency)
Supply, Installation, Testing and
Commissioning of Maintenance Free,
Ready Capsule, Pipe-In-Cage (Pic) Type,
68 9926000089 Earth Electrodes for HT Feeder Pole NO
Having 3000 mm Electrode Length as per
the Tender Specifications And Drawing. (All
Materials Will Be Supplied By Agency)
Supply and Installation of 25 X 3 mm GI
Strip having hot dip- galvanized-zinc
coating of 80-100 microns without any
joints or welding. Both the end of the GI
strip should be connected with GI nut bolts
and required fabrication work for giving
separate earthing connections to
(1) Neutral of the transformer
(2) MS structures of the transformer center
(Approximately 25 meter GI strip per
transformer centre
- as per requirement and instruction of
Engineer in- charge) (All Materials will be
supplied by Agency)
Supply and Installation of uPVC standard
make Pipe of 1.25" diameter for covering
GI strip with UV protected Cable Ties of
550 X 7.6 mm size to bind with pole
face(Approximately 25 meter uPVC pipe for
GI strip covering per transformer centre -as
per requirement and instruction of Engineer
Supply & fixing of upto 33 kV Conductor
sleeve for Busbar to Drop out Fuse and
Drop out fuse to Transformer H.T. including
Busbar (12 mm sleeve) as per technical
specification. (All Materials will be supplied
Supply & fixing of upto 33 kV Conductor
sleeve for Busbar to Drop out Fuse and
Drop out fuse to Transformer H.T. without
Busbar (12 mm sleeve) as per technical
specification. (All Materials will be supplied
File No: DGVCLDOKI/TEN/e-file/6817/2026/2939/Account
Approved By: Executive Engineer,Technical,DGVCLDOKI
Letter No: DGVCLDOKI/0303/06/2026 Approved Date: 08-06-2026
Supply & fixing of upto 33 kV Conducotr
sleev for Busbar to Drop out Fuse and Drop
out fuse to Transformer H.T. including
73 9926000094 Busbar(15 mm sleev) as per technical Per TC
specification. (All Materials will be supplied
Supply & fixing of upto 33 kV Conductor
sleeve for Busbar to Drop out Fuse and
Drop out fuse to Transformer H.T. without
Busbar (15 mm sleeve) as per technical
specification. (All Materials will be supplied
Supply & fixing of Disc type Red Color
FRP(Non-flammable) material with
Weather resistant, Non-conductive bird
guard OD=300 MM, ID=33 MM, Width
=1.25 MM, one side cut from ID to OD. (All
Materials will be supplied by Agency)
Providing and fixing of LT Terminal
protectors i.e. Re-useable boot (LT Side
76 9926000096 1.1 kV) including LT (1.1 kV) insulating No
taps. All live part at LT side shall be
covered with fixing of LT insulating taps.
77 Nylon Net around Transformer Center
78 9926000097 Nylon Net (12 * 15 ft) Per Net 850
79 9926000098 Nylon Dori Per TC 200
Labour charge for fitting Nylon Net (All
80 9926000099 fabricated material for fitting nylon net shall Per TC
be provided by DGVCL)
Providing transformer Plinth of various
transformer centres by providing and fixing
RCC block in C.C. (1:2:4) in block of size
0.60M X 0.30M X 0.15M including Carting
the block at various transformer centre,
lifting the transformer from plinth by block
masonry in C.N. )1:6), placing transformer
in the position of the rising plinth with all
cost of material say cement, sand, centring
etc. labor and curing the block etc.
completely as per instruction of engineer in
(A) LINE MAINTENANCE
Cutting of Tree branches surounding HT/LT
1 9924000001 Per Tree
Replacement of old jumpers & providing
2 9924000002 new double jumpers with 8" binding [D No.
Type] & capsuling with PVC pipe etc
3 9924000005 Support pole for Stay PSC/STP/RSJ No. 633
Pin binding of conductor 11/22kv Pin
Pin binding of conductor 11/22kv Pin
5 9924000007 insulator per pole in costle area with No.
File No: DGVCLDOKI/TEN/e-file/6817/2026/2939/Account
Approved By: Executive Engineer,Technical,DGVCLDOKI
Letter No: DGVCLDOKI/0303/06/2026 Approved Date: 08-06-2026
Pin binding of conductor LT shakel
Replacement of one/both disc.insulator at
Replacement of LT shackle insulator at cut
9 9924000011 Refixing of V cross Arm No. 61
Replacement of V cross Arm (With
Transportation & Painting)
119924000013 Refixing of Top fitting in proper position No. 41
129924000014 Replacement of Top fitting No. 51
139924000015 Replacement of LT cross Arm No. 105
Providing DO fuse on DP with carting &
jumpuring(ONE DO FUSE)
Numburing of pole with paint by preparing
back ground of one colour and have
lettering(height 3" * width 0.5") using
169924000018 Fixing of MMB(1PH.) at consumer end No. 86
179924000019 Fixing of MMB(3PH.) at consumer end No. 128
Replacement of (1ph.) meter for Urban
199924000021 Replacement of (1ph.) meter for Rural area No. 74
painting consumer no. on MMB (Urban)
(with letter size height 40mm* width 8mm)
painting consumer no. on MMB (Rural)
(with letter size height 40mm* width 8mm)
Replacement of deteriorated Single phase
Fixing of new dist. Box with complete wiring
including clamps,nut bolts etc.
Reparing of guarding involving reshaping of
bearer wire cross lacing binding etc.
Painting of steel fabricated material of RSJ
DO DP structure with paint
Painting of steel fabricated material of RSJ
269924000028 pole mounted transformer double pole No.
structure with paint
Painting of steel fabricated material of RSJ
single pole with paint
painting of steel fabricated material of PSC
Single pole (HT line) with paint
painting of steel fabricated material of PSC
DO DP double pole with paint
painting of steel fabricated material of PSC
309924000032 double pole at pole mounted transformer No.
319924000033 Providing line seperater single phase No. 11
329924000034 Providing line seperater three phase No. 31
Replacement / Providing of stay insulator
339924000035 along with adjustment of tension in stay No.
File No: DGVCLDOKI/TEN/e-file/6817/2026/2939/Account
Approved By: Executive Engineer,Technical,DGVCLDOKI
Letter No: DGVCLDOKI/0303/06/2026 Approved Date: 08-06-2026
Replacement of deteriorated /providing
349924000036 LT dist. Box with new up to 100KVA No.
capacity & crediting it to store.
Replacement of deteriorated /providing
359924000037 LT dist. Box with new above 100KVA No.
capacity & crediting it to store.
369924000038 Adjustment of tension in stay wire No. 158
379924000039 Refitting of LA No. 31
Converting pin point to Shackle point
389924000040 location
including dismentaling & restringing etc.
replacement of 11KV Pin insulator with
providing new double pin binding
replacement of 22KV Pin insulator by new
409924000042 11kv pin insulator with spares & providing No.
new double pin binding
Providing 11kv double disc insulators with
binding & restringing
Replacement of existing 11kv conductor
429924000045 Cond/KM
(all size) with new double pin binding
Plumbing of PSC Pole with straightening at
Plumbing of PSC Pole with straightening at
Plumbing of tilted DP structure
459924000048 (PSC/RSJ/STP) with refilling of stone No.
Providing new 11kv AB /GO switch with
469924000049 fabrication and insulated colour code Set
jumper, binding, lugs etc
Replacement of old 11kv AB /GO switch
479924000051 with providing new insulated jumper, Set
binding, lugs etc
Providing cage type loop guard in verticle
489924000052 per pole
LT line with using PVC reel insulators etc
Labour charges for replacement /providing
499924000053 of MMB & service with all accessories for No.
three phase connection
Labour charges for replacement /providing
509924000054 of MMB & service with all accessories for No.
single phase connection
Dismentalling of existing Dist.X'mer
center(RSJ /STP POLE) 25/63/100/200
KVA with all fabrication & creditig the old
material to store
52 9924000056 Disconnection from LT pole 1 phase No.
Reconnection from LT pole 1 phase
( payment after receipt of R/C charges)
54 9924000058 Disconnection from LT pole 3 phase No.
Reconnection from LT pole 3 phase
( payment after receipt of R/C charges)
Dismentaling & removing of service line
from pole & crediting to S/dn (1 ph.)
File No: DGVCLDOKI/TEN/e-file/6817/2026/2939/Account
Approved By: Executive Engineer,Technical,DGVCLDOKI
Letter No: DGVCLDOKI/0303/06/2026 Approved Date: 08-06-2026
Dismentaling & removing of service line
from pole & crediting to S/dn (3 ph.)
Reconnection of service line complete with
PVC cable (1 Ph)
Reconnection of service line complete with
PVC cable (3 Ph)
Providing spiral type earthing by G.I. NO
8(weight 2kg -5mtr in length) with salt and
coal 10kg each, including pvc rigid pipe
60 9924000064 20mm dia( 1.5mtr length) to pass exposed No.
part of G.I. wire at consumer end with all
materials, earth resistance should be less
Providing and fixing of signle core 1.5 sq
mm single strand copper insulated cable
with cable nail clip for spiral type earthing
at consumer end. The end of G.I. no 8 is to
be connected by connector with copper
61 9924000070 cable of which other end shall be per meter
connected to the earth terminal of meter
box. This item shall be used in location
where there is more distance between
earth terminal and earthing terminal of
meter. (All materials supplied by contractor)
GPS Mapping survey of Existing Consumer
through GPS mapping application. (Only
62 Mahanagarpalika / Nagarpalika Area) (. no
(Excluding Apartment/ Complex
GPS Mapping survey of Existing Consumer
through GPS mapping application.
63 (Excluding Mahanagarpalika / Nagarpalika no
Area) . (Excluding Apartment/ Complex
DISMENTALING OF ALL TYPE OF
CONDUCTOR FOR 11/22KV & LT LINES
INCLUDING FIXING OF INSULATORS,
BINDING JUMPERING ETC.
Stringing of LT ABC of 1*35 SQ MM +
1*25 SQ MM including fitting of all
acessaries i.e. special design suspension /
tension clamp, fixing of cross arm, LT
shackle insulator etc. for fixing of
messenger wire and inclusive of
65 9924000065 dismantling charge of existing bare 65
conductor and crediting in to store &
dismentaling of service line from LT bare
conductor and to provide service
connection on Aerial Bunch Cable by
insulated pierceing connectors through
service connection box complete as
required & directed by Engineer in Charge.
File No: DGVCLDOKI/TEN/e-file/6817/2026/2939/Account
Approved By: Executive Engineer,Technical,DGVCLDOKI
Letter No: DGVCLDOKI/0303/06/2026 Approved Date: 08-06-2026
Stringing of LT ABC of 3*50 SQ MM +1*25
SQ MM+1*35 SQ MM including fitting of all
acessaries i.e. special design suspension /
tension clamp, fixing of cross arm, LT
shackle insulator etc. for fixing of
messenger wire and inclusive of
66 9924000066 dismantling charge of existing bare KM
conductor and crediting in to store &
dismentaling of service line from LT bare
conductor and to provide service
connection on Aerial Bunch Cable by
insulated pierceing connectors through
service connection box complete as
required & directed by Engineer in Charge.
Stringing of 11KV ABC of 3*95 SQ MM +80
SQ MM including fitting of all acessaries
i.e. special design suspension / tension
clamp, fixing of cross arm, binding to pin
67 9924000067 insulator,preparing shackle point,jumpers KM
etc. and inclusive of dismantling charge of
existing bare conductor and crediting in to
store complete as required & directed by
Engineer in Charge
Stringing of 22 KV ABC OF 3*70 SQ MM
+95 SQ MM including fitting of all
acessaries i.e. special design suspension /
tension clamp, fixing of cross arm, binding
to pin insulator,preparing shackle
point,jumpers etc. and inclusive of
dismantling charge of existing bare
conductor and crediting in to store
complete as required & directed by
Engineer in Charge
Stringing of LT ABC of 2*50 SQ MM +1*25
SQ MM+ 35 SQ MM including fitting of all
acessaries i.e. special design suspension /
tension clamp, fixing of cross arm, LT
shackle insulator etc. for fixing of
messenger wire and inclusive of
dismantling charge of existing bare
conductor and crediting in to store &
dismentaling of service line from LT bare
conductor and to provide service
connection on Aerial Bunch Cable by
insulated pierceing connectors through
service connection box complete as
required & directed by Engineer in Charge.
Laying,Testing & commissioning of
Specially designed 11 KV 55mm2 AAAC
70 9601000812 Medium Voltage Covered conductor as per KM
the technical specifications (with
File No: DGVCLDOKI/TEN/e-file/6817/2026/2939/Account
Approved By: Executive Engineer,Technical,DGVCLDOKI
Letter No: DGVCLDOKI/0303/06/2026 Approved Date: 08-06-2026
Labour charges for Lying of O/H XLPE
cable pole to pole
Supply & fixing of heat shrink type end
terminations (outdoor) for upto 11kV 3C x
185 mm2 size XLPE cable as per DGVCL
technical specification
Supply & fixing of heat shrink type end
terminations (indoor) for upto 11kV 3C x
185 mm2 size XLPE cable as per DGVCL
technical specification)
Providing and fixing of pipe type earthing
from 80 mm dia class-B GI pipe with pit to
be filled with salt & coke and construction
of chamber as per DGVCL Drg. No. dg
74 9925000016 /100 for DP and cable. The earthing pit No.
should be joined with cable by G.I. strip of
size 1” width & 2 mm thick. All material GI
pipe, Coke, Salt etc will be supplied by
Testing of cable at various points and
commissioning the feeder as per
75 9925000025 instruction of engineer-in-charge. Test No.
result shall be submitted by contractor with
Laying,Testing & commissioning
of Specially designed 11 KV AL-
76 59 ACS Medium Voltage Covered KM
conductor as per the technical
specifications (with accessories)
Laying,Testing & commissioning
of Specially designed 11 KV
55mm2 AAAC Medium Voltage
Covered conductor as per the
technical specifications (with
Providing and fixing Green HDPE
pipe ,size 160 mm Dia X 5 mm
thickness X 7 feet height . & GI
clamp size 25 X 3 mm (1 Round
clamp & 2 Nos C -type Clamp with NO
GI bolts – nuts (10 nos.) Danger
sign sticker with toll free number
of DGVCL embossed
File No: DGVCLDOKI/TEN/e-file/6817/2026/2939/Account
Approved By: Executive Engineer,Technical,DGVCLDOKI
Letter No: DGVCLDOKI/0303/06/2026 Approved Date: 08-06-2026
Model:ETP/HDR/17/2
Terminal Size: 25mmX 6mm
With clamp & 2 no’sof M10 size
SS nut & terminal to T/C neutral
using Bolts with connection of
earthling 25X 3mm Hot Dip GI
Transformer/ Earthling 04 Mtr GI
patti)Installation of Earthling PIT
includes supply and
labour for connectionall respect.
Dismental OF 100MM2
AAAC/MVCC CONDUCTOR
Supply and fixing of Suspenssion
clamp to Hold the cable (J-Hook)
TOTAL ESTIMATED AMOUNT OF
Total Amount of Work
Total Amount of Work
Note :- All Rates are
Excluding of GST.
File No: DGVCLDOKI/TEN/e-file/6817/2026/2939/Account
Approved By: Executive Engineer,Technical,DGVCLDOKI
Letter No: DGVCLDOKI/0303/06/2026 Approved Date: 08-06-2026
1. DGVCL will provide key material like M.S.
materials,ABC/Bare conductors,PSC/RSJ
Poles,Insulators,Fabricated materials etc. to the contractor.
2.All fabricated items shall be fabricated as per DGVCL
approved drawing and by welding rods confirming to the
relevent ISI specification and as directed by Engineer in
3.Necessary electricity connection for fabrictated items
shall be provided by DGVCL on payment of required charge
for connection & electricity bill of the same shall be paid by
4.All the rates are inclusive of PF and Exclusive of GST
applicable time to time.
5.All steel material are to be painted as below: Executive Engineer
(a) Scrubbing of rusted surface properly before applying DGVCL
the paints on to the RSJ poles & steel fabricated materials Kim Ind Division
of RSJ/PSC poles is must required.
(b) Two coats of approved ISI mark red oxide (primer) is to
be properly painted for the RSJ poles & steel fabricated
materials of RSJ/PSC poles.
(c) Two coats of approved ISI mark silver paint (i.e. triple
mangoes or equivalent quality silver paint) is to be properly
painted on to the RSJ poles & steel fabricated materials of
6. Qualified bidder has to work of TC HT booting, sleeve for
Busbar to Drop out fuse to Transformer H.T, Raising of
Plinth and maintenance of Overhead line under jurisdiction.
File No: DGVCLDOKI/TEN/e-file/6817/2026/2939/Account
Approved By: Executive Engineer,Technical,DGVCLDOKI
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
2.1 Tender Notice 26-27-01-10.pdf
2.2 N-procure.pdf
2.3 Technical Specification.pdf
2.4 Bid Document terms and condition.pdf
2.5 Schedule B 26-27-01-10.pdf
Download all tender documents and submit your bid