Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹65.2 LAccepted-AOC 11TH FLOOR ECO CENTRE BUSINESS TOWER P NO 4 EM BLOCK SECTOR V KOLKATA 91 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹82.7 L+₹17.5 L (26.9%)Rejected-Finance 4TH FLOOR VOLTAS HOUSE A BLOCK DR BABASAHEB AMBEDKAR ROAD CHINCHPOKLI MUMBAI MAHARASHTRA 400033 | MUMBAI | MAHARASHTRA | 400033 | L2 | Rejected-Finance Highest bid | |
| 3 | Rejected-Technical | - | Rejected-Technical Not meeting NIT conditions | |
| 4 | Rejected-Technical | - | Rejected-Technical Not meeting NIT conditions | |
| 5 | Rejected-Technical | - | Rejected-Technical Not meeting NIT conditions |
Tender Value
Refer Docs
EMD Value
₹1.5 L
Closing Date
11 Jan 2021, 6:00 pmClosed
AGM (E-E) , AAI , Calicut Intl. Airport
AGM (E-E) , AAI , Calicut Intl. Airport
Provision of UVGI for Centralized Air conditioning System at Calicut International Airport
2020_AAI_64452_1
AAI/CL/ENGG(E)/89/NIT-09/2020
Open Tender
Electrical Works
Works
120 days
Calicut International Airport
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,120
₹1.5 L
2 Nov 2021
16 Dec 2020
14 Jan 2021
17 Dec 2020
11 Jan 2021
17 Dec 2020
17 Dec 2020 - 8 Jan 2021
Amount
SITC of UVGI lamp system suitable for continuous operation having UV-C band having wavelength of 254+/-1nm and irradiation intensity of min 4016microwatts/sq.cm for germicidal irradiation of the entire AHU cooling coil face area along with all supporting structures, power and control panel, cabling ,earthing ,safety provisions etc as per the detailed technical specifications for AHU details specified hereunder complete as required. 1.A) 7000CFM
SITC of UVGI lamp system suitable for continuous operation having UV-C band having wavelength of 254+/-1nm and irradiation intensity of min 4016microwatts/sq.cm for germicidal irradiation of the entire AHU cooling coil face area along with all supporting structures, power and control panel, cabling ,earthing ,safety provisions etc as per the detailed technical specifications for AHU details specified hereunder complete as required. 1.B) 10000CFM
SITC of UVGI lamp system suitable for continuous operation having UV-C band having wavelength of 254+/-1nm and irradiation intensity of min 4016microwatts/sq.cm for germicidal irradiation of the entire AHU cooling coil face area along with all supporting structures, power and control panel, cabling ,earthing ,safety provisions etc as per the detailed technical specifications for AHU details specified hereunder complete as required. 1.C) 11000CFM
SITC of UVGI lamp system suitable for continuous operation having UV-C band having wavelength of 254+/-1nm and irradiation intensity of min 4016microwatts/sq.cm for germicidal irradiation of the entire AHU cooling coil face area along with all supporting structures, power and control panel, cabling ,earthing ,safety provisions etc as per the detailed technical specifications for AHU details specified hereunder complete as required. 1. D) 12000CFM
SITC of UVGI lamp system suitable for continuous operation having UV-C band having wavelength of 254+/-1nm and irradiation intensity of min 4016microwatts/sq.cm for germicidal irradiation of the entire AHU cooling coil face area along with all supporting structures, power and control panel, cabling ,earthing ,safety provisions etc as per the detailed technical specifications for AHU details specified hereunder complete as required. 1.E) 14000CFM
SITC of UVGI lamp system suitable for continuous operation having UV-C band having wavelength of 254+/-1nm and irradiation intensity of min 4016microwatts/sq.cm for germicidal irradiation of the entire AHU cooling coil face area along with all supporting structures, power and control panel, cabling ,earthing ,safety provisions etc as per the detailed technical specifications for AHU details specified hereunder complete as required. 1.F) 17000CFM
SITC of UVGI lamp system suitable for continuous operation having UV-C band having wavelength of 254+/-1nm and irradiation intensity of min 4016microwatts/sq.cm for germicidal irradiation of the entire AHU cooling coil face area along with all supporting structures, power and control panel, cabling ,earthing ,safety provisions etc as per the detailed technical specifications for AHU details specified hereunder complete as required. 1.G) 18000CFM
SITC of UVGI lamp system suitable for continuous operation having UV-C band having wavelength of 254+/-1nm and irradiation intensity of min 4016microwatts/sq.cm for germicidal irradiation of the entire AHU cooling coil face area along with all supporting structures, power and control panel, cabling ,earthing ,safety provisions etc as per the detailed technical specifications for AHU details specified hereunder complete as required. 1.H) 19000CFM
SITC of UVGI lamp system suitable for continuous operation having UV-C band having wavelength of 254+/-1nm and irradiation intensity of min 4016microwatts/sq.cm for germicidal irradiation of the entire AHU cooling coil face area along with all supporting structures, power and control panel, cabling ,earthing ,safety provisions etc as per the detailed technical specifications for AHU details specified hereunder complete as required. 1.I ) 20000CFM
SITC of UVGI lamp system suitable for continuous operation having UV-C band having wavelength of 254+/-1nm and irradiation intensity of min 4016microwatts/sq.cm for germicidal irradiation of the entire AHU cooling coil face area along with all supporting structures, power and control panel, cabling ,earthing ,safety provisions etc as per the detailed technical specifications for AHU details specified hereunder complete as required. 1.J) 21000CFM
SITC of UVGI lamp system suitable for continuous operation having UV-C band having wavelength of 254+/-1nm and irradiation intensity of min 4016microwatts/sq.cm for germicidal irradiation of the entire AHU cooling coil face area along with all supporting structures, power and control panel, cabling ,earthing ,safety provisions etc as per the detailed technical specifications for AHU details specified hereunder complete as required. 1.K) 23000CFM
SITC of UVGI lamp system suitable for continuous operation having UV-C band having wavelength of 254+/-1nm and irradiation intensity of min 4016microwatts/sq.cm for germicidal irradiation of the entire AHU cooling coil face area along with all supporting structures, power and control panel, cabling ,earthing ,safety provisions etc as per the detailed technical specifications for AHU details specified hereunder complete as required. 1.L) AHU 24000CFM
Comprehensive Maintenance of the UVGI system (of 56 AHUs as listed in SH 1 ) after defects liability period of one year including replacement of UVC lamps, consumables etc complete as required including performance evaluation of UVGI system by conducting suitable periodical testing at site / lab and submission of report. 2. A) First Year (After Defects Liability period)
Comprehensive Maintenance of the UVGI system (of 56 AHUs as listed in SH 1 ) after defects liability period of one year including replacement of UVC lamps, consumables etc complete as required including performance evaluation of UVGI system by conducting suitable periodical testing at site / lab and submission of report. 2. B) Second Year (After Defects Liability period)
Comprehensive Maintenance of the UVGI system (of 56 AHUs as listed in SH 1 ) after defects liability period of one year including replacement of UVC lamps, consumables etc complete as required including performance evaluation of UVGI system by conducting suitable periodical testing at site / lab and submission of report. 2.C) Third Year (After Defects Liability period)
Comprehensive Maintenance of the UVGI system (of 56 AHUs as listed in SH 1 ) after defects liability period of one year including replacement of UVC lamps, consumables etc complete as required including performance evaluation of UVGI system by conducting suitable periodical testing at site / lab and submission of report. 2.D) Fourth Year (After Defects Liability period)
Comprehensive Maintenance of the UVGI system (of 56 AHUs as listed in SH 1 ) after defects liability period of one year including replacement of UVC lamps, consumables etc complete as required including performance evaluation of UVGI system by conducting suitable periodical testing at site / lab and submission of report. 2.E) Fifth Year (After Defects Liability period)
Voltas Limited
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .