| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹64,328.02Accepted-AOC | ₹64,328.02 Quoted ₹64,328 | L1 | Accepted-AOC L1 accepted |
| 2 | Rejected-Technical KADAVATH PUVANITHI VEEDU B P ANGADI TIRUR 676102 | TIRUR | MALAPPURAM | KERALA | 676102 | - | - | Rejected-Technical L1 ACCEPTED |
| Sl No | Description | Qty | Unit | MUNEER M L1 | KP ABDUL RASHEED L2 |
|---|---|---|---|---|---|
| 1.00Electrical | |||||
| 1.00 | 1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group C | 22 | point | 1,094 ₹24,068 | 1,408.82 ₹30,994.04 |
| 1.00 | 1.14.1:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire | 35 | metre | 234.14 ₹8,194.90 | 223.84 ₹7,834.40 |
| 1.00 | 1.14.3:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire | 20 | metre | 335.82 ₹6,716.40 | 320.97 ₹6,419.40 |
| 1.00 | 1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm | 12 | metre | 95.57 ₹1,146.84 | 91.35 ₹1,096.20 |
| 1.00 | OD267348/2025-2026:Supply, installation testing and commissioning exhaust fan of size 150mm sweep Light duty in plastic body with self opening lowers in the existing opening, fixing necessary anchor bolts/bolt and nut with 0.3m,110mm PVC pipe neatly plastered in the existing exhaust fan hole, making good the damages, color washing etc as required and giving connection with required length of 24/0.20mm PVC insulted and PVC Sheathed 650/1100V grade 3 core round copper conductor flexible wire | 9 | each | 1,265.96 ₹11,393.64 | 1,209.98 ₹10,889.82 |
| 1.01 | 90.4.8:Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required. | 9 | each | 468.29 ₹4,214.61 | 447.58 ₹4,028.22 |
| 1.01 | 1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required. | 13 | each | 110.31 ₹1,434.03 | 105.44 ₹1,370.72 |
| 1.01 | OD267347/2025-2026:Supply and fixing of 9W LED Bulb, as required | 13 | each | 153.63 ₹1,997.19 | 146.86 ₹1,909.18 |
| 1.01 | 1.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. | 9 | each | 87.08 ₹783.72 | 83.24 ₹749.16 |
Tender Value
₹78,965
EMD Value
₹1,974
Closing Date
25 Oct 2025, 3:00 pmClosed
Assistant Engineer
The Assistant Engineer, LID and EW LSGD, Tirur Municipality
Retender- Annual Plan-Electrification of Toilet complex GHSS Ezhur - Tirur Municipality-Proj No - SO48/24-General Electrical Work
2025_LSGD_799204_12
06/Etender/2025-26/Item rate
Open Tender
Electrical Works
180 days
Tirur Municipality
Please refer Tender documents.
10 documents required · 10 mandatory
₹555
Yes
₹1,974
Yes
26 May 2026
16 Oct 2025
28 Oct 2025
16 Oct 2025
25 Oct 2025
16 Oct 2025
Amount
Electrical
1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
1.14.1:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
1.14.3:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
OD267348/2025-2026:Supply, installation testing and commissioning exhaust fan of size 150mm sweep Light duty in plastic body with self opening lowers in the existing opening, fixing necessary anchor bolts/bolt and nut with 0.3m,110mm PVC pipe neatly plastered in the existing exhaust fan hole, making good the damages, color washing etc as required and giving connection with required length of 24/0.20mm PVC insulted and PVC Sheathed 650/1100V grade 3 core round copper conductor flexible wire
90.4.8:Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required.
1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required.
OD267347/2025-2026:Supply and fixing of 9W LED Bulb, as required
1.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
2.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way, Double door
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
KP ABDUL RASHEED (BID ID -2409145)
Bidder Name
KP ABDUL RASHEED
MUNEER M
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1352799.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.09 MB
BOQ_1352799.xls
BOQ • 0.31 MB
fot.pdf
Tender Documents • 0.06 MB
viewsbd.pdf
Other Document • 1.63 MB
ipact.pdf
Other Document • 0.04 MB
estimate.pdf
Other Document • 0.08 MB
viewnit.pdf
Other Document • 0.02 MB
epayment.pdf
Other Document • 0.04 MB
preliminary.pdf
Additional Documents • 0.06 MB
affidavit.pdf
Other Document • 0.05 MB
Download all tender documents and submit your bid