Assistant Executive Engineer Minor Irrigation Sub
Assistant Executive Engineer Minor Irrigation Sub Division Kannur
GENERAL-Pavannur Lift Irrigation- Electrical maintenace work-General Electrical work-Urgent repair to starter-General Electrical Work
2026_Irrig_880984_1
PWD/BLDG/EST/16120/2026_6_1_1
Open Tender
Electrical Works
Item Rate
Kuttiyattur GP
Please refer Tender documents.
14 documents required · 14 mandatory
₹335
Yes
Yes
17 Oct 2026
17 Oct 2026
29 Oct 2026
17 Oct 2026
26 Oct 2026
17 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Pavannur Lift Irrigation-Urgent repair to starters-General Electrical Work | |||||
| 1.001 | OD151570/2026-2027:Dismantling the existing faulty/burnt contacts and moving parts from the L&T ML3 Power Contactor within the Star-Delta starter assembly, cleaning the arc chutes and interior housing, supplying and installing new L&T ML3 Spare Kit (Item code:SS95309), proper alignment, dressing control circuit connections, checking coil operations, testing manual and electrical trip mechanisms, and commissioning the contactor unit in full working condition as per site requirement. | 1 | each | - | - |
| 1.002 | OD151576/2026-2027:Dismantling the faulty/unresponsive single phasing preventor relay from the control panel circuit, disconnecting auxiliary control wirings, supplying and fixing a new SDZ5 380V Single Phasing Preventor Relay (Item code: XM81807OOOO) on the DIN rail channel, re-terminating control wires using insulated loop-type lugs, tracing and verifying phase sequence inputs, adjusting voltage unbalance and time delay settings as per motor specifications, simulating phase-failure and phase-reversal conditions to ensure protection triggers properly, testing, and commissioning in full working condition as per site requirement . | 1 | each | - | - |
| 1.003 | OD151582/2026-2027:Dismantling the degraded/damaged or bulged power factor correction capacitor unit from the starter base/bracket, safely discharging the residual capacitive energy, conveying the faulty unit to the designated scrap area, supplying and mounting a new L&T 10kVAR BX HD Heavy Duty Power Capacitor (HD Resin type) (Item code:LTBCH310B2) securely inside the panel or enclosure/in the existing space, re-terminating the existing connecting cables/leads with suitable copper lugs, securing insulation, tightening connections to the switching contactor, checking phase currents, measuring post-installation current draw, testing, and commissioning in full working condition as per site requirement. | 1 | each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.04 MB
sbdpav.pdf
Tender Documents • 1.63 MB
nitpa.pdf
Other Document • 0.02 MB
BOQ_1498474.xls
BOQ • 0.30 MB
SPECIFICCONDITION.pdf
Additional Documents • 0.32 MB
listofmaterials.pdf
Additional Documents • 0.19 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .