Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.7 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹23.6 L+₹1.7 L (7.92%)Rejected-Finance VILLAGE DHAR P O DASHERA TEH BALH REWALSAR DISTT MANDI HP 175036 | REWALSAR | MANDI | HIMACHAL PRADESH | 175036 | L2 | Rejected-Finance L2 | |
| 3 | L3₹24.2 L+₹2.2 L (10.3%)Rejected-Finance | L3 | Rejected-Finance L3 |
Tender Value
₹17.6 L
EMD Value
₹33,900
Closing Date
13 Dec 2021, 6:00 pmClosed
Executiuve Engineer
JSV Division No.1 Kullu
Laying, jointing and testing of HDPE pipe 75mm dia 2483Rmt, C O RCC main outlet chambers 15Nos and sub outlet chamber 47Nos PHASE-III
2021_HPIPH_54444_1
15905-15954
Open Tender
Civil Works
Item Rate
Katrain
Please refer Tender documents.
7 documents required · 7 mandatory
₹400
EE
₹33,900
Yes
11 May 2022
7 Dec 2021
14 Dec 2021
7 Dec 2021
13 Dec 2021
7 Dec 2021
Amount
Excavation in foundation and trenches up to all depths and in all classification of earth work such as pick work, jumper work, situated soil including bailing or pumping out water, blasting soft/ hard rock, chiseling /wedging of soft / hard rock where blasting is prohibited, in all lifts including trimming and dressing of sides, leveling of beds to correct grade including shoring, strutting, planking, timbering and dewatering wherever required. Stacking usable and unusable material /soil separately and after laying jointing and testing of pipes, returning the usable soil in 15cm layers by ramming and watering and then disposing of all surplus excavated soil/ unusable material as directed with in all leads/ lifts including restoration of un-metalled surfaces to its original conditions and including cost of diversion for traffic, night signal boards, fixing caution boards, crossing over trenches for access to houses, fencing etc. Complete in all respects within all leads and lifts as per direction of the Engineer-in-Charge.
Providing and laying in cement concrete 1:3:6 (1cement 3 sand 6 graded stone agg.40mm nominal size) and curing complete excluding cost of form work in foundation and plinth with in all leads and lifts
Providing and laying cement concrete work 1:1.5:3 (1cement :1.5 sand: 3 graded crushed stone aggregate 20 mm nominal size) and curing complete excluding cost of form work and reinforcement for reinforced concrete work with in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge. in: - Foundation and plinth
Wall ( any thickness but not less than 0.10 mtrs. Thickness) including attached pillasters buttresses, plinth and string courses etc. from top of foundation level upto floor two level.
Tor steel reinforcement for RCC work including bending, binding & placing in position complete upto floor two level i.c cost of binding wire with in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge.
Providing form work with steel plates 3.15mm thick welded with angle iron in frames 30x30x5mm so as to give a fair finish including centering ,shuttering, propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4 meters and removal of the same for-in-situ reinforced concrete and plain concrete work in all leads and lifts:- Vertical surfaces such as wall(any thickness) partitions and the like including attached pilasters, buttresses, plinth and string courses and the like -
Providing double flanged cast iron Sluice valve of 100 dia Leader/Kirloskar/Pelicon make conforming to as per IS: 14846-2000 with MS flanges IS :6392-1971 with hand wheel ( and other accessories) with upto amendment as per class PN-1.00 to with standing nominal seat pressure of 10.00 Kg. /cm2 flange table-5 including welding of MS flange in two layer i/c carriage in all leads & lifts as per direction and to the entire satisfaction of Engineer in charge.
Providing hydrant including GI riser pipe (IS:1239-1990) PP ball valve pump connecting Nipple GI Tee, GI Nipple (As required in main & sub main line) and plain concrete grouting for GI Tee and Riser pipe with in all leads and lifts.
65 mm dia for 75 mm and 90 mm dia HDPE pipe
Providing and fixing anchor block and control valve arrangement with cast iron sluice valve including anchor block size 0.30X0.30X0.30 with base for sluice valve 1:2:4 concrete block with in all leads and lifts. 65 mm sluice valve for 75 mm dia HDPE pipe
Laying, jointing and testign of HDPE pipe of various dia complete in all respect with in all leads and lifts and to the entire satisfaction of Engineer-in-charge.
75 mm dia PE 80 PN 4
110 mm dia PE 80 PN 4
Laying , jointing & testing of GMS Tubes light grades ( to be levelled to grade ) in trenches including fitting with tees and other accessories , testing and commissioning complete as per the IPH Specifications within all leads and lifts as per the direction of Engineer-in-Charge. Scour pipe 100 mm dia
Chuni lal
AMAR CHAND NEGI
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .