Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.7 LAccepted-AOC H NO 963 10 STREET NO 5 DEEP NAGAR CIVIL LINES LUDHIANA 141001 PUNJAB | LUDHIANA | LUDHIANA | PUNJAB | 141001 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹6.0 L+₹25,557.45 (4.45%)Rejected-Finance | L2 | Rejected-Finance other than lowest. |
Tender Value
Refer Docs
EMD Value
₹13,720
Closing Date
1 Dec 2020, 6:00 pmClosed
GE Ludhiana
Garrison Engineer Military Engineer Services Near Jagraon Bridge PIN-141001
Special repair to Bldg No P-68 at Dholewal Mil Complex and Provn of exhaust fan in JCOs/ORs Md Accn at Baddowal under GE Ludhiana
2020_MES_389813_1
GE/LDH-48/2020-21
Open Tender
Civil Works
Item Rate
180 days
Dholewal and Badoowal under GE Ludhiana
Refer NIT and Tender Documents
9 documents required · 9 mandatory
₹500
GE Ludhiana
₹13,720
Yes
24 Dec 2020
26 Oct 2020
2 Dec 2020
26 Oct 2020
1 Dec 2020
30 Oct 2020
26 Oct 2020 - 29 Oct 2020
Amount
Sch 'A' sec-I
Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness ( below or above gd level).Complete all as specified and directed by Engineer-in-charge.
M&L, 25mm thick cement concrete type B-0, 1:2:4 (12.5mm graded agg ) as in floors finished even and fair Complete all as specified and directed by Engineer-in-charge.
M&L, 50mm thick cement concrete type B-0, 1:2:4 (12.5mm graded agg ) as in Ramp flooring, finished even and fair Complete all as specified and directed by Engineer-in-charge.
M&L, machine cut kota stone slab flooring 20 to 25mm thick bedded and jointed in cement slurry cement over screed bed 20mm thick in cm (1:6) and pointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, cutting and mirror type polishing Complete all as specified and directed by Engineer-in-charge.
-ditto- as per item herein above but in skirting/dado laid over 10mm thick cement screed in cm 1:4 Complete all as specified and directed by Engineer-in-charge.
M&L, 50mm thick PCC 1:2:4Type B-1 using 20mm crushed stone aggregate as in plinth protection and like finished even and smooth without using extra cement Complete all as specified and directed by Engineer-in-charge.
M&L, Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Gradee as approved by E-I-C laid in flooring and joints filled/broomed with fine sand Complete all as specified and directed by Engineer-in-charge.
M&L, Sand filling under floors or in foundations incl. watering and consolidation Complete all as specified and directed by Engineer-in-charge.
M&L for 75mm Thick PCC (1:3:6) type C-2 using 40 mm graded stone aggregate as in sub base of flooring etc. Complete all as specified and directed by Engineer-in-charge.
M&L for PCC 1:2:4 on Type B-0 12.5mm graded stone aggregate as cement concrete in roof kerbs or mud stops, rounded or chamfered on edges for border of interlocking tiles Complete all as specified and directed by Engineer-in-charge.
Demolition of brickwork built in cement or cement lime mortar incl all quoins, arches, pillars, etc but excl ashlar facings, dressed stonework and precast concrete articles.
M&L, brick work with sub class 'B' bricks straight or curved on plan exc 6 mtr mean radius built in cm 1:6 Complete all as specified and directed by Engineer-in-charge.
ditto all as above item herein before- but except bricks Complete all as specified and directed by Engineer-in-charge.
Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, Complete all as specified and directed by Engineer-in-charge.
Taking down cement plaster of any description on brick or concrete surfaces etc including racking out joints, hacking for key, scrubbing down with water etc. Complete all as specified and directed by Engineer-in-charge.
M&L, Glazed ceramic coloured tiles (300x450mm) x 7mm thick on vertical surfaces etc, set and jointed in neat cement slurry and pointed in white cement to match the shade of tile over 10mm thick rendering in cement mortar 1:4 Complete all as specified and directed by Engineer-in-charge.
M&L, 15mm thick rendering on brick work or concrete surfaces in cement mortar 1:6 , is to finsihed the surfaces even and fair Complete all as specified and directed by Engineer-in-charge.
M&L, three coats white wash on wall surfaces inclduing prepration of newly plastere surfaces.Complete all as specified and directed by Engineer-in-charge.
M&L for preparation of old decorated plastered or unplastered surfaces (white wash/cement base colour wash) of walls by brooming down or steel wire brushing to remove all loose dirt, dust, all loose scales of lime wash and foreign matter, scrapping, removing of nails, making good holes cracks with lime putty/plaster of pairs and applying one coat of white wash Complete all as specified and directed by Engineer-in-charge.
M&L, 15mm thick rendering on brick work or concrete surfaces in cement mortar 1:4 , is to finsihed the surfaces even and fair.Complete all as specified and directed by Engineer-in-charge.
M&L, two coats cement base paint over a coat of white wash including preparation of newly plastered surfaces.Complete all as specified and directed by Engineer-in-charge.
M&L for preparation of old decorated plastered or unplastered surfaces (white wash/cement base colour wash) of walls by brooming down or steel wire brushing to remove all loose dirt, dust, all loose scales of lime wash and foreign matter, scrapping, removing of nails, making good holes cracks with lime putty/plaster of pairs and applying one coat of cement based paint.Complete all as specified and directed by Engineer-in-charge.
M&L, 5mm thick rendering on concrete surfaces of ceiling in cement mortar 1:3 , finsihed the surfaces even and smooth without using extra cement.Complete all as specified and directed by Engineer-in-charge.
M&L, three coats white wash on ceiling undecorated surfaces including prepration of newly plastere surfaces.Complete all as specified and directed by Engineer-in-charge.
M&L for preparation of old decorated plastered or unplastered surfaces (white wash/cement base colour wash) of walls by brooming down or steel wire brushing to remove all loose dirt, dust, all loose scales of lime wash and foreign matter, scrapping, removing of nails, making good holes cracks with lime putty/plaster of pairs and applying one coat of white wash in ceiling Complete all as specified and directed by Engineer-in-charge.
Taking down chowkats or frames exc 1.5 Sqm but n.exc 4.0 Sqm with shutters (without taking off shutters from the frame).Complete all as specified and directed by Engineer-in-charge.
Taking down chowkats or frames n.exc. 1.5 Sqm (without taking off shutters from the frame).Complete all as specified and directed by Engineer-in-charge.
Taking down Shutters of any description area exc 1 Sqm but n.exc. 2 Sqm Each Complete all as specified and directed by Engineer-in-charge.
S&F, pressed steel frames,size 105x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc. Complete all as specified and directed by Engineer-in-charge.
S&F, Framed mild steel work as in doors or gates of angle or other sections with gusset plates, rails, braces etc complete drilled for fixing of steel sheeting or other covering doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings(exclusive of steel sheeting or other covering, running rails and gurders) and hanging also fastening and Complete all as specified and directed by Engineer-in-charge. (Fe-410-W(Gde E-250)Quality-A).
S&F, factory made 2nd class 35mm thick hard wood plain, framed, panelled shutters (any number of panels) with panels of 9mm thick BWP commercial ply. Complete all as specified and directed by Engineer-in-charge.
S&F in repair steel windows/ ventilator with side hung shutters incl box type hing. With glazing bars and steel peg stay. Each window shutter is to be fitted with 1 steel handle 100mm long casted out of MS Z section and two number of mild steel barrel tower bolts 150mm long on suitable size MS flat.Complete all as specified and directed by Engineer-in-charge.
S&F in repair steel windows with side hung shutters incl box type hing. Without glazing bars and steel peg stay. Each window shutter is to be fitted with 1 steel handle 100mm long casted out of MS Z section and two number of mild steel barrel tower bolts 150mm long on suitable size MS flat.Complete all as specified and directed by Engineer-in-charge.
S&F, repair mild steel Framed work such as grills, gratings, etc framed guard bars , ladders railings , frame of water tanks etc confirming to Fe 410 or Fe 310.Complete all as specified and directed by Engineer-in-charge.
M&L, two coats of synthetic enamel painting on wooden surfaces over a coat of pink primer inclding prepration of newly untreates surfaces.Complete all as specified and directed by Engineer-in-charge.
M&L two coats of synthetic enamal paint to steel surfaces of any discription over 10 cm width or girth not otherwise described incl a coat of red oxide primer after preparation Complete all as specified and directed by Engineer-in-charge.
S&F, 150mm aluminium anodised barrel tower bolts of extruded section and fixed.Complete all as specified and directed by Engineer-in-charge.
S&F, 250mm aluminium alloy anodised sliding bolts with hasp, staple and fixing clips of sheet, cast or extruded section fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed.Complete all as specified and directed by Engineer-in-charge.
S&F, 125mm aluminium handles, cast type , anodised.Complete all as specified and directed by Engineer-in-charge.
S&F, second class hardwood small fittings as in shaped door/ window stops incl all necessary labours, articles n exc 200 cucm each Complete all as specified and directed by Engineer-in-charge.
Demolition of mud in roof, any thickness, incl plastering and leaping (wheather full thickness is removed or only part there of)
Dismantling of brick tiles laid on mud mortar and jointed and pointed in any cement mortar Complete all as specified and directed by Engineer-in-charge.
M&L, 15mm thick rendering on terrace, sides of parapet in cement mortar 1:4 with water proofing compound , finished even and fair.(Note water proofing compound will be measured and paid separately under other item.
M&L, cleaning the new plastered surfaces with wire brushes, brooms etc and applying a priming coat of bitumen primer @ 0.30 ltrs/Sqm consisting of 3/4 part bitumen of grade 85/25 and 1/4 part of kerosene oil.
M&L, providing APP based polymeric membrane minimum weighing 3Kg/Sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt not less than 150 gms/Sqm ) land on after applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2Kg per Sqm by forced application Complete all as specified and directed by Engineer-in-charge.
M&L, applying a coat of industrial bitumen 85/25 at the rate of 1.2Kg per sqm with forced application above APP based polymeric membrance . Complete all as specified and directed by Engineer-in-charge.
M&L for applying a two coats of water proofing paint with Aluminium finish over coat of industrial bitumen 85/25 on roof Complete all as specified and directed by Engineer-in-charge.
Sch 'A' sec-II
Taking down carefully the point wiring (light, Fan, socket or power) complete, (incl fittings such as switches, sockets any type, ceiling roses, pandents, light fittings, etc for taking credit( credit for above items should be made as per conditions separately) and making good disturbed surface of walls floors etc. all as specified.
Taking down Ceiling fan, sealing cable end, dismantling blades from fan and keeping in safe custody for reuse at site and making good disturbed surfaces complete all as specified and as directed.
Refixing only ceiling fan and connecting up including provision sutiable of new down rod for ceiling fans,of cable from celling rose/ connector to fan all as specified and as directed.
M &L Point wiring complete with 1.5 sqmm single core PVC insulted FRLS cable 1100 volts grade multistranded copper conductor drawn through and including 20mm dia PVC rigid non metallic conduit with all accessories such as internal bend end caps etc complete concealed in walls/ceiling/roof/etc including provision of 1.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade with multistranded copper conductor cable as earth continuity conductor fabricated steel terminal box made out of MS sheet concealed in walls with 3mm thick hylem sheet cover, ISI marked with chromium plated screws and cup washers for housing the sockets outlets, fan regulator etc incl with cutting of chases for conduit and sinking of boxes all as specified, incl making good surface with exiting colour all as specified and as directed for the following :-
One light/fan point controlled by one, one way switch
One switch socket outlet point 5 Amps on independent board
One 3 Pin socket outlet , 5 Amps on the same board with other switch
All as per item No. 51 described here-in-before but with copper conductor cable FR LS 2.5 Sqmm for one 3 pin socket outlet, 15 Amps and including provision of 2.5 Sqmm PVC insulated copper conductor cable as earth continuity conductor on independent board.
Supply and fix, LED tube light fittings 1200 mm, 20W, 240V, 50Hz,rated input current- 0.070-0.110, rated input watt 20, oprating voltage range- 140-270, P.F- not less then 0.95, surge protection upto- 4Kv, IP20, THD shell be less then 10%, CCT- (k0)- 6500ANSI, higher energy saving decorative ultra slim square profile LED lighting fixture with extruded polycarbonate enviromental friendly, energy efficient complete all as specified and directed.
M&l, Sub main wiring complete with 2 runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade multistranded copper conductor cable with 1 run of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm or higher dia non metallic rigid PVC conduit and conduit accessories concealed in wall/Ceiling etc all as specified and as directed by engr - in- charge. Note : 2 runs of 6 sqmm, 1 run of 6 sqmm earth conductor and 1 run of PVC conduit shall be measured as one unit length
Supply and fix , TPN MCB DB 4 ways 415 Volt, Double door type all as specified and as directed by Engr-in-charge
S & F, MCB TPN 40 Amps, 10 KA, C series 50Hz ,415 Volts complete all as specified and as directed by Engr-in-charge
Supply and fix, SPN MCB DB 8 ways 240Volt, Double door type complete all as specified and as directed by Engr-in-charge
S & F , MCB SPN 6- 32 Amps, 10 KA , C series 50Hz, 240Volts complete all as specified and as directed by Engr-in-charge
S & F, SP MCB 6-32 Amps 10 KA , C series 50Hz ,240Volts complete all as specified and as directed by Engr-in-charge
Supply and fix, ceiling rose surface type bakelite 65 x 50mm with three terminals.
Supply and Fix, Switch Piano,Flush type single pole , one way 5 Amp complete all as specified and as directed by Engr-in-charge
Supply and Fix, Socket outlet 3 pin, 5 A flush Piano,Flush type complete all as specified and as directed by Engr-in-charge
Supply and Fix, Switch Socket combenation 2 in 1 outlet 3 pin, 5 A flush type complete all as specified and as directed by Engr-in-charge .
Supply and Fix, Switch Socket combenation 2 in 1 outlet 3 pin, 16 A flush type complete all as specified and as directed by Engr-in-charge .
S&F, fan regulator , fulsh stapped type ,electronic , 230V, AC complete all as specified and directed .
M &L, Earthing complete incl earthwork with galvanised steel earth plate electrode 60cm X 60 cm X 6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level with the top edge of electrode not less than 1.5 mtr below normal ground level connected to galvanised earth lead wire 4mm dia means of bolts, nuts,check nuts and washers of galvanised iron and GI lead protected with protection pipe of GI light grade 15mm dia upto 3mtr above ground level along poles fixed with two clamps of 25mm 3mm flat iron and connected to running earth wire at top of poles and watering pipe 20mm bore of GI medium grade all as shown in electrical plate No 3 of SSR Part-I 2009 connected to earthing test point all as specified and direct and testing on completion including PCC 1:3:6 ) C-I cover and frame excavation and earth work etc complete all as specified in elect plate No 3 of SSR Part -I 2009 Note :- PCC Chamber shall be constructed at least 1.50 mtr away from on the earth pit electrode and pipe for watering shall be provided in slanting manner.
Supply, laying and testing cable XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 sqmm 3.5 core compete all as specified and directed
Taking down of any size of bldy security light fittings complete all as specified and directed by Engineer-in charge
Supply and fixing, bldg security light fitting LED 30 W LED made up of pressure die cast aluminium housing with potted isolated driver and high power LED and indl lenses, oprating range- 90V to 340V AC. LED life -1 Lac burning hrs , fixture should with stand 320V upto 48 Hrs , auto cut off>320 V & restart ,440V sustain upto 8 Hrs, NABL acreddited LM 79 report, IP66 with high power LED lamp compete all as specified and directed.
Excavation in trenches soft/ loose soil not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of pipes/cables etc getting out and bottom surface to required gradient complete all as directed & specified
Returning filling in including spreading leveling watering and well ramming in layers each not exceeding 25 cm thickness complete all as specified and as directed .
Removal of surplus spoil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed .
M & L, Sand cushioning to UG cable with a layer of fine sand 8 Cms thick before laying of cable and 15 Cms thick after laying of cable in trenches complete all as specified. Note:-Thickness of 18cm after punning shall be considered for payment.
M & L, Old size sub class 'B' bricks,laid flat in trenches over the cable with length of brick perpendicular to the direction of the cable , adjacent/abutting each other complete all as specified
M&L for point wiring with 1.5 sqmm (nominal area) PVC insulated multi stranded copper conductor cable drawn in and including concealed rigid PVC conduit with accessories including cutting chases for laying of conduit / fixing of boxes in walls / floor etc including making good to disturbed surface as per adjoining specification and terminated in concealed terminal boxes including MS concealed terminal boxes with plastic laminated bakelite sheet top cover 3mm thick make hylum or equivalent fixed with nickel polished screws with washers , earth continuity PVC insulated cable copper conductor 1.5sqmm (nominal area) stranded as green colour as earth wire connected with earth dolly complete all as specified and directed by Engr-in-charge. (a) one fan point controlled by one switch
S&F , exhaust fan, 300mm sweep, 900 rpm , single phase ,230 volt, heavy duty , with loverred shuuter including provision of three core flexible cable of required length of size 23/0.0076 from ceiling rose / connector to fan terminal , fixing the fan on wall with suitable size of nut , bolt & washer complete all as specified and directed by Engr-in-charge. Make:- Havells/Crompton/Bajaj/ Khaitan or equivalent as approved by GE.
M&L for making opening for exhaust fan of size 300mm dia by cutting of wall of any specification including finishing surface and rendering complete in cement mortar 1:4 10mm thick including making good to all disturbed surfaces and matching the same with existing specifications complete all as specified and directed by Engr-in-charge.
JASSI TRADERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .