Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.1 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹9.6 L+₹50,571.52 (5.57%)Rejected-AOC | L2 | Rejected-AOC L2 |
| Sl No | Description | Qty | Unit | Marjan V K L2 | NASIR K A L1 |
|---|---|---|---|---|---|
| 1.00Building Roof Changing | |||||
| 1.00 | 15.28.2:Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking the material within 50 metres lead of :Asbestos cement Sheet | 395.47 | sqm | 40 ₹15,818.8 Lowest | 71.53 ₹28,287.97 |
| 1.00 | OD410222/2025-2026:Steel work for purlin/single section with Structural Steel Hollow sections (round, square or rectangular) including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete (MOD 50.10.2). | 728.38 | kg | 150 ₹1,09,256.4 Lowest | 160.94 ₹1,17,224.83 |
| 1.00 | 13.52.1:Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work | 162.05 | sqm | 130 ₹21,066.24 Lowest | 212.8 ₹34,483.81 |
| 1.00 | OD377857/2025-2026:Supply and fixing 50 mm overall thick Insulated Roofing sheet consisting PU form having density of 40kg/m3 sandwiched between two precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved bynEngineer-in-charge) 0.40 mm thick (+0.05%) on face 1 and , and 0.35mm thick on Face 2 total coated thickness with zinc coating 120grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x100mm) with EPDM seal, complete up to any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (MOD 12.50 of DAR 2021). | 406.83 | sqm | 1,800 ₹7,32,303 | 1,622.79 ₹6,60,207.77 Lowest |
| 1.00 | 12.50:Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. | 12.41 | sqm | 700 ₹8,684.2 Lowest | 724.22 ₹8,984.67 |
| 1.01 | 12.51.1:Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screwscomplete :Ridges plain (500-600 mm) | 48.05 | metre | 500 ₹24,025 | 491.76 ₹23,629.07 Lowest |
| 1.01 | OD377961/2025-2026:Supplying and Fixing Aluminum Automatic turbo ventilator (having 600 mm to 610 mm throat diamter) in cielings including cutting the existing roof, providing and fixing 3m thick Poly carbonate / FRP base flashing and apply a bead of approved roofing sealant along the top of the roof ribs where the base flashing will sit., Position the base flashing over the hole, secure the base flashing to the roof with at least 10 screws or rivets, applying sealant between the base flashing and the roof's ridge cap including all materials and labour charges complete. | 8 | each | 6,000 ₹48,000 | 4,470.5 ₹35,764 Lowest |
Tender Value
₹10.2 L
EMD Value
₹25,423
Closing Date
16 Jan 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
LSGD (LID and EW) Division Kannur DP
Annual Plan-Proj. No. 336/26, Kannur DPManantheri Khadi Kendram Roofing in Chittariparamba GP - Providing Basic Facilities to Various Khadi Centers-General Civil Work
2026_LSGD_826267_7
DB/TN/4(2-A)/25-26
Open Tender
Civil Works - Others
Item Rate
90 days
Kannur
Please refer tender documents.
7 documents required · 7 mandatory
₹2,760
Yes
₹25,423
Yes
17 Mar 2026
7 Jan 2026
19 Jan 2026
7 Jan 2026
16 Jan 2026
7 Jan 2026
Building Roof Changing
15.28.2:Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking the material within 50 metres lead of :Asbestos cement Sheet
OD410222/2025-2026:Steel work for purlin/single section with Structural Steel Hollow sections (round, square or rectangular) including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete (MOD 50.10.2).
13.52.1:Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
OD377857/2025-2026:Supply and fixing 50 mm overall thick Insulated Roofing sheet consisting PU form having density of 40kg/m3 sandwiched between two precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved bynEngineer-in-charge) 0.40 mm thick (+0.05%) on face 1 and , and 0.35mm thick on Face 2 total coated thickness with zinc coating 120grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x100mm) with EPDM seal, complete up to any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (MOD 12.50 of DAR 2021).
12.50:Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
12.51.1:Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screwscomplete :Ridges plain (500-600 mm)
OD377961/2025-2026:Supplying and Fixing Aluminum Automatic turbo ventilator (having 600 mm to 610 mm throat diamter) in cielings including cutting the existing roof, providing and fixing 3m thick Poly carbonate / FRP base flashing and apply a bead of approved roofing sealant along the top of the roof ribs where the base flashing will sit., Position the base flashing over the hole, secure the base flashing to the roof with at least 10 screws or rivets, applying sealant between the base flashing and the roof's ridge cap including all materials and labour charges complete.
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.11 MB
BOQ_1385982.xls
BOQ • 0.30 MB
SBDmanantheri.pdf
Tender Documents • 1.69 MB
NITmanantheri.pdf
Other Document • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .