| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.9 LAccepted-AOC CHARUVILA PUTHEN VEEDU KOTTUKAL NELLIMOODU P O TRIVANDRUM 695524 | TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | 695524 | L1 | Accepted-AOC Agreement executed by Suresh T on agt. no. 178/OF/2020-21 dated. 23/12/2020 |
Tender Value
₹6.0 L
EMD Value
₹15,100
Closing Date
24 Sept 2020, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer
Thiruvananthapuram Corporation 695033
Providing Re-electrification in the old buildings for the Coastal area speciality Hospital Valiyathura under City Corporation Thiruvananthapuram
2020_LSGD_377274_2
TMC/SE/E3/FE4/12776/2019
Open Tender
Electrical and Maintenance Works
Item Rate
90 days
Thiruvananthapuram Corporation
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,300
Yes
online
₹15,100
Yes
22 Apr 2021
15 Sept 2020
28 Sept 2020
15 Sept 2020
24 Sept 2020
15 Sept 2020
60 days
Amount
Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).
90.2.1.1. Single control light point with 6A, three plate ceiling rose
90.2.1.3. Single control light point with out ceiling rose
90.2.1.4. Single controll seleing fan point with 6 A, 3 plate ceiling rose and with socket typped electronic regulator.
90.2.1.6. Combined plug point with 6 A, 5 pin plug socket controlled by 6 A switch in the same switch board as that of light points.
90.2.1.7 Independent plug
Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall and giving connection with 16/0.20mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required.
1200 mm 1X20W LED Lamp with box type fixture
or Supply and fixing angle/straight brass lined skirt type, bakelite batten holder without shade and giving connection etc as required with 10W LED bulb
Supply and providing 5 W LED bulb for BHL light
90.4.1. Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
90.4.5.2.Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required. 1200mm sweep -5star rated ceiling fan complete with 300mm down rod , canopies, shackeles and blades and resistance type regulator working on 230V/240V single phase A/C
1.27.3. Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 4 Module (125mmX75mm)
1.24.5. Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 amp switch
1.28.3 Supplying and fixing following modular base and cover plate on existing modular metal boxes etc. as required. 4 module
1.23.5. Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required. 6 pin 15/16 amp socket outlet
1.27.6. Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 12 Module (200mmX150mm)
1.24.1 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps switch
1.23.4. Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required. 3 pin 5/6 amp socket outlet
1.28.6 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 12 Module
1.21.1. Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm
90.6.4.12 .Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes. 1.50 sq.mm 2 Run
90.6.4.13 1.50 sq mm 3 run
90.6.4.14 1.50 sq mm 4 run
90.6.4.16 1.50 sq mm 6 run
90.6.4.22 2.50 sq mm 2 run
90.6.4.34 4.00 sq mm 4 run
90.6.4.44 6.00 sq mm 4 run
2.5.4. Supplying and fixing following ways surface/ recess mounting vertical type, 415V TPN MCB distribution board of sheet steel, dust protected duly powder painted inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer) as required (Note: vertical type MCB TPDB is normaly used where 3 plate outlets are required) 4 way, (4.24) Double door
2.4.4. Supplying and fixing following way,horizontal type three pole and neutral, sheet steel, MCB distribution board,415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way, (4+12) Double door
2.3.4. Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator 16 way, Double door
2.13.3. Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 100 amps
2.13.2. Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
2.12.1.Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
2.15.3. Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A
2.10.1. Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
2.14.2. Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
Supply and drawing bare copper conductors of the following sizes along with wiring cables and giving connections etc as required.
5.2. Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required
or Supply and laying bare earthing conductors of the following sizes laid 0.6 m below ground level including excating trench of suitable size and refilling etc. as required.(In ordinary soil) 3.15 mm copper conductor (10 SWG)
90.3.18.2 Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required. 32 mm dia with HG company fabricated clamps
(MR1183) 36/40W 4000 lumen LED, IP66 street light fittings with Aluminium housing stove enameled CRCA sheet, Steel reflector cover, acrylic cover complete with THD <10%, power factor>0.98, ROH complaint duly wired up for use on 230 V ac supply
Supply and fixing cast aluminium stove enameled bulk head fitting with deep drawn anodised alumi8nium body, epoxy powder coated, heat resistant prismatic glass cover suitable for 9 W CFL to wall/ceiling including giving connections with required length of 16/0.20mm PVC insulated and PVC sheather 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and making good the surface as required
Charges for cutting holes suitable for accommodating exhaust fancs of sizes up to 305 mm sweep including plastering, colour washing etc. as required.
300/305 mm, single phase, light duty exhuast fan in metal frame working on 230 V A/C
S & F switch disconnector unit (isolator) complete with handle assmebly, door inter lock and padlocking arrangement of the following ratings
63A, AC 23 A, TPN SDF for DIN fuse
Supply and fixing the following accessories in the existing meter board and giving connections etc.
63A, 415 V, DIN type fuse base.
63A, 415 V, Backlite fuse fitting
100 A, 415V, 2 way neutral link mounted on DMC/SMC base.
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_547386.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .