Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹56.4 LAccepted-AOC E 22 APIIC PEDAGANTYADA APIIC VISAKHAPATNAM ANDHRA PRADESH 530044 | VISAKHAPATANAM | ANDHRA PRADESH | 530044 | L1 | Accepted-AOC L1 | |
| 2 | L2₹64.4 L+₹8.0 L (14.2%)Rejected-AOC | L2 | Rejected-AOC L2 |
Tender Value
₹64.6 L
EMD Value
₹1.3 L
Closing Date
18 Jun 2024, 3:30 pmClosed
Chief Engineer
Chief Engineer, UC-1 annex office, BARC(V) main campus, Gajuwaka -Yellamanchili Road, Maduturu Sub Post Office, Visakhapatnam-531 011
Annual Maintenance Contract for Civil, Plumbing, Sanitary and Carpentry Works at various locations of ANU VIHAR and BARC main campus at Atchutapuram near Visakhapatnam, A.P.
2024_BARC_808810_1
BARC (V)/CES/CivilAMC/152 Dated 24.05.2024
Open Tender
Civil Works - Buildings
Item Rate
365 days
Atchutapuram, Visakhapatnam
Please refer Tender documents.
6 documents required · 6 mandatory
₹0
₹1.3 L
Atchutapuram,Visakhapatnam
30 Jul 2025
27 May 2024
24 Jun 2024
27 May 2024
18 Jun 2024
13 Jun 2024
27 May 2024 - 10 Jun 2024
10 Jun 2024
Amount
General Notes: 1) The make/model/brand for all the BOQ items shall be as per suggestive makes of Annexure-B of Section-VII of the tender document. The make/model/brand mentioned in Annexure-B of Section-VII of the tender document is merely for guidance and bidders can prefer any other make which is meeting technical specifications given under Section-V and Schedule of Quantities of Tender document and shall confirm to the relevant BIS codes and other relevant codes. However, the bidder may suggest any equivelent make/ model/brand meeting technical parameters on or before pre-bid conference for approval of BARC(V). 2) Only sieved river sand/crushed stone sand from Godavari river or Varaha river or Vamsadhara river or Sarada river or Nagavali river / Crushed stone manufactured sand shall be used as fine aggregate and Graded hard broken granite metal of 3 stage (VSI) material shall be used as coarse aggregate in relevant items. Specification for fine and coarse aggregate shall confirm to IS:383 (latest revision) 3) In view of limit on water-cement ratio for durability requirements in design mix concrete, concrete admixtures (Carboxylate based superplasticizers) can be used after taking prior approval of Engineer-in-Charge and the rates quoted for concrete items shall be inclusive of the cost of admixtures, Design mix, trial mixes, testing (at site & at approved labs), etc. complete. 4) The contractor shall set up sufficient number of self loading mobile concrete mixers inside the project area for the production of concrete. 5) Contractor may also be allowed to procure concrete from prior approved RMC plants on prior approval of the BARC subject to maintain required slump at site during pouring.To that extent suitable Mix Design should be carried out with required retention period. No extra payment will be made if concrete is brought from RMC plants outside the project area. 6) Manufacturer's Test certificate of cement which is procured from dealer/company is to be submitted for all cement related works by the contractor.
7) The Scope of works which are not included in any specific items but indicated in the document "General Scope of all works" shall be within the scope of overall contract works. The cost of work/item/material indicated in this document shall be deemed to be included in the quoted rates of all individual items. 8) The quoted rates shall include necessary taxes, royalties, seigneiorage charges,etc. and all other charges to supply all the required construction materials. 9) For all standards and code of practices, specifications, like Indian Standard, MORT&H, ASTM, etc. refer only latest revisions including all applicable amendments, revisions and additional publications (during contract period) and these have to be followed. 10)Prior approval for source of all construction materials by submission of relavent test certificates, documents, invoices etc. have to be taken from BARC. 11) All the tests mentioned in Quality Assurance Plan(QAP) should be carried out without any extra cost to BARC. 12) The contractor has to submit all royalty /seigneiorage slips,etc for all the naturally available construction materials before submitting the RA bills. 13) All dismantel items shall be handed over to BARC(V) in good condition. 14) All transport for men and materials inside BARC main campus and Anu Vihar shall be in the scope of contractor.
The following shall be provided by the contractor at site during the entire contract period for operation of the all BOQ items for which no seperate payment will be made. Contractor has to quote the rates for all BOQ items accordingly. 1. Wheel barrows 2. One two wheeler bike 3. Suitable ladders 4. Ropes 5. Chain Pulley 6. Tripod 7. Any other necessary power tools and tackles
From 0.00m to 1.50m below average GL
From 1.50m to 3.00m below average GL
PCC, RCC & FORM WORK Note: 1) Rates quoted for PCC & RCC items shall include cost of sieved river sand/ crushed stone sand as fine aggregate and graded hard broken granite metal as a coarse aggregate. 2) The mix shall be desiged to maintain the desired slump (as required at site/specified in IS code). In view of limit on water-cement ratio for durability requirements in design mix concrete, admixtures (corboxalite based superplasticizers) can be used after taking prior approval of Engineer-in-Charge and the rates quoted for the items shall be inclusive of the cost of admixtures, trial mixes, testing (at site & at approved labs), etc. complete. 3) The contractor shall set up sufficient number of Self loading mobile concrete mixers inside the project area for the manufacture of concrete. 4) Contractor may also be allowed to procure concrete from prior approved RMC plants on prior approval of the BARC subject to maintain required slump at site during pouring. To that extent suitable Mix Design should be carried out with required retention period. No, extra payment will be made if concrete is brought from RMC plants outside the project area. 5) The rate of concrete shall include all labour, equipment, charges for mixing & cost of admixtures. 6) Test certificate of cement, procured from dealer/company has to be submitted for all concrete works by the contractor. 7) Rate quoted for RCC items shall include cost of relevant design mix and testings.
8) This item is applicable for all PCC and RCC structural elements like footings, beams, columns, slabs, lintels, chajjas, walls etc., for all heights and leads. 9) Only steel scaffolding, staging, supporting system to the formwork and steel frame work will have to be used for all RCC structural elements. 10) All surfaces adjacent to EPs, etc., shall be in true line and level & irregularities, if any, shall be rounded by mechanical grinding, chiseling, finishing the same using epoxy silica sand mortar at no extra payment. 11) Form finish F3 shall be provided to all exposed surfaces of the concrete.
Providing and laying in position cement concrete of 1:3:6 (1 cement, 3 river Coarse river sand/ crushed stone sand, 6 graded stone aggregate of maximum size 20 mm) at all elevations including consolidation, finishing curing etc. complete all as per drawings and technical specifications and as directed by the Engineer-in-Charge including the cost of form work shuttering, centering all as directed by Engineer-in-charge.
Providing and laying in position cement concrete of 1:2:4 (1 cement, 2 crushed sand, 4 graded stone aggregate of nominal size 20 mm) including consolidation, finishing, curing etc. complete as per specification and drawings including the cost of Formwork shuttering, centering and steel reinforcement at all Level.
Providing and laying design mix reinforced cement concrete of M30 Grade using min. 390 kg of cement for 1 cum of finished concrete at all heights by weigh batching using graded stone aggregate of 20mm max. size and coarse river sand/ crushed stone sand of approved quality including admixtures of approved and quality, including handling & transportation, scaffolding, mechanical mixing, placing to required location by hoisting and / or pumping & mechanical vibration, consolidation, finishing, curing, hacking of concrete surfaces wherever required etc. complete at all levels in substructure/superstructure as per specifications & also including dewatering, if any, complete all as per drawings and technical specifications and as directed by the Engineer-in-Charge but excluding formwork, shuttering and steel reinforcement. Note: Temparature raised due to heat of hydration shall be kept within limits in raft/mass concrete by keeping proper curing mechanism.
Providing, centering, shuttering Form work using Film faced plywood to get a neat form finish surface for all types of structures including necessary strutting, steel frame work/H-beams, steel proping, staging, supports etc and deshuttering the same after the specified time all as per drawings and technical specifications and as directed by the Engineer-in-Charge
sub structure
super structure
Providing centering, shuttering Form work using steel plates, timber planks for all types of structures including necessary strutting, proping, staging, supports, bracings etc. and deshuttering the same after the specified time all as per drawings, specifications and as directed by the Engineer-in-charge at all levels.
sub structure
super structure
Notes for Reinforcement steel: 1) 1.2mm dia annealed binding wire required for the work will have to be supplied by the contractor at their own cost and will not be measured for payment. 2) Fe-500D / Fe-500EQR bars as per IS 1786 latest code to be supplied by the contractor. 3) Reinforcement bars from conversion agents / re-rollers of above manufacturers, will not be accepted. 4) No extra payment will be made on account of Rolling Margin & wastage. 5) Contractor shall supply copy of the documentry evidence of purchase of steel, test certificate from these manufacturers and also test from third party to be carried out at no extra cost. 6)Reinforcement steel required for the work shall not be supplied by the Department.
Providing Reinforcement steel of all diameters for reinforced cement concrete at all levels. including supplying, preparation of bar bending schedules, cutting, bending, hoisting ,transporting to all elevations, placing and keeping in positions, all leads, fixing, tieing with 1.2 mm dia annealed binding wire including all labour charges, cost of cover blocks (in same grade of concrete) of various thicknesses and sizes etc. all as per drawings and technical specifications and as directed by the Engineer-in-Charge. Using TMT Bars of Specified Grades of all sizes.
Notes for Sturctural steel 1) Structural steel required for the work shall not be supplied by the Department. 2) Structural steel confirming to IS 2062 shall be supplied from their own plants rolled from virgin materials to be procured directly or from their authorised dealers and test cerificate to be produced. 3) The contractor shall supply documentary evidence of purchase of steel, Test certificate from approved manufacturers and also third party testing from approved laboratories with out any extra cost. 4) Welding weights, connections, bolts and nuts shall not be measured for payment but the cost of which shall be deemed to have been included in the rates. 5) Holes to be drilled only by Drilling machines and gas cutting of holes are not permitted. 6) Rate inclusive of all consumables like gas, welding electrodes and tools and tackles etc. 7) The Liquid Penetrant Inspection shall be carried out in 1% of the total joints and as directed by Engineer-in-Charge without any extra cost.
Providing Structural steel work Up to and including 300 mm Joists, 350 mm channels, and below sections using angles, channels, joists and other sections, welded and / or bolted including in built up sections for columns, beams, trusses, structural steel floors, frame works, monorails and other structures including supplying, cutting, drilling, welding, fabricating, hoisting, fixing in position, applying a priming coat of zinc chromate steel primer. complete all as per drawings and Technical specifications and as directed by the Engineer-in-Charge.
Providing, supplying, cutting, welding, fabricating, hoisting and fixing in position structural steel members for gates, hand rails etc. using MS hollow circular / square / rectangular sections along with the associated connections including applying a coat of primer using redoxide before and after erection and two coats of first quality anticorrosive polyurethene paint all as per Technical specifications, drawings, complete all as per drawings and specifications and as directed by the Engineer-in-Charge.
Providing and fixing at all levels MS bolts including nuts and washers of approved size & quality as per requirements and as per specifications, drawings complete all as directed at siteby the Engineer in charge.
Providing and fixing precoated Galvalume Roofing profile sheets of approved size, shape and pitch up to and including 0.5mm thickness sheet. The sheet shall be fixed using self drilling / self tapping screws of size (5.5 X 55 mm) with EPDM seal complete upto any pitch in horizontal / vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including ridges,cutting to size and shape wherever required as directed by the Engineer-In-Charge.
Providing and constructing 100/150/200/230mm (or as directed) thick masonry at all elevations with approved quality Fly ash/ FAL-G bricks (confirming to IS 12894) having minimum crushing strength 60 Kgs/Sq.cm and water absorption of maximum 20%, in cement mortar 1:6 (1 cement : 6 river sand/m-sand) crushed stone manufactured sand) uniformly mixed in machine in specified courses of approved bond complete including pointing, raking out joints, curing, cleaning, including independent double legged scaffolding, at all heights, depths and leads, dewatering area where required etc., all as per typical drawings, Technical specifications and as directed by the Engineer-in-charge. including all leads and lifts etc. Note for flyash bricks: In the fly ash bricks the mix confirming to the strength mentioned in the respective items shall be got approved by the department. The mix shall consist of ordinary portland cement content of not less than 20%(preferably) of the mixture consisting of Fly ash, OPC and Gypsum or any variation in proportion of design mix shall be submitted to BARC for approval. The Anhydraous Gypsum, Fly Ash, Cement, Crusher dust and other materials shall confirm to the relevant IS codes. The Anhydrous Gypsum shall be procured from a reputed source approved by the department. Roller mixer shall be used for good homogeneous mixing. No holes in brickwall will be allowed for scaffolding. Only double tubular steel scaffolding be allowed.
Providing 15 mm thick Plastering in cement mortar 1:4 (using river sand) finished smooth, including sieving of sand to required fineness, preparation of the surface, double steel tubular scaffolding, curing all as per specifications, drawings and as directed at site etc. complete all as per Technical specifications and as directed by Engineer-in-charge. including all leads and lifts
FLOORING WORKS NOTES: The contractor shall submit all samples to the department for approval and no work shall commence before such samples are duly approved.
Providing and fixing Glazed VITRIFIED tiles of size 600mmx600mmX8mm/600mmX300mmX8mm approved in different sizes conforming to IS 15622 in all colours and shades in Glossy or Matt or satin finish laid over a bed of minimum 20 mm thick bed of cement mortar 1:4 (using Crushed sand) and jointing with grey cement slurry including grouting with the joints with white cement based Tile Grout of approved and matching shade complete as per patterns, drawings and specifications complete as directed by the Engineer-in-charge.
Providing and Fixing Homogeneous 2.00 mm thick PVC sheet / tile in flooring and skirting in approved pattern on a smooth and damp proof base using rubber based adhesive of approved quality and manufacturer including, levelling small undulations with plasterof paris if required , rolling with light wooden roller weighing about 5 kg all complete as directed by Engineer-in-charge in approved colour and shade
Providing and Laying Minimum 25 mm thick uniform shade Kotah or as approved stone for treads and risers of steps, skirting,window sills in single length up to 2.00 metres length slab dado and pillars laid on 12 mm thick (average) cement mortar 1:3 (using crushed sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing to obtain mirror finish complete as per specifications, drawings and as directed by the Engineer-in-charge
Providing and fixing 17mm thick machine cut, mirror polished approved Granite stone/equivalent approved range and shade granite stone of approved colour and pattern for Risers and trades /Frames/Architraves/soffits/Jambs/Sills/Urinal partitions etc. of required sizes as shown in drawing or directed by the Engineer-in-charge, fixed with cement paste about 4.0 Kgs/sqm, fully buttering cement slurry on back, fixed to correct line, level and plumb over the plastered surfaces. Joints shall be well cleaned and grouted with matching colour of approved readymade grout, all leads and lifts, polished to all exposed faces, corners and edges, semi rounded, providing required SS screws, SS pins, studs, cleaning, curing, drilling, grinding edges etc. complete at all heights and leads all as per technical specifications complete as per specifications as directed by Engineer-in-charge.
Providing and fixing ISI marked 35mm thick Block board nondecorative type single/double leaved Flush Door Shutter as per IS 2202, core of solid block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering and fixing with ISI marked S.S hinges all as per drawings and specifications including providing lipping all around with second class teak wood battens of size 25mm minimum depth on all edges of shutter (overall area of shutter is to be measured) . The cost shall include materials and labour, all as per technical specifications complete as per specifications and dispose the same from the site by the contractor as directed by Engineer-in-charge. (The cost of S.S. hinges only will be paid under relevant item).
Providing and fixing 30 mm thick WPC (wood plastic composite) Flush door shutters of minimum density 0.6 gm/cm3 with specified color and pattern of design. complete all as per specifications and as directed by the Engineer-in-Charge. Note : 1. WPC Door sample to be got approved by the Engineer-in-Charge before procurement. 2. The quoted rate shall include cost of fixtures, paint mentioned above including the WPC shutter and frame.
Providing and fixing Stainless steel double ball bearing butt hinges of size 100 x 75 x 3 mm thick for hollow steel door of approved complete as per specifications, drawings and as directed by Engineer-in-charge. (For hollow metal doors & fire doors indicated in the schedule elsewhere). Sample to be approved by the Engineer In charge
Providing and fixing stainless steel aldrops of size 300 X 14 mm of approved with necessary screws, bolting from rear side complete as per specifications complete.
Providing and fixing stainless steel tower bolts of size 250 X 12 mm of approved with necessary screws etc. all as per specifications and as per drawings.
Providing and fixing Al hanging Heavy Quality floor door stopper ISI marked with Twin Rubber stoppers, anodised (anodic coating not less than grade AC10 as per IS:1868)transparent or dyed to req. colour or shade with necessary screws etc. all as per specifications and as per Drawings and as directed by Engineer-in-Charge. Sample to be approved by the Engineer In charge
Providing and fixing pair of Stainless Steel "D" type Door handles 10 mm dia, 250 mm long with full length plate in Steel Doors/ wooden Doors with necessary screws etc. all as per specifications and as per Drawings and as directed by Engineer-in-Charge. Sample to be approved by the Engineer In charge.
Providing and fixing aluminium handles 175 mm long Inner grip 125 mm with 12 mm dia rod plate type BOW handles ISI marked of approved, anodised transparent or dyed to req. colour or shade with necessary screws etc. complete.
Providing and fixing brass mortise latch and lock of godrej or approved with 6 levers and a pair of lever Brass handles with necessary screws etc complete suitable for fixing in wooden / steel/ FRP/ doors as per specifications.
Providing and fixing locks for aluminium sliding window shutters (Overall size of 204mmx23mm) of approved quality, type all as per specifications complete as directed by the Engineer-in-charge
Providing and fixing double action brass cast hydraulic floor spring (IS:6315-Table 1) for doors including cost of cutting floors as required, embedding in floors and S.S./ Brass cover plates with brass pivot and single piece M.S. Sheet outer box with slide plate etc. complete.
Providing and fixing 25 mm S.S curtain rods of 1.25 mm thick with two brass brackets fixed with brass screws and wooden plugs etc. wherever necessary complete.
Providing and fixing Al die cast body tubular type universal hydraulic door closer of godrej or with necessary accessories and screws etc. in wooden doors / steel doors with necessary bolts & nuts complete as per specifications and as directed by Engineer-in-Charge.
Providing and fixing aluminium hanging heavy quality floor door stopper ISI marked with twin rubber stoppers, anodised transparent or dyed to required. colour or shade with necessary screws etc. complete.
Providing and fixing hand rail using 304 grade Stainless Steel pipes or any other shape of approved size and quality by TIG welding, mirror / matt polishing, fixing at site etc. for balcony railing & staircases railing including special sections as per drawings, specifications. A sample to be fabricated and to be got approved by the Engineer-in-Charge before starting of work at site. This work to be executed through approved qualified welder etc., complete as per specifications all complete as per specifications as directed by Engineer-in-charge. (Cost including all materials and labour)
Providing and fixing pre-laminated particle board flat pressed 3 layer or graded wood particle board conforming to IS 12823 Grade-I, Type - II in panelling fixed in aluminium doors, windows, shutters and partition frames with C.P Brass / Stainless steel screws etc. complete as per architectural drawings and directions of Engineer-in-charge Prelaminated particle board with decorative lamination on both sides.
9 mm thick
12 mm thick
Supplying, fixing 50 mm thick Thermocole sheet Heavy Density 18 Kg / m3 in pota cabins wall panelling as directed by the Engineer In Charge.
Supplying and fixing 19 mm thick marine plywood conforming to IS 710 including all fittings and fixture, labour charges etc. as directed by the Engineer In Charge.
Providing and fixing Colour anodized (of 20 micron thickness) aluminium work for shutters, windows, ventilators, Alu Louvers, wall spans and partitions etc. with extruded built up standard tubular sections / Z Sections and other sections confirming to IS 733 and IS 1285 fixed with rawl plugs and stainless steel screws or with fixing clips or with stainless steel expansion hold fastners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC / neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically where ever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P brass / stainless screws all complete as per architectural drawings and as per direction of Engineer-in-charge including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required. (Weight of the Aluminium sections shall not be less than Specified in the drawings). The work shall be carried out complete as per approved shop drawing and the relavent portion of technical specifications and as directed by Engineer-in-charge.
Providing and fixing Powder coated (minimum thickness of powder coating 50 micron) aluminium work for shutters, windows, ventilators, Alu Louvers, wall spans and partitions etc. with extruded built up standard tubular sections / Z Sections and other sections confirming to IS 733 and IS 1285 fixed with rawl plugs and stainless steel screws or with fixing clips or with stainless steel expansion hold fastners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC / neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically where ever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P brass / stainless screws all complete as per architectural drawings and as per direction of Engineer-in-charge including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required. (Weight of the Aluminium sections shall not be less than Specified in the drawings). The work shall be carried out complete as per approved shop drawing and the relavent portion of technical specifications and as directed by Engineer-in-charge.
Note for Aluminium work 1) Only anodized aluminium sections, aluminum beading, aluminium sheets & aluminium handles used will be measured for payment. The rate quoted is deemed to have included the cost of all brass concealed tower bolts, screws, gasket, weather strips, PVC lining, etc. and no seperate measurement / payment will be made for the same. 2) Glass, particle boards, aluminium grills, brass mesh, louvers, etc. will be measured & paid separately under relevant items. 3) All fittings shall be of matching colour anodised of aluminium sections. 4) A long M.S. Rod at both ends to be provided in all aluminium shutters in top & bottom horizontal members internally connecting vertical members and fixed with M.S. washers and nuts. No measurement and payment shall be made for this. 5) Aluminium Frames to be fixed with walls / columns with minimum 100 mm long Brass screws / Stainless steel screws and necessary hold fasts. For fixing of frames with RCC members, for Aluminium windows/louvers, doors having area of equal to 10 sq.m or above, Carbon steel zinc coated anchor fasteners shall be used. No seperate measurement and payment shall be made for these items. 6) All aluminium frame and shutters Joints shall be of mitred joints with necessary cleats/ plates. 7) Filling the gap between aluminium frame & adjacent RCC / Brick work / Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete up to 5 mm depth and 5 mm width.
Providing and fixing following type of approved quality glass panes for doors/windows/ventilators/wall spans/shutters, etc. fixing with aluminium frame work including fixing aluminium channel beading (to be paid under relevent item) and providing and fixing with 2way EPDM gasketing ,to ensure water and air tightness and neoprene cushions /gasket accommadated in grooves all complete generally as per drawings specifications and as directed by the Engineer-in-charge. Note: Glass shall be measured as per inner dimensions of the aluminium frame sections to which the glass is fixed.
5 mm thick clear float glass
5 mm thick bajra (translucent) glass for windows/ louvers
NOTES FOR PAINTING WORKS: All external/internal painting works will have to be done with erecting double tubular steel scaffolding only. No jhoola/Bhada shall be permitted. All rates quoted in the above painting items shall include erection of double tubular scafolding and provision of safety measures like safety belts, eye protection gears, etc.
Providing and applying white cement based wall putty over concrete or Plastered surface up to 3 mm thick to get uniform surface free from undulation including cleaning complete all as per technical specifications as directed by Engineer-in-charge.
Providing and applying Wall painting Two coats on with Premium Acrylic emulsion paint to give an even shade, including a coat of approved Cement Primer, including preparation of the surfaces, scaffolding complete all as per technical specifications and specifications as directed by Engineer-in-charge.
Providing, painting, finishing walls with Premium Acrylic smooth exterior paint on sand face plaster / plain plaster & concrete surfaes with Silicone additives of required shade (Two coats, each applied @ minimum1.43 ltr / 10 sqm) over and above a base coat of water proofing cement paint to be applied @ minimum 2.20 kg / 10 sqm including preparation of the surfaces, including erection of double tubular scafolding complete all as per technical specifications as directed by Engineer-in-charge.
Providing, Painting on old work (two or more coat) with premium acrylic emulsion paint of approved and manufacturer to give an even shade including preparation of the surfaces, scaffolding complete. as per specifications and as directed by the Engineer-incharge
Painting with black anti corrosive bitumastic paint of approved to give an even shade with one or more coats on old surface as directed by EIC
Providing white washing with ready mix lime powder to give an even shade over new work (two coats), including scaffolding as per specifications and as directed by the Engineer-in charge.
Providing and painting two coats on steel/wood surfaces (old/new) with synthetic enamel paint required colour to give an even shade over a coat of zinc chromate primer including preparation of the surfaces, scaffolding complete all as per technical specifications as directed by Engineer-in-charge.
Providing and fixing white vitreous European type Water Closet with'P' or'S' Trap with solid seat and lid, 10 litre low level white PVC flushing cistern with manually controlled device (handle lever) conforming to IS:7231, flush bend,fixing EWC with C.P brass screws, 15mm PVC heavy quality inlet connection of 450mmlong, including testing , commissioning & cleaningetc. complete all as per drawings and specifications and as directed by the Engineer-in-charge.(Samples to be got approved by the EIC)
Providing and fixing in position 530 x 410 mm star white glazed vitreous Indian Water Closet (Orissa Pattern) with 'P' or 'S' trap, Low level 10 litres capacity PVC flushing cistern including all internal fittings fixed with 32 mm dia heavy quality PVC flush pipe connecting cistern to the closet, CP extension nipple, overflow pipe from cistern with CP brass mosquitoproof jali upto 150mm above floor level concealed in wall, 15mm dia concealed CP angle valve with heavy quality reinforced 600 mm long PVC inlet connection pipe & CP wall flanges whereever required, embedding the closet in 1:3:6 plain cement concrete and levelling as per floor finish, etc. all as per specifications and as directed by Engineer-in-charge.
Providing and fixing white viterious wash basin of size 630 x 450 mm and colour with anchored set arrangement, 15 mm C.P. brass pillar tap,15 mm x 600mm long PVC Inlet connection, 32mm heavy quality C.P. brass waste coupling including stop cock of standard pattern and SS wall flanges, cutting and making good the walls and testing complete all as per specifications and as directed by the Engineer-in-charge.(Samples to be got approved by the EIC)
Providing and fixing stainless steel AISI 304 (18/8) satin finish kitchen sink with drain board with over all size of 1145 x 510 mm and bowl size of 560 x 410 mm and 200 mm depth and model with C.I. brackets and stainless steel waste coupling, fittings, including painting the fittings and brackets with 3 coats of white enamel paint over a coat of primer, cutting and making good the walls wherever requried.complete as per specifications and as directed by the Engineer-in-charge.
Providing and fixing white vitreous china flat back half stall urinal size 580 x 380 x350 mm with 32mm C.P Flush value with standard flush pipe and C.P. brass spreaders, 32mm Urinal waste coupling with Dome grating , and clamp etc. including making G.I water line connection (Only G.I.pipes will be paid under relevant Item). Samples to be got approved by the EIC.
Providing and fixing 15 mm CP Urinal Spreader size with 1/2" BSP thread and shapes, weighing not less than 60 gms (Samples to be got approved by the EIC)
Providing and fixing Brass 15 mm C.P. Presstomatic series Auto shut Urinal Flush cock quality alongwith heavy quality reinforced 600 mm long flexible PVC inlet connection pipe etc. complete.(Samples to be got approved by the EIC)
Providing and fixing 15mm braided hose with nuts, nipples for Water inlet connection of 450 mm long Braided hose.
Providing and fixing 6 mm thick Mirrors of size 600 x 450 mm with bevelled edges complete with 6 mm thick WPC back ground fixed to walls with C.P. brass screws and concealed washers complete. all as per specifications and as directed by the Engineer-in-Charge .
Providing and fixing in position heavy quality CONTINENTAL type, fancy variety 15 mm C.P. brass screw down Bib taps with C.P. wall flange conforming to IS:8931 using tefon tape as directed by Engineer-in charge, testing and commissioning etc complete. (Samples to be got approved by the EIC)
Providing and fixing 15 mm C.P. Brass 2 in 1 Bib cock combination of Heavy Quality using teflon tape as per specifications and as directed by the Engineer-in-charge.(Samples to be got approved by the EIC)
Providing and fixing 15 mm n.b of C.P Brass Angle cock of Heavy Quality of continental model as per specifications and as directed by the EIC (Samples to be got approved by the EIC)
Providing and fixing Heavy quality CP brass waste coupling of following dia. for wash basin, sink and urinal of approved size and quality, all as directed complete. CP brass waste coupling 32mm dia and minimum 79mm length half threaded or full threaded as per requirement as directed by the Enginner In Charge.
Providing and fixing Heavy quality CP brass bottle trap 31/32 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling 77 mm breadth with 25 mm minimum water seal for wash basins/urinal etc. all as per specifications and directed by the Engineer-in-charge.
Providing and fixing in position 15 mm CP Health faucet with necessary flexible hose upto 1500 mm long using tefon tape, CP wall bracket, CP nozzle, CP wall flanges, etc., complete.
Supplying and fixing of C.P hanger having minimum 3nos hook complete fixed to walls with 30 mm CP brass screws with concealed fitting arrangement all as directed by the Engineer-in-charge.
Providing and fixing PVC Nahani trap of self cleaning design of 100 mm inlet and 75 mm outlet, jointing with Lead with the connection pipes, placing as per the drawings, embedding in Cement concrete 1:2:4 and making circular hole up to floor level using 110 mm O/D PVC pipes of 6 Kg/sq.cm pressure and fixing 1 No. 125 mm dia PVC openable grating, complete all as per drawings and specifications and as directed by the Engineer-in-Charge.
Providing and fixing 40mm Heavy quality Flexible PVC waste pipe (Semi rigid or Flexible) 1200mm legth with fittings for sink or wash basin including PVC waste fittings etc. complete all as per specifications and as directed by the Engineer-in-Charge
Providing and Fixing Chlorinated PVC (CPVC) pipes having thermal stability for hot & cold water supply(as ASTM standard 2846 & SDR-11 grade) including all CPVC plain & brass threaded fittings, including necessary CPVC specials fixing the pipe with clamps including chasing the walls, concealing the pipes and marking good the same etc. This includes jointing of pipes & fittings with CPVC solvent cement & testing the joints complete all as per specifications, drawings and as directed by the Engineer In Charge.
15 mm pipe
20 mm Pipe
25mm Pipe
32mm Pipe CPVC
Providing, laying, jointing, fixing, testing and painting with 2 coats of enamel paint over a coat of primer as per colour code of heavy quality (Class 'C') M.S. Galvanised pipes (External) as per IS:1239 incluidng fittings like elbows, collars, tees, unions, couplings, reducers, enlargers, bends & all other fittings, required for the completion except screwed flanges conforming to IS:1239 & also as per the code of practice of water supply in buildings of IS: 2065 including laying under the floors, chasing / cutting / making holes in walls, roof slabs & making good the same to the original conditions, including cost of all jointing material like hemp yarn, teflon tape, white or red lead, clamps, pipe supports, hangers, screws, cement, sand, testing the pipes with clean water for 10 kg/cm2 pressure with minimum period of 2 hours duration complete all as per drawing, and the relevant portion of the technical specifications and as directed by Engineer-in-charge, etc. complete. MS flange pipe, its rubber washer also.
15 mm n/b G.I pipe
20 mm n/b G.I pipe
25 mm n/b G.I pipe
32 mm n/b G.I pipe
40 mm n/b G.I pipe
50 mm n/b G.I pipe
63 mm n/b G.I pipe
Providing and fixing PVC rain water pipes conforming to IS:13592 Type B and PVC SWR Fittings & specials confirming to IS 14735/1999 including jointing with seal ring / With PVC solvent adhesive including fixing in walls using clamps, wooden supports of min. size 300 mm with well seasoned wood etc. complete all as per drawings, specifications and as directed at site.
SWR PIPE OD 75mm O/D
SWR PIPE OD 110mm O/D
Dismantling of RCC works including Cutting and stacking of steel reinforcement bars and disposal of unserviceable materials within 100 m lead and disopse the dismantiled reinforcement steel from the site and as directed by the Engineer-in-charge.
Dismantling plain cement concrete manually/ by mechanical means carefully without damaging adjacent structures including disposal of debriswithin200mlead as per direction of Engineer-incharge.
Dismantling brick work in Cement mortar carefully without damaging adjacent structures includingstackingof materials and dispoal of unserviceable materials within100 mlead as per direction of Engineer-in-charge.
Dismantling doors, windows and clear storey openings (steel / wood) shutter including chowkhats, architraves, holdfasts etc.complete and stacking within 100 m lead (full windows) Of area3.00 Sq.M and below and dispose the same from the site
Dismantling roofing G.I Sheet / FRP Sheet / AC Sheet including ridges, valleys and gutter etc and stacking the material within 50 m lead
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 100 m lead For thickness of tiles above 10 mm and up to 25 mm
Dismantling of 15 to 100 mm dia GI/CI Pipe exposed on walls including stacking of diamantled pipes within 50m lead as directed by EIC
Lead charges for lead Exceeding 2 KM but not exceeding 3 KM, by mechanical transport including loading, unloading, stacking / levelling etc
Supply of heavy pattern screw down gun metal gate valve with handles and wheels including testing for 10Kg/cm2 pressure with clean and potable water with a minimum testing duration of two hours etc.as per specification and as directed by the Engineer-in-charge
Core cutting in RCC beyond 100 mm up to and including 150 mm Dia
Core cutting in RCC beyond 150 mm up to and including 200 mm Dia
Cutting holes of required size in Brick masonry wall including fixing nof 300mm dia PVC pipe confirming to BIS 12818 and making good the same etc. complete as directed by the EIC.
Supplying of 20mm size aggregates at site of work as required and as directed by the Engineer-in-charge, complete. All labour and materials.
Providing and fixing Stainless Steel 304 fly proof mesh 16x24 (16 mesh and 24 gauge) of square weave as per specification and as directed by Engineer-In-Charge.
Supplying and injecting with approved quality chemical emulsion imedochloprid at the rates and concentrations as per IS code for post Anti-termite treatment by providing drills at 300 mm center to center all along the skirtings and door & window frames etc apply the chemical with power sparyer, close the holes with white cement putty and make good to existing buildings as per manufacturers specifications and as directed by the Engineer-in-Charge. Work to be executed by approved agency . Measurment will be taken only floor area for Payment
Modification of existing IWC to EWC in toilet of size 1.3mX1.05m (4ftX3ft) in quarters including dismantling of existing FRP door, floor tiles, concrete bed for existing IWC, flush tank etc. carefully and supplying and fixing of white vitreous EWC, 2 in 1 CP bib tap, PVC health faucet with 1.5m hose, 25mm thick WPC door shutter with all heavy quality SS hardware and laying of new anti skid bathroom floor tiles etc. make good everything and also dispose the removed FRP door out of BARC colony premises and other debris within a lead of 200m etc. complete all as directed by the EIC.
Providing and Fixing Anchor Fastner including drilling in concrete as per requirement for fixing Eps or other structures all as specified by the manufacturer complete all as per specifications and drawings.
16 mm diameter 75 mm Long
16 mm diameter 100 mm Long
16 MM diameter 150 mm Long
16 MM diameter 200 mm Long
20 mm diameter 100 mm Long
Supplying and fixing of 10 lit flush tanks in toilets including all accessories like bend pipe, brackets, etc.as directed by the EIC
Providing all kinds of civil maintenance services by supplying plumber/ carpenter/mazdoor with all necessry tools (including hand drilling machines , hand cutting machines, ladders,spaners etc.) & tackles for attending complaints of minor repairs, fixing, fitting & fixures,miscellaneous works and repairs,dismantling etc. as and when required and as directed by EIC on day to day basis as per requirement from BARC. Note: (i) "Job" means work carried out in full office hours in a day as direrected by EIC. (ii) If the contractor fails to provide manpower as per Item no. 96.1 and 96.2, Rs. 1500/- and Rs. 1000/- shall be deducted for Item no. 85(i) & (ii) respectively from the bill.
Mason/plumber/carpenter- 1st Class
Man mazdoor/woman mazdoor- unskilled
Cleaning of Septic tank with vacuum suction truck and shall be disposed at designated place as approved by the local authorities and as directed by the Engineer In Charge.
Cleaning of Manholes with new bamboo reepers/MS cleaning rods/any other suitable means as directed by the Engineer In Charge.
J SURYANARAYANA
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .