| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.0 LAccepted-AOC PLOT NO D 2 COAL DEPOT FOSBERY ROAD SEWRI E MUMBAI 400 015 | MUMBAI | MUMBAI | MAHARASHTRA | 400015 | ₹32.0 L Quoted ₹32.6 L | L1 | Accepted-AOC BEING ELIGIBLE AND LOWEST BIDDER |
| 2 | L2₹35.6 LRejected-Finance PLOT NO 28 B NAHAR SINGH JI KA HATTA BHATI CIRCLE RATANADA JODHPUR RAJ 342011 | JODHPUR | JODHPUR | RAJASTHAN | 342011 | ₹35.6 L | L2 | Rejected-Finance OTHER THAN THE LOWEST BIDDER |
| Sl No | Description | Qty | Unit | BEYLIM INFRA L2 | K A ELECTRIC CO L1 |
|---|---|---|---|---|---|
| 1.00Material and labour for point wiring for one light point or one fan point or one fan point controlled by one switch with using 1.5 Sq mm (nominal area) stranded copper conductor single core, PVC insulated & unsheathed cable, 1100 volts grade in and incl concealed PVC conduit (medium grade) of suitable size all as specified and directed with using new sunken type pressed steel box/terminal boxes for mounting fittings/junction boxes not less than 1.6 mm thick duly painted with two coats of black bituminous paint over a coat of red oxide primer with and incl all accessories and using 1.5 Sq mm (nominal area) stranded copper conductor single core conductor, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed. Make PVC cable .Havells/Finolex/Polycab Note : (i) The quoted rates shall be deemed to be inclusive foe cutting chases in brick walls/pillars etc for concealing the depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the portion of point wiring at RCC columns/ Beems/ Cielings shall be in surface conduit of suitable size fixed on surface plugs and provision of covering sunken boards/terminal boxes/junction boxes of any shape and size with 3 mm thick with suitable GI screws and cup washers. (ii) Fittings like switches sockets regulators, lamp holders light fittings shall be measured and paid for seperatly of Sch’A’. (iii) The size of conduits shall be determined on permissible No of runs of wires as specified in SSR part I (2010) However minimum size of conduits shall be 20 mm dia (medium grade). | |||||
| 2.00 | One light point/Fan point controlled by one one way switch. | 28 | Point | 850 ₹23,800 | 850 ₹23,800 |
| 3.00 | Socket outlet point 5 Amp on same board. | 4 | Point | 280 ₹1,120 | 280 ₹1,120 |
| 4.00 | One 3 pin socket out let 5 Amps on the independent board. | 7 | Point | 880 ₹6,160 | 880 ₹6,160 |
| 5.00 | Description all as per serial item No. 02 above but with 2.5 sqmm cable for 3 pin 15 Amps switch socket outlet (Power point) complete all as specified. | 7 | Point | 950 ₹6,650 | 950 ₹6,650 |
| 6.00 | S/F switch piano Modular type single pole one way 10 Amp 240 Volts. Make: Havells/Anchor/Plaza | 39 | Each | 200 ₹7,800 | 200 ₹7,800 |
| 7.00 | S/F in repair socket only 6 Amps 2 in 1 Socket with Shutter Modular type 240 Volt.Make: Havells/Anchor/Plaza | 11 | Each | 320 ₹3,520 | 320 ₹3,520 |
| 8.00 | S/F in repair switch piano Modular type single pole one way 16 Amp 240 Volts. MakeHavells/Anchor/Plaza | 7 | Each | 300 ₹2,100 | 300 ₹2,100 |
| 9.00 | S/F in repair socket only 6/16 Amps Twin Socket Modular type 240 Volt.Make: Make: Havells/Anchor/Plaza | 7 | Each | 450 ₹3,150 | 450 ₹3,150 |
| 10.00 | Supply & Fixing wall fan 450 mm 5 star rating metallic white, dust resistant with remote control. | 7 | Each | 3,600 ₹25,200 | 3,600 ₹25,200 |
Updated dates
Tender Value
₹32.6 L
EMD Value
₹65,300
Closing Date
3 Feb 2026, 6:00 pmClosed
GE (AF) BARODA
GE (AF) BARODA ,DARJIPURA , GUJARAT-390022
PROVN OF CERTAIN MINOR WORKS AT AF STN BARODA
2025_MES_742058_2
8139/E8
Open Tender
Electrical and Maintenance Works
180 days
DARJIPURA
AS PER NIT
9 documents required · 9 mandatory
₹500
Yes
GE (AF) BARODA
₹65,300
Yes
17 Feb 2026
13 Jan 2026
5 Feb 2026
13 Jan 2026
3 Feb 2026
20 Jan 2026
One light point/Fan point controlled by one one way switch.
Socket outlet point 5 Amp on same board.
One 3 pin socket out let 5 Amps on the independent board.
Description all as per serial item No. 02 above but with 2.5 sqmm cable for 3 pin 15 Amps switch socket outlet (Power point) complete all as specified.
S/F switch piano Modular type single pole one way 10 Amp 240 Volts. Make: Havells/Anchor/Plaza
S/F in repair socket only 6 Amps 2 in 1 Socket with Shutter Modular type 240 Volt.Make: Havells/Anchor/Plaza
S/F in repair switch piano Modular type single pole one way 16 Amp 240 Volts. MakeHavells/Anchor/Plaza
S/F in repair socket only 6/16 Amps Twin Socket Modular type 240 Volt.Make: Make: Havells/Anchor/Plaza
Supply & Fixing wall fan 450 mm 5 star rating metallic white, dust resistant with remote control.
Supply and fixing LED light fitting recess mounted/pendent mounting ultraslim LED round shape 8'' down light aluminium extruded housing with full opal diffuser IP 20 suitable for perfect lighting condition 20 watt 240 volt, 50 Hz AC supply.
supply and fixing LED security light luminaire 36 watt freedom, pressure die cast aluminum housing, heat resistant glass, IP66 protection, better option for uniform distribution complete all accesaories pre wired and including connecting up with thrre core 1.5 sqmm flexible copper conductor cable from ceiling rose to connector of light complete.
Supply and fixing sheet metal enclosure SP with two pin and socket with one single pole MCB 20 Amps ,'B Curve 240 Volts complete all as specified
S & F MCB DB 8 way sheet metal enclosure SPN 240 volts, 50 Hz, with IP-42 protection, double door with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting complete ncluding taking down old unserviceable all as specified.
Supply and fix MCB, single pole and neutral link (double pole) 240 volts 32 Amps capacity C seriesfixed in DB's.
Supply and fix in repairs MCB, single pole 240 volts 6 to 32 Amps capacity C series fixed in DB's.
M & L for sub main wiring using two single core 6 Sqmm fire retardant PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked drawing in and including PVC Conduit or in concealed conduit(as required & directed by Engr-in-Charge)accessories like bends, tee, etc fix on wall and ceiling and connecting to earth dolly and with 6 Sqmm earth wire, PVC insulated & unsheathed complete including taking down old unserviceable all as directed.Note: (i) Two runs of 6 sqmm and one run of 6 sqmm cable and one run of PVC conduit shall be measured as one RM. (ii) Necessary plastering in the disturbed surface of wall and distempering /white washing to match the existing colour shall be included in the unit rate quoted .
M & L for sub main wiring using two single core 4 Sqmm fire retardant PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked drawing in and including PVC Conduit or in concealed conduit(as required & directed by Engr-in-Charge)accessories like bends, tee, etc fix on wall and ceiling and connecting to earth dolly and with 4 Sqmm earth wire, PVC insulated & unsheathed complete including taking down old unserviceable all as directed.Note: (i) Two runs of 4 sqmm and one run of 4 sqmm cable and one run of PVC conduit shall be measured as one RM. (ii) Necessary plastering in the disturbed surface of wall and distempering /white washing to match the existing colour shall be included in the unit rate quoted .
M & L for sub main wiring using two single core 2.5 Sqmm fire retardant PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked drawing in and including PVC Conduit or in concealed conduit(as required & directed by Engr-in-Charge)accessories like bends, tee, etc fix on wall and ceiling and connecting to earth dolly and with 2.5 Sqmm earth wire, PVC insulated & unsheathed complete including taking down old unserviceable all as directed.Note: (i) Two runs of 2.5 sqmm and one run of 2.5 sqmm cable and one run of PVC conduit shall be measured as one RM. (ii) Necessary plastering in the disturbed surface of wall and distempering /white washing to match the existing colour shall be included in the unit rate quoted .
Supply and fix IP 43 VTPN DB With MCCB Incomer Distribution Board Loadline DBs are fitted with Bus Bars, Neutral Links, Blanking Plates 4 way, 415 volts, 50 Hz, double door with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting with one MCCB as incommer 100 Amps complete all as specified. Make. L & T,Havells/Schneider /Seimens /Legrand. (Note : MCCB SP/TPN shall be measured and paid seperately under appropriate items of this schedule . Note : Copper thimble shall be used for connection of cable .
Supply and fix in repair MCCB four pole 120 Amps 415 Volts breaking capacity 36 KA as per IEC 60947-2 . Make. L & T,Havells/Schneider /Seimens /Legrand .
Supply, laying and testing cable ARMOURED XLPE CABLES (LT) 1.1 KV GRADE XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core
Excavation in trenches not exceeding 1.5 m wide and not exeeding 1.5 m in depth and getting out in soft/loose soil for removing/laying of cable etc as directed by Engineer-In-Charge.
Returning, filling excavated soil in trenches including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each all as directed by Engineer-In-Charge.
Removing surplus excavated soil to a distance not exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point.
M & L for sand cushioning to PVC cable with using clean dry and natural river sand gently punning below/around cable all as specified.
M& L for laying well burnt bricks as in protection of cable laid dry, flat aboutting each other all as specified and directed by Engr-in-charge
Supply and install high speed split units indoor & outdoor units inverter Air conditioner complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with 3 Star rating having minimum EER 3.2 of capacity 2.0 TR operating at 230 V 50 HZ supply complete all as specified and directed
S&F single pole and neutral enclosure with a two pin and earth and metal clad plug socket complete with one single pole MCB 32 Amp 240 Volts complete all as specified and directed by Engineer in Charge
Supply and install high speed split units indoor & outdoor units inverter Air conditioner complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with 3 Star rating having minimum EER 3.2 of capacity 1.5 TR operating at 230 V 50 HZ with all fitting such as single phase electric driven compressor, copper condensing fan motor, condenser with fixing of stand on wall including excess copper tubing if required beyond the length supplied with AC unit , PVC conduit of 15mm dia not exceeding 2.5 mtr long for water drain and making good to disturbed surface with cement mortar 1:3 including testing and all necessary controls and accessories all as specified and directed by Engr-in-charge.
M&L for earthing complete with copper earth plate electrode size 900 x 600 x 5.00 mm thick buried directly in ground vertically in a pit of depth not less than 3.30 mtr below ground level connected to copper strip 32 x 6 mm as earth lead by brass nuts and bolts washer including brazing the copper strip with copper plate as shown in elecrical plate no 03 connected to earth test point including necessary excavation in any type of soil, filling charcoal and salt around the plate in layers, filling the pit with agriculture soil free from stones, to bring from outside defence land, and to be mixed with and including bentonite - 03 bags of 25 Kg each for each pit, construction of PCC earth pit chamber, RCC chamber cover plate, wiremesh, funnel, test point, 40 mm dia GI protection pipe light grade and 32 mm GI medium perforated pipe for watering etc complete and testing on completion. The Plate and strip shall be of copper as per IEC 62561-2, composition all as specified and directed.
Note:- (a) Fresh agriculture soil will be used for filling the dug as required to achieve the desired resistance from out side. (b) Contractor has to provide bentonite - 03 Bags ( each bag of 25 Kg) to mix with fresh agriculture soil in each earth pit to achieve desired resistance value of less than 01 Ohms (c) Copper strip to be laid below 100mm ground level and connectd to test point through plinth protection. (d) Necessary cost of repair to plith protection and connected plate and earth continuity conductor through double nuts bolts and blazing of joints, agriculture soil to be brought from outside deemed to be included in item rate (e) Copper strip upto 7.5 Mtr will be included in item rate. (f) Contractor to clear the site and dispose off the excavated materilals from site as directed (g) On testing after completion if the earth resistance of less than 01 Ohms if not obtainded, earthing will rejuvenated at no extra cost till the desired earth resistance is obtained.
M&L for earthing complete with copper earth plate electrode size 600 x 600 x 3.0 mm thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanized copper strip 20 X 3 mm earth lead by means of bolts, nuts, check nuts and washers of copper and GI pipe light grade 20mm dia bore for watering funnel with wire mesh. CI cover with frame, PCC chamber pit with PCC 1:3:6 type C-2 excavation and earth work all as shown in electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion. The Plate and strip shall be of copper as per IEC 62561-2, composition complete all as specified and directed. Note: On testing after completion if the earth resistance of less than 03 Ohms if not obtainded, earthing will rejuvenated at no extra cost till the desired earth resistance is obtained.
Supply and fix tubes light grade with all fittings 40 mm dia for protection incld fixing materials by inserting copper strip along roof and wall complete all as specifeid and directed
M&L for Copper strip 20 x 3.0 mm with saddles and fixing screws etc. for roof conductors with saddles and fixing screws etc. for roof conductors and down conductors above ground for roof conductors and down conductor above ground complete all as specified and directed
M&L Test point terminal block enclosed in MS Sheet Box of 20 Guage, made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screwfor Copper strip 20 x 3.0 mm with saddles and fixing screws etc. for roof conductors with saddles and fixing screws etc. for roof conductors and down conductors above ground for roof conductors and down conductor above ground complete all as specified and directed
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sqmm 3.5core complete all as specified and as directed.
Supply and laying unreinforced cable cover of size 250x150x40mm peak size as in protection of cable laid dry, flat abutting each other width wise all as directed by Engineer-in-Charge
M & L for Cutting out of hard standing, concrete blocks, slabs, brickwork or stone masonry (in alternate course), forming toothings for and bonding new work in mortar into old work, including new materials with complete and making good to the disturbed surface by using PCC of C1, 20 mm Grade 1:3:6 up to the depth for laying of water pipe line in soil complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate 600x600x6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised iron strip 32x6 mm dia as earthing lead by means of bolts, nuts, check-nuts, and washers of galvanised iron or steel besides welding at all joints as shown in drawings and including excavation and earth work, GI pipe light grade 50 mm bore for protection of GI strip from earth electrode to and including the earth test point of galvanised Iron/steel . supplying and laying charcoal stone aggregate) chamber and RCC cover of size 54x54x50 mm (1:2:4) type B1 using 20 mm graded crushed stone aggregate reinforced with 8 mm dia TMT bars @ 75mm C/C both ways with mild steel handle 12 mm dia, PGI funnel with wire mesh, 20 mm dia GI pipe light grade for watering all as specified and directed.
Supply and fixing MCB DB 4 way vertical sheet metal enclosure TPN 415 volts, 50 Hz, with IP-43 protection, double door with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting with one MCB as incommer complete all as specified and directed. Notes : (i) MCB SP/TP shall be measured and paid seperately under appropriate items of this schedule (ii) Copper thimble shall be used for connection of cable .
S & F MCB 100 Amp suitable for TPN DB complete all as specified and as directed.
S & F MCB SP uo to 40 amp suitable for TPN DB complete all as specified and as directed.
M&L for GI tubing 100mm light grade for protection of cable/pipe line complete all as specified and as directed.
Supply and fix air termination single pointed aluminium rod, 12mm dia, 300mm long including all fittings, fixtures and PCC 1:2:4 type B-1 blocks 100mm x 100mm x 100mm complete all as specified and directed
M & L GI strip 32 mm x 6 mm complete with burried in ground
M & L Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and and down conductors above ground
Supply and fix air termination single pointed copper rod, 12mm dia, 300mm long complete.
M&L for earthing complete with copper earth plate electrode size 300 x 300 x 3.15 mm thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of earthhencing chemical compound . Chemical should be tested and certified by any international accredited laboratory. The earthhencing compound should be tested referring to protocol IS 1350/&/EC62321/111/54/CDV. The PH value of compound should be between 7 to 8. The content of mercury (Hg) & Hexacromium should be below detection level and electrode connected to and including galvanized copper strip 20 X 3 mm earth lead by means of bolts, nuts, check nuts and washers of copper and GI pipe light grade 20mm dia bore for watering funnel with wire mesh. CI cover with frame, PCC chamber pit with PCC 1:3:6 type C-2 excavation and earth work all as shown in electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion.
Earth continuty conductor or main earthing strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to pole or any other indicated situation for loop earthing strip of size 32x6 mm complete all as specified and as directed.
Supply and fix Voltage stablizer for automatic opretion, three phase, naturally oil cooled, indoor type & designed for input variation between 300 volt to 480 volt with out put vol stablized at 415 V with accurcy +- 2.5% and speed of correction 8 volt per second and of cap 50KVA cmplete all as specified and as directed.
Supply and fixing MCB DB 4 way vertical sheet metal enclosure VTPN 415 volts, 50 Hz, with IP-43 protection, double door with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting with one MCB as incommer complete all as specified and directed.
S & F MCCB 100 Amp suitable for TPN DB complete all as specified and as directed.
S & F MCB SP uo to 40 amp suitable for TPN DB complete all as specified and as directed.
S & F MCB SPN uo to 63 amp suitable size complete all as specified and as directed.
S & F copper cable 25 Sqmm single core suitable for stablizer connection complete all as specified and as directed.
Note for all items :- If any item gets repeated in this schedule, the lowest rate quoted for those same items by the L-1 bidder shall be considered for payment and decision of Accepting Officer i.e. GE(AF) Baroda in this regard shall be final and binding.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
BOQ_837963.xls
BOQ • 0.33 MB
8139PS.pdf
Tender Documents • 0.84 MB
Download all tender documents and submit your bid