Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.9 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹27.3 L+₹41,520 (1.54%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹27.6 L+₹66,015 (2.45%)Rejected-Finance ROWRIAH KB ROAD PO CHALIHA JORHAT 785004 ASSAM | JORHAT | JORHAT | ASSAM | 785004 | L3 | Rejected-Finance Other than L1 |
Tender Value
₹24 L
EMD Value
₹48,000
Closing Date
14 Apr 2021, 6:00 pmClosed
GE AF JORHAT
GE AF JORHAT
MANNING AND OPERATION OF BOILER DG SETS AND COMPREHENSIVE MAINT OF MECHANIZED LAUNDRY PLANT AND ITS ACCESSORIES AT AFH JORHAT UNDER GE AF JORHAT
2021_MES_431269_1
8865/E8
Open Tender
Miscellaneous Services
Works
335 days
GE AF JORHAT
As per NIT
11 documents required · 11 mandatory
₹500
GE AF JORHAT
₹48,000
Yes
27 May 2021
17 Mar 2021
16 Apr 2021
17 Mar 2021
14 Apr 2021
24 Mar 2021
Amount
Manning & Opeation and comprehensive maintenance of following DG Sets including acessories like AMF Panel, Battery etc at 5 AFH Power House along with installed switch gear to operate as and when required to keep continious electric supply round the clock in THREE SHIFTS (OF 8 HOUR EACH) WITH ONE SKILLED OPERATOR FGM PER SHIFT including minor spare parts complete all as specefied and as directed by Engineer-in-Charge. LIST OF DG SET/ EQUIPMENT INSTALLED AT POWER HOUSE AF HOSPITAL:- (a) 320 KVA DG Set -01 SET (b) 100 KVA DG Set -01 SET (c) CHANGE OVER SWITCH etc.
Manning & Opeation of Main Power House of 5AFH alongwith necessary operation of the following equipments including accessories like AMF Panel, Battery etc as and when required to keep continious electric supply round the clock in THREE SHIFTS OF 8 HOUR WITH Electrician (SK) PER SHIFT PER LOCATION including necessary day to day maintenance and attending daily electric supply complaints at 5 AFH in all respect, routine maint, servicing, testing to attending external/ internal electric breakdown and repair complete all as specified and as directed by Engineer-in-Charge. LIST OF EQUIPMENT INSTALLED AT SURGICAL SUB STN 5AFH :- (a) 11 KV VCB 800 Amps -01 SET (b) 630 KVA Transformer -01 SET (c) LT PANEL BOARD -07 Nos (d) AMF PANEL BOARD -04 Nos (e) LT ACB -01 No. (f) 630 KVA VOLTAGE STABILIZER -01 No. (g)APFC PANEL BOARD 300KVAR -01 No. (h) CHANGE OVER SWITCH etc.
Manning & Opeation and comprehensive maintenance of following DG Sets including acessories like AMF Panel, Battery etc. at 5AFH Mechanized Laundry along with installed switch gear to operate as and when required along with installed Machinery etc. including comprehensive maintenance in FOR SINGLE SHIFT OF 8 HOURS duration (0700 HOURS TO 1500 HOURS) with one skilled operator (FGM) per day including daily checking of all Electrical and Mechanical parts complete all as specified and as directed by Engineer-in-charge. LIST OF DG SET/ EQUIPMENT INSTALLED AT MECHANICAL LAUNDARY & MEDICAL GAS PLANT:- (a) 125 KVA DG SET -01 SET (b) MEDICAL GAS PLANT -02 Nos (c) WASHER CUM EXTRACTOR -03 SET (d) DRYING TUMBLER -02 SET (e) BED PRESS MACHINE -02 Nos. (f) CALENDERING MACHINE -02 Nos. (g) SLUICING MACHINE -02 Nos. (h) AMF PANEL BOARD - 02 Nos. (j) APFC PANEL BOARD 30KVAR -01 Nos. (k) CHANGE OVER SWITCH etc.
Manning & Opeation of Boiler No. 1, 2, & 3 in SINGLE SHIFT OF 8 HOURS duration (0700 HOURS TO 1500 HOURS) with one skilled operator (FGM) per day and carrying out comprehensive maintenance/repair works of Boiler No. 1, 2 & 3 as and when required through manufacturer's authorised agency and as per manufacturer's maintenance schedule to maintain its serviceability and ensure smooth functioning, complete all as specified and as directed by Engineer-in-charge.
NOTE FOR SCH 'A' : FOR ITEM NO. 1, 2, 3 AND 4 :- (a) Contactor have to provide Grease, Gland and Gasket, Consumable Materials such as Soap,Cotton Waste, Protective clothing, Gloves and Necessary Tools for Electrician and FGM which are required for maintenance, maining and Operation of installation from his own arrengements and sources for which cost of same shall deem to be included in the UNIT RATE. NO Extra AMOUNT shall be PAID separately on this account. (b) Daily Cleaning and maintenance of DG Set & Mechanical Laundary and respective areas of installation shall be carried out as specified. (c) Qualifications, Licenses, etc. of Operator/Staff(s) shall be submitted to Engineer-in-charge for verification and approval. However Accepting Officer may stop services of any Operator/Staff(s) of the contractor if found unsatisfactory for the job. (d) The Contactor shall be responsible for MAKING GOOD damage occoured due to inadequate experience of staff employed by him and/or negligence of his workmen.
(e) Fuel and lubricants shall be issued by the department under SCHEDULE 'B' as 'Free for filling, which shall be collected from AGE E/M Stores. (f) SPARES shall be measured and paid separately in respective Item(s) of BOQ here in after. (g) The following documents shall be maintained by the contractor and produced as and when required:- (i) Printed log sheet as per sample (ii) Duty roster. (iii) Daily attendance register (iv) Material register (v) Maintenance register
Supply & Fixing in repair Power Contactor 4 Pole, 40 Amps, AC 415 Volt with auxilary contact suitable for Mechanizedl Laundry Equipments/Boilers), complete all as specified and as directed by Engineer-in-charge. Make : BCH (Cat No : N1N) or equivalent model in L&T/Seimens/ABB.
Supply & Fixing in repair Power Contactor 4 Pole, 25 Amps, AC 415 Volt with auxilary contact suitable for Mechanizedl Laundry (Equipments/Boilers), complete all as specified and as directed by Engineer-in-Charge. Make : BCH (Cat No : N0N) or equivalent model in L&T/Seimens/ABB.
Supply & Fixing in repair Power Contactor 3 Pole, 32 Amps, AC 440 Volt suitable for Mechanizedl Laundry (Equipments/Boilers), complete all as specified and as directed by Engineer-in-Charge. Make: BCH (Cat No: CE15FN3 B) or equivalent model in L&T/Seimens/ABB.
Supply & fxing in repair over load release valve suitable for Mechanized Laundry (Equipments/Boilers), complete all as specified and as directed by Engineer-in-Charge. Make: L&T or equivalent as approved.
Supply & Fixing in repair Thermal Over Load Relay, (range of 1.4-2.3 Amps) suitable for Mechanized Laundry (Equipments/Boilers), complete all as specified and as directed by Engineer-in-Charge. Make: L&T (Cat No: SS94141OOPO) or equivalent model of SIEMENS/BCH.
Supply & Fixing in repair Thermal Over Load Relay, (range of 2-3.3 Amps) suitable for Mechanized Laundry (Equipments/Boilers), complete all as specified and as directed by Engineer-in-Charge. Make: L&T (Cat No : SS94141OOQO) or equivalent model of SIEMENS/BCH.
Supply & Fixing in repair Time Delay Relay (Electronic type) for 3-30 Sec, suitable for Mechanized Laundry (Equipments/Boilers), complete all as specified and as directed by Engineer-in-Charge. MAKE: L&T(Cat No: ST80328OOOO) or equivalent model of SCHNEIDER/BCH.
Supply & Fixing in repair Rotary Switch, 16 Amps, 3 pole, 440 Volt, suitable for Mechanized Laundry (Equipments/Boilers), complete all as specified and as directed by Engineer-in-Charge. MAKE : L&T (Cat No : 61027) or equivalent model of SCHNEIDER / BCH.
Supply & Fixing in repair Solenoid Valve 230 Volt AC suitable for Mechanized Laundry (Equipments/Boilers), complete all as specified and as directed by Engineer-in-Charge. MAKE : LUTHRA (Cat No : 11724713) or equivalent as approved.
Supply & Fixing in repair V Belt No. B – 37 suitable for Mechanized Laundry (Equipments/Boilers), complete all as specified and as directed by Engineer-in-Charge. MAKE : ROULUNDS/ FENNER/ DUNLOP/NIRLON.
Supply & Fixing in repair V Belt No. B – 42 suitable for Mechanized Laundry (Equip-ments/Boilers), complete all as specified and as directed by Engineer-in-Charge. MAKE : ROULUNDS/FENNER/ DUNLOP/NIRLON.
Supply & Fixing in repair V Belt No. B – 50 suitable for Mechanized Laundry (Equip-ments/Boilers), complete all as specified and as directed by Engineer-in-Charge. MAKE : ROULUNDS/ FENNER/ DUNLOP/NIRLON.
Supply & Fixing in repair V Belt No. B – 53 suitable for Mechanized Laundry (Equip-ments/Boilers), complete all as specified and as directed by Engineer-in-Charge. MAKE : ROULUNDS/FENNER/ DUNLOP/NIRLON.
Supply & Fixing in repair V Belt No. B – 54 suitable for Mechanized Laundry (Equip-ments/Boilers), complete all as specified and as directed by Engineer-in-Charge. MAKE : ROULUNDS/FENNER/ DUNLOP/NIRLON.
Supply & Fixing in repair V Belt No. B – 82 suitable for Mechanized Laundry (Equip-ments/Boilers), complete all as specified and as directed by Engineer-in-Charge. MAKE : ROULUNDS/FENNER/ DUNLOP/NIRLON.
Supply & Fixing in repair V Belt No. B – 83 suitable for Mechanized Laundry (Equip-ments/Boilers), complete all as specified and as directed Engineer-in-Charge. MAKE : ROULUNDS/FENNER/ DUNLOP/NIRLON.
Supply & Fixing in repair V Belt No. B – 96 suitable for Mechanized Laundry (Equip-ments/Boilers), complete all as specified and as directed Engineer-in-Charge. MAKE : ROULUNDS/FENNER/ DUNLOP/NIRLON.
Supply & Fixing in repair V Belt No. B – 120 suitable for Mechanized Laundry (Equipments/Boilers), complete all as specified and as directed by Engineer-in-charge. MAKE : ROULUNDS/FENNER/DUNLOP/NIRLON.
Supply & Fixing in repair V Belt No. C – 116 suitable for Mechanized Laundry (Equipments/Boilers), complete all as specified and as directed by Engineer-in-charge. MAKE : ROULUNDS/FENNER/DUNLOP/NIRLON.
Supply and fix Mild Steel Pipe, heavy grade, 25mm inner dia for steam pipe, winding with asbestos rope 1/2" dia and taking joints from existing steam pipes by providing flanges, bolt nuts, washers, hanging bolts etc. of suitable sizes including cutting, taking out unserviceable steam pipes, complete all as specified and as directed by Engineer in charge. Make: TATA / JINDAL / PRAKASH
Supply & Fixing in repair Steam Pressure Switch suitable for Mechanized Laundry Boilers complete all as specified and as directed Engineer-in-Charge. MAKE : THERMAX CAT PART No. 8441133500 or equivalent as approved.
Supply & Fixing in repair Water Pressure Switch suitable for Mechanized Laundry Boilers complete all as specified and as directed Engineer-in-Charge. MAKE : THERMAX CAT PART No. 8441133200 or equivalent as approved.
Cleaning of sub station/ E/M installations including cutting of bushes and grasses and levelling of soils all as directed by Engineer-in-charge.
Supply & Fixing in repair Gun Metal Gate Valve 25mm dia suitable for Mechanized Laundry (Equipments/Boilers) complete all as specified and as directed by Engineer-in-Charge. MAKE : ZOLOTO / LEADER/ KIRLOSKAR.
Supply & Fixing in repair Gun Metal Gate Valve 40mm dia suitable for Mechanized Laundry (Equipments/Boilers) complete all as specified and as directed by Engineer-in-Charge. MAKE : ZOLOTO / LEADER/ KIRLOSKAR.
Supply & Fixing in repair Steam Globe Valve 25mm suitable for Mechanized Laundry (Equipments/Boilers) complete all as specified and as directed by Engineer-in-Charge. MAKE : ZOLOTO / LEADER / KIRLOSKAR.
Supply & Fixing in repair Steam Globe Valve 40mm suitable for Mechanized Laundry (Equipments/Boilers) complete all as specified and as directed by Engineer-in-Charge. MAKE : ZOLOTO / LEADER / KIRLOSKAR.
Supply fixing and testing steam coil assembly suitable for boiler model RXA-04 of THERMAX make (Part No -0312143420) with and including necessary in and out connections including taking out unserviceable coil complete all as specified and as directed by Engineer-in-charge.
M&L for painting of washer cum extractor, drier, slucing machine, clading machine, compressor, etc. of mechanical laundry with two coat of synthetic enamel paint of approval quality with spray painting after removal of old paint, complete all as specified and as directed by Engineer-in-charge. Make - Asian/Berger/Nerolac.
Dismantling Electric Driven 3 Phase 415 Volt, 50 Hz, Squirrel Cage Induction Motor, 3.0 HP Capacity and Taking Out complete Burnt out Winding from the Stators slots including Cleaning the Slots and Rewinding the stators of the Motor by Super Enamelled Copper Wire suitable size and quantity, incuding provisioning of all connected winding materials and replacement of unserviceable bearing as per existing specification, Re-assembling and testing , complete all as specified and as directed by Engineer-in-Charge.
Dismantling Electric Driven 3 Phase 415 Volt, 50 Hz, Squirrel Cage Induction Motor, 5.0 HP Capacity and Taking Out complete Burnt out Winding from the Stators slots including Cleaning the Slots and Rewinding the stators of the Motor by Super Enamelled Copper Wire suitable size and quantity, incuding provisioning of all connected winding materials and replacement of unserviceable bearing as per existing specification, Re-assembling and testing , complete all as specified and as directed by Engineer-in-Charge.
Dismantling Electric Driven 3 Phase 415 Volt, 50 Hz, Squirrel Cage Induction Motor, 15.0 HP Capacity and Taking Out complete Burnt out Winding from the Stators slots including Cleaning the Slots and Rewinding the stators of the Motor by Super Enamelled Copper Wire suitable size and quantity, incuding provisioning of all connected winding materials and replacement of unserviceable bearing as per existing specification, Re-assembling and testing, complete all as specified and as directed by Engineer-in-Charge.
M&L for Limit switch for Mechanized laundry Boiler, complete all as specified and as directed by Engineer-in-Charge. Make - Thermax type LS-100-10A 500V or equivalent as approved.
Labour only for servicing of Boiler of capacity 50 Kg /hr including cleaning of steam coil burner assembly and fuel line assembly of the boiler Model RXA -04 type (Make : THERMAX) installed at Mechanized laundry and re-fixing and testing burner assembly complete all as specified and directed by Engineer in charge. Note:- Minor Spare parts deemed to be included in quoted unit rates except those mentioned here-in-after.
Supply and Fixing following materials for boiler of capacity 50 Kg/hr of Make : THERMAX (Model : RXA-04) including taking down unserviceable one complete all as specified and as directed by engineer-in-charge.
Photocell 8209 (Part No 860311200)
Sequence controller MA 55 (Part No 5605113300)
Burner rod - E2 type (Part No 03147578)
Ignition electrode (Part No 8625111300)
Ignition transformer 14.5 KVA 415 Volt (Part No 8606111100)
Electrode Cap (Part No 86000000000)
High tension wire 5 meter long (Part No - 0034121100)
Packing hylum for photcell mount (Part No 0314540001)
Packing asbestos for photocell base (Part No 0114121000)
Cap for photocell mount (Part No 01141120601)
Sight glass dia 50 mm (Part No 0114120500)
Taking out defective fuel line assembly of boiler and supply and fix for new unit of fuel line assembly consisting of the following items with and including in and out connection complete all as specified and directed by Engineer-in-charge. Items of fuel line assembly :- (a) Fuel pump -E 6 NB(Part No - 8260020000) -01 Nos. (b) Pressure gauge 0-40 Kg/Sq cm (part No 8451131100)- 01 Nos. Make : THERMAX, Model No RXA -04.
Supply and fixing asbestos rope 1/2" dia by binding over steam pipe including removing of old unserviceable rope complete all as specified and as directed by Engineer-in-charge.
Supply and fixing shock absorber for washer cum extractor capacity 50 KG/Hr including taking out old unserviceable shock absorber, complete all as specified and as directed by Engineer-in-Charge.
Preperation of surfaces of boiler's chimneys by removing scrapping and cleaning old paints/rusts/dirts etc and applying two coats of heat resistant paint as per manufacture using spray gun complete all as specified and as directed Engineer-in-Charge.
S & F single phase preventor suitable for 3 phase 5 to 15 HP induction motor 415 Volt, complete all as specified and as directed by Engineer-in-Charge. Make - ABB/BCH/L&T.
Supply & Fixing in repair bearing No 6307 (as per sample or as approved) suitable for Mechanized laundry eqpt, complete all as specified and as directed by Engineer-in-Charge. Make : Tata/SKF/NBC
Supply & Fixing in repair bearing No 6310 (as per sample or as approved) suitable for Mechanized laundry eqpt, complete all as specified and as directed by Engineer-in-Charge. Make : Tata/SKF/NBC
Supply & Fixing in repair bearing No 6312 (as per sample or as approved) suitable for Mechanized laundry eqpt, complete all as specified and as directed by Engineer-in-Charge. Make : Tata/SKF/NBC
Supply & Fixing in repair bearing No 6316 (as per sample or as approved) suitable Mechanized laundry eqpt, complete all as specified and as directed by Engineer-in-Charge. Make : Tata/SKF/NBC
Supply & Fixing in repair bearing No 6320 (as per sample or as approved) suitable for Mechanized laundry eqpt, complete all as specified and as directed by Engineer-in-Charge. Make : Tata/SKF/NBC
M&L for cleaning steam coil of boiler having capacity 400 Kg/Hrs with maxiline-05 (Approx 12.5 Kg) chemical by using 2.0 HP mono block pump and necessary arrangement for cleaning/ removing of deposited scales inside the coil complete including dismantiling taking down the coil from boiler and reinstalling after cleaning testing complete all as specified and as directed by Engineer-in-Charge
Supply & Fixing in repair Loaded spring for Washer cum extractor (as per sample approved) suitable for Mechanized laundary, complete all as specified and as directed by Engineer-in-Charge. Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ.
M/S SANTOSHI TRADERS
M/S DHAR AND DHAR
Bidder Name
THE SUPPLY AGENCY
M/S DHAR AND DHAR
M/S SANTOSHI TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .