| 1 | L1₹53.7 LAccepted-AOC | L1 | Accepted-AOC Below Rate | |
| 2 | L2₹56.4 L+₹2.7 L (5.10%)Rejected-AOC 184 KEELA STREET NEIKULAM NEDUNGUR LALGUDI 621105 | TIRUCHIRAPPALLI | TAMIL NADU | 621105 | L2 | Rejected-AOC Above rate |
| Sl No | Description | Qty | Unit | A S POWER SOLUTIONS L1 | ASV CONSTRUCTION L2 |
|---|---|---|---|---|---|
| 1.00Electromagnetic Flow Meter shall be a velocity sensing Electromagnetic type, microprocessor based signal converter, sealed housing, flanged tube meter for 1.0 Mpa working pressure, manufactured to highest standard available for mag-meters, equipped with minimum six digit digital totalizers, reading in units of (kilolitres/ cubicmeter) and shall be accurate within 0.5% of Measured value, shall operate within a range of 0.3m/sec to 4 m/sec and be constructed as follows:Meter tube (Sensor) shall be fabricated from stainless steel tube and use class PN10 flat face carbon steel flanges in accordance with IS 1538. These flanges shall be welded to the flow tube. The internal and external of the meter tube shall be blasted to near white and lined with hard rubber/ Polyurethrene/ PTFE preferably by SBR or EPDM. Meter tube shall have a constant nominal inside diameter offering no obstruction to the flow. The accuracy should be inclusive of linearity, hysteresis, repeatability, temperature and pressure effects Coil Housing shall be fabricated from stainless steel (SS 304) with Anticorrosive paint for corrosion resistance and welded to the tube providing a completely sealed environment for all coils, electrode connections and wiring harness capable of submerged or buried operation with IP 68 protection. Signal Converter shall be pulsed DC coil excitation type with auto zeroing. The signal converter shall be remotely mounted away from the meter. The converter shall indicate direction of flow and provide a flow rate indication and a total of flow volume for both forward and reverse directions.The converter shall provide an isolated 4-20 mA output into minimum 500-ohm load and a frequency output of a maximum of 0-10 KHZ and a scaled pulse output, Communication interface is RS485, HART output, . The microprocessor based signal converter shall have a self-diagnostic test mode and a backlit display that continuously displays “Rate of Flow” and “Total Volume”. Converter shall be supplied with a programmable low flow drop out Higher flow and empty pipe zero return. The signal converter housing should be die-cast aluminium with glass window. The converter cum transmitter should be fully programmable form the front facia. The programming should be user friendly, self-prompting menu driven. Flowmeter test calibration certificate from FCRI, flow test lab/ NABL accredited lab to be furnished | |||||
| 1.01 | 100 mm dia | 1 | No | 1,04,306 ₹1,04,306 Lowest | 1,09,525 ₹1,09,525 |
| 1.02 | 150 mm dia | 1 | No | 1,22,138 ₹1,22,138 Lowest | 1,28,250 ₹1,28,250 |
| 1.03 | 200 mm dia | 2 | Nos | 1,51,665 ₹3,03,330 Lowest | 1,59,250 ₹3,18,500 |
| 1.04 | 300 mm dia | 4 | Nos | 2,14,408 ₹8,57,632 Lowest | 2,25,130 ₹9,00,520 |
| 1.05 | 450 mm dia | 2 | No | 3,71,426 ₹7,42,852 Lowest | 3,89,998 ₹7,79,996 |
| 2.00 | Manufacturing and supply of MAIN MV PANEL. Indoor Cubical
Floor mounting type made out of 16 gauge CRCA Sheet with
Siemens grey powder coated. Size:L 2950 x D 1100/550 x H
1975 (1900+75mm) Base frame : 75 x 40 x 6mm Channel with
Block Colour Powder coaded. The panel will comprising of :
EB INCOMER-01:-
630A 4P 50KA, MDO ACB with Microprocessor Based SR18G
Release -1No, E/F Relay, Shunt Coil,UV Coil, RYB, ON/OFF
/Trip Indicator, Digital Multifunction Meter, Mechanical
Interlock, 1000/5A CT, 6A/10A Control MCB with necessary
control wiring.
OUTGOING:-
1. 125A FP 25KA MCCB -1No
2. 250A FP 25KA MCCB -1No
4. 400A FP 36KA MCCB -4Nos
Each MCCB having Extended Rom & Spreader Terminal will be
provided.
BUSBAR SIZE:- Phase 2Rx50x10mm Alu Flat. Neutral:
1Rx50x10mm Alu Flat. Earthing: 1Rx40x10mm Alu Flat with
Colour coded heat shrinkable sleeves. | 1 | Nos | 11,90,104 ₹11,90,104 Lowest | 12,49,610 ₹12,49,610 |
| 3.00 | Supply and delivery of 60 KVAR Automatic Power Factor Capacitor Panel as directed by the departmental officers. | 1 | Nos | 1,34,932 ₹1,34,932 Lowest | 1,41,680 ₹1,41,680 |
| 4.00 | Removal of the existing old panel in MELAMAYANUR Including connected accessories and crane hire charges, transporting charges and hand over the removed matrials to head water works stores.etc. complete | 1 | No | 20,081 ₹20,081 Lowest | 21,100 ₹21,100 |
| 5.00 | Erection testing and commissioning of MV panel. Indoor Cubical floor mounting type including welding machine cutting set and as directed by the departmental officers . | 1 | No | 20,080 ₹20,080 Lowest | 21,100 ₹21,100 |
Tender Value
₹64.5 L
EMD Value
₹64,500
Closing Date
4 Sept 2025, 3:00 pmClosed
Commissioner
Azad Road Karur
Supply, delivery, testing and commissioning of 2000LPM x 40M Head Open well Submersible pump set at vangapalayam and Kulathupalayam, Supply, delivery at Melamayanur HW , Vangal HW, Kulathupalayam and vangapalayam Sump for karur corporation
2025_MAWS_599044_1
E1/3312/2025
Open Tender
Civil Works
Item Rate
180 days
KCMC
Refer Tender Documents
3 documents required · 3 mandatory
₹0
₹64,500
29 Nov 2025
30 Aug 2025
4 Sept 2025
30 Aug 2025
4 Sept 2025
30 Aug 2025
30 Aug 2025 - 4 Sept 2025
Amount
Electromagnetic Flow Meter shall be a velocity sensing Electromagnetic type, microprocessor based signal converter, sealed housing, flanged tube meter for 1.0 Mpa working pressure, manufactured to highest standard available for mag-meters, equipped with minimum six digit digital totalizers, reading in units of (kilolitres/ cubicmeter) and shall be accurate within 0.5% of Measured value, shall operate within a range of 0.3m/sec to 4 m/sec and be constructed as follows:Meter tube (Sensor) shall be fabricated from stainless steel tube and use class PN10 flat face carbon steel flanges in accordance with IS 1538. These flanges shall be welded to the flow tube. The internal and external of the meter tube shall be blasted to near white and lined with hard rubber/ Polyurethrene/ PTFE preferably by SBR or EPDM. Meter tube shall have a constant nominal inside diameter offering no obstruction to the flow. The accuracy should be inclusive of linearity, hysteresis, repeatability, temperature and pressure effects Coil Housing shall be fabricated from stainless steel (SS 304) with Anticorrosive paint for corrosion resistance and welded to the tube providing a completely sealed environment for all coils, electrode connections and wiring harness capable of submerged or buried operation with IP 68 protection. Signal Converter shall be pulsed DC coil excitation type with auto zeroing. The signal converter shall be remotely mounted away from the meter. The converter shall indicate direction of flow and provide a flow rate indication and a total of flow volume for both forward and reverse directions.The converter shall provide an isolated 4-20 mA output into minimum 500-ohm load and a frequency output of a maximum of 0-10 KHZ and a scaled pulse output, Communication interface is RS485, HART output, . The microprocessor based signal converter shall have a self-diagnostic test mode and a backlit display that continuously displays “Rate of Flow” and “Total Volume”. Converter shall be supplied with a programmable low flow drop out Higher flow and empty pipe zero return. The signal converter housing should be die-cast aluminium with glass window. The converter cum transmitter should be fully programmable form the front facia. The programming should be user friendly, self-prompting menu driven. Flowmeter test calibration certificate from FCRI, flow test lab/ NABL accredited lab to be furnished
100 mm dia
150 mm dia
200 mm dia
300 mm dia
450 mm dia
Manufacturing and supply of MAIN MV PANEL. Indoor Cubical Floor mounting type made out of 16 gauge CRCA Sheet with Siemens grey powder coated. Size:L 2950 x D 1100/550 x H 1975 (1900+75mm) Base frame : 75 x 40 x 6mm Channel with Block Colour Powder coaded. The panel will comprising of : EB INCOMER-01:- 630A 4P 50KA, MDO ACB with Microprocessor Based SR18G Release -1No, E/F Relay, Shunt Coil,UV Coil, RYB, ON/OFF /Trip Indicator, Digital Multifunction Meter, Mechanical Interlock, 1000/5A CT, 6A/10A Control MCB with necessary control wiring. OUTGOING:- 1. 125A FP 25KA MCCB -1No 2. 250A FP 25KA MCCB -1No 4. 400A FP 36KA MCCB -4Nos Each MCCB having Extended Rom & Spreader Terminal will be provided. BUSBAR SIZE:- Phase 2Rx50x10mm Alu Flat. Neutral: 1Rx50x10mm Alu Flat. Earthing: 1Rx40x10mm Alu Flat with Colour coded heat shrinkable sleeves.
Supply and delivery of 60 KVAR Automatic Power Factor Capacitor Panel as directed by the departmental officers.
Removal of the existing old panel in MELAMAYANUR Including connected accessories and crane hire charges, transporting charges and hand over the removed matrials to head water works stores.etc. complete
Erection testing and commissioning of MV panel. Indoor Cubical floor mounting type including welding machine cutting set and as directed by the departmental officers .
Erection testing and commissioning of 60KVAR Panel Indoor Cubical floor mounting type including welding machine cutting set and as directed by the departmental officers .
Jointing the C.I/ D.I Double flanged pipes and specials with rubber insertion to with IS-638(1979) and M.S. bolts and nuts of IS 1364-1 (2002), including cost of jointing materials such as bolt and nuts Rubber insertion and labour charges etc., complete.
100 mm dia & air valve
150 mm dia
200 mm dia
300 mm dia
450 mm dia
Supply and delivery of 100 mm dia Kinetic Air Valves For Handling More Volumes Of Air In Pumping Main, Double Orifice Kinetic Air Valve Confirming To Is 14845 Tamper Proof Design (Pn-1) And With 5 Years Warranty
Dewatering using 3HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete.
Erection of 100 mm dia Kinetic Air Valves In Pumping Main, JCB for earthwork including diesel, oil and labour charges and as directed by the departmental officers .
150 mm dia
200 mm dia
300 mm dia
450 mm dia
Erection testing and commissioning of Electromagnetic Flow Meter shall be a velocity sensing Electromagnetic type, including welding machine cutting set and as directed by the departmental officers
100 mm dia
150 mm dia
200 mm dia
300 mm dia
450 mm dia
Supply and delivery of Open well Submersible pump set conforming to IS 14220 /2002 and as amended thereafter and BEE 3 Star Rated capable of discharging the following duties due to all causes. The pump shall be with stainless steel shaft and dynamically balanced bronze mixed type impeller, CI FG 200 grade casing and brass screws and rotor shall be of copper rod as per IS 613/1984 with ISI mark. The pump suitable for installation in sump with 1.1KV grade 3 core suitable copper flat submersible cable to a length of 15m with necessary cable joints. The non-return valve located at the top of the pump in the discharge outlet connection is to be designed with minimum friction. The pump should be directly coupled to 2880 RPM, three phase, 50 Hz (±5), 415V+6% & 415V-15% squirrel cage induction motor suitable for DOL upto 5 HP, Fully Automatic Air break Star Delta up to 20 HP and Auto Transformer starter for above 20 HP starting and for continuous operation.
2000 LPM x 40 head
Labour charges for the removal of submersible pumpset in borewell/openwell including fixing and jointing submersible cable with proper clamps upto the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, Voltmeter, Ammeter, three pilot (indicating) lamps capacitor single phasing preventor, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pumpset and trail run for 10 days.
15 HP motor
Labour charges for the erection of submersible pumpset in borewell/openwell including fixing and jointing submersible cable with proper clamps upto the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, Voltmeter, Ammeter, three pilot (indicating) lamps capacitor single phasing preventor, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pumpset and trail run for 10 days.
30 HP motor
Supply and delivery of Fully Automatic Auto Transformer Starter suitable for the motor offered. Floor mounting type air/ oil cooled Auto Transformer Starter with tapings at 50%, 65%, 80%, housed in robust steel chamber with arc and main contacts confirming to IS 8544 Part IV and as amended therafter for operation in AC three Phase 50 Hz (+/- 5%), 415V (+/- 10%) with the following components, under voltage release with no volt coil, over load relay with dash pot arrangements, single phasing preventor, LED ON/ OFF switches, Mounted Ammeter, Earth leakage relay, contactor assembly suitable for next standard KW rating, in coming and out going cable entry provisions, transformer tank including first filling of oil etc.
Supply and delivery of water supply sepical as directed by the departmental officers (air valve fixing)
50 mm dia GI pipe
G.I. Flange set
Rubber sheet for Flange set
Removal 40 HP motor of the existing old motor in nerur Including connected accessories and crane hire charges, transporting charges and .etc. complete
Supply, delivery of rubber bearing size of ID30mm to 50 mm x OD 75 mm to 90 mm x 175 mm length with suitable groove for shaft cooling as per standard specification ect. Complete.
Supply, delivery of rubber insertion sheet etc. Complete.,as directed by the departmental officers ect. Complete.
Supply and delivery of 20 mm dia and 90mm to 120 mm length of MS bolt & nut with two plate washers for column pipe as directed by the departmental officers ect.Complete., at site.
Labour charges for through cleaning of the spiders, column pipes, shafts, discharge case,sole plate, motor bed including charges for consumables etc.complete .
Servicing of the bowl assembly by removing of all wornout bushes by using hydraulic press and recondition of impeller guide portion. Providing new lock set with SS bolt and impeller cotter keys . including lathe work charges, loading,unloading and transport charges etc. complete,.
Conveyance of power pumpset (centrifugal, jet and submersible) and its accessories from divisional stores to site of works. (Melmayanur to Nerur)
Charges 90 HP motor for re erection of of motor pump set. Such as Motor ,thrust bearing assembly , motor stool, discharge case ,top shaft , shaft coupling , column pipes, line shafts, Bowl assembly and spiders . including no load and load test for specified period etc.complete,.as directed by the dept. officers.
ASV CONSTRUCTION (BID ID -1447880)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .