Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.7 LAccepted-AOC | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹39.1 L+₹89,548 (2.35%)Rejected-Finance 195 MAHESH NAGAR AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹39.2 L+₹1.0 L (2.64%)Rejected-Finance 54 KANWALI ROAD DEHRADUN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹39.8 L+₹1.6 L (4.21%)Rejected-Finance 59 NEW MARKET CLOCK TOWER DEHRADUN UK PIN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹44.4 L+₹6.3 L (16.4%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
23 Sept 2022, 6:00 pmClosed
GE UTILITY AMBALA
GE UTILITY AMBALA CANTT 133001
REPAIR MAINT OF STREET LIGHT HIGH MAST LIGHT PERIMETER LIGHT INCLUDING REPLACEMENT OF CONNECTED ITEMS AT ALLENBY LINE POWER HOUSE AND ALPHA POWER HOUSE UNDER GE UTILITY AMBALA CANTT
2022_MES_547962_1
CA NO GE U AMB T 32 OF 2022-23
Open Tender
Civil Works
Item Rate
240 days
GE UTILITY AMBALA CANTT
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE UTILITY AMBALA CANTT
₹90,000
17 Oct 2022
26 Aug 2022
26 Sept 2022
26 Aug 2022
23 Sept 2022
9 Sept 2022
26 Aug 2022 - 2 Sept 2022
Amount
Excavation in trenches n.exc 1.5 Mtr wide and n,exc 1.5 Mtr in depth in loose/soft soil and getting out for underground cable/erection of poles, stays etc complete all as specified and as directted by Engeer-in-Charge.
All as per item No 1.00 here in before but exceeding 1.5 mtr deep but not exc 3.0 mtr deep.
M&L sand cushioning for cables with river washed sand and punning to provide required cover as per SSR part I complete all as specified and as directed by Engineer-in-Charge.
Supply and laying bricks common burnt clay sub classs 'B' old size bricks for cable protection.
Description all as per item Ser No 4 here in before but except bricks Note: Old bricks retrieved from item No 16 here in after shall be used.
M&L PCC 1:4:8 type D2 using 40 mm grade mechanically crushed stone aggregate for mass filling in pole pit and foundation etc including provision of necessary from work to achieve fair finished surfaces complete all as specified and directed.
M&L for PCC 1:3:6 type C2 using 40 mm graded crushed stone aggregate as in pole foundation, coping stay etc including provision of necessary form work to achieve fair finish surfaces, complete all as specified and directed.
Returning, filling in (Soil) including spreading, levelling, watering and well ramming in layers not exc 25CM thick each layers complete all as specified and as directed by Engineer-in-Charge..
Removal of excavated material n,exc 50 Mtr away and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge.
Supply and erection of PCC pole 9.0 mtr long in true vertical position 102x172 mm at top 102x279 mm at bottom class-10 incl providing black and white strips with synthetic enamel paint 30 cm each alternate upto 1.5 mtr above the coping of pole starting with black strip including dismantling and taking down old U/S PCC Poles complete all as specified and directed by Engr-in-Charge. Note:(i) Earth work and PCC shall be measured and paid seperately (ii) Description as per direction of Engineer-in-Charge will be printed on each pole without any extra cost.
Supply and erection (in true vertical position) Steel tubular swaged poles complete with cast iron base plate, finial taper plug bolts, nuts & screws all as specified of type 410 SP-31 ( 9.0 mtr length) as specified in IS 2713 (Part-II) 1980 including one coat of red oxide primer and two coats of aluminium paint to exposed surfaces incl providing of two coats of black and white strips with synthetic enamel paint 30 cm each alternate upto 1.5 mtr above the coping of pole starting with black strip and black bituminus paint for embedded portion of pole including diamantling and taking down old steel poles compete all as specified and directed by Engr-in-Charge. Note: (i) Earth work and PCC shall be measured and paid seperately (ii) Description as per direction of Engineer-in-Charge will be printed on each pole without any extra cost.
M&L for drilling hole of any size manully as per site requirement, drilling for laying pipes under the road for crossing electrical cables complete all as per direction of Engr-in-Charge. Note : Pipe will be measured and paid for seperately.
Disconnecting & taking out defective underground cable from trenches, pole, pipe, floor, wall etc and locate the fault, rectify, the defect and relaying the XLPE cable underground PVC insulated and overall sheathed aluminium conductor heavy duty 1100 volts including testing any size complete as directed by Engr-in-charge (Excavation/earth work & sand cushioning, brick and joint shall be measured & paid for seprately).
Disconnecting & taking out old defective underground cable any size and any type from trenches, pole,pipe, floor, wall etc complete all as directed.
Supply, laying, connecting and testing XLPE underground cable insulated, and overall sheathed with cluminium conductor heavy duty 1100 volts grade 16 sqmm 4.0 core laid in trenches/ on pole/road crossing or passing through existing/new pipe under road crossing clamping on wall etc. Note: (i) Earth work, sand , bricks, returning filling Aluminium thimbles/lugs will be paid seperately. (ii) Cost of laying electrical cable through new/existing pipe under road, buildings, railway tracks, highways are incl in the quoted rates. (iii) All equiments, machinery or tool if required for laying electrical cable through new/existing pipes shall be provided by the contractor without any extra cost.
All as per item Ser No 17 here in before but for 4.0 core 10 sqmm
All as per item Ser No 17 here in before but for 3.5 core 25 sqmm
All as per item ser No 17 here in before but for 3.5 core 35 Sqmm
All as per item ser No 17 here in before but for 3.5 core 50 Sqmm
All as per item ser No 17 here in before but for 3.5 core 70 Sqmm
All as per item ser No 17 here in before but for 3.5 core 95 Sqmm
All as per item ser No 17 here in before but for 3.5 core120 Sqmm
All as per item ser No 17 here in before but for 3.5 core 150 Sqmm
All as per item ser No 17 here in before but for 3.5 core 185 Sqmm
Material & Labour for replacement of old UNSV switch fuse unit/main switch of any type/capacity with new switch fuse unit HRC type, single pole & neutral/Double pole 240 VAC, 50 Hz, 32 Amps conforms to IS-13947 Part-III alongwith sheet metal enclosure complete all as directed.
Material & Labour for replacement of old UNSV switch fuse unit/main switch of any type/capacity with new switch fuse unit HRC type, single pole & neutral/Double pole 415 VAC, 50 Hz, 100 Amps conforms to IS-13947 Part-III alongwith sheet metal enclosure complete all as directed.
Material & Labour for replacement of old UNSV switch fuse unit/main switch of any type/capacity with new MCCB 4 pole 415 VAC, 50 Hz, 63 Amps conforms to IS-13947 Part-III alongwith sheet metal enclosure complete all as directed.
Taking down UNSV fabricated box, M & L for fabrication of Kiosk box made out of fibre material complete with TPN , aluminium bus bar, suitable for one number MCB (SP) including one No MCB (SP) 6 Amps 240 volts including connectors and din rail for fixing MCB inside the box , clamps of size 20x4mm on PCC/Steel tubular pole complete all as specified and as directed by Engr-in-charge.
Taking down old unsv switches, S & F Automatic street light control with infrared sensor based NATRURE SWITCH and VOLTAGE MONITORING SYSTEM (VMS) . Three phase load of 8 KW for automatic switching of street lights. Nature switch operation should be based on Natural light Lux level . Required illuminance level for switching ON is < 30 Lux and for switching OFF < 10 Lux. The sensor should also have part night operation facility of min, 4 hrs to max 12 hrs, VMS should have adjustable over & under voltage trip level and protection against phase loss, Neutral loss & phase reverse incl power contractors (63Amos) and incoming-outgoing MCB rating of 63 Amps & main load circuit wiring (Copper) of minimum 16 sqmm. The sensor, VSM power contractor, MCBs incl connected items should be enclosed in a pole/wall mountable enclosure made of rust proof, electric shock proof, termite proof and FR grade SMC junction box conforming to IP54. The circuit should also have provision for manual operation (i.e sensor & VMS by pass option) Note:- (i) S S Nut bolts, clamp for fixing on poles/wall are to be included in quoted rates. (ii) The sensor must have the warranty of min 2 years . (iii) The test certificate and warranty cirtificate must be provided by supplier. (iv) Cost of marking description on the box is incl quoted rate.
Taking down old unsv switches, S & F of Automatic street light control with infrared sensor based NATRURE SWITCH and VOLTAGE MONITORING SYSTEM (VMS). Three phase load of 5 KW for automatic switching of street lights. Nature switch operation should be based on Natural light Lux level . Required illuminance level for switching ON is < 30 Lux and for switching OFF < 10 Lux. The sensor should also have part night operation facility of min, 4 hrs to max 12 hrs, VMS should have adjustable over & under voltage trip level and protection against phase loss, Neutral loss & phase reverse incl power contractors (3 nos of capacity 16 amps per phase each) and incoming (3 nos capacity 20 amps each)-outgoing MCB (3 nos of capacity 20 amps each) & main load circuit wiring (Copper) of minimum 10 sqmm. The sensor, VSM power contractor, MCBs incl connected items should be enclosed in a pole/wall mountable enclosure made of rust proof, electric shock proof, termite proof and FR grade SMC junction box conforming to IP54. The circuit should also have provision for manual operation (i.e sensor & VMS by pass option) Note:- (i) S S Nut bolts, clamp for fixing on poles/wall are to be included in quoted rates. (ii) The sensor must have the warranty of min 2 years . (iii) The test certificate and warranty cirtificate must be provided by supplier. (iv) Cost of marking description on the box is incl quoted rate.
Supply and fixing in replacement 2 way centre off load changeover switches double pole 4 modules 63 Amps, 230 volts allows changeover from main supply to generator supply & vice versa suitable to fix in distribution box din rail complete all as per direction of Engr-in-charge.
Supply and fixinf in replacement of on load changeover switches 4 pole 100 Amps, 415 volts fixed in sheet metal enclosure allows changeover from main supply to generator supply & vice versa complete all as per direction of Engr-in-charge.
Dismantling and taking down UNSV LED street/security/flood lights upto 90 watt after disconnection electric supply and fix again after repairing of unsv AC/DC drivers incl proper connections all as directed by Engr-in-charge. Note: (i) Cost of repair and driver is incl in quoted rate. (ii) If repair is not possible then supply only street/security light will be measured and paid seperately under relevent items.
Dismantling and taking down UNSV LED street/security/flood lights upto 200 watt after disconnection electric supply and fix again after repairing of unsv AC/DC drivers incl proper connections all as directed by Engr-in-charge. Note: (i) Cost of repair and driver is incl in quoted rate. (ii) If repair is not possible then supply only street/security light will be measured and paid seperately under relevent items.
Dismantling and taking down old unsv street/security lights Material and labour for new LED street light fittings of 72 watt system wattage and high preesure die cast aluminium housing with sealed toughened glass cover, TOP opening separe driver compartment with frame, IP 66 protection suitable for pole mounting SMD led array with lense, cool white 6500 K, LED efficacy>120lm/W and system efficacy 90 lm/w 240 volts AC, 50 Hz CRI>70% operating voltage range 160 V-270 V, power factor>0.95, working temperature range-20 degree C to 60 degree C, built in surge protection of more than 5kv with facility of power supply shall be removed without removing light fitting from pole incl make proper connection, cutting, welding, drilling holes, nut bolts, washer complete all as direted by Engineer-in-Charge.
Dismantling and taking down old unsv street/security lights Material and labour for new LED street light fittings of 90 watt system wattage and high preesure die cast aluminium housing with sealed toughened glass cover, TOP opening separe driver compartment with frame, IP 66 protection suitable for pole mounting SMD led array with lense, cool white 6500 K, LED efficacy>120lm/W and system efficacy 90 lm/w 240 volts AC, 50 Hz CRI>70% operating voltage range 160 V-270 V, power factor>0.95, working temperature range-20 degree C to 60 degree C, built in surge protection of more than 5kv with facility of power supply shall be removed without removing light fitting from pole incl make proper connection, cutting, welding, drilling holes, nut bolts, washer complete all as direted by Engineer-in-Charge.
Dismantling and taking down old unsv street/security lights Material and labour for new LED street light fittings of 100 watt Flood light system wattage and high preesure die cast aluminium housing with sealed toughened glass cover, TOP opening separe driver compartment with frame, IP 66 protection suitable for pole mounting SMD led array with lense, cool white 6500 K, LED efficacy>120lm/W and system efficacy 90 lm/w 240 volts AC, 50 Hz CRI>70% operating voltage range 160 V-270 V, power factor>0.95, working temperature range -20 degree C to 60 degree C, built in surge protection of more than 5kv with facility of power supply shall be removed without removing light fitting from pole incl make proper connection, cutting, welding, drilling holes, nut bolts, washer complete all as direted by Engineer-in-Charge.
Dismantling and taking down old unsv street/security lights Material and labour for new LED street light fittings of 200 watt Flood light system wattage and high preesure die cast aluminium housing with sealed toughened glass cover, TOP opening separe driver compartment with frame, IP 66 protection suitable for pole mounting SMD led array with lense, cool white 6500 K, LED efficacy>120lm/W and system efficacy 90 lm/w 240 volts AC, 50 Hz CRI>70% operating voltage range 160 V-270 V, power factor>0.95, working temperature range -20 degree C to 60 degree C, built in surge protection of more than 5kv with facility of power supply shall be removed without removing light fitting from pole incl make proper connection, cutting, welding, drilling holes, nut bolts, washer complete all as direted by Engineer-in-Charge.
Supply and fix 1100 volt grade heavy duty cable PVC insulated aluminium stranded conductor PVC sheathed suspended by insulating hanger not more than 1 mtr apart including 4mm suspension, cable size 10 sqmm twin core stranded conductor
Supply and fix or passing through pipe, 1100 volts grade heavy duty PVC insulated flat twin core cable of size 4 sqmm nominal cross section with connection in sintex box flood light complete all as specified and directed by Engr-in-charge. Note : PVC pipe will be measured and paid seperately under relevent items.
Supply and fix rigid non-metallic PVC conduit of dia 20 mm exclusive of boxes (Junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. Note : PVC pipe will be clamped at three position on pole and cost of clamp, nut, bolts etc are incl in quoted rates.
Material & Labour for overhauling, servicing, repairing of gear box of high mast light incl replacement of unsv parts and make full functioning of gear box complete all as per direction of Engr-in-charge.
Material & Labour for overhauling, servicing, repairing of 3 phase induction motor 1.1 KW,415 volt, 920 RPM, 50 Hz single phase of high mast light incl replacement of unsv part and make full functioning of motor complete all as per direction of Engr-in-charge.
Supply and fixing stay assembly complete with all accessories, such as stay plate 230x230x6 mm, stay rod 215 cm long and 16 mm dia with nuts incl GI bow turn buckle, GI stay wire, Loop type insulator etc all as per electrical plate No 1 or SSR part 1 and as directed incl taking down old unsv. Note: Only excavation and PCC work will be measured and paid seperately.
M & L in replacement incl dismantling and taking down old cross arms,bracings, supports, clamps and back plates fabricated from structural steel section incl nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape, size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint.
M&L in replacement shackle type porcelain vitreous white or brown insulator including GI straps, washers, insulators, bolts and nuts for working pressure 1100 volts, 75 mm height, 90 mm dia, cross section of strap 30mmx3mm & dia of bolt 12 mm complete all specified and as directed by Engineer-in-charge.
M&L for aluminium conductor steel reinforced (ACSR) including fixing, stretching on poles and proper noseling with binding wire with insulator of any size as required at site including taking out old U/S ACSR conductor complete all as specified by Engr-in-charge.
Dismantling and taking down old u/s earthing and material & labour for earthing complete with galvanized steel earth electrode plate of size 60x60x6mm thick burried directly in ground/earth pit not less than 2.25 mtr deep below normal ground level and top edge of earth electrode not less than 1.5 mtr below normal ground level and connected with GI earth wire of size 4mm dia by means of nut, bolts, washers etc to eqpt/machinery all as shown in electric plate No 3 of SSR Pt I including PCC (1:3:6) pit, cover 50mm thick RCC 1:2:4 type B-1 using 8mm TMT bars @ 10 cm C/C both ways, 20 mm bore medium grade GI protection & watering pipe, funnel, wire mesh, earth work, common salt, charcol dust complete all as specified and as directed by Engr-in-charge.
Material and labour for fixing in replacement GI tubing 40 mm bore light grade on poles, on walls, under floors, road crossing, as reqd at site complete all as directed by Engr-in-charge. Note: Clamps, Nut bolts, saddle etc will be measured and paid separately.
Supply and fixing Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required 4mm dia galvanised iron steel wire complete all as direction of Engr-in-charge.
M&L for fixing of new street light bracket made out of GI pipe medium grade 25 mm bore suitable to fit with LED street light approx length not less than 120cm bent to shape including new clamps made of MS flat of size 30x4 mm thick including cutting, welding holes, nut, bolts washers etc including two coat of aluminium paint over one coat of red oxide primer on MS work complete all as specified and as directed.
Supply and installation in replacement of all in one integrated Solar street light 25 Watt compact, aesthetic eco friendly and modern integrated Solar Street in extruded aluminium housing with high efficiency mono crystaline silicon photo voltaic panel, high efficency SMD LED 6500K having secondary lens optic for street light distribution,high performance lithium battery, MPPT charge controller and intelligent control, module/sensor with higher reliability long service life including 50 mm bore GI pipe medium grade pole upto 4 mtr height for mounting of Solar Lights suitable for easy and quick instllation including PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) complete all as specified and directed.
Supply and fixing in repair/replacement contactor 18 Amp 3 Pole complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair/replacement contactor 40 Amp 2 Pole complete all as specified and directed by Engineer-in-Charge.
Note:- Amount of credit of Rs. 146375.00 for retrieved materials is mentioned in Schedule of Credit attached in tender documents in pdf form which will be deducted offline while acceptance of tender.
Raman Electric Trading Co
Saurav Enterprises
M/s badrinath Traders
R D Bansal
M/s Friends Engineering Works
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .