| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹2.3 LQualified Make: Mahindra
Model: MAHINDRA 2158 GM C-2 22 IIIRD FLOOR MAIN MARKET MOTI NAGAR DELHI DELHI 110015 | WEST DELHI | DELHI | 110015 | Make: Mahindra
Model: MAHINDRA 2158 GM C-2 | ₹2.3 L | L1 | Qualified |
| 2 | L2₹2.3 L+₹500 (0.22%)Qualified Make: MAHINDRA - GSP
Model: MM1810SIT-SD(R1)-C2 B 2 16 MOHAN COOPERATIVE INDUSTRIAL ESTATE BADARPUR BORDER NEW DELHI SOUTH DELHI DELHI 110044 | SOUTH EAST DELHI | DELHI | 110044 | Make: MAHINDRA - GSP
Model: MM1810SIT-SD(R1)-C2 | ₹2.3 L+₹500 (0.22%) | L2 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
7 Jun 2018, 7:00 pmClosed
diesel generators- DG Sets Diesel Generators- DG Sets ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values OUTPUT CAPACITY RATING/PHASE Nominal Rated Capacity (KVA) 10 3.5
5
7.5
10
15
20
25
3 0
40
62.5
82.5
100
125
160
180
200
250
320
380
400
500
600
750
5 0
140 No of Phase - Single phase
Three Phase ENGINE Make of Engine - - Model Number of Engine - - Capacity of Engine (cc) - - Engine Power (kWm) - - ISI Marking to IS :10001 for engine true - Type of Engine cooling Liquid Cooled Air Cooled
Liquid Cooled Type of governer Mechanical Mechanical
Electronic Class of governer A1 A0
A1
A2 Number of cylinders (nos) 2 - No of Strokes (nos) 4 - Rated RPM of Engine (RPM) - 1500
3000 1/4 Overload capacity for one hour for every 11 hours continuous running at full load (%) 10 - Specific Fuel Consumption (gm/kWh) - - Starting voltage (volt) 12 - ALTERNATOR AC GENERATOR(ALTER NATOR) Make - - AC GENERATOR(ALTER NATOR) model Number - - Rating of AC Generator (KVA) 10 - Power Factor of AC generator 0.8 - Efficiency at rated Power factor at 75% of full Load 84.5 - Compliance of Alternator to IS:13364(part-1) Yes - Type of alternator Brushless - Voltage Regulation Grade VG 3 - Alternator IP Rating IP 23 - Class of Insulation H - CONTROL PANEL Control Panel Manual Manual
AMF IP Rating of Control Panel IP 53 - ACOUSTIC ENCLOSURE Sheet Thickness 1.6 1.6
1.8
2
1.2 Thickness of Foam 25 - Density of Foam for sound insulation 26 - Noise level at 1 meter (dB) 75 - BATTERY Battery Type & Specification Low Maintenance free to IS: 14257 for high cranking performance - Battery capacity (Ah) - - No of batteries 1 - TEST REPORTS Availability of Type test report for Engine from Central govt/NABL/ILAC accredited laboratory Yes - Test Report number - - 2/4 and date(Engine) Name and address of laboratory(Engine) - - Availability of Type test report for Alternator from Central government/NABL/ILAC accredited laboratory Yes - Test Report number and date(Alternator) - - Name and address of laboratory(Alternator) - - DG set meet requirements of Enviro nmental(Protection) Rules 1986
in respect of noise and emission norms
as described in STC Yes - WARRANTY INSTALLATION & COMMISSIONING Warranty 2 Installation & Commissioning Without Installation With Installation
Without Installation Agreed to STC of the Product Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Philem Manglemba Singh 783360
O/O The Commandant
31st Bn Gossaigaon
1 15 EMD Required No ePBG Required No
141639
GEM/2018/B/20207
diesel generators- DG Sets
15 days
Assam; Kokrajhar
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| diesel generators- DG Sets Diesel Generators- DG Sets ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values OUTPUT CAPACITY RATING/PHASE Nominal Rated Capacity (KVA) 10 3.5 | - | - | - |
| 5 | - | - | - |
| 7.5 | - | - | - |
| 10 | - | - | - |
| 15 | - | - | - |
| 20 | - | - | - |
| 25 | - | - | - |
| 3 0 | - | - | - |
| 40 | - | - | - |
| 62.5 | - | - | - |
| 82.5 | - | - | - |
| 100 | - | - | - |
| 125 | - | - | - |
| 160 | - | - | - |
| 180 | - | - | - |
| 200 | - | - | - |
| 250 | - | - | - |
| 320 | - | - | - |
| 380 | - | - | - |
| 400 | - | - | - |
| 500 | - | - | - |
| 600 | - | - | - |
| 750 | - | - | - |
| 5 0 | - | - | - |
| 140 No of Phase - Single phase | - | - | - |
| Three Phase ENGINE Make of Engine - - Model Number of Engine - - Capacity of Engine (cc) - - Engine Power (kWm) - - ISI Marking to IS :10001 for engine true - Type of Engine cooling Liquid Cooled Air Cooled | - | - | - |
| Liquid Cooled Type of governer Mechanical Mechanical | - | - | - |
| Electronic Class of governer A1 A0 | - | - | - |
| A1 | - | - | - |
| A2 Number of cylinders (nos) 2 - No of Strokes (nos) 4 - Rated RPM of Engine (RPM) - 1500 | - | - | - |
| 3000 1/4 Overload capacity for one hour for every 11 hours continuous running at full load (%) 10 - Specific Fuel Consumption (gm/kWh) - - Starting voltage (volt) 12 - ALTERNATOR AC GENERATOR(ALTER NATOR) Make - - AC GENERATOR(ALTER NATOR) model Number - - Rating of AC Generator (KVA) 10 - Power Factor of AC generator 0.8 - Efficiency at rated Power factor at 75% of full Load 84.5 - Compliance of Alternator to IS:13364(part-1) Yes - Type of alternator Brushless - Voltage Regulation Grade VG 3 - Alternator IP Rating IP 23 - Class of Insulation H - CONTROL PANEL Control Panel Manual Manual | - | - | - |
| AMF IP Rating of Control Panel IP 53 - ACOUSTIC ENCLOSURE Sheet Thickness 1.6 1.6 | - | - | - |
| 1.8 | - | - | - |
| 2 | - | - | - |
| 1.2 Thickness of Foam 25 - Density of Foam for sound insulation 26 - Noise level at 1 meter (dB) 75 - BATTERY Battery Type & Specification Low Maintenance free to IS: 14257 for high cranking performance - Battery capacity (Ah) - - No of batteries 1 - TEST REPORTS Availability of Type test report for Engine from Central govt/NABL/ILAC accredited laboratory Yes - Test Report number - - 2/4 and date(Engine) Name and address of laboratory(Engine) - - Availability of Type test report for Alternator from Central government/NABL/ILAC accredited laboratory Yes - Test Report number and date(Alternator) - - Name and address of laboratory(Alternator) - - DG set meet requirements of Enviro nmental(Protection) Rules 1986 | - | - | - |
| in respect of noise and emission norms | - | - | - |
| as described in STC Yes - WARRANTY INSTALLATION & COMMISSIONING Warranty 2 Installation & Commissioning Without Installation With Installation | - | - | - |
| Without Installation Agreed to STC of the Product Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Philem Manglemba Singh 783360 | - | - | - |
| O/O The Commandant | - | - | - |
| 31st Bn Gossaigaon | - | - | - |
| 1 15 EMD Required No ePBG Required No | - | - | - |
Exempted
7 Jun 2018
28 May 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_141639.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .