Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.7 LAccepted-AOC CHAKKITTAPARA KOZHIKODE DISTRICT KOYILANDI TALUK KERALA | ₹13.7 L | L1 | Accepted-AOC lowest among the quoted was accepted by the review committee |
| 2 | L2₹14.4 L+₹70,005.07 (5.09%)Rejected-Finance SULTHAN BATHERY WAYANAD | SULTHAN BATHERY | WAYANAD | KERALA | ₹14.4 L+₹70,005.07 (5.09%) | L2 | Rejected-Finance Highest among the quoted |
| Sl No | Description | Qty | Unit | ASHRAF. K.K. L1 | Shaji KC L2 |
|---|---|---|---|---|---|
| 1.00APPENDIX A - MCF phase 2 | |||||
| 1.01 | INSTALLATION OF PUMP SET &ACCESSORIES a)Pump & Motor
"Supply, erection, testing and commissioning of KWA pre-qualified reputed make open
well submersible motor pump set, coforming to IS 8034/2002 and amended thereafter
and BEE 3 Star of rated discharge, and Head, with Bronze or Cast SS impeller, Brass
Screws and CI FG 200 grade Pump Bowl/ Diffuser with ISI mark. The pump shall
be directly coupled to a continious rated two pole suitable wet type vertical squirrel
cage induction motor as per IS 9283/ 1995 as amended thereafter, siutable for
operation in AC 3 phase 380 V + /- 10%, 50 Hz + / - 5%,
Duty Conditions :
Discharge -1.95lps
Total Head - 108m
Starter
Supply and delivery of Direct On Line starter confirming to IS13947, IEC60947-1 and
as amended thereafter with suitable KW rating for operation in AC/Three
Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal
Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection,
Indication lamp, starting capacitor, running capacitor and On/Off Push button
switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated
cable, powder coated vermin proof box including the capacitor
Panel board
Supply, erection, testing and commissioning of one number open board - single sheet
type control panel board, suitable for providing control system for running motor
pump set, suitable capacity Main Switch, DOL starter supplied, provided with a
common earth for the entire panel as per IE rules and code of practice. The panel shall
be fitted on the Wall or seperate MS Support to prevent any wetness, moisture,
allowing sufficient free space for wiring, air circulation in back side of board with
proper support on wall or support, including necessary plastering patch works,
concrete works
Cabling work
Supply, laying, testing and commissioning Flat submersible Copper Cable not below
4 sqmm for wiring between Main switch, Starter, Motor pump set considering energy
conservation, including additional length allowance as loop for future repaire as per
the direction of Engineer.
Earthing
Supply of all materials and providing suitable earthing by
using suitable size pipe/plate eartihing Gl/copper strip buried in ground and giving
double earthing to motor, starter, panel board etc. as per IE standards
Capacitor
Supply, erection, testing and commissioning of heavy duty
APF capacitor for the motor to get a power factor above 0.95. The capacitor shall
confirm to IS 2834
Valves
Supply of suitable size best quality heavy duty ISI marked CI
double flanged sluice valve and Non retum valve of 50 mm or dia of pumping line
1.60 PN pressure rating. Fitting of valves shall include proper RCC support for Non
return valves and Sluice Valves of reputed make. Pressure Gauge
Supply of suitable size best quality heavy duty ISI marked Pressure Gauge with
controll Valve
Suction and delivery pipe connections
Supply and fitting of dia. not below 50 mm dia. according to pump discharge, best
quality C class GI erection pipe for a total length of 10 m suitable for the above
pump set with suitable long coupling, bends, Flanges, nut and bolts IR sheet packing
etc. complete (erection pipe shuould be of 3 m each with suitable coupling / flanged
joints to withstand the heavy load and for facilitating lifting and erection of motor)
and connecting the delivery side of the pump with the valves and suitable specials,
including cutting, welding, jointing to link the line with existing pumping main near
well.
General Conditions
Warranty - 2 years (rate inclusive of 2 year warranty and maintenance during a period
of 2 years from the date of commissioning), for Motor pump set and acessories
supplied.
Supply of 4 Sq. mm additional cable beyond the initial
supply of 10 m.
50 mm GI pipe of Class C for connecting
with the existing pumping main beyond 10 m | 1 | set | 81,616.56 ₹81,616.56 Lowest | 90,675 ₹90,675 |
| 1.02 | PUMPHOUSE: Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm
or nearest available size confirming to IS 2185 part I of 1979 for super structure up to
floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc
complete. | 2.4 | cum | 6,216.54 ₹14,919.7 Lowest | 6,906.51 ₹16,575.62 |
| 1.03 | Reinforced cement concrete work in beams, suspended floors, roofs, having slope up
to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills,
staircases and spiral stair cases up to floor five level excluding the cost of centering,
shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone
III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size
derived from natural sources). | 0.79 | cum | 11,113.4 ₹8,801.81 Lowest | 12,346.86 ₹9,778.71 |
| 1.04 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing
in position and binding all complete upto plinth levelThermo - Mechanically Treated
bars of grade Fe-500D or more | 79.2 | kilogra m | 92.94 ₹7,360.85 Lowest | 103.26 ₹8,178.19 |
| 1.05 | Centering and shuttering including strutting, etc. and removal of form for:Suspended
floors, roofs, landings, balconies and access platform | 2.04 | sqm | 794.71 ₹1,621.21 Lowest | 882.92 ₹1,801.16 |
| 1.06 | Centering and shuttering including strutting, etc. and removal of form for:Lintels,
beams, plinth beams, girders bressumers and cantilevers | 0.1 | sqm | 630.71 ₹63.07 Lowest | 700.72 ₹70.07 |
| 1.07 | Centering and shuttering including strutting, etc. and removal of form for:
Edges of slabs and breaks in floors and wallsUnder 20 cm wide | 7.64 | metre | 188.6 ₹1,440.9 Lowest | 209.54 ₹1,600.89 |
| 1.08 | 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) | 27.95 | sqm | 305.7 ₹8,542.79 Lowest | 339.63 ₹9,490.96 |
| 1.09 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone
aggregate)finished with a floating coat of neat cement, including cement slurry, but
excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal
size stone aggregate | 2.04 | sqm | 565.01 ₹1,152.62 Lowest | 627.72 ₹1,280.55 |
Tender Value
₹15.3 L
EMD Value
₹38,200
Closing Date
3 Mar 2026, 3:00 pmClosed
Regional Project Director
Kerala Rural Water Supply and Sanitation Agency, Regional Project Management Unit, Malappuram, MMC.X/108-112, UMK Tower, Uphill, Jubilee Road, Near Passport Office, Malappuram P.O. - 676 505
Retender - MCF Phase - 2 Work (Pump House, Distribution Network, OHSR and Related Works) in Villiyapalli GP - Deposit Work
2026_KRWSA_839925_1
RE1/KRWSA/MPM/DPT/VLY/25-26/10
Open Tender
Civil Works - Water Works
Item Rate
180 days
Villyappalli GP in Kozhikkode District
As per tender document
7 documents required · 7 mandatory
₹2,500
₹38,200
22 Sept 2026
24 Feb 2026
4 Mar 2026
24 Feb 2026
3 Mar 2026
24 Feb 2026
24 Feb 2026 - 3 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1APPENDIX A - MCF phase 2 | |||||
| 1.01 | INSTALLATION OF PUMP SET &ACCESSORIES a)Pump & Motor
"Supply, erection, testing and commissioning of KWA pre-qualified reputed make open
well submersible motor pump set, coforming to IS 8034/2002 and amended thereafter
and BEE 3 Star of rated discharge, and Head, with Bronze or Cast SS impeller, Brass
Screws and CI FG 200 grade Pump Bowl/ Diffuser with ISI mark. The pump shall
be directly coupled to a continious rated two pole suitable wet type vertical squirrel
cage induction motor as per IS 9283/ 1995 as amended thereafter, siutable for
operation in AC 3 phase 380 V + /- 10%, 50 Hz + / - 5%,
Duty Conditions :
Discharge -1.95lps
Total Head - 108m
Starter
Supply and delivery of Direct On Line starter confirming to IS13947, IEC60947-1 and
as amended thereafter with suitable KW rating for operation in AC/Three
Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal
Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection,
Indication lamp, starting capacitor, running capacitor and On/Off Push button
switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated
cable, powder coated vermin proof box including the capacitor
Panel board
Supply, erection, testing and commissioning of one number open board - single sheet
type control panel board, suitable for providing control system for running motor
pump set, suitable capacity Main Switch, DOL starter supplied, provided with a
common earth for the entire panel as per IE rules and code of practice. The panel shall
be fitted on the Wall or seperate MS Support to prevent any wetness, moisture,
allowing sufficient free space for wiring, air circulation in back side of board with
proper support on wall or support, including necessary plastering patch works,
concrete works
Cabling work
Supply, laying, testing and commissioning Flat submersible Copper Cable not below
4 sqmm for wiring between Main switch, Starter, Motor pump set considering energy
conservation, including additional length allowance as loop for future repaire as per
the direction of Engineer.
Earthing
Supply of all materials and providing suitable earthing by
using suitable size pipe/plate eartihing Gl/copper strip buried in ground and giving
double earthing to motor, starter, panel board etc. as per IE standards
Capacitor
Supply, erection, testing and commissioning of heavy duty
APF capacitor for the motor to get a power factor above 0.95. The capacitor shall
confirm to IS 2834
Valves
Supply of suitable size best quality heavy duty ISI marked CI
double flanged sluice valve and Non retum valve of 50 mm or dia of pumping line
1.60 PN pressure rating. Fitting of valves shall include proper RCC support for Non
return valves and Sluice Valves of reputed make. Pressure Gauge
Supply of suitable size best quality heavy duty ISI marked Pressure Gauge with
controll Valve
Suction and delivery pipe connections
Supply and fitting of dia. not below 50 mm dia. according to pump discharge, best
quality C class GI erection pipe for a total length of 10 m suitable for the above
pump set with suitable long coupling, bends, Flanges, nut and bolts IR sheet packing
etc. complete (erection pipe shuould be of 3 m each with suitable coupling / flanged
joints to withstand the heavy load and for facilitating lifting and erection of motor)
and connecting the delivery side of the pump with the valves and suitable specials,
including cutting, welding, jointing to link the line with existing pumping main near
well.
General Conditions
Warranty - 2 years (rate inclusive of 2 year warranty and maintenance during a period
of 2 years from the date of commissioning), for Motor pump set and acessories
supplied.
Supply of 4 Sq. mm additional cable beyond the initial
supply of 10 m.
50 mm GI pipe of Class C for connecting
with the existing pumping main beyond 10 m | 1 | set | - | - |
| 1.02 | PUMPHOUSE: Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm
or nearest available size confirming to IS 2185 part I of 1979 for super structure up to
floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc
complete. | 2.4 | cum | - | - |
| 1.03 | Reinforced cement concrete work in beams, suspended floors, roofs, having slope up
to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills,
staircases and spiral stair cases up to floor five level excluding the cost of centering,
shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone
III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size
derived from natural sources). | 0.79 | cum | - | - |
| 1.04 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing
in position and binding all complete upto plinth levelThermo - Mechanically Treated
bars of grade Fe-500D or more | 79.2 | kilogra m | - | - |
| 1.05 | Centering and shuttering including strutting, etc. and removal of form for:Suspended
floors, roofs, landings, balconies and access platform | 2.04 | sqm | - | - |
| 1.06 | Centering and shuttering including strutting, etc. and removal of form for:Lintels,
beams, plinth beams, girders bressumers and cantilevers | 0.1 | sqm | - | - |
| 1.07 | Centering and shuttering including strutting, etc. and removal of form for:
Edges of slabs and breaks in floors and wallsUnder 20 cm wide | 7.64 | metre | - | - |
| 1.08 | 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) | 27.95 | sqm | - | - |
| 1.09 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone
aggregate)finished with a floating coat of neat cement, including cement slurry, but
excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal
size stone aggregate | 2.04 | sqm | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.04 MB
tenderdocumentvly.pdf
Tender Documents • 5.57 MB
formats.pdf
Other Document • 0.08 MB
BOQ_1415660.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .