Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.9 LAccepted-AOC | L1 | Accepted-AOC lowest tender | |
| 2 | L2₹26.2 L+₹2.3 L (9.54%)Rejected-Finance KATTUPADATH H AZHEEKAL PO VYPEEN 682508 | KOCHI | ERNAKULAM | KERALA | 682508 | L2 | Rejected-Finance Other than lowest tender | |
| 3 | L3₹29.5 L+₹5.5 L (23.2%)Rejected-Finance | L3 | Rejected-Finance Other than lowest tender | |
| 4 | L4₹33.9 L+₹10.0 L (41.8%)Rejected-Finance JOY VILA MRA 230 MOOLAVILKOM JUNCTION VANCHIYOOR TRIVANDRUM 695 035 | TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | 695035 | L4 | Rejected-Finance Other than lowest tender |
Tender Value
Refer Docs
EMD Value
₹60,600
Closing Date
10 Dec 2020, 6:00 pmClosed
GE NS KOCHI
Military Engineer Services Garrison Engineer (Naval Services) Kataribagh, Naval Base Post Kochi , 682 004
REPAIR/MAINT OF LT UG CABLES SWITCH GEAR, LT FEEDER PILLERBOXES INCLUDING INCLUDINGSTREET LIGHT SYSTEM AT HQ SNC, SANJIVANI, NSRY, ELISON AVENUE AND OTHER OTM ACCN AT NAVAL BASE KOCHI
2020_MES_395736_1
8747/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
KOCHI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE NS KOCHI
₹60,600
Yes
20 Jan 2021
17 Nov 2020
12 Dec 2020
17 Nov 2020
10 Dec 2020
25 Nov 2020
17 Nov 2020 - 24 Nov 2020
Amount
Taking down existing street light/flood light/high mast light carefully (any capacity, any type) from pole/Building carrying out repair work at site including replacement of unserviceable/ defective screw, nut and bolts, spares etc, re fixing the fittings in its original position, testing and commissioning, including removal of bushes, creepers and trimming of branches around the light fitting including taking out fixing site complete all as specified and directed. Notes: (i) If any major repair is required, attending complaints and replacement of any nature in street light network at any point of time, the items shall be replaced with respective item of schedule 'A' is deemed to be inclusive (ii) Tools, ladder, vehicle required to carry out the work shall be provided by the contractor. (iii) Contractor will ensure the safety of the workers employed at his own risk. (iv) Contractor shall provided Skilled ITI Electrician and Produce the Certificate before the commencement of work. (v) Contractor should ensure that all the street lights are functional before leaving the station and rep of contractor should take receipt after all the street lights are switch ON after rendering completion to respective JEs/Engineer-in Charge as day to day basis.
Supply and fix in repair GI brackets for street light fitting made out of 40 mm dia,1.5 m long, medium grade pipe, bend to 120 degree angle shape, drilled holes etc, & fixed with clamps, nuts, bolts etc, complete all as specified and as directed.
Supply & Fix in replacement, LED street light fitting 60 watts energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top Opening separate driver compartment with IP66 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Device Complete all as specified and as directed. Make - Havells,Crompton, philips, Bajaj, Wipro, Jaguar
Supply & Fix in replacement LED Flood light fitting Secures 1x200 Watt, pressure die cast aluminum housing, and heat resistant, toughened glass with frame with IP 66 Protection, complete all as specified and as directed. Make :- Havells, Crompton, philips, Bajaj, Wipro, Jaguar/Philips.
Ditto All as per Serial Item No 4, but for LED Flood light fitting Secures 1x70 Watt.
Ditto All as per Serial Item No 4, but for 50 Watt RGB Colour complete all as specified and as directed.
Ditto All as per Serial Item No 4, but for 50 Watt Green Colour complete all as specified and as directed.
Supply & Fix in replacement of Garden Light fitting, 25 Watt LED decorative Post top for 360° indirect light with IP 65 protection Resistant to impact and corrosion. Glare-free new generation, post-top, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaries with high power lids as light source ,including taking down the old one Complete all as specified and as directed. Make: - Havells Part No LHEVBGP7PN6K025 or in Philips, Bajaj, Wipro, Jaguar.
Supply & Fix in replacement LED post top lantern fitting 40 Watt with aluminium die cast housing cum heat sink with PMMA diffuser with IP 65 protection complete with necessary pcc foundation including taking down existing old pattern unserviceable light fitting all as specified and directed. Make:- Crompton Cat Part No.LPTO-40-CDL or equivalent Make in Havells/Bajaj.
Supply & Fix in replacement decorative Hot-dipped galvanised mild steel step pole of 3.5 metre height, Mild steel base plate of 268 mm dia, and two sections which having a dia of 110mm and a height of 970 mm for bottom section and a dia of 76mm and a height of 2530mm height for top section, and plasma cut & duly chamfered opening window of 300 x 110 mm for terminal connections & mounting accessories including necessary PCC foundation and earthwork etc, complete all as specified and directed. Make:- Havells Cat Part No. LHMP02135099 or equivalent in Crompton/ Schneider /Bajaj.
Supply & Fix in replacement LED bollard type fitting 10 Watt capacity 650 mm height, LED bollard AFlare fitted with low glare diffuser with IP 65 protection, complete with necessary PCC foundation including taking down existing old pattern unserviceable light fitting complete all as specified and directed. Make:- Crompton Cat Part No. LBSL 1-10-CDL or equivalent Make in Havells/Bajaj.
Supply & Fix in replacement Bollard light fitting new generation, energy saving, environmental friendly, long life aesthetically designed die-cast aluminium landscape luminaries for downward lighting with high power LED as light source with epoxy powder coated black after phosphor chromate treatment of 16 Watt capacity all as specified and directed. Make:- Havells Cat Part No.LHLC17145099 or equivalent Make in Crompton/Bajaj.
Material & Labour for Painting to steel tubular pole of any height , any size with two coats of aluminium paint over one coat anti corrosive paint, including preparation of surface , by removing old paint, proper cleaning , filling cavities with filler, marking pole Number as existing, size of 50 mm height in black colour with yellow back ground in round shape of dia max up to 150 mm all as directed .
Material & Labour for Cement based painting to Concrete pole of any height ,any size, including preparation of old surface, marking pole Number as existing, with synthetic enamel paint ,size of 50 mm height, in black colour with yellow back ground in round shape of dia max up to 150 mm complete all as specified and directed.
Supply and fix in repair junction box made of glass fibre reinforced and transparent poly carbonate of size 126x228x111, KV PC 8104 with IP 65 protection including MCB SP, 6 Amps 1 No and suitable size clamps fixing for pole/in PCC foundation etc, including taking down the old one complete all as specified and as directed. Make :-Hensel
Supply and fix, in repair Digital time Switches ,DIN type programmable every 1 Min, with backup of 6 years ,28 Memory locations, current Capacity 16A, weekly program, with 1 change over (1co) total 28 programs , including taking down the old one all as specified and as directed. Make:-Indoasian Cat Part No TDA43110 or in L&T / ABB
Supply and fix, in repair power contactor, three pole, 80 Amp, MNX type, all as specified and as directed. Make : L&T Cat Part No CS97077.
Supply and fix in repair power contactor, three pole, 50 Amp, MNX type, all as specified and as directed. Make: L&T Cat Part No.CS97075
Supply and fix, in repair MCB SP, 6 to 32 Amp ,"C" curve, 240/415 volt AC, as per IS/IEC 60898,all as specified and as directed . Make : Indoasian Cat part No.811122 - 811129
Supply & Fix LED Street light driver 45 Watt complete all as specified and as directed. Make:- Crompton Cat Part No S0DQL-65-700-45W or in Havells/ Wipro/Bajaj/Philips
Supply & Fix in replacement LED Street light driver 75 Watt, complete all as specified and directed. Make :- Crompton Cat Part No X075C070V107FNY1BO or in Havells/ Wipro/Bajaj/Philips.
Supply&Fix in replacement LED Street light driver 100 Watt complete all as specified and directed. Make :- Crompton Cat Part No X100C070V143FNY1BO or in Havells/ Wipro/Bajaj/Philips.
Supply&Fix in replacement LED Street light driver 150 Watt complete all as specified and directed. Make :- Crompton Cat Part No X150C070V210FNI1BO or in Havells/ Wipro/Bajaj/Philips.
Material & Labour for PVC insulated copper conductor 3 core 1.5 Sqmm cable to be drawn inside the pole including taking down of old one, complete all as specified and directed.
Supply & Fix street light TIMER control panel, 110 Amps, 3 pole/230Volt, DIGITAL time switch pole/wall mounting made out of 3.15 mm CRCA sheet duly powder coated with locking arrangement, including internal wiring complete with bypass arrangements and comprising of following (or as manufactures recommendation and design). Make : Indoasian Part No.TL110DB0 or equivalent in Legrand or L&T.
Supply & Fix 7 metre high hot dip street light pole galvanised conical PU Painted (Grey Colour) poles with 151 mm bottom A/F & 75mm top A/F made up of 3mm thick HT sheet along with base plate of size 250X250x16mm thick (without bracket) complete as specified and directed.
Material & Labour for PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) as in foundation of poles and stay etc including form work complete all as specified.
Material & Labour for PCC 1:3:6 type C-1 (using 20 mm crushed stone aggregate) as in coping of poles etc including form work complete all as specified.
Excavating over areas, n exc 1.5 m deep and getting out hard/dense soil complete all as specified and directed.
Material & Labour for shifting of Panels of any size and type from one place to another place duly removing all connection carefully without any damages and losses any parts, dismantling PCC platform and mounting on PCC at place and necessary Painting with two coats of aluminium paint over one coat anti corrosive paint, including preparation of surface , by removing old paint, proper cleaning, filling cavities with filler should applied internally and externally and reconnect the cable and all connected accessories complete all as specified and directed.
Material & Labour for dismantling of old tubular poles duly removing all connection, dismantling PCC platform and taken out from the site complete all as specified and directed.
Material & Labour for dismantling of old concrete poles duly removing all connection, dismantling PCC platform and taken out from the site complete all as specified and directed.
Attending complaints of LT electrical system and taking down existing connection from LT Panel/Bus Bar Chamber/Feeder Pillar/ Electric Poles/ Building carefully (any capacity ,any type) carrying out repair work at site including replacement of unserviceable/ defective screw/nut & bolts/ Washers/Lugs/Spreaders/Hinges of doors/Repair to Locks & handles/ Indication Lamps/meters/Cable glands/Bus Bar (Copper/Aluminium) etc, re fixing the fittings in its original position, testing and commissioning, including removal of bushes, creepers and trimming of branches around the LT Panel/Bus Bar Chamber/Feeder Pillar/ Electric Poles including taking out fixing site complete all as specified and directed . Notes: (i) If any major repair is required, attending complaints and replacement of any nature in LT Power network at any point of time, the items shall be replaced with respective item of schedule 'A'. (ii) Tools, ladder, vehicle required to carry out the work shall be provided by the contractor. (iii) Contractor will ensure the safety of the workers employed at his own risk. (iv) Contractor shall provided Skilled ITI Electrician and Produce the Certificate before the commencement of work. (v) Contractor should ensure to rendering completion of all attended complaints to respective JEs/Engineer-in Charge as day to day basis.
Supply, laying in replacement and testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric cable (heavy duty) with stranded aluminium conductors, 1100 volts grade of size 400 Sqmm 3.5 core complete all as specified and directed.
Ditto All as per Serial Item No 34 but cable of size 300 Sqmm 3.5 core
Ditto All as per Serial Item No 34 but cable of size 240 Sqmm 3.5 core
Ditto All as per Serial Item No 34 but cable of size 185 Sqmm 3.5 core
Ditto All as per Serial Item No 34 but cable of size 150 Sqmm 3.5 core
Ditto All as per Serial Item No 34 but cable of size 120 Sqmm 3.5 core
Ditto All as per Serial Item No 34 but cable of size 95 Sqmm 3.5 core
Ditto All as per Serial Item No 34 but cable of size 70 Sqmm 3.5 core
Ditto All as per Serial Item No 34 but cable of size 50 Sqmm 3.5 core
Ditto All as per Serial Item No 34 but cable of size 35 Sqmm 3.5 core
Ditto All as per Serial Item No 34 but cable of size 25 Sqmm 3.5 core
Ditto All as per Serial Item No 34 but cable of size 16 Sqmm 4 core
Ditto All as per Serial Item No 34 but cable of size 10 Sqmm 4 core
Ditto All as per Serial Item No 34 but cable of size 16 Sqmm 2 core
Ditto All as per Serial Item No 34 but cable of size 10 Sqmm 2 core
Excavation in trenches soft/loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth to find out defected armoured LT UG cable by getting out soil, cable cover, sand cushioning and repair the cable with suitable cable joints and re-lay the Cable and returning filling with retrieved cable cover over sand cushioning complete all as specified and directed. Note: Sand for cushioning, cable joint, additional cable for joining should be measured and paid separately under relevant items.
Excavation in trenches soft/loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth and getting out excavated soil/sand/unserviceable LT Cable for laying of cable and getting out complete all as specified and directed.
Material and Labour for Sand cushioning and covering of UG cable using crushed metal sand in trenches for cable protection complete all as specified and directed.
Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25 cm in hard /loose soil complete all as specified and directed by Engineer-In-Charge.
Removing excavated material not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed.
Material & Labour for brick well burnt Class ‘B’ as cover to U/G cable laid dry flat over the cable with width equal to length of the cable and abutting each other with gap between adjacent slab not exceeding 10mm over underground cable for cable protection in trenches all as specified and directed by Engineer-in-Charge.
Cutting existing road/hardstand of any type by using crow bar chisel upto a depth of 30 cm for laying GI pipe including making good the surface by returning filling watering ramming in layers 150 mm thick PCC 1:2:4 over 200 mm thick hard core of broken bricks/stones over returning filling watering ramming in layers not exceeding 25 cm thick complete all as specified and directed by Engineer-in-Charge.
Material & Labour for GI tubing of size 40mm dia medium grade (ISI marked) with all fitting/accessories for protection of cable on pole/wall and under road crossing including clamps, nut bolt etc all as specified and directed (Make: Prakash Surya/Jindal/TATA)
Ditto All as per Serial Item No 56 but GI tubing of size 50mm dia
Ditto All as per Serial Item No 56 but GI tubing of size 100mm dia
Repair to existing feeder pillar box after disconnecting all incoming and outgoing cable connections and re-thumbing of various sizes of cables ,including cable loop for required sizes connecting up and making good including repairing to doors , fixing hinges and locking arrangements and including painting after removing rusts, dusts etc, with one coat of existing paint complete all as directed.
Material & Labour Cutting and removing grass including its root / bushes vegetations at the premises of LT feeder pillar boxes by using necessary tools, removing the grass etc, complete all as directed.
Supply and fix cable jointing kit for straight through heat shrinkable type joint with jointing material and all connected accessories suitable for XLPE armoured aluminium conductor cable 1100 volts grade of size 3.5 core 240 to 300 Sqmm including taking down of old one complete all as specified and directed.
Ditto All as per Serial Item No 61 but for cable jointing kit of size 150 to 185 Sqmm.
Ditto All as per Serial Item No 61 but for cable jointing kit of size 70 to 120 Sqmm.
Ditto All as per Serial Item No 61 but for cable jointing kit of size 25 to 50 Sqmm.
Ditto All as per Serial Item No 61 but for cable jointing kit of size 6 to 16 Sqmm.
Supply & Fix in replacement of MCCB 4 Pole, 630 Amps, 36 KA, 415 V, with adjustable thermal & adjustable magnetic setting Ics=100% Icu complete all as specified and directed.
Ditto All as per Serial Item No 66 but for MCCB 4Pole, 400 Amps , 36 KA, 415 V.
Ditto All as per Serial Item No 66 but for MCCB 4Pole, 320 Amps , 36 KA, 415 V.
Ditto All as per Serial Item No 66 but for MCCB 4Pole, 250 Amps , 36 KA, 415 V.
Ditto All as per Serial Item No 66 but for MCCB 4Pole, 200 Amps , 25 KA, 415 V.
Ditto All as per Serial Item No 66 but for MCCB 4Pole, 160 Amps , 25 KA, 415 V.
Ditto All as per Serial Item No 66 but for MCCB 4Pole, 125 Amps , 25 KA, 415 V.
Ditto All as per Serial Item No 66 but for MCCB 4Pole, 100 Amps , 25 KA, 415 V.
Ditto All as per Serial Item No 66 but for MCCB 4Pole, 63 Amps , 25 KA, 415 V.
Material & Labour for earthing complete with galvanized iron or steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 Metres below ground level) with top edge of earth plate not less than 1.5 Metres below ground level connected to galvanized iron strip 32x6 mm by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge of (0.68mm) 8 mesh per liner inch, 80 mm thick RCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I and specified including provision of earth wire protected by 40mm dia medium grade GI pipe and watering pipe shall be 20mm bore medium grade GI pipe, and including all excavation and earth work & connecting the earthing to an earthing test point /transformer neutral/body/ Lt panel etc, and testing on completion complete all as specified & directed by Engineer-in-Charge.
Supply & Fix, in replacement in LED indication Lamps (RYB) complete all as directed.
Material & Labour for shifting of Panels of any size and type from one place to another place duly removing all connection carefully without any damages and losses any parts, dismantling PCC platform and mount on PCC at place and necessary Painting with two coats of aluminium paint over one coat anti corrosive paint, including preparation of surface by removing old paint, proper cleaning, filling cavities with filler should applied internally and externally and reconnect the cable and all connected accessories complete all as specified and directed.
Supply & Fix, in replacement CTs as VA 15 Line Voltage 660 complete all as directed.
Supply & Fix in replacement of Manual Change over switch with enclosure 4 Pole, 250 Amps, 36 KA, 415 V, complete all as specified and directed.
Ditto All as per Serial Item No 80 but for Manual Change over switch with enclosure 4 Pole, 400 Amps, 36 KA, 415 V
Supply & Fix in replacement of Automatic Transfer Switch 500 Amps, Four Pole, AC-31A, 50 Hz, 415V Automatic/Manual with complete protection (Conforms to IS/IEC:60947-6-1) with enclosure complete all as specified and directed.
Amount of Credit Schedule shall be deducted to arrive the Contract Sum.
MS BUILDERS
PHEJAYS AGENCIES
S L ELECTRICAL WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .