Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.9 LAccepted-AOC 103 1A RAJA DINENDRA STREET KOLKATA 700 005 | KOLKATA | KOLKATA | WEST BENGAL | 700005 | L1 | Accepted-AOC AOC | |
| 2 | L2₹40.6 L+₹3.7 L (9.97%)Rejected-Finance 86 SOMNATH LAHIRI SARANI KOLKATA 700 053 | KOLKATA | KOLKATA | WEST BENGAL | 700053 | L2 | Rejected-Finance Rejected as L2 | |
| 3 | L3₹40.7 L+₹3.7 L (10.1%)Rejected-Finance 11 CROOKED LANE KOLKATA 69 | KOLKATA | KOLKATA | WEST BENGAL | 700069 | L3 | Rejected-Finance Rejected as L3 |
Tender Value
Refer Docs
EMD Value
₹99,140
Closing Date
11 May 2022, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Dist Hospital Campus saktinagar Krishnagar Nadia
Establishment of 24 bedded CCU at Ranaghat SDH SITC of AC Machine with Negative Pressure Arrangement
2022_WBPWD_377525_1
WBPWD/EE/NED/NIT/e-T/02/ (1st Call)22-23
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
Saktinagar Krishnagar Nadia
Please refer Tender documents.
5 documents required · 5 mandatory
₹99,140
Saktinagar Krishnagar Nadia
8 Aug 2022
21 Apr 2022
13 May 2022
21 Apr 2022
11 May 2022
29 Apr 2022
26 Apr 2022
120 days
Amount
SITC of Single Skin Centrifugal Cabinet Type Fan complete with DIDW- backward curved Direct driven centrifugal blower Rotaion of fan 1280 RPM, Epoxy/ galvanized steel sheet cabinet with service access doors, Inlet & outlet drilled flanges, 1.61 KW, 2-pole, IE - 2, IP-54 Standard 1Ph/230V/50 hz Motor with Fixed base, common base frame with spring isolators, Flange at inlet and outlet are provided to facilitate duct connection necessary hanging/supporting members, waterproof VFD Panel for Fan's Speed control etc . Sound level-65 dba. Capacity 65 mmwg Static pressure 2500 CFM
SITC of 10 Micron Pre Filter with Frame, it will be fitted on Centrifugal Exhust fan & on the Fresh air Damper (Make: Spectrum/ Priyanka Engg./ AFI)
SITC of 0.3 Micron Hepa Filter,it will be fitted on Centrifugal Exhust fan.(Make: Spectrum/ Priyanka Engg. Spectrum/ AFI)
Fabrication and erection of duct fabricated out of 24 SWG GI sheet complete with necessary flange connections, FRP flexible connections, GI brackets / hanger supports, to suit site condition & design layout. Exhaust Ducting,Supply ducting,Exhaust rille, (Make: TATA,SAIL,JINDAL/Reputed Make)
Supply & Pasting Al. Foil face 9mm thick Nitrile rubber insulation on duct by adhesive gum.
SITC of Discrite Powder Coaed Al. Grill without VCD (Make:Primier/AFI/Air Primier)
Supply & Fixing of Bird Screen as per direction of E.I.C.
Supply and fixing of UVC EMIITTER for the above fan's for prevention of fungus , The minimum UV intensity in the coils shall be 700-800 UW-SEC/CM2. and it should be suitable to fix the same in Fan's Duct.
Supplying, fabrication & fixing 2 Nos. M.S u-channel of 6 mm thick of size (75 mm x 40 mm x 40 mm) for making Base Frame table type for installation of Exhuast Fan incl. drilling 2 nos holes in each channel. fabricated with 2 Nos. horizontal angle of 50 mm x 50 mm x 6 mm as per direction of E.I.C.
Supply & delivery of Split type Room Air Conditioner fitted with rotary compressor having following major specification , Refrigerent R32 / R410a, Rated cooling capacity min( Watt) 6448 , Minimum room discharge air flow 670 CFM , Rated power input maximum 1815 w,ISEER star rating 3star,Ambient temature up to 52 to 55 dig Celsius, minimum tonnage required 2.0 TR with other modern features Make: Mitshubishi Electric / Hitachi/ Ogeneral / As per choice of EIC
Supply & delivery of Split type Room Air Conditioner fitted with rotary compressor having following major specification , Refrigerent R32 / R410a, Rated cooling capacity min( Watt) 5800 , Minimum room discharge air flow 600 CFM , Rated power input maximum 1600 w,ISEER star rating 3star,Ambient temature up to 52 to 55 dig Celsius, minimum tonnage required 1.5 TR with other modern features Make: Mitshubishi Electric / Hitachi/ Ogeneral / As per choice of EIC
Supply & delivery 5.0TR capacity concealed type Split Air Conditioner of rated cooling capacity of 90000 BTU/hr. with 3 Nos. rotary compressor,R410A / 407C Refrigerant, 2 nos. IDU of rated power supply-230V-1ph-50Hz. , 1no. ODU of rated power supply-400V-3ph-50Hz. Air flow/per IDU:- 700CFM. (Make: Hitachi/Ogeneral/Daikin / As per choice of EIC)
Lifting & shifting incl. Erection & Commissioning Charges for 2.0/1.5 TR Hi Wall Split Air Conditioner as per direction of E.I.C.
Lifting & shifting incl. Erection & Commissioning Charges for 5.5 TR Hi concealedSplit Air Conditioner as per direction of E.I.C.
Copper Refrigeration pipe line for Liquid Line with insulation (1/4" OD with 0.6 mm thick) with proper supports & brackets for 2.0/1.5 Tr Hi wall Split air Conditioner(make: Ryoku/Uniflow)
Copper Refrigeration pipe line for Suction Line with insulation (5/8" OD with 0.6 mm thick) with proper supports & brackets for 2.0/1.5/1.0 Tr Hi Wall Split & Hi Wall Split air Conditioner (make: Ryoku/Uniflow)
Control Cabling from Condensing Unit to Control Panel 3 Core 2.5 sq. mm. Communication Cable 7.5/2.0/1.5 Tr Hi Wall Split Conditioner (Make : Polycab/KEI/Finolex/Gloster)
Supply & layingSoft Drawn PVC Drain Pipe 19mm dia with proper supports & brackets as per direction E.I.C.
Supply and Installation of M.S. angle Bracket for Split , making a hole incl. fixing accessories for providing condensing unit and cooling unit mending the good damages.
Supplying, fabrication & fixing 7.5 Ton M.S. Angle/M.S C chanel of size (75 mm x 75 mmx6mm) for placing the outdoor unit of ductable split AC incl. drilling 05 nos holes in each Angle including cutting holes into the wall & grouting the same (1:1 ½ :3) etc for Air Conditioning Units
SITC of heavy duty anti vibrational pad to protect the system from any kind of unwanted vibration.
Schafolding & lifting, Shifting of Ac maching IDU, ODU
Lyric International
YOUNG ENGINEERING ENTERPRISE
technical_736473.pdf
PDF • 0.02 MB
techsummary_736473.pdf
PDF • 0.03 MB
finance_736473.pdf
PDF • 0.02 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_736473.pdf
PDF • 0.12 MB
AOC.pdf
PDF • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .