Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.1 LAccepted-AOC | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹35.0 L+₹1.6 L (4.83%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹35.2 L+₹1.9 L (5.66%)Rejected-Finance 45 38 15 JAGANNADHAPURAM VISAKHAPATNAM 530 016 | VISAKHAPATANAM | ANDHRA PRADESH | 530016 | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹36.3 L+₹2.9 L (8.77%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹36.9 L+₹3.5 L (10.5%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
Tender Value
₹41.6 L
EMD Value
₹83,200
Closing Date
20 Jan 2022, 6:00 pmClosed
Garrison Engineer P Navy Kalinga Visakhapatnam
Garrison Engineer P Navy Kalinga Military Engineer Services INS Kalinga PO Visakhapatnam 531 163
SPECIAL REPAIRS TO GUARD ROOM (BLDG. NO. P-29) UNDER SPECIAL REPAIRS B/R AND PROVN OF PROTECTIVE WORKS NEAR FIRE STATION UNDER LBW AT INS KALINGA UNDER GE(P) NAVY KALINGA
2021_MES_496891_1
GE (P)/N/K/8852 OF 2021-22
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer P Navy Kalinga Visakhapatnam
Class D, Category a (i)
6 documents required · 6 mandatory
₹500
Garrison Engineer P Navy Kalinga Visakhapatnam
₹83,200
Yes
24 Mar 2022
23 Dec 2021
22 Jan 2022
23 Dec 2021
20 Jan 2022
6 Jan 2022
Amount
Taking down chowkat or frame with shutter area n. exc 1.5 Sqm each (without taking off shutters from the frame) and removing to store.
Taking down chowkats or frame with shutter, (without taking off shutter from the frame) exc 1.5 Sqm but n.exc 4sqm each and removing from site.
Demolition of cement concrete (Unreinforced) in ground floor and pavings n.exc 15cm thickness (below or above ground level) .
Demolition of unreinforced cement concrete in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work
Dismantling floors, hearth or wall tilling including cement mortar bedding (but not backing), removing rubbish off the premises complete all as directed.
Demolition of Brick work or stone boulders masonry built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles .
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for.
2nd class hard wood (well seasoned) plain, solid, straight, chowkats and frame, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints.
Brick work with fly ash bricks straight or curved on plan exc 6.0 mtr mean radius built in cement mortar (1:6) .
Flush shutters 30 mm thick, solid core construction, with block board core and ply wood face panels, commercial type on both sides.
35mm thick 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (with sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); .
Preparation of new or previously untreated wooden surfaces of any description, over 10cm in width or girth and applying two coats of synthetic enamel paint over a priming coat of pink primer.
Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of mild steel tubes for top & bottom rails, mild steel frame covered with heat moulded wood grain printed PVC sheet (used instead of Plain colour PVC sheet) with 5mm thickx15mm wide PVC sheet beading used inside stiles & rails and decorative PVC beading of 10mmx10mm (90O) used instead of exposed portion of PVC sheet beading, panelling of wood grain printed PVC sheet to fit in the mild frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing.
Solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet, reinforced with mild steel square tube in opening as per specification & drawing.
125 mm size butt hinges, medium weight, cold rolled mild steel.
100 mm size butt hinges, medium weight, cold rolled mild steel .
200mm size aluminium anodised, barrel tower bolts of extruded section .
150mm size aluminium anodised, barrel tower bolts of extruded section.
150mm long extruded aluminium alloy handles, cast type, anodised.
300mm long aluminium alloy, anodised sliding door bolt with hasp & staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed.
Anodised powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified (minimum thickness of powder coating 50 micron).
Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws all complete as per architectural drawings.
Aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples.
Powder coated anodised coloured aluminium grill/ deco grill for windows, ventilators.
4.8 mm thick sheet glass, ordinary quality and glazing with oil putty in square exc. 0.5 Sq.m. in each pane.
Providing and injecting along the external wall below concrete or masonry apron using chemical emulsion @2.25 litres per linear metre including drilling and plugging holes etc in apron.
Post construction anti termite treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia. holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors.
25mm thick PCC 1:2:4 type B0 (Using 12.5 mm graded stone aggregate) as in sub base for flooring.
Non skid/matt finish ceramic coloured tiles 7mm to 8mm thick area of each tile exc. 0.18 Sq.m. but n. exc. 0.38 Sq.m. (600 mm x 600 mm x 8 mm thick), in floors etc. set and jointed in neat slurry and pointed in white or coloured cement to match for joint free over screed bed or bedding layer 15mm thick in CM 1:4 for laying floor finishes.
Non skid/matt finish ceramic coloured tiles 7mm to 8mm thick area of each tile exc. 0.18 Sq.m. but n. exc. 0.38 Sq.m. (600 mm x 600 mm x 8 mm thick), in skirting/ vertical surfaces etc. set and jointed in neat slurry and pointed in white or coloured cement to match for joint free over backing coat of 10mm thick in CM 1:3 for laying wall finishes.
Non skid ceramic coloured tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.11 sqm but not exc 0.18 (Ist quality) as in floor set and jointed in neat cement slurry and pointed in coloured cement to match the surface over and including 15mm thick screed bed in CM 1:4 finished even and rough.
Glazed ceramic coloured tiles 300 x 450 x 6-7mm thick/ 250 mm x 450 mm x 6-7 mm thick (Ist quality) conforming to IS-13753, as in vertical surface such as skirting/dado set in neat cement slurry and pointed in coloured cement to match the surface, including 10mm thick rendering to receive tiles in CM (1:3) finished even and rough.
In repair vitreous china, water closet pedestal pattern (white) 'P' trap (including fixing bolt, low level flushing cistern of 10 ltr capacity, flush pipe and seat cover).
In repair wash hand basin vitreous China white coloured flat back of size (550x400)mm including a pair of bracket and cutting for pinning in ends of brackets but excluding taps, waste, chain and plug.
In repair PVC connection 15mm size with PTMT nuts of length 600 mm.
In repairs, tubular towel rail stainless steel, 20mm dia., 60cm long between flanges.
In repair soap dish, chromium plated brass, of approximate size 160x160x90mm, fixed to plugs with chromium plated brass screws.
40mm dia. PVC waste pipes for WHB/sink fixed to walls including fittings and connecting to multiple floor trap.
50mm dia. PVC waste pipes for WHB/sink fixed to walls including fittings and connecting to multiple floor trap.
PVC (SWR) pipes 110 mm dia single socketed in any length with rubber ring joints fixed to walls.
PVC (SWR) pipes 75 mm dia single socketed in any length with rubber ring joints fixed to walls.
110 mm bore PVC (SWR) bends any radius.
75 mm bore PVC (SWR) bends any radius.
110 mm bore PVC (SWR) bends any radius with access door.
75 mm bore PVC (SWR) bends any radius with access door.
110mm dia. PVC (SWR) junction single (Single T) equal or unequal provided with access door.
75mm dia. PVC (SWR) junction single (Single T) equal or unequal provided with access door.
PVC (SWR) vent cowls 110mm dia..
PVC (SWR) multi floor trap 75mm dia. outlet with grating including jointing with solvent cement.
In repairs, PVC (SWR) gully trap 125/110mm, setting and jointing with solvent cement.
Grating doom 125mm dia. with waste hole of PTMT (Min weight 40 gms).
100 mm cast iron nahani trap grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4).
Taking down existing water proofing treatment/ cement plaster etc on roof of any description.
Carrying out water proofing treatment over existing roof slab using the following methods :-
(i) Brushing neat cement slurry with 3.0 kg of cement per sqm over the existing roof
(ii) 40 mm average thick PCC 1:2:4 type B1 (Using 20mm graded stone aggregate) as in padding concrete.
(iii) 15mm thick screed bed on concrete surface in cement mortar 1:3 with water proofing compound before carrying out water proofing treatment over roof slab. Note: WPC will be measured and paid separately as supply only
(iv) APP based polymeric membrane minimum weighing 3 Kg/Sq.m. and minimum 3mm thick reinforced with polyester non wove fabric (weight not less than 150 gms/Sq.m.) laid on primed surface after applying a coat of blown bitumen 85/25 grade @ 1.20 Kg/Sq.m. over bitumen primer @ 0.50 Kg per Sq.m. by forced application, applying another coat of hot blown bitumen 85/25 grade @ 1.20 Kg per Sq.m. over water proofing membrane and applying a coat of solar reflective bituminous aluminium paint @ 0.10 Kg per Sq.m. all as per the manufacturers instructions.
Supply only Integral Water Proofing Compound (ISI marked) of approved make.
20mm thick granite (of any type) work (table rubbed and polished) in skirting/ dado and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over a screed bed of 20mm thick in cement mortar 1:4.
Preparation of old surfaces of ceiling and applying three coats of white wash .
Complete removal of existing treatment of walls and applying two coat of plastic emulsion over a coat of primer including 2mm thick wall care putty.
In repair concealed type 15mm dia stop valve cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and as directed
In repair Brass chromium plated shower rose 125 mm size with or without swivel joints including fixing to steel pipe or union.
In repair 15 mm dia bib tap fancy type, chromium plated, flexible 360 degree swivel kitchen sink faucet with single handle, chrome finish
In repair 15 mm dia two way bib cock chromium plated fancy type.
In repair 15mm dia pillar tap cast copper alloy with capstan heads, chromium plated, screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts screwed for iron pipe.
In repair 15mm dia stop valve cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions.
15mm bore Health faucet with 1.5m long easy flex tube in chrome finish and wall hook.
TMT bars 6 to 8mm dia cut to length, bent to shape required including cracking bending, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia.
Reinforced Cement Concrete 1:1.5:3, type A1 (using 20mm graded granite stone aggregate) in beams, cantilevers, lintels over 1.5 m span etc and the like.
Rendering in two coats with first coat of 10mm thick in CM 1:6 and second coat of 5mm thick duly mixing water proofing compound in CM 1:4 on fair faces of brick work or concrete surfaces finished fair and even without using extra cement . Note: Supply only WPC shall be measured and paid separately.
Rendering 10mm thick on internal surfaces of brick wall or concrete surface in cement mortar 1:6 finished even and fair without using extra cement.
Rendering 5mm thick in cement plaster on ceiling in cement mortar (1:3) finished even and fair.
Applying two coats of weather shield exterior emulsion paints over a coat of primer including preparation of new external wall surfaces.
Taking up or down 15mm dia. steel tubing and connections including cleaning for refixing or removal from site.
Taking up or down 20mm dia. steel tubing and connections including cleaning for refixing or removal from site.
Taking up or down 25mm dia. steel tubing and connections including cleaning for refixing or removal from site.
In repair PP-R gate valves (brass insert) suitable for 32 mm bore PP-R pipe including connection & testing.
75mm thick PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in plinth protection/ sub base and paving finished cement concrete surfaces even and smooth without using extra cement.
Three layer PP-R (Polypropylene random copolymer) pipes of outer dia 20 mm bore pipes SDR 7.4 & SDR 11 UV stabilized and antimicrobial fusion welded having thermal stability for hot and cold water supply complete to walls, ceilings or in floors etc.
Three layer PP-R (Polypropylene random copolymer) pipes of outer dia 25 mm bore pipes SDR 7.4 & SDR 11 UV stabilized and antimicrobial fusion welded having thermal stability for hot and cold water supply complete to walls, ceilings or in floors etc.
Three layer PP-R (Polypropylene random copolymer) pipes of outer dia 32 mm bore pipes SDR 7.4 & SDR 11 UV stabilized and antimicrobial fusion welded having thermal stability for hot and cold water supply complete to walls, ceilings or in floors etc.
Dismantling water tanks of capacity exc 250 ltrs but not exc 500 ltrs and removing to store.
Rotational moulded polyethylene water storage tank (Cylindrical vertical with closed top) Conforming to IS 12701-1996 three layered hoisted and fixed in position 500 ltrs capacity complete all as specified in SSR Part I .
In repair veneered decorative 18 mm thick plywood, grade 1 (with BWR resin) with one face has decorative veneer, fixed with screws to timber frame work
Preparation of newly plastered surfaces of walls and applying two coat of plastic emulsion over a coat of primer including 2mm thick wall care putty.
Preparation of new plastered surfaces of ceiling and applying three coats of white wash.
Applying two coats of weather shield exterior emulsion paints including complete removal of existing treatment of old external wall surfaces.
Excavation in trenches n. exc 1.5 mtr wide and n. exc 1.5 mtr in depth for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, FRLS cable etc. n.exc 10 Sqm on plan and n.exc 1.5m in depth and getting out in soft /loose soil.
Plain cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation filling and mass concrete, bed etc.
Reinforced Cement Concrete,1:1.5:3, type A1 (using 20mm graded granite stone aggregate) in foundations, including rafts, footings, plinth beams etc and the like.
Reinforced Cement Concrete, 1:1.5:3, type A1 (Using 20mm graded granite stone aggregate) in columns, pillars, piers, posts and struts etc and the like.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n. exc 25 cm thick in soft /loose soil.
Removing excavated material from site to a distance n.exc 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point.
Use and waste of form work to sides of foundation/ footings, plinth beams and similar work for rough finished surfaces.
Use and waste of form work to sides of columns, pillars, posts, struts, piers and stanchions etc for fair finished surfaces.
Use and waste of form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressumers, lintels, cantilevers, shelves including supports, overhangs, etc also splays between floors and beams finished rough surfaces of concrete.
TMT bars 10mm dia and over, as reinforcement. cut to length, bent to shape required including cranking bending, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia.
TMT bars 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders, cut to length , bent to shape required including cranking bending hooking ends and binding with and including mild steel wire (annealed ) not less than 0.9mm dia or securing with clips.
Providing cement concrete type B-1,1:2:4 (using 20mm graded stone aggregate) as cast in situ in lintels upto 1.5m span, cills and other similar bands, plinth courses, string courses, lacing courses, parapets, railings upto 60 cm height, copings, coping, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating .
Rendering 10mm thick on fair surfaces of brick wall or concrete surface in cement mortar 1:4 finished even and smooth without using extra cement.
Taking down cement plaster of any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc built in cement mortar.
Taking down carefully existing aluminium /copper conductor point wiring (light / fan / socket or power point) complete, with all fittings such as switches, socket, regulator, ceiling rose, utility light fittings and lamp holders etc and removing materials from site and making good the disturbed surfaces of walls roof and floor etc as per existing specification.
Taking down carefully ceiling fan/ exhaust fan any sweep and any make after disconnecting the electrical connections, dismantling the blades and removing fan including blades for safe custody for reuse and re-assembling the fan complete and refixing the fan in same position including all electrical connection.
Concealed point wiring for One light point controlled by one, one way switch with 1.5 Sqmm (nominal cross-sectional area) FRLS PVC insulated and unsheathed 1100 V grade multi stranded copper conductor single core cable drawn through and including 20 mm PVC conduit with all fittings and accessories including one run of FRLS PVC insulated and unsheathed single core multi stranded copper conductor cable of size 1.5 Sqmm as earth continuity conductor to common earth and earth dolly including new pressed steel sunken boxes readily available (having thickness not less than 1.22 mm for boxes upto a size of 200 mm x 300 mm and beyond that the wall thickness shall not be less than 1.63 mm) concealed type with 3 mm thick bakelite sheet cover for mounting switches, sockets, fan regulator etc including testing.
All as per Srl Item No. 103 here-in-above but for One Exhaust/ fan point controlled by one, one way switch 5 Amp and regulator
All as per Srl Item No. 103 here-in-above but for One switch socket outlet point 3 pin 5 A on independent board.
All as per Srl Item No. 103 here-in-above but for One switch socket outlet point 3 pin 5 A on same board.
All as per Srl Item No. 103 here-in-above but for one light point controlled by two 2 way switch.
All as per Srl Item No. 103 here-in-above but for one switch socket out let for 5/ 15 Amps 3 & 5 pin on independent board with 4.0 Sqmm cable and 4.0 Sqmm earth wire.
Sub main wiring with two single core PVC insulated un-sheathed cable with multi-stranded copper conductor of 1.5 sq mm size and drawing into and including concealed PVC conduit of 25 mm dia with earthing cable of PVC insulated un-sheathed stranded copper conductor of size 1.5 sqmm, single core, as earth continuity wire. (NOTE: 3 runs of 1.5 Sqmm cable and one run of PVC concealed conduit 25mm dia will be measured as one unit i.e. RM)
Sub main wiring with two single core PVC insulated un-sheathed cable with multi-stranded copper conductor of 4.0 sq mm size and drawing into and including concealed PVC conduit of 25 mm dia with earthing cable of PVC insulated un-sheathed stranded copper conductor of size 4.0 sqmm, single core, as earth continuity wire. (NOTE: 3 runs of 4.0 Sqmm cable and one run of PVC concealed conduit 25mm dia will be measured as one unit i.e. RM)
Sub main wiring with two single core PVC insulated un-sheathed cable with multi-stranded copper conductor of 6.0 sq mm size and drawing into and including concealed PVC conduit of 25 mm dia with earthing cable of PVC insulated un-sheathed stranded copper conductor of size 6.0 sqmm, single core, as earth continuity wire. (NOTE: 3 runs of 6.0 Sqmm cable and one run of PVC concealed conduit 25mm dia will be measured as one unit i.e. RM)
Sub main wiring with two single core PVC insulated un-sheathed cable with multi-stranded copper conductor of 10.0 sq mm size and drawing into and including concealed PVC conduit of 25 mm dia with earthing cable of PVC insulated un-sheathed stranded copper conductor of size 10.0 sqmm, single core, as earth continuity wire. (NOTE: 3 runs of 10.0 Sqmm cable and one run of PVC concealed conduit 25mm dia will be measured as one unit i.e. RM)
XLPE insulated GI wire/strip armoured electric power cable (Heavy duty) ISI marked with stranded aluminium conductor 1100 volts grade, cross sectional area 35 Sqmm 3 core laid in trench /poles/on wall.
Switch piano flush button single pole one way 5 amps.
Switch flush type, single pole Two way 5 Amps 230 volts.
Switch socket combination with indication lamp 2 in 1, 3 pin, 5/15 amp flush type multi purpose.
Switch socket combination 2 in 1, 3 pin, 5 amp flush type multi purpose.
Ceiling rose surface bakelite three terminals.
Lamp holder insulated body suitable for Retrofit lamp.
LED tube light 20 W, 230 V, 50 HZ including LED light driver and LED batten connecting up with three core flexible copper conductor of suitable size upto ceiling rose .
LED mirror light fittings with high output diffuser 2 feet, 10 W, 230 V, 50 HZ suitable for indoor and outdoor applications.
LED bulk head fittings 10 W, 230 V, 50 HZ suitable for indoor and outdoor applications complete. Make : Surya Cat Part No. SLE BH 10W or equivalent as approved by GE
Bell ding dong 5 Amps, flush type, 230 Volts, 50 Hz.
Sheet metal enclosure for MCCB, DBs, phosphatised, Powder coated , Triple Pole and Neutral (TPN), suitable for 4 way, Double door 415 Volts all as specified and as directed.
Sheet metal enclosure for MCB, DBs, phosphatised, Powder coated , single pole and neutral (SPN) 240 Volt , double door, suitable for 8 way with din rail earth and neutral bar all as specified and as directed.
MCCB four pole of capacity 63 amps, 415 Volts, 16 KA breaking capacity.
MCB Four Pole (FP) C curve 10kA breaking capacity of 63 amps, 415 Volts in proper position.
MCB Double Pole of capacity 40 amps, 240 Volts c-series with 10kA breaking capacity.
MCB Single Pole (SP) C curve 10kA breaking capacity of 6 to 32 amps, 240 Volts in proper position.
XLPE insulated GI wire/strip armoured electric power cable (Heavy duty) ISI marked with stranded aluminium conductor 1100 volts grade, cross sectional area 25 Sqmm 4 core laid in trench /poles/on wall.
Fan regulator electronic deluxe rotary step type all as specified and as directed.
Repairing of ceiling fan of any sweep and any make including rewinding, replacement of bearings, shaft, rubber bush, down rod and complete painting of body & blades with writing MES No. on the body.
Repairing of exhaust fan of any sweep and any make including rewinding, replacement of bearings, shaft, rubber bush, down rod and complete painting of body & blades with writing MES No. on the body.
Air termination vertical type single pointing aluminium rod 12mm dia. and 300mm long.
Aluminium strip 25x3.15mm including insulating blocks, saddle and fixing screws etc fixing arrangement for roof conductor and down conductor.
Earthing complete with 7.5m CI pipe 80 mm dia with flanged ends, centrifugally cast, class A, in any length, joints with stainless steel nuts and bolts and sufficient slot upto 2.5 mtr length buried directly and preferably vertically in ground with top flanged ended 2.5 mtr below ground level welded/ connected with GI strip 32 x 6 mm size on the top edge of the flange to bottom edge of the flanged for earthing including filling the pit with charcoal common salt surrounding the earth pipe including drilling 400 mm dia bore any strata of soil to lower the CI pipe.
Note: 1. All items in the schedule shall be read in conjunction with S&F or M&L as applicable. 2. All items in the schedule shall be completed in all respect as directed by the Engr-in-Charge.
SSV CONSTRUCTIONS
SAI SAMPATH ELECTRICAL AND ENGINEERING
ARKA CONSTRUCTIONS
N V S S K N SIVA PRASAD
VASANTHA NAIDU ASSOCIATES
SRI VENKATA SAI MANIKANTA CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .