Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.8 CrAccepted-AOC 66 102 ARUN JYOTHI MULLASSERY CANAL ROAD ERNAKULAM KOCHI 682 011 | KOCHI | ERNAKULAM | KERALA | 682011 | ₹2.8 Cr | L1 | Accepted-AOC Technically Qualified and Financially accepted |
| 2 | L2₹2.8 Cr+₹4.4 L (1.56%)Rejected-Finance | ₹2.8 Cr+₹4.4 L (1.56%) | L2 | Rejected-Finance Financially Disqualified |
| 3 | L3₹2.9 Cr+₹9.0 L (3.24%)Rejected-Finance 8 34A FATHIMAPURAM TAMILNADU | TAMILNADU | ₹2.9 Cr+₹9.0 L (3.24%) | L3 | Rejected-Finance Financially Disqualified |
| 4 | L4₹3.0 Cr+₹22.1 L (7.92%)Rejected-Finance | ₹3.0 Cr+₹22.1 L (7.92%) | L4 | Rejected-Finance Financially Disqualified |
Tender Value
Refer Docs
EMD Value
₹2.7 L
Closing Date
3 Dec 2024, 5:00 pmClosed
Chief Engineer (Electrical)
Kochi Metro Rail Limited 4th Floor, JLN Stadium Metro Station, Kaloor, Kochi, Kerala-682017
ELECTRICAL UTILITY SHIFTING AND UG CABLE CONVERSION AS PART OF THE CONSTRUCTION OF ROAD WIDENING OF PREPARATORY WORKS OF PHASE-II FROM JLN METRO STATION TO PALARIVATTOM JUNCTION METRO STATION-PACKAGE IB
2024_KMRL_703045_1
KMRL/PROC/TENDER/2024-25/064
Open Tender
Miscellaneous Works
Item Rate
240 days
Kochi
Please refer Tender documents.
20 documents required · 20 mandatory
₹23,600
₹2.7 L
Yes
KMRL Corporate Office
10 Feb 2025
5 Nov 2024
5 Dec 2024
5 Nov 2024
3 Dec 2024
19 Nov 2024
5 Nov 2024 - 13 Nov 2024
12 Nov 2024
Supply of HDPE pipe conforming to PN4 as specified the size given below, laying of HDPE pipe properly and continuously joined with suitable accessories as per standard and specification.
Supply at the site of work of 11kv HT Dry Cured XLPE insulated, armoured, Aluminium conductor C-1 category FR cable as per IS 7098/part-ll /1985 with up to date amendment & specified in the specification of the sizes given below, laying of HDPE and laying of cables through HDPE pipes in all areas, all type of soil ,footpath,road ,etc by (open trench) excavation with laying arrangement in sand cushionn and brick/Tile protection at required depth ,refilling and restoration after laying of cables through pipe as required/approved by utility owning agency , Testing and commissioning of cable as required as per standards and directions of officer
11Kv XLPE 3x300sqmm
Supply at the site of work of 11kv HT Dry Cured XLPE insulated, armoured, Aluminium conductor C-1 category FR cable as per IS 7098/part-ll /1985 with up to date amendment & specified in the specification of the sizes given below, laying of cables in cable duct including cost of cable duct slab opening and closing laying it carefully using cable rollers and core cutting of cable duct for cable entry/exit ,after laying of cables through cable duct as required/approved by utility owning agency, restoration of core cutting with proper finishing,testing & comissioning of cable et complete as required as per standards and directions of officers.
11Kv XLPE 3x300sqmm
Supply at the site of work of 11kv HT Dry Cured XLPE insulated, armoured, Aluminium conductor C-1 category FR cable as per IS 7098/part-ll /1985 with up to date amendment & specified in the specification of the sizes given below, laying of cables in all type of soil ,footpath,road ,etc(open trench) by excavation with laying arrangement in sand cushionn and brick/Tile protection at required depth , refilling and restoration after laying of cables and testing & commissioning of cable et complete as required as per standards and directions of officers.
11Kv XLPE 3x300sqmm
Supply at the site of work of 1.1kv HT Dry Cured XLPE insulated, armoured, Aluminium conductor C-1 category FR cable as per IS 7098/part-l /1988 with up to date amendment & specified in the specification of the sizes given below, laying of HDPE pipe and cable laying through in HDPE pipe in all areas, all types of soil, footpath,road etc by open cable trench excavation with laying arrangement in sand cushion and brick/tile protection at the required depth and refilling after laying of cables through pipes as required/ approved by utility, including supply & doing HS type end termination, testing & commissioning of cable etc complete as required as per standards and directions of officers.
1.1Kv 3.5x185sqmm
Supply at the site of work of 11kv HT Dry Cured XLPE insulated, armoured, Aluminium conductor C-1 category FR cable as per IS 7098/part-ll /1985 with up to date amendment & specified in the specification of the sizes given below, laying of cables in cable duct including cost of cable duct slab opening and closing ,laying it carefully using cable rollers and core cutting of cable duct for cable entry/exit ,after laying of cables through cable duct as required/approved by utility owning aegncy, restoration of core cutting with proper finishing,testing & comissioning of cable et complete as required as per standards and directions of officers.
1.1Kv 3.5x185sqmm
Supply at the site of work of 1.1kv HT Dry Cured XLPE insulated, armoured, Aluminium conductor C-1 category FR cable as per IS 7098/part-I/1988 with up to date amendment & specified in the specification of the sizes given below, laying of cables in open cable trench in all types of soil, footpath, road etc., by excavation with laying arrangement in sand cushion and brick/Tile protection at required depth , refilling and restoration after laying of cables as required/approved by utility, including supply & doing HS type end termination, and testing & commissioning of cable et complete as per standards and directions of officers.
1.1Kv XLPE 3.5x185sqmm
Supply ,Drawing of 11kv Aerial bunch cable of size 3x150 + 1x120(Insulated messenger) with suitable Anchor clamp/dead clamp,suspension clamp,surge arrestor,TEE/straight through joint,termination joint,cable ties,spiral earthing set,earth connector,fitting cross arms,stainless steel strap and buckle etc using 11kv Aerial bunch cable of size 3x150 + 1x120(Insulated messenger) including cutting and removing tree branches wherever necessary and conveyance of all materials from stacking place.at the site of work and testing & commissioning of Aerial bunch cable etc complete as required as per standards & specified in the specification of the below size
11 kV Ariel bunched cable XLPE insulated of size 3 x 150+ 1 x 120 sqmm with bare/insulated Messenger
Supply ,laying of 1.1kv Aerial bunch cable of size 3x95 + 1x70(Insulated messenger) with suitable Anchor clamp/dead clamp,suspension clamp,surge arrestor,TEE/straight through joint,termination joint,cable ties,spiral earthing set,earth connector,fitting cross arms,stainless steel strap and buckle etc using 1.1kv Aerial bunch cable of size 3x95 + 1x70(Insulated messenger) including cutting and removing tree branches wherever necessary and conveyance of all materials from stacking place.at the site of work of 1.1Kv Aeriel Bunched cable as per IS & specified in the specification of the below size.
1.1Kv Aeriel bunched cable XLPE insulated of size 3x95(For phase) + 1x70(insulated messenger nuetral) + 1x16(street light) sqmm.
Supply, Making testing & commissioning of complete Heat shrinkable type indoor/ outdoor type and end termination as specified in the specification including provision of laying,dressing, Tagging,Glanding with Lugs/ferrules for termination of 11kv HT XLPE insulated cable including making holes in the switch board, clamping supporting complete as required by utility owning agency following sizes and as per standards and directions of officers. Additional loop of cable should be made before end termination on the structure/Ground 11kv H S type 3x300 sqmm
Supply making testing & commissioning of 11kv HT XLPE cable complete Heat shrinkable type straight through joint including digging and excavation of all types of soil, footpath,road etc by open cable trench excavation at required depth, identify the existing cables and refilling after completion of straight joint as required/ approved by utility, as per direction of officer 11kv H S type 3x300 sqmm
Supply ,Erection ,Testing and Commissioning of SCADA compatible outdoor extensible type ring main unit with CCT type for replacing tapping DP structure of HT circuits, and on RCC 1:2:4 foundations using foundation bolts and including cost of in-built-metering panel with battery charger ,provision of L/R switch,remote gas pressure monitoring ,fault passage indicator and 11kv HS type end termination ,standard earthing for RMU etc complete including cost of all materials and labor, as per standards and directions of officers.
Supply ,Erection ,Testing and Commissioning of SCADA compatible outdoor extensible type ring main unit with CCC type for replacing tapping DP structure of HT circuits, and on RCC 1:2:4 foundations using foundation bolts and including cost of in-built-metering panel with battery charger ,provision of L/R switch,remote gas pressure monitoring ,fault passage indicator and 11kv HS type end termination ,standard earthing for RMUetc complete including cost of all materials and labor, as per standards and directions of officers.
Supply ,Erection ,Testing and Commissioning of SCADA compatible outdoor extensible type ring main unit with CCCC type for replacing tapping DP structure of HT circuits, and on RCC 1:2:4 foundations using foundation bolts and including cost of in-built-metering panel with battery charger ,provision of L/R switch,remote gas pressure monitoring ,fault passage indicator and 11kv HS type end termination,standard earthing for RMU etc complete including cost of all materials and labor, as per standards and directions of officers.
Supply ,Erection ,Testing and Commissioning of SCADA compatible outdoor extensible type ring main unit with CCCCT type for replacing tapping DP structure of HT circuits, and on RCC 1:2:4 foundations using foundation bolts and including cost of in-built-metering panel with battery charger ,provision of L/R switch,remote gas pressure monitoring ,fault passage indicator and 11kv HS type end termination, standard earthing for RMUetc complete including cost of all materials and labor, as per standards and directions of officers.
Supply ,Erection ,Testing and Commissioning of SCADA compatible outdoor extensible type ring main unit with CCCTT type for replacing tapping DP structure of HT circuits, and on RCC 1:2:4 foundations using foundation bolts and including cost of in-built-metering panel with battery charger ,provision of L/R switch,remote gas pressure monitoring ,fault passage indicator and 11kv HS type end termination ,standard earthing for RMU etc complete including cost of all materials and labor, as per standards and directions of officers.
Supply and erection testing and commissioning of DA compactible outdoor Extensible type ring main unit, ADD ON Module RMU - Type - +C+ consists of 1nos Load Break switches with complete coupling accessories for replacing tapping DP structure of 11kv HT circuits and on RCC 1:2:4 foundations using foundation bolts and including cost of 11KV HS type end termination, Earthing, coupling with existing RMU etc complete including cost of all materials and labor, as per standards and directions of officers.
Supply and erection testing and commissioning of DA compactible outdoor Extensible type ring main unit, ADD ON Module RMU - Type - +V+ consists of 1nos Vaccum circuit breaker with complete coupling accessories for replacing tapping DP structure of 11kv HT circuits and on RCC 1:2:4 foundations using foundation bolts and including cost of 11KV HS type end termination, Earthing, coupling with existing RMU etc complete including cost of all materials and labor, as per standards and directions of officers.
Fitting including supply of material one Fuse unit (one no.), giving connection from Transformer to fuse units, fuse units to LT OH line and provision of protection cover as per standards and directions of officers
Dismantling ( Taking out from ground) of cables
Dismantling (taking out from ground) if necessary all sizes of XLPE cable/Pilca/ Pvc cables, without damaging the cable. By excavation in all types of area (all type of soil) with refilling excavated Trenches as per standards and directions of officers. This also includes handling over of dismantled cable (if not relayed) to concerned utility agency.(including Transportation)
Dismantling (taking out from tarred road and concrete surface) if necessary all sizes of XLPE cable/Pilca/ Pvc cables, without damaging the cable. By excavation in all types of area with refilling excavated Trenches as per standards and directions of officers. This also includes handling over of dismantled cable (if not relayed) to concerned utility agency.(including Transportation)
Dismantling (without damage) LT3 phase 4/5 wire OH line including existing stucture ,stay,strut,cross arms,insulators, etc...and transportation and stacking of all materials at suitable locations as per instructions including digging out loading and unloading on to lorries without damaging the materials.This also includes handling over of materials to concerned utility agency.(including Transportation)
Dismantling (without damage) HT lines(3 conductor) including existing stucture ,stay,strut,cross arms,insulators, etc...and transportation and stacking of all materials at suitable locations as per instructions including digging out loading and unloading on to lorries without damaging the materials.This also includes handling over of materials to concerned utility agency.(including Transportation).
Dismantling 11kv ABC conductor of size 3*150(for phase)+1*120(Insulated messenger) from existing HT PSC/A pole without damage , stacking of all materials at suitable locations as per instructions including loading and unloading onto lorries without damaging the materials. This also includes handling over of materials to the concerned utility agency.(including Transportation).
Dismantling 1.1Kv Aeriel bunched cable XLPE insulated of size 3x95(For phase) + 1x70(insulated messenger nuetral) + 1x16(street light) sqmm from existing HT PSC/A pole without damage stacking of all materials at suitable locations as per instructions including loading and unloading onto lorries without damaging the materials. This also includes handling over of materials to the concerned utility agency.(including Transportation).
Dismantling and shifting of existing RMU including Add on at nearest locations and re- erecting the same, including excavation,RCC 1:2:4 foundation works ,Providing 11kv HS type end termination ,looping of cable etc and standard earthing complete as required as per standards and directions of officers.
Dismantling existing Transformer and dismantling of DP/transformer Structure posts including all accessories etc and transportation, stacking of all materials at suitable location as per instruction of officer including digging out loading and unloading onto lorries, etc of poles Transformers, and materials without damaging the same.Erecting the transformer on the new constructed plinth/DP structure and giving connections,fittings including cost of standard fencing of DP/Transformer structure etc complete as per standards and directions of officers excluding cost of transformer plinth.
Dismantling existing 4 pole DP Structuress using A-pole /PSC pole as per instruction including digging out of poles , and materials without damaging the same including digging out,loading and unloadind and staking in suitable location.This also includes handling over of materials to concerned utility agency.(including Transportation).
Dismantling existing DP Structuress using A-pole /PSC pole as per instruction including digging out of poles , and materials without damage and reerecting the DP structure with the same materials at near by location as instructedby the officer.
Dismantling ,shifing and reerecting of CSS at nearest location , including excavation,RCC foundation 1:2:4 ,Providing 11KV HS end termination ,looping of cable etc and earthing complete as required including all accessories as per standards and directions of officers. Foundation: adequate size M20 grade RCC foundation with Raft including excavation , backfilling and restoration of the same shall be done by the contractor. The contractor shall submit design calculations in support of size of RCC foundation for approval.
Dismantling one LT PSC/RCC/rail pole/Tubelar/wooden pole, fittings including accessories etc including digging out and back filling pit .This also includes handling over the materials (if not relayed) to concerned utility agency.(including Transportation).Dismantling the existing street light fixtures with all accessories and erecting in nearest poles as per standard and directions of the officer
Dismantling one 11 kv A- pole/HT PSC/RCC/TW including accessories,fittings etc and This also includes handling over of dismantled cable (if not relayed) to concerned utility agency.(including Transportation)
Supply and erection at site LT PSC poles at the site of standard height including cable duct chipping/core cutting and excavation for pole erection and restoration of the same, digging and backfilling, fittings including standard cross arms and clamps, insulator, suitable stay , concrete muffing, cable mounting with suitable clamp, loop In-loop-out of cables and including all materials as per standard and directions of officer
Supply and erection at site HT PSC poles at site of standard height including cable duct chipping/core cutting and excavation for pole erection and restoration of the same,digging and back filling including standard cross Arms and clamps / insulator,stay ,concrete muffing , cable mounting with suitable clamp , loop In-loop-out of cables including all materials as per standard and directions of officer
Supply and erection one A-pole (painted MS) at site of standard height including cable duct chipping/core cutting and excavation for pole erection and restoration,digging and back filling including standard crossarms ,insulator,stay,earth leads,concrete muffing ,cable mounting with suitable clamp ,loop in loop out of cables including all materials as per standards and direction of officers.
Supply and erection one DP/Transformer structure using A-pole(painted MS) at site of required Height including foundation and AB switch, lightning arrestor, fittings, crossarms, insulator, fuse units ,cable mounting with suitable clamps and looping of cables , digging and back filling pit, earth leads including cost of standrad fencing of DP/transformer structure and standard earthing including all materials complete as per standards and direction of officers.
Providing Strut using LT pole including digging and back filling pit( taken from the dismantled items).
Providing standard earthing for poles and support, pillar boxes panels, DP structures, Transformers etc including supply of materials, Excavation, giving connection, laying lead wire, etc complete using 40mm GI pipes 3mt long and standard GI strip including all materials as per standards and direction of officers.
Constructing Transformer plinth RCC foundation(Cement concrete column) including excavation in all type of soil,shuttering works , reinforcement , backfilling and restoation of the same . Foundation: adequate size M20 grade RCC foundation with Raft including excavation , backfilling and restoration of the same shall be done by the contractor. The item includes the excavation by mechanical means (hydraulic excavator)/manual means including disposal of excavated earth, disposed earth to be levelled and neatly dressed, in all kinds of soil inclusive of cost of all materials (as per specification) including suitable colour painting for the complete structure as per standards and direction of officers.Contractor shall submit design calculation in support of size of RCC foundation for approval.
Dismantling and reconnecting S ph service connection required from the OH line incl..lower down the WP portion
Dismantling and reconnecting 3 ph service connection required from the OH line incl..lower down the WP portion
Supply, installation, testing and commissioning of 80Watt LED street light fixture without pole including accessories like brackets of 45cm length 3mm thick GI pipe ,fastners, etc. Complete installation in existing PSC pole with suitable supports. Lights fixture satisfies the followings parameters; Safety class i - The LED luminaire of minimum IP66 rating , Luminiare efficacy should be minimum 100 or above Im/W . Colour rendering index is 70 end colour temperature is 5700K - The LED luminaire optics of Type II for street light LED driver with a power factor of 0.95 and RoHS compliant . A driver with surge protection of 10kV,Life span;50000 hours
Supply,laying of XLPE insulated armoured cable with aluminium conductor size 4C 16 sq.mm for working voltage up to 1100V confirming to IS specification in the cable through supply,laying of cable duct/Trench including cost of loop in loop out termination as per standard along with all accessories like etc, conforming to IS 14930,Part ii complete with clamping,filing,cutting&jointing including cost of materials and labour for open trench excavation, concrete chiping,laying clamping,back fitting and restoration of concrete chiping etc. Complete as required.
VIJAYA ELE TECHS PRIVATE LTD. (BID ID -1987637)
Fathima Engineering Co. Pvt. Ltd. (BID ID -1985651)
Dinu Electricals (BID ID -1989015)
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .