Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.3 LAccepted-AOC 00 INFRONT OF S R K PG COLLEGE KOTLA ROAD OM MARKET FIROZABAD UTTAR PRADESH 283203 | FIROZABAD | UTTAR PRADESH | 283203 | L1 | Accepted-AOC accept | |
| 2 | L2₹19.7 L+₹7.3 L (58.8%)Rejected-AOC 1ST FLOOR SIDHARTH TOWER BALTI KHARKHANA BYELNE S J ROAD ATHGAON GUWAHATI KAMRUP ASSAM 781001 | KAMRUP METRO | ASSAM | 781001 | L2 | Rejected-AOC reject | |
| 3 | L3₹20.0 L+₹7.6 L (61.5%)Rejected-AOC | L3 | Rejected-AOC reject | |
| 4 | L4₹23.1 L+₹10.7 L (86.4%)Rejected-AOC | L4 | Rejected-AOC reject | |
| 5 | L5₹24.0 L+₹11.7 L (94.1%)Rejected-AOC | L5 | Rejected-AOC reject |
Tender Value
₹12.4 L
EMD Value
₹12,450
Closing Date
20 Oct 2023, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE
EWC, Bareilly
Increasing capacity of 33/11 KV S/S Sarai Talfi, Bareilly
2023_MVVNL_846485_1
31/EWC(B)/2023-24
Open Tender
Electrical Works
Item Rate
90 days
Bareilly
As per tender document
3 documents required · 3 mandatory
₹3,540
SE EWC
₹12,450
23 Jan 2024
5 Oct 2023
20 Oct 2023
5 Oct 2023
20 Oct 2023
5 Oct 2023
Amount
Loading, unloading and safe carriage of the following materials from any Electy. Store Center of Electricity store division of Bareilly zone.
M.S. Channel 125x65mm
M.S.Angle 75x75x8mm
MS Angles 50x50x6mm
33 KV Post insulator
33 KV Lightening Arrestor
33 KV 400 A Bus Isolator
33 KV VCB 800A 750 MVA
Control pannel I/C for 33 KV Single T/F
33 kv O/D CT CTR 200/100/1
11 KV VCB I/C CTR 600/300/5A
11 KV VCB O/G CTR 200/100/5A
11 KV Bus coupler
33 KV PT 33KV/110V
11 KV 3x300 mm2 XLPE Cable
11 KV 3x185 mm2 XLPE Cable
11 KV Cable jointing Kit
PCC Pole 8.5m long.
MS Channel 100x50x2028mm (For top channel & fuse set)
M.S angle lron 65x65x6mm, 2700mm long
Earthing Complete
24V Battery set with Charger
33KV Fuse Set.
11KV Disc Insulator B&S 45 KN
11 KV Disc fitting
Cost of ACSR Dog conductor
Earthing of indoor & outdoor equipments of Sub-Station after proper welding of joints and painting of earth strip above soil with proper clamp etc. as per RESPO approved drawing & resistance of earthing should be not more than 2Ω as per details given below.
Making of triangular bridge by using MS electrode, GI strip 50x6mm and GI Pipe 40 mm dia with providing of well type pipe earthing upto 15 Mtr. depth below ground level including welding etc. by boaring process at T/F neutral, LA and newly erected structure including cost of GI pipe of size 40 mm dia 15 mtr. long of ISI mark.(all the required material will be supllied by the contractor).
Supply of GI strip of size 50x6mm for earthing of all newly erected structures and equipments in switchyard including cutting, fixing & proper welding with equipments. All LA will be seprately earth also as per RESPO norms. (All the required materials will be provided by firm.)
Construction of new transformer plinth of size 4.5x3.5 Mtr. for upto 10 MVA Transfomer having depth 0.5 Mtr. below ground level & 0.5 Mtr. above ground level. Existing plinth is in very damage condition and its height is below ground level. The work including excavation of foundation. base & concreting of foundation base of CC 1:6:12 ratio (cement, fine sand & brick ballast) first class brick work of cement morter of ratio 1:4 for masonry & lintring work of transformer plinth of RCC work of ratio 1:2:4 (cement, coarse sand and store grit of 20mm using MS Bars of 10mm dia(tor) for reinforcement of linter including cutting, bending & binding of MS bars of required plinth size & shape. The work also includes laying of 2 Nos. 3.5 Mts. long rail pieces after cutting in proper size & shape & fitting etc. The plinth will be made as per RESSPO/Approved drawing suitable for 10 MVA transformer & shall be plastered of walls of ratio 1:4 (cement & fine sand)/finished on top and sides of the plinth. (all material will be provided by firm).
fabrication, erection and grouting of the following structures as per RESSPO/ Approved Drawing and its, plinth 30 cm above ground level as directed by the Engineer Incharge, Grouting of structure will be done in 1:4:8 ratio of cement, sand & coarse aggregate with material including all accessories.
Post insulator Structure
Bus Isolator Structure
33 KV VCB Structure
33 KV CT Structure
33 KV PT Structure
Fuse Set Structure
Lightening Arrestor Structure
Mounting and installation, including Mechnical & electrical fixing and adjusting of the following equipments on their respective structures including proper adjustment:
33 KV Post insulator
33 KV Bus Isolator
33 KV VCB
33 KV Fuse Set
33 KV Lightening Arrestor
Dismantling of existing following damage equipments on their structure.
33 KV Lightening Arrestor
Complete laying and termination of copper control cable from 10 MVA power T/F and 33 KV VCB in the out door switch yard in the Transformer relay control panel inside the control room including cost of all materials and labour required for proper completion of works as per RESSPO drawings.
Control Cable 4x2.5 mm2
Control Cable 2x2.5 mm2
Stringing of 33 KV Bus bar with ACSR Dog conductor including making vertical/Horizontal jumper connections through PG clamps and connecting all the equipments with each others through connecting clamps, work includes all the jumpering from bus bar. (All type of fitting, PG clamp etc. provided by Firm).
Making of M.S. Angle Ladder type frame of Angle (65x65x6mm) & M.S. Strip (50x6mm) near power transformer for power cable with concreting in 1:4:8 ratio of cement, sand & coarse aggregate and proper clamping (50x6mm) of the same with transformer cable (grouting material will be provided by The firm).
Making of M.S. Angle frame of (65x65x6mm) in the shape of "L" to connect T/F Neutral by copper flexible strip with proper clamping including cost of copper strip. Earthing of Power T/F Neutral shall be done separately including welding with M.S. bar Electrode bridge 1 No. after making in triangular shape and proper connection with well type earthing etc. Grouting of structure will be done in 1:4:8 ratio of cement, sand & coarse aggregate (grouting material will be provided by The firm).
Laying of 11KV cable of different size from power T/F to control room I/C and control room to D/P outside Sub-Station over a pad of river sand . Cable shall be laid 500mm below the ground in the yard by covering three sides with Ist Class brick and Ganga sand (All type laying material will be provided by the Firm except 11 KV cables ).
11 KV Cable hoisting with MS Pipe in cost of material.
Erection and grouting of double pole structure of PCC Poles/S.T. Pole including stays for 11KV out door feeders, complete in all respect as per RESSPO drawing along with grouting material about 3 meter 4" dia G.I. pipe along with required elbow shall be provided at D/P for power cable including provision of 02 Nos. feeders name plate on D/P.
Erection of 11 KV incoming, outgoing and bus coupler panels (with testing & setting of relays) in substation control room including grouting of Anchor bolts of panel and making of pocket for power cable to insert in panel from trench and complete filling of control room's tranches by river sand.
Erection & testing of 1 No. double T/F Control penel in substation control room including grouting of anchor bolts of panel and making of pocket for control cable to insert in panel from trench and complete connection with new and existing both T/F, 33 KV VCB, CT etc, with filling of control room's tranches by river sand.
Repairing of existing 33KV VCB in switchyard including repalcement of all required accessories as motor, intrruptor etc. All type of material should be provided by the firm.
Termination of 11 KV Different size XLPE cable by filling 11 KV heat shrinkable type cable boxes including proper connection with LV side of T/F switch gear panels and double poles by providing suitable connectors.
Shifting and dragging of 33/11 KV 5 MVA transformer from road side to its plinth alongwith its erection including fixing of all assessories and top-up of T/F oil.
Painting of the fabicated structures with one coat of red oxide primer and two coats of synthetic enamel alumm. Paint/green paint of ISI Mark alongwith earthing strip above ground level.
Construction of Toe wall around the outdoor Switchyard of the S/S of size 0.75 Mtr At base and 0.23 Mtr. At top as per RESSPO Norms by Ist class bricks in the ratio 1:6 Base concreting of the wall to be done in ratio 1:6:12 and plaster 12mm thick in ratio 1:4. including cost of civil material.
Fabrication of switchyard fencing with wire mesh 8/10 SWG as per drawing along with Fabrication of one number gate made of MS Angle, MS channel, MS Flat, together with locking arrangement, its installation including the cost of civil material, angle 50x50x6mm, 75x75x6mm etc.
Providing and fitting of 150 W LED flood light fiting with lamp of latest design complete with De-fuser suitable for outdoor installation with IP65 enclosure (Power supply single phase 230 Volt 50 Hz) with clamps, Bend pipe, LT cable, junction box etc.
Providing of fire buckets stand ( Hut Type) made of M.S. Angle 50x50x6mm as per drawing with fabrication and grouting and painting by post office red paint and letter writing etc. complete including the cost of fire bucket-6 Nos. in the switch yard of the sub-station filled with Ganga sand.
Carriage of old scrap material from site to store center Bareilly.
Providing of rubber matting sheet 8/10mm
Bharat Trading Corporation
M/S MEGHA ENTERPRISES
M/S HINA ELECTRICALS
TYCOON ENGINEERS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .