Assistant Executive Engineer
O/o Assistant Executive Engineer PWD ELECTRICAL SUB DIVISION KOLLAM
DEPOSIT Maintenance of Mini Mast Light at various locations Under Piravanthoor Grama Panchayathu General Electrical Work
2026_PWD_852219_2
PWD/BLDG/EST/3491/2026
Open Tender
Electrical Works
90 days
Piravanthoor
Please refer tender document
9 documents required · 9 mandatory
₹625
₹7,047
2 Jun 2026
2 Jun 2026
12 Jun 2026
2 Jun 2026
10 Jun 2026
2 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1Providing Mini Mast Light | ||||||
| 1.001 | OD333674/2025-2026: Supply, installation, testing and commissioning of LED flood light with minimum system lumen of 12000 lm with nominal efficiency not less than 120 Lm/watt, CCT of 5700K, CRI :70, ingress protection should be minimum IP 66 with minimum surge protection 4KV inbuilt in driver and 10KV external inside housing with range of operating voltage 120-270 V AC .The housing should be made of die-cast aluminium housing with powder coated, heat resistant toughened glass with THD <10%, power factor >0.95, RoHS compliant, duly wired up for use on 230 V AC supply with all accessories for fixing the luminaries . Chip make Cree/Osram/lumilled/Nichea/Bridgelux.(LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer). | - | each | 8,645.21 | - | BI01010001010000000000000515BI0100001114 |
| 1.002 | OD333675/2025-2026: Supply, installation, testing and commissioning of LED flood light with minimum system lumen of 14400 lm with nominal efficiency not less than 120 Lm/watt, CCT of 5700K, CRI :70, ingress protection should be minimum IP 66 with minimum surge protection 4KV inbuilt in driver and 10KV external inside housing with range of operating voltage 120-270 V AC .The housing should be made of die-cast aluminium housing with powder coated, heat resistant toughened glass with THD <10%, power factor >0.95, RoHS compliant, duly wired up for use on 230 V AC supply with all accessories for fixing the luminaries . Chip make Cree/Osram/lumilled/Nichea/Bridgelux.(LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer). | - | each | 11,494.5 | - | BI01010001010000000000000515BI0100001115 |
| 1.003 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature
circuit breaker suitable for inductive load of following poles in the existing MCB
DB complete with connections, testing and commissioning etc. as required.
Single pole | - | each | 294.66 | - | BI01010001010000000000000515BI0100001116 |
| 1.004 | 2.10.3:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature
circuit breaker suitable for inductive load of following poles in the existing MCB
DB complete with connections, testing and commissioning etc. as required.
Double pole | - | each | 755.29 | - | BI01010001010000000000000515BI0100001117 |
| 1.005 | 2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps | - | each | 500.57 | - | BI01010001010000000000000515BI0100001118 |
| 1.006 | 2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
40 amps | - | each | 3,042.51 | - | BI01010001010000000000000515BI0100001119 |
| 1.007 | OD330976/2025-2026:Supply and providing 24 Hours analog timer for automatic ON/OFF operation of light and giving connection etc | - | each | 2,255.24 | - | BI01010001010000000000000515BI0100001120 |
| 1.008 | OD330977/2025-2026:Supply and providing 25A 2pole AC1 rated power contactor including giving connection etc as required. | - | each | 893.37 | - | BI01010001010000000000000515BI0100001121 |
| 1.009 | 90.6.5.12:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq mm | - | metre | 112.7 | - | BI01010001010000000000000515BI0100001122 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.08 MB
AFFIDAVIT.pdf
Tender Documents • 0.03 MB
PRILIMI.pdf
Tender Documents • 0.64 MB
E.pdf
Tender Documents • 0.01 MB
B.xls
Tender Documents • 0.34 MB
L.pdf
Tender Documents • 0.11 MB
IP.pdf
Tender Documents • 0.02 MB
SP.pdf
Tender Documents • 0.36 MB
T.pdf
Tender Documents • 0.10 MB
SBD.pdf
Tender Documents • 1.63 MB
Download all tender documents and submit your bid