Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.8 LAccepted-AOC 321 PATIL NAGAR BAWDHAN ROAD BAVDHAN BUDRUK PUNE MAHARASHTRA 411021 | PUNE | MAHARASHTRA | 411021 | L1 | Accepted-AOC L1 | |
| 2 | L2₹7.4 L+₹1.6 L (27.3%)Rejected-AOC 37 3488 GROUND FLOOR SUBAIDAS BLDG DESHABHIMANI KALOOR ERNAKULAM ERNAKULAM KERALA 683517 | ERNAKULAM | KERALA | 683517 | L2 | Rejected-AOC L2 | |
| 3 | L3₹8.7 L+₹2.8 L (48.1%)Rejected-AOC 41 1948 1ST FLOOR CITY MEMORIAL BUILDING T A BEERANKUNJU ROAD ERNAKULAM KERALA INDIA 682018 ERNAKULAM CITY | ERNAKULAM | KERALA | 682018 | L3 | Rejected-AOC L3 | |
| 4 | L4₹8.8 L+₹3.0 L (51.1%)Rejected-AOC ERNAKULAM | ERNAKULAM | ERNAKULAM | KERALA | L4 | Rejected-AOC L4 | |
| 5 | L5₹10.8 L+₹5.0 L (84.9%)Rejected-AOC 13 1150 1 SAUBHAGYA KANNAMMOOLA MEDICAL COLLEGE P O THIRUVANANTHAPURAM KERALA 695011 | THIRUVANANTHAPURAM | KERALA | 695011 | L5 | Rejected-AOC L5 |
Tender Value
Refer Docs
EMD Value
₹15,080
Closing Date
31 Dec 2021, 3:00 pmClosed
MANAGING DIRECTOR
CHALACHITHRA KALABHAVAN VAZHUTHACAUD THIRUVANANTHAPURAM
SITC OF UPS SYSTEM AT KAIRALI SREE NILA THEATRE THIRUVANANTHAPURAM
2021_KSFDC_462800_1
6131/T2/21/KSFDC
Open Tender
Equipments
Item Rate
14 days
THIRUVANANTHAPURAM
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,360
Yes
₹15,080
Yes
8 Feb 2022
23 Dec 2021
1 Jan 2022
23 Dec 2021
31 Dec 2021
24 Dec 2021
Amount
Supply, installation, testing and commissioning of 6kva/6kw UPS stand-alone Configuration. Single phase in and out. with indoor (IP20) with 30 Min backup battery (12v 26ahx 20 nos) @ 6 kva Load Minimum VAH 6540 per UPS SMF battery of reputed approved make exide/quanta), Input pf 0.99, it shall be 100% generator compatible, with Efficiency > 85 % and output power factor 0.8 including all accessories etc as required. The acoustic noise at 1m of the system should be<55dB.The system shall comply to IEC /EN 62040-1,2,3 and PEP Certificates, and relevant IS standard along. The system shall be true online double -conversion DSP based UPS system and also UPS shall be with automatic & manual bypass switch.The system shall have IGBT rectifier and inverter. Warranty : Three years for UPS & two years for batteries
Supply installation, testing and commissioning of 20KVA/18kW (3P-1P) On line double conversion, pure sine wave UPS having DSP control and SPWM technology with IGBT and built-in isolation transformer, with the following Specifications :Input Voltage Range 320V AC to 465 VAC at 100% Load (Ph-Ph), Frequency-50 HZ, Output voltage :230V single phase AC, 50 Hz, Front panel LCD Display, input power factor :0.98, input THDi <5% at full load, Output voltage regulation <+/-1%, THD 2% (Linear Load),THD <5% (Non-Linear load), Overload capacity: 150% for one minutes 120% for 10 minutes, efficiency Ac-AC:93% , Load crest factor : 3:1, Audible Noise: <70dB at 1meter, Operating Temperature: 0- 45°C,Temperature compensated three stage battery charging. Offered UPS system with ISO & BIS certification. Battery bank using 24nos 12V, 65AH Quanta/ Exide battery (Total VAH 18720) for 30minute backup Warranty : Three years for UPS & two years for batteries
PEE PEE BATTERIES
HYKON INDIA LIMITED
SUPRA HI TECH ELECTRO EQUIPMENTS PVT LTD
ADIRO ENERGY PVT LTD
stage.html
html • 0.05 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_662285.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .