Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.1 LAccepted-AOC BELONIA SOUTH DIST PIN 799155 | BELONIA | SOUTH TRIPURA | TRIPURA | 799155 | L1 | Accepted-AOC Accepted as lowest bidder | |
| 2 | L2₹35.1 L+₹1.0 L (3.06%)Rejected-Finance JAGAHARIMURA AGARTALA WEST TRIPURA | AGARTALA | WEST TRIPURA | TRIPURA | L2 | Rejected-Finance Higher rate compare to L1 Bidder | |
| 3 | L3₹37.0 L+₹2.9 L (8.50%)Rejected-Finance | L3 | Rejected-Finance Higher rate compare to L1 Bidder |
Tender Value
Refer Docs
EMD Value
₹74,646
Closing Date
24 May 2021, 5:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Dgm EDI banamalipur
DGM EDI banamalipur Agartala
Construction of 2X200 KVA SS at CM Bunglow
2021_POWER_19138_1
DGM_ED-I_TSECL_2021-22_02
Open Tender
Electrical Works
Item Rate
90 days
Work
As Per NIT
3 documents required · 3 mandatory
₹10,000
₹74,646
Oo AGM ECI Agartala
18 Jun 2021
11 May 2021
25 May 2021
12 May 2021
24 May 2021
19 May 2021
12 May 2021 - 17 May 2021
17 May 2021
180 days
Amount
SCHEDULE - A (Supply)
Supply of 100X50X50X6 mm M.S. Channel ,.confirming to IS:2062 Grade 'A' quality , to be used for Distribution Sub-station Structure and erected on Steel Tubular Pole/PCC pole/RS Joist Structure with the help of MS Clamp,Made of 50X6 mm MS Flat with required Nuts & Bolts as direction of Engg-in charge.
Supply of 75X40X40X6 mm M.S. Channel confirming to IS:2062 Grade 'A' quality,to be used for Sub-Station structure and erected on Steel Tubular Pole/PCC pole/RS Joist Structure with the help of MS Clamp,Made of 50X6 mm MS Flat with required Nuts & Bolts as direction of Engg-in charge.
Supply of 2- pole, 3-phase, 12 KV, 200 Amps manually Gang operated Air Break switch, 2-post vertical type single break, complete with post insulation for operation in 11 KV, 50 Hz AC system as per relevant IS with supply of clamps, nuts & bolts, bimetalic lugs etc as reqd as per direction of Engg-in charge.
Supply of triple-pole , 3-phase, 12 KV, 200 Amps Drop out fuse unit for operation in 11 KV, 50 Hz AC system as per relevant IS with supply of clamps, nuts & bolts, bimetallic lugs etc as reqd as per direction of Engg-in charge.
Supply of 3- Phase, 3 core 6.35/11 KV 120 sqmm XLPE insulated & Insulation screened Aluminium Power Cable Conductor as per IS 7098/II/1985 and latest emendments.
Supply of 125 mm outer dia HDPE pipe as per PE-6 of different length as per requirement of TSECL using for boring & cable riser to overhead lines
Supply and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitale for 120 mm 3 core, XLPE aluminium conductor cable of 11 KV grade as required.
Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for 3 core,120 sqmm XLPE aluminium conductor cable of 11 KV grade as required.
Supply of fabricated clamps of assorted size of MS flat (50x6 mm)
Supply of Nuts and Bolts (Assorted) i/c washer ,ISI marked machine made
Supply of 120 sqmm Bimetallic Lugs
Supply of 500 Amps Cut-Out
Supply of 4 Way(1 incoming, 3 Outgoing) HT Kiosk/ 11 KV outdoor Type Feeder pillar made of 10 SWG MS Sheet complete with Aluminium Busbar,HT Insulator etc. as required provided with locking system and painting,to be filled in structure of MS Angle(50x50x6 mm) & MS flat(40x6 mm) including supply of MS Angle and MS Flat as required and concreting the each leg of Kiosk in the ratio 1:2:4 (1 cement: 2 river sand: 4 Jhama bricks aggregate with 20 mm nominal size) including centering,Shuttering & disposal of Excess Excavated Soil.
Design ,Engineering and commisioning of LT Control panel Kiosk with provision of 03 nos.( 01 no. spare), 250 Amp triple pole MCCB, 2 nos. ( 1 no. spare) ,400 Amp or above Automatic changeover switch, 2 nos.( 1 no. spare), 200 Amp, 3 pole MCCB, Digital Voltmeter & Ammeter, provision for installation of CT Meter operated Energy Meter as Required
SCHEDULE -B (Erection)
Erection of 11.00 Mtr. Long steel tubular pole at any kind of soil upto depth of 1/6 th of pole height, including excavation of earth , refilling the pit with soil upto ground level, ramming and making complete in all respect.
Erection of stay set direct in earth complete with 19 mm x 1800mm long stay road, anchor plate of size 300 x 300x 8 mm, turn buckle, 7/3.15 mm dia GI strande stay wire and strain insulator in/c MS clamp & MS nuts bolts etc as reqd. and making complete in all respect.
Manuallly/ Machine digging / drilling horizontally or diagonali direction for road crossing / Water supply line/ Telicomunication line / Gas pipe line etc. including Laying of 64 to 200 mm dia G.I/ HDPE pipe direct into the earth at a depth of minimum 1100 mm below the ground surface with out effecting the exisiting road and laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade in the already laid G.I./ HDPE pipe including excavation earth for entry pit as per site condition and direction of Engineering in Charge.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of all size in the G.I / HDPE pipe for riser including tieup of pipe with pole by the help of MS flat clamp ( excluding cost of Clamp and Nuts & bolts)as required
Erection and commissioning of 200 KVA 11/0.43 KV Delta- Star oil immersed ONAN cooled outdoor type, 3-phase, 50 Hz Distribution Transformer with filling of EHV grade insulating oil & complete with conservator, breather etc as per relivent IS 2026: 1977-81, 1866/ 10593/ 9434/ 6792/ 2362 and other relevent IS.
Erection of 2- pole, 3-phase, 12 KV, 200 Amps manually Gang operated Air Break switch, 2-post vertical type single break, complete with post insulation for operation in 11 KV, 50 Hz AC system asper relevant IS with supply of clamps, nuts & bolts, bimetalic lugs etc as reqd as per direction of Engg-in charge.
Erection of triple-pole , 3-phase, 12 KV, 200 Amps Drop out fuse unit for operation in 11 KV, 550 Hz AC system asper relevant IS with supply of clamps, nuts & bolts, bimetalic lugs etc as reqd as per direction of Engg-in charge.
Erection of triple-pole , 9 KV, 5 KN, Polymeric Lightening Arrester suitable nominal system voltage 11 KV, 50 Hz AC system, creepage distance 600 mm, confirming to IS: 3070/1985.
Laying & stringing of ACSR 6/1/3.35 mm conforming to confirming to IS: 398(Part-II) 1996 with latest amendments if any in/c hoisting, jumpering etc as per direction of Engg-in-charge
Erection of MS channel Cross-Arm , 2.8 mtr. Long 100x50x50x6mm ( Excluding the cost of Bkt, Clamp, Nuts & Bolts)
Erection of MS channel Cross-Arm ,4 mtr. Long 100x50x50x6mm ( Excluding the cost of Bkt, Clamp, Nuts & Bolts)
Erection of MS channel Cross-Arm , 2.8 mtr. Long 75x 40 x40x6mm ( Excluding the cost of Bkt, Clamp, Nuts & Bolts)
Erection of MS channel Cross-Arm , 4 mtr. Long 75x 40 x40x6mm ( Excluding the cost of Bkt, Clamp, Nuts & Bolts)
Fabrication of Cross-Arm by MS Channel/ Angle as per specification
Erection of 11 KV Pin Insulator
Fiting fixing of LT Cut outs(300 Amp), set of three on wooden plank of size(24"X10"X1.5") & cable connections with termination by lugs complete(i/c supply of wooden plank,screws &MS Clamps excluding cost of thimble)
Earthing with GI pipe 2.5 mtr. Long nd 40 mm dia including excavation, refilling with alternate layer of salt & Charcoal as per drawing ( Including Supply of G.I. pipe,Salt and Charcoal, GI wire nuts & bolts etc as required)
Laying of 8 SWG GI wire at 300mm below the ground level for earthing of Sub-Station equipments from the earth electrode.
Providing of pre-cast cement concrete cable identification route marker ( 1 cement: 2 coarse sand : 4 graded stone aggregate 6mm nominal size) rainforced with 1.6 mm dia mild steel wire including centring an shuttering, roughening cleaning , fixing and finishiing in cement mortar 1:3 (1 cement : 3 fine sand) etc. complete, excluding the plastering of jambs, sills and soffits as per design, drawing and specification of TSECL. The marker shall be embossed " DANGERS: TSECL, ELECTRIC POWER CABLE" with Black colour letter (both side) The visible part shall be painted with Yellow colour japan paint. ( 1 cement: 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) reinforced with 1.6 mm dia mild steel wire including centring and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3 ( 1 cement: 3 fine sand)etc. complete, excluding the plastering of jambs, sills and soffits.
Grouting Steel Tubular pole with CC work of ratio1:2:4 ( one cement: two sand: four Jhamma Bricks) aggregate of 20 mm nominal size includung supply of cement,sand and brick aggregate complete with excavation,reffiting of earth ramming along with centering and shuttering as [email protected] cum/pole as per direction of Engg-in-Charge
Erection of 4 Way(1 incoming, 3 Outgoing) HT Kiosk/ 11 KV outdoor Type Feeder pillar made of 10 SWG MS Sheet complete with Aluminium Busbar,HT Insulator etc. as required provided with locking system and painting,to be filled in structure of MS Angle(50x50x6 mm) & MS flat(40x6 mm) including supply of MS Angle and MS Flat as required and concreting the each leg of Kiosk in the ratio 1:2:4 (1 cement: 2 river sand: 4 Jhama bricks aggregate with 20 mm nominal size) including centering,Shuttering & disposal of Excess Excavated Soil.
Design ,Engineering and commisioning of LT Control panel Kiosk with provision of 03 nos.( 01 no. spare), 250 Amp triple pole MCCB, 2 nos. ( 1 no. spare) ,400 Amp or above Automatic changeover switch, 2 nos.( 1 no. spare), 200 Amp, 3 pole MCCB, Digital Voltmeter & Ammeter, provision for installation of CT Meter operated Energy Meter as Required
SCHEDULE-C (Carrying)
Carriage of 11/0.43,3 phase,200 KVA Distribution Transformer by mechanical Transport from the Site/Store/workshop/ M.M. Store Sub-Division,A.D. nagar to working site including loading,Unloading & placing on Base etc. as required,upto lead range of 25 Km
Carriage of materials such as cable,AAC,AAAC,ACSR,GI Wire wire,Stay set,Insulators etc. by mechanical Transport from the Electrical sub-Divisional site / M.M. Store Sub-Divsion,A.D, Nagar to working site i/c loading,unloading & stacking as required ,upto lead range of 25 Km
Carriage of 11.00 mtr. Length of Steel tubular poles by mechanical Transport from Electrical sub-Divisional site/ M.M. Store Sub-Divsion,A.D, Nagar to working site including loading,Unloading & Stacking etc. as required, upto lead range of 25 km
KAJAL DAS
M/S GHOSH ELECTRICAL ENGINEERING
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .