Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.7 LAccepted-AOC GANDHI CHOWK LANSDOWNE DISTT PAURI GARHWAL 246155 | LANSDOWNE | PAURI GARHWAL | UTTARAKHAND | 246155 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹7.4 L+₹65,510 (9.75%)Rejected-Finance | L2 | Rejected-Finance Being Not Lowest | |
| 3 | L3₹7.4 L+₹73,022.20 (10.9%)Rejected-Finance 2 2407 GILL COLONY NARAINPURI SAHARANPUR UP | SAHARANPUR | SAHARANPUR | UTTAR PRADESH | 247001 | L3 | Rejected-Finance Being Not Lowest | |
| 4 | L4₹7.8 L+₹1.1 L (15.7%)Rejected-Finance 199 79 SADAR BAZAR LANSDOWNE TAHSIL LANSDOWNE | L4 | Rejected-Finance Being Not Lowest |
Tender Value
Refer Docs
EMD Value
₹12,560
Closing Date
10 Sept 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Lansdowne
GE Lansdowne Distt-Pauri Garhwal Pin-246255
PROVN OF PATHWAY/STAIRS FROM KL GROUND TO B COY (OTM) (120 MTR) AT GRRC UNDER GE LANSDOWNE
2020_MES_342627_3
8530/E8
Open Tender
Civil Works
Item Rate
180 days
GE Lansdowne
Please Refer Tender Documents
6 documents required · 6 mandatory
₹500
GE Lansdowne
₹12,560
23 Sept 2020
26 Aug 2020
12 Sept 2020
26 Aug 2020
10 Sept 2020
28 Aug 2020
60 days
Amount
Excavation in trenches not exc 1.5m wide & not exc. 1.5 in depth in soft/loose soil for foundation laying cable etc exc 10 sqm on plan and n exc 1.5m in depth and getting out in soft loose soil complete all as specified and directed
Surface excavation in soft/loose soil n. exc 30 cm deep and averaging 15 cm deep and getting out complete all as specified and directed
M&L PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) as in foundation/filling and mass concrete all as specified and directed
M&L brick work with old size sub class B bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified & directed
Removing excavated material to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all a specified & directed.
M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surface, finished fair and even complete all as specified and directed
M&L for preparation of new plastered surface and applying two coats of cement based paint complete all as specified and directed
M & L for providing 100 mm thick cement concrete (1:2:4) type B-2 Nominal Mix (using 40 mm grade stone aggregate) as in floor, path / paving complete all as specified and directed.
M&L for 75mm thick PCC 1:4:8 type D-2 ( using 40mm graded crushed stone aggregates) as in sub base complete all as specified and directed
M&L 25mm thick cement concrete type B-0 (1:2:4) 12.5mm graded aggregate as in sub base for floors complete all as specified and directed.
Supply & fix kota stone slab 20-25 mm thick as in floor etc over and including 15mm screed bed in cement mortar 1:6 cement & jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing & polishing to achive mirror finish an roughning the surfaces complete all as specified and directed .
Supply & fix kota stone slab 20-25 mm thick as in skirting/dado etc over and including 15mm screed bed in cement mortar 1:6 cement & jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing & polishing to achive mirror finish an roughning the surfaces complete all as specified and directed .
M & L for plain cement concrete (1:2:4) (using 12.5 mm graded stone aggregate), cills, steps, parapets , copings,bound stone, bed plates, hold fast and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed.
Supply, laying, commisioning and testing of 1.1 KV grade XLPE insulated PVC sheathed steel armoured aluminum stranded conductor LT UG cable ( Conforming to IS 1554) in trenches / ducts / through GI pipes under roads of size 6 sqmm 4 core complete all as specifed and directed. Note:- The earth work, GI pipe shall be measured and paid sepretely under appropriate item of Sch A
Supply, fixing & testing 35 W LED road way light fitting mounting type made out of one piece in pressure die-cast aluminium, alloy powder coated housing enclosed with glass cover in frame fitted luminaries complete with electronic driver and all accessories suitable for & including lamp 35 W with suitable No's of LEDs incl external/internal SPD of 2 KV. The fitting shall IP 65 protection, duly prewired complete with and including connecting the fitting to bus bar box/Main switch/pole box with required lenth of 2.5 Sqmm three core PVC insulated and unsheathed copper conductor copper conductor cable RYB color incl 32 mm dia light grade GI pipe bracket (if required) 1.2 mtr long bend to shape with 2 two coats of synthetic enamel aluminium paint over one coat of red oxide primer incl nuts, bolts and clamps complete all as specified and directed. Make :- Phillips Cat No BRP050 LED 036 CW R1 MF PC S1 PSU GR or equivalent make in Havells/Wipro
M&L for time switches astronomical type (Having longitude and latitude of indian cities in memory) 415 volt Three phase of 20 Amps rating contractor with controller MCB four pole 40 Amps inside PVC polycarbonate enclousure of size 30cm X 30 cm X 10 cm with locking arrangement complete including mounting/ grouting in earth or fixed to pole/LT panel with MS clamps 40x5 mm FI ,nuts ,bolts and washers .and painting with two coats of synthetic enamelled paint over one coat of red oxide Zn chrome primer on clamps complete all as specified and directed. Make of Box:- Sintax/Hensel/EPP Make of MCB/Contactor/Timer Switch:- Havells/L&T/Schiender
Supply, fixing/errecting swaged swan neck type steel tubular pole in true vertical position type 410SP-22, 8.5 mtr long with cast iron base plate, finial taper plug, bolts, nuts and hook for earth wire duly ISI marked as per IS:2713 including two coats of synthetic enamel black bituminiuous paint internally/externally upto planting depth and remaining portion with 2 two coats of synthetic enamel aluminium paint over one coast of red oxide primer, marking MES number to a height of 1.0mtr complete all as specified and directed. Note : The necessary excavation, earth wk and PCC work will be measure under relevant itme of sch 'A'
Excavation in trenches in soft/disintegrated soil not exc 1.5 m wide and not exceeding 1.5m in depth for laying UG cable/foundation/for poles etc complete all as specified and directed.
Returning filling in soft/disintegrated soil including spreading levelling watering and well ramming in layers n.exc 25cm each layer complete all as specified and directed.
Removal of excavated surplus soft/disintegrated soil to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
Supply and spread fine river sand in trenches as cushioning to underground cable on top and bottom of cable all as specified (measurement to be taken after punning down).
M&L for cable protection bricks common burnt clay sub class 'B' designation 75 for protection of UG cable laid in trenches all as specified and directed.
S & F Loop in and Loop out Box (Pole Box) made out of ploycarbonate front operable hinged from side of size 200x140x95 mm having 4 pole cable connector (for cable in out function) fixed inside box with insulator support and 01 nos MCB SP 06 Amp fixed inside box complete to pole for street light fitting with mS clamps 40x5 mm GI nuts, bolts and washers complete all as specified and directed. Make of Box:- Sintax/Hensel/EPP Make of MCB:- Havells/L&T/Schiender
PCC 1:4:8 type D-2, using 40mm graded stone aggregate in foundation of pole as in mass concrete complete all as specified and directed.
PCC 1:3:6 type C-1 (Using 20mm graded stone aggregate) as in plinth block of pole and stay including necessary frame work complete all as specified and directed.
Earthing complete with galvanized earth plate electrode 600x 600 x 6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below ground level connected to galvenised earth lead wire of 4 mm dia by means of nuts, bolts, washes of galvanized iron or steel all as shown in electrical plate No 5 and testing on completion including adequate charcoal dust comman salt necessary excavation & earth work PCC(1:3:6) type C-1 pit with precast RCC Cover slab 40 mm thick in PCC(1:2:4) type B-0 reinforced with 6 mm dia MS bars @ 100 mm c/c both ways with funnel wire mesh and 20 mm dia GI pipe medium grade as watering pipe and connecting the GI wire to pole complete all as specified and as directed.
Supplying, laying & jointing GI water tubing, 40 mm bore, light grade as in sleeving etc laid in trenches / pole post /under culvert/ under road incl nut,bolts and clamps for fixing to pole etc. complete all as specified and directed .
NAND KISHORE ANIL KUMAR
RAMAPATI ENGINEERING SERVICES
M/S Balaji Builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .