| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.6 LAccepted-AOC 13 THAKKAR PLOT DEEPAK KUNJ PORBANDAR 360575 | PORBANDAR | GUJARAT | 360575 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹45.0 L+₹2.1 L (4.94%)Rejected-AOC 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹46.7 L+₹3.9 L (8.99%)Rejected-AOC INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L3 | Rejected-AOC REJECTED | |
| 4 | Rejected-Technical PLOT NO P PARASNAGAR NR SBI BANK NARSANG TEKRI PORBANDAR 360 575 | PORBANDAR | GUJARAT | 360575 | - | Rejected-Technical REF TECHNICAL EVALUATION DOCUMENTS | |
| 5 | Rejected-Technical | - | Rejected-Technical REF TECHNICAL EVALUATION DOCUMENTS |
Tender Value
Refer Docs
EMD Value
₹87,000
Closing Date
14 Sept 2022, 6:00 pmClosed
GE I CG Porbandar
Military Engineer Services, GE I CG Porbandar, DHQ No. 1, Opp. Birla Cement Factory, Porbandar-360575
REPAIR MAINTENANCE OF INTERNAL ELECTRIC SUPPLY EXTERNAL ELECTRIC SUPPLY AND WATER SUPPLY AT CG JETTY AND CG DHQ NO1 PORBANDAR AND ANNUAL MAINTENANCE CONTRACT OF STAND BY DG SET AT CG JETTY AND CGDHQ NO 1 PORBANDAR UNDER GE I CG PORBANDAR
2022_MES_547842_1
8766
Open Tender
Civil Works
Item Rate
Porbandar
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
GE I CG PORBANDAR
₹87,000
Yes
3 Oct 2022
26 Aug 2022
15 Sept 2022
26 Aug 2022
14 Sept 2022
9 Sept 2022
Amount
SCHEDULE 'A'
M&L for dehydration/centrifuging of transformer oil minimum 3 cycles to achieve dielectric strength 50 kV in 2.5 mm gap electrode with centrifuging machine at site and testing of transformer oil before and after de- hydration complete all as specified and as directed at site. Locations CG Jetty Pbr/CGDHQ No 1 (a) Oil topping up shall be measured seperately. (b) Contractor has to make his own arrangement for oil filteration plant.
M&L for topping up/replacement of with new transformer oil upto a required level ( 50 KV di-electric strength in 2.5 mm gap electrode to with stand for one minute) in any type and capacity of transformer complete all as specified and directed at site. Locations CG Jetty Pbr/CGDHQ No 1 (a) The transformer oil shall be ISI marked and brought at site in sealed container only. (b) Necessary T & P for collection of transformerr oil samples testing kit and filteration plant. Also damed to be included in quoted rate.
Supply and fix in replacement of breather for transformer oil conservator tank including filled with silica gel for transformer of following ratings complete all as specified and as directed. Locations ICGAE/CG Jetty Pbr/CGDHQ No 1 (a) 100 to 250 KVA
(b) 315 to 500 KVA
S&F in replacement Silica of Gel (Moisture absorbent chemical ) for breather of transformer 11 KV /433 Volt of any make / rating complete all as specified and as directed by engineer-in charge Locations ICGAE/CG Jetty Pbr/CGDHQ No 1
S&F in replacement of oil temperature indicator gauge suitble for transformer of capacity 11KV/433 Volt complete all as specified and as directed
Supply and fix in replacement of HT bushings of transformer 11 KV/ 433 Volts including by disconnecting existng HT connectin, drain out oil up to safe working level and chnging of existing HT bushing with stud, seal etc of 160 KVA TO 630KVA capacity all as specified and as directed.
Dismantling of LT bushing of transformer including metal and rubber parts and complete with new metal and rubber parts of any size and shape required for transformer from 160 KVA to 630 KVA complete all as specified and as directed. Locations CG Jetty Pbr/CGDHQ No 1
Supply and fix in replacement of LT stud of suitable size for transformer of 11/433 Volt for following rating and make all as specified and directed . Locations: ICGAE/CG Jetty Pbr/CGDHQ No 1 (a) 100 to 250 KVA
(b) 315 to 500 KVA
Material and labour for heat shrinkable HT, 11 KV , outdoor type, cable end joint suitable for 11 KV, 3 Phase, AC, 50 Hz, , XLPE Cable including jointing materials complete including taking down old end joints all as specified and as directed for following size. Make: 3M/Denson/Raychem RPG (a) 95 Sqmm 3 core
(b) 120-185 Sqmm 3 core
(c) 240-300 Sqmm 3 core
Material and labour for heat shrinkable HT, 11 KV , indoor type, cable end joint suitable for 11 KV, 3 Phase, AC, 50 Hz, , XLPE Cable including jointing materials complete including taking down old end joints all as specified and as directed for following size. Make: 3M/Denson/Raychem RPG (a) 95 Sqmm 3 core
(b) 120-185 Sqmm 3 core
(c) 240 sqmm to 300 sqmm 3 core
Material and labour for heat shrinkable HT, 11 KV , Straight Through cable joint suitable for 11 KV, 3 Phase, AC, 50 Hz, , XLPE Cable including jointing materials complete including taking down old end joints all as specified and as directed for following size. Make: 3M/Denson/Raychem RPG (a) 95 Sqmm 3 core
(b) 120-185 Sqmm 3 core
(c) 240-300 Sqmm 3 core
S&F in replacement air break switch triple pole, 11KV, mechanically operated mounted on polymeric insulators and steel frame, with operating mechanism worked from ground level, for current rating up to 200 amps complete with including insulators horizontal /vertical rod and operating pipe of suitable size and length including taking down the old unserviceble air break switch,jumper connections and reconnecting of suitable size and length and making connection to new AB switch gang operated complete all as specified and as directed. Make: Jaipuria/ Atlas/Pactil
S&F in replacement HT 11 KV drop out fuse assembly with polymericinsulator and base including fuse tube, fuse carrier top connectors incomming and out going connectors as as specified and as directed by EIC. Note:Rate include taking down existing unserviceble/ Faulty DO fuse assembly and fix the new one and make the incomming and out going connections and switch on the supply through the new DO fuse assembly all as directed by EIC Make: Jaipuria/ Atlas/Pactil
M&L for preventive maintenance of HT ring main unit at main receiving substation as per manufature specification ,work is to be carried out with prior intimation, and taking shut down of Ring main unit , earth the unit completly all as specified and as directed by Engineer In charge. Scope of work consists of following:- (a) Check and clean termination and bushing compartment (b) Checking of sealing of gland plate area (c) Checking of mechanical interlock (d) Check close and trip coil condition and gap setting (e) Checking of control circuit , fuses and Electrical interlocks (f) Following test should be carried out at site (i) Test the insulation testing of each Breaker/Isolator (ii) Test Test contacts of breaker and isolators (iii) Check /Reset the relays (g) Checking/Testing of Relays as per following (i) Functional verification of Indivitual feeder by switch On /Off by both incomming so as to confirm with both incomming unit is functional (ii) Check the auxiliary supply and control voltage (iii) Check the power pack unit and its Voltage. (iv) Check the CT connections , inspection and testing of closing and trip coil by using external test kit . Note: Contractor has to submit the inspection report to depatment after completion of work
M&L for Maintenance/Over hauling of HT VCB 11 KV (1 nos incoming, 1 Nos outgoing) by taking shunt down with prior intimation and cleaning of HT VCB by using air blower , tightning the control circuit , Checking the all fuses , to ensure the smooth functioning of HT VCB by employing the Skilled trades man and helper all as directed by Engineer -In - Charge. Location : DHQ No-1 & CG Jetty Porbandar Note: Rate Include following (i) Replacement of small piece of wire upto size of Max length 5 Mtrs and replacement of unseviceble indicator lamps asper colour code allas specified and as directedby Engineer - In - Charge. (ii) Rack out /Down the HT VCB kept in Test position , Check the megger value of VCB terminals with body by suitable HT megger of range 5000 Volt and check the servicebility of earthing connection by Earth megger note down the readings.
M&L for Maintenance/Over hauling of HT VCB 11 KV at CG Jetty Porbandar (1 nos incoming, 2 Nos outgoing) by taking shunt down with prior intimation and cleaning of HT VCB by using air blower , tightning the control circuit , Checking the all fuses , to ensure the smooth functioning of HT VCB by employing the Skilled trades man and helper all as directed. Note: Rate Include following (i) Replacement of small piece of wire of area up to 1.5 sqmm Control Ckt cable) of Max length 5 Mtrs and replacement of unseviceble indicator lamps asper colour code allas specified and as directedby Engineer - In - Charge. (ii) Rack out /Down the HT VCB kept in Test position , Check the megger value of VCB terminals with body by suitable HT megger of range 5000 Volt and check the servicebility of earthing connection by Earth megger note down the readings.
Supply and fix in replacement of charging motor suitable for 11 KV VCB 800 Amps as per existing make and model and directed at site.
Supply and fix in replacement of closing coil 24Volt DC suitable for 11 KV VCB 800 Amps as per existing make and model and directed at site.
Supply and fix in replacement of Tripping coil 24Volt DC suitable for 11 KV VCB 800 Amps as per existing make and model and directed at site.
Supply and fix in replacement of vacuum interuptor for 11 KV , 1250 A , 25 KA type VG2 PT no. DRCVG-01,HSN No. 85389000 and as directed.
Supply and fix in replacement of Finger contacts for 2 Nos suitable for 11 KV VCB 800 Amps as per existing make and model and directed at site.
Supply and fix in replacement of auxillary metal contacts suitable for 11 KV VCB 800 Amps as per existing make and model and directed at site.
S&F in replacement of indiction LED lights for each phase of 230Volt complete all as specified and as directed
S&F in replacement of indication panel suitable for 11 KV VCB 800 Amps as per existing make and model and directed at site.
S&F in replacement of master Trip Relay 110volt DC suitable for 11 KV VCB 800 Amps as per existing make and model and directed at site. complete all as specified and as directed
S&F in replacement of Auxilary Relay 110 volt DC suitable for 11 KV VCB 800 Amps as per existing make and model and directed at site. complete all as specified and as directed
S&F in replacement of Lightining Arrestor suitable for 11 KV system as per existing make and model, completed all as specified and directed.
S&F in replacement busbar spout top for RYB suitable for 11 KV VCB 800 Amps as per existing make and model and directed at site. complete all as specified and as directed
S&F in replacement busbar spout Bottom for RYB suitable for 11 KV VCB 800 Amps as per existing make and model and directed at site. complete all as specified and as directed
S&F in replaecment in replacement of space heater and Thermostate set suitable for 11 KV VCB 800 Amps as per existing make and model and directed at site. complete all as specified and as directed
Supply and fix in replacement Epoxy cast CT rating100/1-1 Amp, 10 VA , Class E, 5P10 of mould type suitable for 11 KV VCB 800 Amps as per existing make and model and directed at site.
M&L for fabrication work such as cutting moulding welding and painting for making of MS stand with ms plate for drawout VCB indoor trolly including with four nos wheel with suitable size bearing,inclduing with fixing accessories and painting complete all as specified and as directed
M&L for applying two coats of synthetic enamel paint on site,including preparation of rusted surface of transformer of any capacity and writing SM No./MES No.complete all as specified and as directed.
Excavation in trenches not exc 1.5 m wide and not exc 1.5m in depth and getting out in Soft/ Loose soil and including taking out of PCC cable cover and getting out complete all as specified and directed
Returning filling in including spreading levelling watering and well Ramming in layers not exc 25 cm thick complete all as specified and directed
Removing excavated material not exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified.
Taking out unservicable LT UG cables of any sizes from trenche (Location of DHQ No 1/ICG Jetty) complete all as specifed and as directed
Supply & Lay in replacement of XLPE insulated, steel armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of cross-sectional area for following size of cable Note : (i)Removing of interlocking/Paverblocks, tiles and refxing with the same location and making good the distrubed surface is deemed to be included in quoted rate. (ii) Fixing accessories for cable layingsuch as clamps and nut bolts are to be included in quoted rate. (iii) Necessary earth work for lying of cable shall be measured and paid saparetely. Make: Polycab/ Asian/ Gloster/Havells/KEI (a) 10 Sqmm 4 Core
(b) 16 Sqmm 4 Core
(c) 25 Sqmm 4 Core
(d) 50 Sqmm 3.5 Core
(e) 95 Sqmm 3.5 Core
(f) 400 Sqmm 3.5 Core
Supply and Lay in replacement of OD Double Wall Corrugated (DWC) high density polythene pipes conforming to IS 14930(part I & II) having corrugation on the outer wall and plain surface on the inner wall for protection of underground Cable with all fittings laid in trenches/road/nallah or fixed along wall poles or laid under floor for the following sizes complete all as specified and as directed. Note: (i) Fixing accessories for pipe laying such as clamps and nut bolts are to be included in quoted rate. (ii)Excavation and earthwork shall be measured and paid separately) Make: Rex/Poly/Geminie a) 90 mm Outer dia
b) 63 mm Outer dia
M&L for Cutting & removing existing joint and supply, jointing and testing straight through Hot shrinkable cable joint including all materials and accessories suitable for 3.5 core XLPE cable of 1100 volts grade complete all as specified and as directed. Note : Excavation and Earthwork shall be measured and paid seperately. Make: 3M/Denson/Raychem RPG a) 25 Sqmm to 50 Sqmm
70 Sqmm to 150 Sqmm
185 sqmm to 240 Sqmm
Servicing and repair of APFC panel upto 200 KVAR by replacement of worn out spare parts and cleaning of the serviceable contactors and tightning/checking of all internal electical connections and accessories to maintain PF not less than 0.98 by adjusting/ calibrating the APFC relay of any type complete all as specified and as directed Note: Defective parts if any will be measured and paid seprately
Supply only items for APFC Panel, complete all as specified and as directed (a) MCB TP 25/40 Amp, 10 KA, 'C' series. Make: Merlin Garin/L&T/Legrand
(b) Heavy duty gas filled Capacitor,1 to 4 KVAR, 440V, 3phase, 50 Hz. Make: L&T/BCH/EPCOS
(c) Heavy duty gas filled Capacitor,5 to 15 KVAR, 440V, 3phase, 50 Hz. Make: L&T/BCH/EPCOS
(d) Heavy duty gas filled Capacitor,20 to 50 KVAr, 440V, 3phase, 50 Hz. Make: L&T/BCH/EPCOS
(e) Contactor TP 32/40 Amp. Make: L&T/C&S/CG
( f) Relay 6 stage Make Legrand/L&T/ABB/BCH/Neptune
M&L for preparation of old/rusted painted surface of outdoor type/indoor LT panel with sand paper/scrubing of dust etc before painting the panel and painting with one coat of red oxide paint and one coat of syenthtic anamel paint complete all as specified and directed. Location DHQ No1/CG Jetty Pbr Note: Minor repair/ replacement of hinges suitable for screw fastners and fixed in original position
S&F in replacement of LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. Location DHQ No1/CG Jetty Make: Wipro/Philips/GE
S&F in replacement of LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. Location DHQ No1/CG Jetty Make: Wipro/Philips/GE
S&F in replacement of LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp. Location DHQ No1/CG Jetty Make Wipro/Philips/GE
Servicing of DG set ('C' Check) of Cap 20-25 KVA by Rep of authorised service centre as per manufacturer manual and checking of fuel supply system, Lubrication system, cooling system, battery ignition system and rectification of defect if any and including replacement of following, complete all as specified and directed (a) Lub oil filter. (b) Lubrication oil. (c) Fuel filter. (d) Coolent top up. Note: Defective parts if any other than listed at (a) to (d) above will be measured and paid separately Make of DG set: Mahindra/ Kirloskar
Supply only parts/ Items of DG set 20-30 KVA a) V belt
b) Hose pipe set
c) Battery Terminal
d) Engine Oil 20W / 40 Make : Castrol/Servo/IOC/HP
e) Coolant
f) Radiator servicing complete
g) HWT Switch
h) VDO Oil Pressure sensor cum Switch 0-7 BA
i) Water Pump Assembly
j) DG controller.
k) Fuel Return Pipe
l) Fuel Supply Pipe
m) Pipe EGR to EGR valve
n) AVR of DG for 20/25 KVA capacity including with connection complete all as specified and as directed
Dismantling cross-arms of MS,channel or angle sections & earth wire etc complete and setting aside for re-use with in 50 m distance.complete all as specified and as directed
M&L for in replacement of Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and as directed
S&F in replacement Automatic street light switch,230 Volts,3 phase, 5 KW, 25A with contactor fitted in stainless steel enclosure including incoming and outgoing MCBs, power contactor complete 3 phase circuit board along with nautral switch fixed in repair complete all as specified and as directed. Make:- swaddep 02EC5KW 3 Phof Healer,Bajaj/Healer/Kakatiya. Make of MCB/Contactor : - L&T/BCH/Schneider.
S&F in replaecment of LED indicator lamp for RYB phase 230 Volt complete all as specified and as directed
Supply in replacement of aluminium thimble of following size complete all as specified and as directed a) 16-25 Sqmm size
b) 35-50 Sqmm size
c) 70-95 Sqmm size
d) 120-150 Sqmm size
e) 240 Sqmm size
f) 400 Sqmm size
Supply and fix in replacement PVC junction box for street light including cable connector for cable connection with IP -66 protection including fixing accessories complete all as spacified and as directed
Supply and fix in replacement of MCCB 63 Amp 3 Pole 16KA with thermal magnetic setting complete all as specified and as directed Make: ABB/L&T/Legrand
Supply and fix in replacement of MCCB 100 Amp 3 Pole 16KA with thermal magnetic operated complete all as specified and as directed Make: ABB/L&T/C&S
Supply and fix in replacement of MCCB 200 Amp 3 Pole 36KA with thermal magnetic operated complete all as specified and as directed Make: ABB/L&T/C&S
Supply and fix in replacement of MCCB 250 Amp 3 Pole 36KA with thermal magnetic operated complete all as specified and as directed Make: ABB/L&T/C&S
Supply and laying in replacement 3- layer PP-R Polypropylene random copolymer) pipes SDR 7.4 (PN16) UV stablised and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches/Wall complete all as Specified and directed. Make: SFMC / VECTUS / RELIANCE / AKG / SFC a) 25 mm outer dia
b) 50mm outer dia
c) 63mm Outer dia.
M&L for in replacement of gate valve of PPR pipe for following outer dia complete all as specified and as directed Make SFMC / VECTUS / RELIANCE / AKG / SFC / KPT a) 25 mm
M&L for applying two coats of synthetic enamel paint on sand filteration tank of any size ,including preparation of rusted surface of poles by means of sand paper/scrubing of dust etc and applying one coat of epoxy based primer before painting complete all as specified and directed.
Dismantling the centrifugal Pump up to 10 HP including disconnecting suction and delivery line and rewinding the motor with suitable size of copper wire and reassembling after replacement of necessary spares including greasing and painting of 2 coats of synthetic enamel paint using spray machine complete all as specified and as directed.
Taking down submersible pump 3 phase, 415 Volt capacity up to 5 HP, disconnecting incomming electric connections, dismantling slots, taking out burnt windings and rewinding the motor with super enameled copper wire as per existing size including insulating material and varnishing,greasing, painting with super enameled paint as per colour code and assembling the motor after rewinding and mounting at its own position, replacing the old nut, bolts and testing all as directed.
Taking down carefully burnt out aluminium/copper point wiring (light, fan, socket or power) complete (fittings such as switches, ceiling roses, pendent, regulators, sockets, flourescent tube light fittings etc to be measured and paid for seprately) removing materials to store for schedule of credit and making good to the disturbed surfaces of walls ceilings and floors etc complete all as Specified and directed.
Disconnecting unserviceable sub main wiring of any size and including steel conduit and accessories & removing from site and making good the disturbed surfaces inclduing painting
M&L for Point wiring complete with 1.5 Sqmm single core PVC Insulated but unsheathed multistranded copper conductor FRLS cable 650/1100 Volt grade drawn through and including non metallic rigid PVC heavy duty concealed conduit, min 20mm external dia,, but shall be increased to suitable size, as per requirement in accordance with clause 19.125 of SSR Part I, ISI marked, including conduit accessories like bends,tees,junction box etc fixed concealed/recessed in wall or ceiling etc including 1.5 Sqmm earth wire, single core PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire including Modular metal flush box of suitable size for the following:- (a) One light/ Bulb Holder/fan/exhaust point / bell point controlled by one, one way switch Note: Cost of cutting / chasing on wall and making good after repair shall be deemed to be included in quoted rate . Make for cable : Havells/RR CABLES/Polycab/Anchor
(b) One light point controlled by, Two way switch
(c) One 5 pin socket outlet 5/6 amps on the same board.
(d) One 5 pin socket oulet 5/6 amps on independent board..
M&L for Point wiring complete with 2.5 Sqmm single core PVC Insulated but unsheathed multistranded copper conductor FRLS cable 650/1100 Volt grade down through and including non metallic rigid PVC heavy duty concealed conduit, min 20mm external dia,, but shall be increased to suitable size, as per requirement in accordance with clause 19.125 of SSR Part I, ISI marked, including conduit accessories like bends,tees,junction box etc fixed concealed/recessed in wall or ceiling etc including 2.5 Sqmm earth wire, single core PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire including Modular metal flush box of suitable size for the following:- (a) one 3 pin 15 or 16 Amps socket on the independent board with the required modules. Note: Cost of cutting / chasing on wall and making good after repair shall be deemed to be included in quoted rate . Make for cable : Havells/RR CABLES/Polycab/Anchor
S&F in replacement of modular type 6 A one-way SP switch, conforming to IS: 3854-1997 with finger proof terminal complete as specified and directed. Make: Anchor/ Havells/Legrand
S&F replacement of modular type 16 A one-way SP switch, conforming to IS: 3854- 1997 with finger proof terminal complete as specified and directed . Make: Anchor/ Havells/Legrand
S&F replacement of modular type 2/3 pin combined shuttered type 6 A socket conforming to IS: 1293- 2005 complete as specified and directed. Make: Anchor/ Havells/Legrand
S&F replacement of modular type 2/3 pin combined shuttered type 6/16 A socket conforming to IS: 1293- 2005 complete as specified and directed. Make: Anchor/ Havells/Legrand
S&F replacement of modular type 6A bell-push conforming to IS: 8884- 1978 with finger proof terminal complete all as specified and directed. Make: Anchor/ Havells/Legrand
S&F replacement of Bell multi music type 230 Volt complete as specified and directed. Make: Anchor/ Havells/Legrand
S&F in replacement of 120W stepped type modular fan regulator of 2 module size, conforming to IS: 11037-1984 complete as specified and directed. Make Anchor/ Havells/Legrand
S&F in replacement of 6A, 250 V high quality robust surface/flush type polycarbonate/PVC ceiling rose, conforming to IS: 371- 1979, having 2/3 terminals and outside diameter not less than 63.5 mm complete all as specified and directed. Make Anchor/ Havells/Legrand
S&F in replacement of Modular switch 2 way 6A, 1 module complete all as specified and as drirected Make Anchor/ Havells/Legrand
S&F in replacement of PVC Modular surface box of following size complete all as specified and as directed Make: Anchor a) 1 or 2 Module of size 85x 85 mm
b) 3 Module of size 85x 115 mm
c) 4 Module of size 85x 145 MM
d) 6 Module of size 132x 135 mm
S&F in replacement of Modular cover plate with frame of following size complete all as specified and as directed Make: Anchor a)1 or 2 Module of size 85x 85 mm
b) 3 Module of size 85x 115 mm
c) 4 Module of size 85x 145 MM
d) 6 Module of size 132x 135 mm
M&L for point wiring complete with copper conductor 2.5 sqmm single core PVC insulated but unsheathed multistranded conductors FRLS, 1100 Volts grade, drawn through existing conduit and including 2.5 sqmm PVC insulated but unsheathed multi stranded copper conductor FRLS cable as earth continuity wire with cover plate fixed on existing terminal boxes,complete all as Specified and directed. Make for cable: Polycab/RR/ANCHOR/Havells Note: (i) Existing MS sunken terminal and conduit boxes need not be removed. (ii) Cover plate of terminal box shall be removed.
M&L for point wiring complete with copper conductor 4 sqmm single core PVC insulated but unsheathed multistranded conductors FRLS, 1100 Volts grade, drawn through existing conduit including 4 sqmm PVC insulated but unsheathed multi stranded copper conductor FRLS cable as earth continuity wire with cover plate fixed on existing terminal boxes,complete all as Specified and directed. Make for cable Polycab/RR/ANCHOR/Havells Note: (i) Existing MS sunken terminal and conduit boxes need not be removed. (ii) Cover plate of terminal box shall be removed.
S&Fswitch piano flush button,240 volts, 6 amps, single pole, one way (ISI marked) complete all as Specified and directed. Make: Havells/Anchor/ legrand
S&Fin replacement of Socket outlet 2 in 1, 3 pin, 5 amp flush type(ISI marked) complete all as Specified and directed. Make: Havells/Anchor/ legrand
Supply and fix in replacement of Socket outlet 3 pin, 16 Amp, flush type complete all as specified and directed. Make: Havells /Anchor/Legrand
Supply and fix in replacement of switch piano flush button 230 V, 16 Amps, Single pole,one way ISI marked complete all as specified and directed. Make: Havells /Anchor/Legrand
M&L for Sub main wiring with two runs of 6 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS 1100 Volts grade cable fire retardant low smoke drawn through and including PVC concealed conduit heavy duty grade ISI marked 25mm dia (external) including conduit accessories like bends, tees, junction boxes etc including 6 sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire fixed complete all as specified and directed. Note: Cost of cutting / chasing on wall and making good after repair shall be deemed to be included in quoted rate . Make of cable: Havells/ Finolex/ RR Kable/ KEI
M&L for Sub main wiring with two runs of 4 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS 1100 Volts grade cable fire retardant low smoke drawn through and including PVC concealed conduit heavy duty grade ISI marked 25mm dia (external) including conduit accessories like bends, tees, junction boxes etc including 4 sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire fixed complete all as specified and directed. Note: Cost of cutting / chasing on wall and making good after repair shall be deemed to be included in quoted rate . Make of cable: Havells/ Finolex/ RR Kable/ KEI
S&F in replacement of casing capping of 25x 16 mm size complete all as specified and as directed Make Pressfit.
S&F in replacement of casing capping of 32x16 mm size complete all as specified and as directed Make Pressfit
S&F in replacement amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning. a) SP 6 To 32 AMP
b) SPN 16 TO 32 AMP
c) SPN 40 to 63 AMP
S&F in replacement of 415V 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed. a) TPN 16 To 32 AMP
b) TPN 40 To 100 AMP
S&F in replacement of 415V 10KA 'C' MOULDED CASE CIRCUIT BREAKER (MCCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning. a) 4 Pole 63Amp
b) 4 Pole 100 Amp
M&L for servicing and testing of Split type air conditioners of 1.5/2 ton capacity of any make inverter / non inverter complete for minimum two times during the contract period of each unit by cleaning cooling coil, condenser fins, blowing off dust from machines & air filters, checking and de-carbonizing , oiling, compressor greasing of blower motor, checking and removing any vibration, remvoing and cleaning the air filter pad testing after fixing at site all as directed.
M&L for detecting the cause of leakage in any type/capacity of 1.5/2 ton inverter / non inverter AC and ensuring the complete system leak proof and charging of refrigerant gas with appropriate quantity including testing for smooth functioning complete all as Specified and as directed by Engr-In Charge Notes :- (i) Dismantling of unserviceable compressor, cost of refrigarent gas and re-installation of serviceable compressor after repairing are deeemed to be included in the quoted rates.
M&L for repairing of PCB suitable for split type AC 1.5 TR type indoor unit complete all as specified and as directed.
M&L for repairing of PCB suitable for split type AC 2 TR type indoor unit complete all as specified and as directed.
Supply only replacement of indoor cooling coil of split type AC 1.5 TR unit complete all as specified and as directed.
S&F in replacement of indoor cooling coil of split type AC 2 TR unit complete all as specified and as directed.
S&F in replacement of Blower motor,single phase,280-380Volt ,50Hz 3 speed for 1.5 Ton indoor unit complete all as Specified and directed.
S&F in replacement of Blower motor,single phase,280-380Volt ,50Hz 3 speed for 2 Ton indoor unit complete all as Specified and directed.
M & L in replacement of remote suitable for 1.5/2 Ton all as Specified and directed.
S&F in replacement of Drain out PVC Pipe of 11/16 inch dia/17.79 mm innerdia for 1.5 Ton/2 ton ac complete all as Specified and directed.
S&F in replacement of swing motor 230Volt for 1.5/2 Ton ac complete all as Specified and directed.
S&F in replacement of compresser of outdoor unit of split type AC 1.5 TR complete all as specified and as directed.
S&F in replacement of compresser of outdoor unit of split type AC 2 TR complete all as specified and as directed.
S&F in replacement of outdoor copper condenser unit of size 20x 30inch size cu tubing size 6 mm dia for outdoor Unit of split type AC 1.5 TR complete all as specified and as directed.
S&F in replacement of outdoor copper condenser unit of size 20x 30inch size cu tubing size 6 mm dia for outdoor Unit of split type AC 2 TR complete all as specified and as directed.
S&F in replacement of fan motor for AC 230Volt 1180 Rpm for outdoor unit split type AC 1.5 TR complete all as specified and as directed.
S&F in replacement of fan motor for AC 230Volt 1180 Rpm for outdoor unit split type AC 2 TR complete all as specified and as directed.
S&F in replacement of running capacitor for motor of capacity 2/4/6 mfd 230 volt suitable for 1.5 Ton ac outdoor unit complete all as specified and as directed.
S&F in replacement of compresser running capacitor of 50 mfd 230 volt suitable for 1.5 Ton ac outdoor unit complete all as specified and as directed.
S&F in replacement of compresser running capacitor of 55 mfd 230 volt suitable for 2Ton ac outdoor unit complete all as specified and as directed.
S&F in replacement of compresser starting capacitor of 45 mfd 230 volt suitable for 1.5 Ton ac outdoor unit complete all as specified and as directed.
S&F in replacement of fan motor blade suitable for motor of 1.5/2 Ton ac outdoor unit complete all as specified and as directed.
S&F in replacement of suction copper tubing of size 5/16'' dia meter with rubberised insulation and tape suitable for supply pipes for air-conditioners complete all specified by Engineer -in-charge.
M&L for replacement of discharge copper tubing of size exsisitng size mm bore including brazing etc and with rubberised insulation and tape suitable for supply pipes for air-conditioners complete all specified .
M&L for with rubberised insulation cover including tape suitable supply pipes for air-conditioners complete all specified.
S&F cable PVC insulated multistranded copper conductor PVC cable of 3 core 3 Sqmm size complete all as specified and directed .
S&Fin replacement of outdoor unit stand of metal inclduing fixing accessories such as nut bolt washers and fastner for 1.5/2 Ton outdoor unit complete all as specified and as directed.
S&Fin replacement of indoor unit bracket of metal inclduing fixing accessories such as nut bolt washers and fastner for 1.5/2 Ton outdoor unit complete all as specified and as directed.
S&Fin replacement of Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as specified and as directed. Make ABB/Havells/Legrand
M&L for repairing of PCB suitable for Inverter type split type AC 1.5 TR type indoor unit complete all as specified and as directed.
M&L for repairing of PCB suitable for Inverter type split type AC 2 TR type indoor unit complete all as specified and as directed.
S&F in replacement of Blower motor,single phase,230V,ac for 1.5 Ton indoor unit of Inverter AC complete all as Specified and directed.
S&F in replacement of Blower motor,single phase,230V,ac for 2 Ton indoor unit of Inverter AC complete all as Specified and directed.
S&F in replacement of indoor condenser copper coil of inverter split type AC 1.5 TR complete all as specified and as directed.
S&F in replacement of indoor condenser copper coil of inverter split type AC 2 TR complete all as specified and as directed.
S&F in replacement of oudoor condenser unit of copper with 2 run of copper pipe of out door unit of inverter split type AC 1.5 TR complete all as specified and as directed.
S&F in replacement of oudoor condenser unit of copper with 2 run of copper pipe of out door unit of inverter split type AC 2 TR complete all as specified and as directed.
S&F in replacement of compresser of outdoor unit of split type AC 1.5 TR inverter type complete all as specified and as directed.
S&F in replacement of compresser of outdoor unit of split type AC 2 TR inverter type complete all as specified and as directed.
S&F in replacement of swing motor 230 Volt for 1.5Ton indoor unit inverter type AC complete all as Specified and directed.
S&F in replacement of swing motor 230 Volt for 2 Ton indoor unit inverter type AC complete all as Specified and directed.
Taking down of split type AC 1.5 Ton Inverter type from site for replacement of outdoor unit and re installing split type AC at site and including refixing of outdoor unit on wall mounted bracket of MS and replacement of refrigerant tubing as per site standard requirement upto 6 RM,any insulated complete all as Specified and as directed. Note- Gas charging if required deemed to be included in unit rate. Make Voltas/Carrier/Hitachi
Taking down of split type AC 2.0 Ton Inverter type from site for replacement of outdoor unit and re installing split type AC at site and including refixing of outdoor unit on wall and outdoor unit an wall mounted including bracket of MS and replacement of refrigerant tubing as per site std requirement upto 6 RM,any insulated complete all as Specified and as directed. Note- Gas charging if required deemed to be included in unit rate. Make Voltas/Carrier/Hitachi
Taking down of split type AC 1.5 Ton Inverter type from site for replacement of indoor unit and re installing split type AC at site and including refixing of indoor unit on wall and outdoor unit an wall mounted including bracket of MS and replacement of refrigerant tubing as per site standard requirement upto 6 RM,any insulated complete all as Specified and as directed Note- Gas charging if required deemed to be included in unit rate. Make Voltas/Carrier/Hitachi
Taking down of split type AC 2 Ton Inverter type from site for replacement of indoor unit and re installing split type AC at site and including refixing of indoor unit on wall and outdoor unit an wall mounted including bracket of MS and replacement of refrigerant tubing as per site std requirement upto 6 RM,any insulated complete all as Specified and as directed Note- Gas charging if required deemed to be included in unit rate. Make Voltas/Carrier/Hitachi
M&L for servicing and maintenance of water cooler,replacement of wornout parts,cleaning of inner tank complete all as specified and as directed
Supply and fix hermetically sealed compressor of water cooler of capacity 40 ltr/hr suitable for R134a gas, single phase alongwith capacitor and relay, including gas charging in the system and testing of water cooler complete all as Specified and as directed by Engr-In Charge. Make : Copeland/Tecumseh. Note : Cost of cutting of existing worn out compressor will be deemed to be included in unit rate.
Taking out burnt unserviceable condenser fan motor,and replacement with new electric motor,single phase 230V of water cooler 40ltrs/hrs with condenser fan blade complete all as Specified and as directed
Supply and fix in replacement of following items of water cooler a) Thermostat for water cooler capacity 40/80 ltr/hrs. Make:Renetor/shriram/Godraj/Danfoss
b) Push type Bib tap Cast copper alloy 15 mm Push type chromium plated.
c) PVC Connection with brass unions at both ends with brass nuts, suitable for fixing to 15 mm dia GI Pipe.
M&L for RO plant servicing including changing of primary filter, secondary Filter complete all as specified and as directed
S&F in replacement of carbon filter of RO plant complete all as speicifed and as directed
S&F in replacement of Booster Pump with inlet and outlet conneciton pipe complete all as specifed and as directed
M&L for charging of refrigerant with exsisitng refrigerent in refrgerator of 165 to 315 Ltr capacity, deepfreezer and water Cooler of 40/80 Ltr and double door refergerator of 984 Ltr capacity with appropriate quantity including testing for smooth functioning complete all as Specified and as directed for
S& F in replacement of overload relay suitable for following capacity refrigerator including necessary capillary complete all as Specified and as directed Make -As per existing a) Refrigerator capacity 300 Ltr
b) Refrigerator capacity 315 Ltr
c) Refrigerator capacity 180 Ltr
S& F in replacement of condensor fan motor suitable for following capacity refrigerator including necessary capillary complete all as Specified and as directed Make -As per existing a) Refrigerator capacity 300 /315 Ltr
b) Refrigerator capacity 180 Ltr
S& F in replacement of compressor Run Capacitor suitable for following capacity refrigerator including necessary capillary complete all as Specified and as directed Make -As per existing a) Refrigerator capacity 300 /315 Ltr
b) Refrigerator capacity 180 Ltr
S& F in replacement of Temp control thermostate suitable for following capacity refrigerator including necessary capillary complete all as Specified and as directed Make -As per existing a) Refrigerator capacity 300/315 Ltr
b)Refrigerator capacity 180 Ltr
Taking down of following items for servicing, cleaning all the dust particles and oiling and greasing the bearing and checking the electrical connection, including painting and refixing of ceiling fan/exhaust fan and wall mounted fan in situ complete all as Specified and directed. Note: (i) Spare parts will be measured and paid separately . (ii) Rewinding/repair of fan motor will be measured and paid separately. a) Ceiling Fan 1200 mm sweep
b) Exhaust Fan 240/300 mm
c) Exhaust Fan 450 mm
d) Wall mounted fan 300 mm
M&L for cutting of burnt winding of rotor and rewinding with same gauge copper wire winding with insulated material and reassembling and other repairing work complete all as Specified and directed. Note:Taking down and refixing charges will be paid under relevant items a) Ceiling Fan 1200 mm sweep
b) Exhaust Fan 240 mm
c) Exhaust Fan 450 mm
d) Wall mounted fan 450 mm
Supply only spare parts of Fan/Exhaust fan of following rating all as Specified and directed a) Capacitor 2.5 MFD
b) Capacitor 3.15 Mfd
c) Ball Bearing No 6201
d) Ball Bearing No 6202
e) Mild steel Down Rod 600 mm Long with Clamp nut bolts & split pin as par sample
f) Mild steel Down Rod with Clamp nut bolts& split pin for 900 mm Long as par sample
g) Ceiling Fan Blade suitable for 1200 mm sweep as per sample.
h) Ceiling fan canopy suitable for 1200 mm sweep
Dismantling electric/water connection and taking down of storage type water heater,servicing,cleaning of inner tank etc.at site.and replacement of burnout parts etc. and refixing in situ all Specified and directed. Note- wornout parts shall be measured as seperately.
S&F in replacement of Heating element 1.5/2 KW Tringular/ circular type with rubber gasket complete all as specified and as directed
S&F in replacement Thermostat as per sample/suitable to 25 Ltrs capacity ISI marked complete all as specified and as directed
S&F in replacement 3 core 1.5/2.5 sqmm PVC insulated cable complete all as specified and as directed
S&F in replacement of LED luminaire, Aluminium extruded housing, 22 W,lumen output not less than 2000 lm, 220-240V, 50Hz, PF>0.9,CCT 6500 K,including electric connecting using cable 2 core 0.5 sqmm cable from ceiling rose to terminal block complete all as specified and directed. Make: BN 021 LED 40S-6500 PSULGR (4 fEET) Smart Brite OF Philips /Wipro/GE
S&F in replacement of LED luminaire, Aluminium extruded housing, 12W,lumen output not less than 1200 lm, 220-240V, 50Hz, ,CCT 6500 K, 2 feet including connecting cable 2 core 0.5 sqmm from ceiling rose to terminal block complete all as specified and directed. Make: BN 021 LED 12S-6500 PSU GR OF Philips (Smart brite / Wipro/GE)
S&F in replacement of Full glow LED fully diffused recessed mounted 2'x2' luminaire with high transimitive diffuser suitable for indoor spaces 240V, 50Hz, CCT 6500 K, ,PF>0.95Square in shape, complete all as specified and as directed. Note- cost of replacing in existing cut out of false ceiling deemed to be included in unit rate Make: Type RC480 B LED 25S/865 W60L60 PSUWH- Philips/ Wipro/GE
S&F in replacement of 33 W Verge high effiicency recess mounted LED recessed mounted luminaire,240V, 50Hz, , CCT 5700K, Square in shape, complete all as specified and as directed. Make: LM 29-451-xxx-57-XX Philips/ GE/ Note- cost of replacing in existing cut out of false ceiling deemed to be included in unit rate
S&F in replacement of 18W Molis LD06 downlight LED mounted luminaire,240V, 50Hz, , CCT 5700 K, round in shape, cutout dimension 168 mm complete all as specified and as directed. Make: LD06 -221-XXX-57-XX ** of Wipro /Philips / GE Note- cost of replacing in existing cut out of false ceiling deemed to be included in unit rate
S&F in replacement of 6.5W Green LED Ultima Square downlight mounted luminaire,240V, 50Hz, 600lm, 4000K Squre in shape, white complete all as specified and as directed by Engr-in-Charge, Note- cost of replacing in existing cut out of false ceiling deemed to be included in unit rate Make: Philips Cat part no DN 096B LED6S-6500 PSU WH /Wipro/ GE
S&F in replacement of false ceiling LED Luminaires round type 220-240 Volt 50 hz 6500 K complete all as specified and as directed. Note- cost of replacing in existing cut out of false ceiling deemed to be included in unit rate Make:Wipro Model No RSP 10 Amp /Philips/GE
M&L for annual maintenance of 20 KW solar power plant including inspection of all serviceable parts panel inverter communication instrument with erection, testing and commissioning, cleaning of panel maintaining GPRS network SIM etc. complete all as specified and directed. Note; Cost include following: 1. Quarterly checking and servicing of all serviceable parts excluding ACDB. 2. Cleaning of Solar panel as directed byEngineer-in-charge. 3. Minor repair of spare parts of necessary included in quoted rate.
M&L for servicing of ACDB complete including servicing of all electronic parts like MCB NVR relay etc. Note: Cost of replacement of damaged spare parts if necessary to make the system serviceable is deemed to be included in the quoted rate.
SURESH ELECTRICALS
JAMNAGAR ELECTRIC AND MACHINERY CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .