Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.4 LAccepted-AOC BUMHAMA KUPWARA KHAN MOHALLA BUMHAMA KUPWARA KUPWARA KUPWARA JAMMU KASHMIR 193222 | KUPWARA | JAMMU AND KASHMIR | 193222 | L1 | Accepted-AOC Due to L1 | |
| 2 | L2₹12.1 L+₹1.7 L (15.9%)Rejected-Finance | L2 | Rejected-Finance Due to L2 | |
| 3 | L3₹12.1 L+₹1.7 L (16.1%)Rejected-Finance | L3 | Rejected-Finance Due to L3 |
| Sl No | Description | Qty | Unit | VIKAS ENTERPRISES L3 | A. R. Electric Corporation, Roorkee L2 | M/s Malik and Company L1 |
|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully old electric point wiring, sub main , switch board, Power point all electric fitting & fixture etc from Type III Quarter and shifting of old materials with CBRI (Central Store )as required and directed by engineer-incharge. | 10 | Quarter | 10,000 ₹1,00,000 | 1,000 ₹10,000 | 200 ₹2,000 Lowest |
| 2.00 | Wiring for light Point /fan point /exhaust fan /call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed steel conduit with modular switch of ISI marked, modular plate suitable G.I Box and earthing the point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable including ceiling rose etc as required. Group A | 300 | Point | 950 ₹2,85,000 Lowest | 1,000 ₹3,00,000 | 950 ₹2,85,000 Lowest |
| 3.00 | Wiring for twin control light point with 1.5sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2way modular switc, modular plate , suitable GI Box abd earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. | 10 | Point | 800 ₹8,000 Lowest | 2,120 ₹21,200 | 1,100 ₹11,000 |
| 4.00Wiring for circuit /sub-main wiring along with earthwire with the following size of FRLS PVC Insulated copper conductor single core cable of ISI Marked in surface/ recessed steel conduit as required | ||||||
| 4.01 | 2 x 2.5 sqmm + 1 x 2.5 sqmm earth wire | 600 | Meter | 280 ₹1,68,000 Lowest | 365 ₹2,19,000 | 290 ₹1,74,000 |
| 4.02 | 2 x 4 sq mm + 1 x 4 sq mm earth wire | 700 | Meter | 300 ₹2,10,000 Lowest | 435 ₹3,04,500 | 360 ₹2,52,000 |
| 4.03 | 2 x 10 sq mm + 1 x 10 sq mm earth wire | 20 | Meter | 500 ₹10,000 Lowest | 762 ₹15,240 | 750 ₹15,000 |
| 5.00 | Supplying & Fixing of modular blanking plate on the existing modular plate & switch box excluding modular plate. As required | 50 | Each | 25 ₹1,250 | 15 ₹750 Lowest | 25 ₹1,250 |
| 6.00 | Supplying & Fixing Suitable size GI box with modular plate and cover in front on surface or in recess , including providing & Fixing 3pin 5/6 A modular socket outlet and 5/6 AmModular switch of ISI marked , connections etc as required. | 80 | Each | 650 ₹52,000 | 510 ₹40,800 | 350 ₹28,000 Lowest |
| 7.00 | Supplying & Fixing Suitable size GI box with modular plate and cover in front on surface or in recess , including providing & Fixing 6pin 5/6 and 15/16 A modular socket outlet and 15/16A modular switch of ISI marked , connections etc as required. | 100 | Each | 850 ₹85,000 | 627 ₹62,700 | 440 ₹44,000 Lowest |
Tender Value
Refer Docs
EMD Value
₹27,000
Closing Date
7 Aug 2025, 10:00 amClosed
Director CSIR-CBRI Roorkee
Director CSIR-CBRI Roorkee
Electrical Work
2025_CSIR_242294_1
72(Vid)/TSG/QTR/Col./25-26
Open Tender
Electrical Works
Works
30 days
Director CSIR-CBRI Roorkee
10 documents required · 10 mandatory
₹590
Director CSIR-CBRI
₹27,000
16 Sept 2025
23 Jul 2025
8 Aug 2025
23 Jul 2025
7 Aug 2025
23 Jul 2025
Amount
Taking down carefully old electric point wiring, sub main , switch board, Power point all electric fitting & fixture etc from Type III Quarter and shifting of old materials with CBRI (Central Store )as required and directed by engineer-incharge.
Wiring for light Point /fan point /exhaust fan /call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed steel conduit with modular switch of ISI marked, modular plate suitable G.I Box and earthing the point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable including ceiling rose etc as required. Group A
Wiring for twin control light point with 1.5sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2way modular switc, modular plate , suitable GI Box abd earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for circuit /sub-main wiring along with earthwire with the following size of FRLS PVC Insulated copper conductor single core cable of ISI Marked in surface/ recessed steel conduit as required
2 x 2.5 sqmm + 1 x 2.5 sqmm earth wire
2 x 4 sq mm + 1 x 4 sq mm earth wire
2 x 10 sq mm + 1 x 10 sq mm earth wire
Supplying & Fixing of modular blanking plate on the existing modular plate & switch box excluding modular plate. As required
Supplying & Fixing Suitable size GI box with modular plate and cover in front on surface or in recess , including providing & Fixing 3pin 5/6 A modular socket outlet and 5/6 AmModular switch of ISI marked , connections etc as required.
Supplying & Fixing Suitable size GI box with modular plate and cover in front on surface or in recess , including providing & Fixing 6pin 5/6 and 15/16 A modular socket outlet and 15/16A modular switch of ISI marked , connections etc as required.
Supplying & Fixing PVC batten / angle holder including connection etc. as required.
Supplying and fixing call bell suitable for single phase, 230V, complete as required.
Supplying and fixing 5A to 32A rating, 240V/415V , 10kA,"C" curve , miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
32A SP MCB
Triple Pole
S/F following rating, double pole, 240V isolator in the existing MCB DB complete with connections testing and commissioning etc. as required.
Supplying and fixing of following ways surface/ recess mounting , Vertial type, 415V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted , inclusive of 200A , tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Verticle type MCB TPDB is normally used where 3 phase outlets are required. )
8 way ( 4+ 24 ), double door
providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connectins, etc. as required.
125A, 36KA , FPMCCB
Supplying and fixing 2 + 8 way, single pole and neutral, sheet steel, MCB distribution board 240V make on surface/ recess, complete with tinned copper bus bar,Neutral bus bar, Earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB/ RCCB/ Isolator)
Excavation for cable trenches in soft soil. Depth upto 1.2m including dressing of sides lift upto 1.5m, including getting out the excavated soil, refilling with sand and or good soil after laying of cable/pipe etc in layers of 20cm , ramming , watering and disposal of surplus excavated soil as directed, with a lead of 50 meters.
Supply, Installation, Testing and commissioning of 1200mm sweep, BEE 5star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation : B,3 nos. blades, 30cm long down rod, 2 nos. canopies, shackle kit, safety rope, coppper winding, power factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM ( tolerance as per IS : 374-2019), THD less than 10% remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise= 75 degree C( max ). insulation resistance more than 2 mega ohm, suitable for230V, 50Hz single phase AC Supply, earthing etc. complete as required.
Supplying & Laying of 35sq. mm 4 core Al armoured cable of as required and directed by engineer-incharge.
Supplying and fixing of the AC Single phase with display rating 10-60A latest multifunction digital energy meter as required and directed by engineer-incharge
Supplying and fixing of 10 W LED Bulkhead Minimum IP rating 65 as required and directed by engineer-incharge.
A. R. Electric Corporation, Roorkee (BID ID -879892)
VIKAS ENTERPRISES (BID ID -879724)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .