Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-AOC B 39 UPPER GROUND FATEH NAGAR NEW DELHI 110018 | WEST | DELHI | 110018 | ₹1.3 Cr Quoted ₹1.4 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.5 Cr+₹10.0 L (7.09%)Rejected-AOC | ₹1.5 Cr+₹10.0 L (7.09%) | L2 | Rejected-AOC L2 |
| Sl No | Description | Qty | Unit | ABHISHEK ENTERPRISES L1 | M/S MECHANICAL ENGINEERING and ELECTRICAL CONTRACTORS L2 |
|---|---|---|---|---|---|
| 1.00 | Dismantling of unserviceable/serviceable ACSR Conductor of any size from existing LT over head lines complete all as specified and directed. | 72.2 | Per Qtl | 100 ₹7,220 Lowest | 279 ₹20,143.8 |
| 2.00 | Dismantling of GI wire from existing LT over head line complete all as specified and directed. | 15.2 | Per Qtl | 100 ₹1,520 | 88.19 ₹1,340.49 Lowest |
| 3.00 | Dismantling of cross arms of MS fabricated complete with all accessories viz nut, bolts, washer etc. complete all as specified and directed. | 7.3 | Per Qtl | 100 ₹730 Lowest | 189 ₹1,379.7 |
| 4.00 | Taking down carefully old unserviceable/serviceable insulator any type from existing LT over head lines complete all as specified and directed. | 190 | Each | 500 ₹95,000 | 2.69 ₹511.1 Lowest |
| 5.00 | Taking down carefully security light fitting of any make/capacity from existing LT poles complete all as specified and directed. | 40 | Each Job | 100 ₹4,000 Lowest | 111 ₹4,440 |
| 6.00 | Dismantling of stay assembly along with all accessories from existing LT poles complete all as specified and directed. | 6 | Per Set | 50 ₹300 Lowest | 59 ₹354 |
| 7.00 | Dismantling of existing LT PCC/RCC Poles complete all as specified and directed. | 20 | Each | 1,500 ₹30,000 | 1,119 ₹22,380 Lowest |
| 8.00 | Excavation in trenches not exc 1.5 mtr width and not exc 1.5 mtr in depth and getting out in hard/dense soil for laying of UG cable complete all as specified and directed. | 3,186 | Cum | 500 ₹15,93,000 | 346 ₹11,02,356 Lowest |
| 9.00 | Excavating in trenches, not exceeding 1.5 mtr wide and exceeding 1.5 mtr deep and not exceeding 3 mtr deep for excavation of poles and getting out in any type of soil complete all as specified and directed. | 0.72 | Cum | 1,200 ₹864 | 369 ₹265.68 Lowest |
| 10.00 | Returning , filling in incl spreading, leveling , watering and well ramming in layers not exc 25 cm thick in soil complete all as specified and directed. | 1,915.38 | Cum | 80 ₹1,53,230.4 Lowest | 89 ₹1,70,468.82 |
Tender Value
₹1.4 Cr
EMD Value
₹2.2 L
Closing Date
18 Aug 2025, 6:00 pmClosed
CWE LIKABALI
HQ CWE Likabali Military Engineer Services Pin 901266 C/o 99 APO
SPECIAL REPAIR TO CONVERSION OF LT OH ELECTRIC LINE INTO UG CABLE AND LT PCC/RCC POLE INTO STEEL TUBULAR POLE ALONGWITH CONNECTED MISC WORKS AT BORARUPAK MIL STN UNDER GE 872 EWS
2025_MES_721756_1
83013/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Borarupak
Please per NIT
6 documents required · 6 mandatory
₹1,000
GE LIKABALI
₹2.2 L
Yes
10 Oct 2025
21 Jul 2025
26 Aug 2025
21 Jul 2025
18 Aug 2025
11 Aug 2025
Amount
Dismantling of unserviceable/serviceable ACSR Conductor of any size from existing LT over head lines complete all as specified and directed.
Dismantling of GI wire from existing LT over head line complete all as specified and directed.
Dismantling of cross arms of MS fabricated complete with all accessories viz nut, bolts, washer etc. complete all as specified and directed.
Taking down carefully old unserviceable/serviceable insulator any type from existing LT over head lines complete all as specified and directed.
Taking down carefully security light fitting of any make/capacity from existing LT poles complete all as specified and directed.
Dismantling of stay assembly along with all accessories from existing LT poles complete all as specified and directed.
Dismantling of existing LT PCC/RCC Poles complete all as specified and directed.
Excavation in trenches not exc 1.5 mtr width and not exc 1.5 mtr in depth and getting out in hard/dense soil for laying of UG cable complete all as specified and directed.
Excavating in trenches, not exceeding 1.5 mtr wide and exceeding 1.5 mtr deep and not exceeding 3 mtr deep for excavation of poles and getting out in any type of soil complete all as specified and directed.
Returning , filling in incl spreading, leveling , watering and well ramming in layers not exc 25 cm thick in soil complete all as specified and directed.
Removal of surplus soil to a distance not exc 50 mtr away and depositing where directed as a level not exc 1.5 mtr above the starting point.complete all as specified and directed.
M&L for sand cushioning using dry and clean tibba sand in two layers, first layers of 80 mm thick before laying of cable and second layer of 150 mm thick after laying of cable in trenches/ducts including consolidation of each layers complete all as specified and directed. Note :- Punned thickness only will be measured and paid.
Supply and laying well burnt/fire Bricks of size 230 x113 x 75 mm locally available best quality (sub class "B" bricks) laid in trenches perpandicular to U/G cable for cable protection complete all as specified and directed.
Supplying, errecting and fixing steel tubular swaged poles with cast iron base plate of size 300mm x 300mm x 6mm, finial taper plug, bolts, nuts & screws for type 410 SP-31 (9 metres long) including painting with two coats of aluminium paint over one coat of redoxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2" (inch) wide complete all as specified and directed. (Note :- Excavation, earth work, PCC in foundation and coping shall be measured and paid separately under relevant item of this schedule)
Material and labour for PCC 1:4:8 type D2 using 40mm stone aggregate as in foundation and mass concrete all as specified and directed.
Material and labour for PCC 1:3:6 type C2 using 40mm stone aggregate as in foundation mass concrete all as specified and directed.
Material and labour for PCC 1:2:4 type B1 using 20mm stone aggregate in coping to pole including form work all as specified and directed.
Supply and lay XLPE Insulated, screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 Volts grade of size 95 Sqmm x 3.5 Core complete all as specified and directed.
All as per item No.18.00 here- in- before but of size 70 Sqmm x 3.5 Core.
All as per item No.18.00 here- in- before but of size 50 Sqmm x 3.5 Core.
All as per item No.18.00 here- in- before but of size 35 Sqmm x 3.5 Core.
All as per item No.18.00 here- in- before but of size 25 Sqmm x 4 Core.
All as per item No.18.00 here- in- before but of size 16 Sqmm x 4 Core.
All as per item No.18.00 here- in- before but of size 16 Sqmm x 2 Core.
All as per item No.18.00 here- in- before but of size 10 Sqmm x 2 Core.
Supply and laying of GI tubing light grade in protection of cable at road crossing /hard standing/pole protection fixed with clamps as per site requirement etc all as specified and directed of size 80 mm dia bore.
All as per item No.26.00 here- in- before but of size 50 mm dia bore.
Cutting the existing road straight by manual upto 100 mm dia dore, depth and width not less than 1 Mtr below ground level for passing of underground cable and filling back with excavated soil up to 75 % road portion and 25 % shall be made with cement concrete 1:2:4 (using 20 mm graded aggregate stone complete all as specified and directed.
All as per item No.28.00 here- in- before but size 50 mm dia bore.
S&F Cable Route indicator duly marked with "LT UG cable" CI plate elliptical shape with 12mm dia MS rod not less than 700mm in length and embeded in PCC block 1:3:6 of size 300x300x300mm in gound including necessary earth work complete all as specified and directed.
Supply, lay, commissioning and testing of cable jointing Kit for 1100 V grade cable for straight through joint with jointing material and accessories suitable for aluminium conductor cable of size upto 50 Sqmm x 3.5 Core complete all as specified and directed.
All as per item No 31.00 here- in- before but of size from 70 Sqmm to 120 Sqmm x 3.5 Core.
S&F pole mounted shockproof and rustproof Junction Box rectangular shape, 4 way of size 240X130X110 mm indoor/outdoor type and fixing with one MCB SP 10 Amps, 'C' curve, 10 kA including fixing with two nos flat iron clamps of suitable size with necessary mild steel nuts & bolts complete all as specified and as directed.
Fixing only of serviceable LED street light fitting of any make/capacity complete all as specified and directed.
Supply and fixing LED street light fitting of capacity 60 Watt, 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal anagement in multiple optics complete with IP 65/66 protection complete all as specified and directed.
All as per item No 35.00 here- in- before but of size of capacity 45 Watt, 230 V AC outdoor type complete all as specified and directed.
M&L Street light bracket made out of 150 cm long 25/32/40 mm dia light grade GI pipe with provision of nut and bolts for fixing on top of the pole duly painted with two coats of silver paint over a coat of red oxide primer complete all as specified.
S&F (FR) PVC insulated and PVC round unsheathed multistranded copper conductor flexible cable of size 1.5 sqmm x 3 core, complete all as specified and directed.
S&F LED flood light of capacity 120 watt, 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed.
Supply and fix in replcement of Street light Digital timer comprising of incoming cable termincal, MCBs, timer, contactor, outgoing termincal duly prewired and accessories housed in MS box outdoor type of capacity 40 Amps TPN, 3 pole, 230 volts contractor rating 32 Amps TP complete all as specified and directed including installation and testing .
Supply and installation CPRI approved LT Electric control panel, cubical type, for outdoor use, double door dust & vermin proof floor mounted made out of CRCA steel sheet of 3.15 mm thick and 2.00 mm thick other parts and angle iron legs of size 50mmx50mmx6mm having front and rear hinged doors with front openable shutters for each MCCB/Change Over with spreader & extended rotary handle having hinges on one side and locating arrangements with screws type on other sides completely with fully enclosed bus bar chamber, having electrolytic high conductivity insulated bas bar made but of aluminium strips of rating 600 amps for 3 phase, 415 volts, 50 C/S 4 wire system, with cable entry provision, with suitable lugs gland, voltmeter , Ammeter and phase indicator complete, duly painted with two coats of stove enameled powder coated paint over as coat of red oxide primer complete all as including necessary PCC work of height 45 cm from the ground level all as specified and directed. INCOMMING : (i) MCCB 4 Pole, 415 V, Adjustable type, 125 Amps with breaking capacity 16 kA - 01 No (ii) Basic Multifunction Meter Cl 0.5 with RS485 - 01 No. (iii) LED Indicator lamp in three colour RYB - 01 Set of 3. OUTGOING : (i) MCCB 4 Pole, 415 V, Adjustable type, 63 Amps with breaking capacity 16 kA - 02 No's (ii) MCB TPN of capactiy 63 Amps, 415 V, 10KA 'C' curve - 03 No's (iii) MCB SPN of capactiy 40 Amps, 240 V, 10KA 'C' curve - 04 No's
Supply and installation CPRI approved LT Electric control panel, cubical type, for outdoor use, double door dust & vermin proof floor mounted made out of CRCA steel sheet of 3.15 mm thick and 2.00 mm thick other parts and angle iron legs of size 50mmx50mmx6mm having front and rear hinged doors with front openable shutters for each MCCB/Change Over with spreader & extended rotary handle having hinges on one side and locating arrangements with screws type on other sides completely with fully enclosed bus bar chamber, having electrolytic high conductivity insulated bas bar made but of aluminium strips of rating 600 amps for 3 phase, 415 volts, 50 C/S 4 wire system, with cable entry provision, with suitable lugs gland, voltmeter , Ammeter and phase indicator complete, duly painted with two coats of stove enameled powder coated paint over as coat of red oxide primer complete all as including necessary PCC work of height 45 cm from the ground level all as specified and directed. INCOMMING : (i) MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 16 kA - 01 No (ii) Basic Multifunction Meter Cl 0.5 with RS485 - 01 No. (iii) LED Indicator lamp in three colour RYB - 01 Set of 3. OUTGOING : (i) MCCB 4 Pole, 415 V, Adjustable type, 100 Amps with breaking capacity 16 kA - 01 No (ii) MCCB 4 Pole, 415 V, Adjustable type, 63 Amps with breaking capacity 16 kA - 02 No's (iii) MCB TPN of capactiy 63 Amps, 415 V, 10KA 'C' curve - 04 No's
Supply and installation CPRI approved LT Electric control panel, cubical type, for outdoor use, double door dust & vermin proof floor mounted made out of CRCA steel sheet of 3.15 mm thick and 2.00 mm thick other parts and angle iron legs of size 50mmx50mmx6mm having front and rear hinged doors with front openable shutters for each MCCB/Change Over with spreader & extended rotary handle having hinges on one side and locating arrangements with screws type on other sides completely with fully enclosed bus bar chamber, having electrolytic high conductivity insulated bas bar made but of aluminium strips of rating 800 amps for 3 phase, 415 volts, 50 C/S 4 wire system, with cable entry provision, with suitable lugs gland, voltmeter , Ammeter and phase indicator complete, duly painted with two coats of stove enameled powder coated paint over as coat of red oxide primer complete all as including necessary PCC work of height 45 cm from the ground level all as specified and directed. INCOMMING : (i) MCCB 4 Pole, 415 V, Adjustable type, 200 Amps with breaking capacity 16 kA - 01 No (ii) Basic Multifunction Meter Cl 0.5 with RS485 - 01 No. (iii) LED Indicator lamp in three colour RYB - 01 Set of 3. OUTGOING : (i) MCCB 4 Pole, 415 V, Adjustable type, 125 Amps with breaking capacity 16 kA - 01 No (ii) MCCB 4 Pole, 415 V, Adjustable type, 100 Amps with breaking capacity 16 kA - 02 No's (iii) MCCB 4 Pole, 415 V, Adjustable type, 63 Amps with breaking capacity 16 kA - 03 No's
M & L for Earthing complete with galvanised mild steel earth plate electrode 600X600X6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr deep below normal ground level, connected to machinery/equipment etc and incl GI strip 32×6 mm dia as earthing lead by means of bolts, nuts, check nuts and washers, protected with and incl 50 mm dia light grade GI pipe, 20 mm dia GI pipe (Medium grade) for watering, necessary earth work. PCC 1:3:6 type C1 concrete pit, RCC (1:1.5:3) type A1 pre-cast cover (54X54X5 cm) duly reinforced with and incl 8 mm dia TMT bar @ 150 mm c/c both ways, one lifting handle made of 8 mm dia TMT bar, embedded in pre-cast cover slab all as specified and shown in electrical plate No-3 of SSR Part-I including testing on completion complete all as specified and directed.
M/S MECHANICAL ENGINEERING and ELECTRICAL CONTRACTORS (BID ID -3398159)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .