Loading…
Loading…
Tender Value
₹1.6 Cr
EMD Value
₹3.1 L
Closing Date
27 Jul 2026, 3:00 pm
Provision of Lift at HCR, OMLF, AZR, BNDP, GRMP, PRNA, RGJ and KIR Stations in Connections with Development of FOBs along with Other Anciliary Works under Katihar Division
44_2026
44_2026
Open
12 Months
Katihar, Bihar
₹0
₹3.1 L
4 Jul 2026
4 Jul 2026
13 Jul 2026
Item- 1 Please see in item Breakup
S No. Item Description of Item Unit Qty Rate Amount
KATIHAR DIVISION-ELECTRICAL/N F RLY
1 1 Supply, wiring, testing & commissioning of Numbers 220.00 797.00 175340.00
concealed point wiring by FR PVC insulated and
unsheathed 1.5 sq mm, single core multi strand
copper wire with earth continuity wire by PVC
insulated and unsheathed 1 sq mm , single core
multi strand copper wire concealed on wall
through PVC rigid conduit pipe of dia not less
than 20 mm dia heavy duty including all types of
joints and bends as required, complete with 6
amps flush type controlling modular switch to be
mounted on modular GI inner plate and modular
mounting frame of suitable module as per
requirement complete to be concealed in wall as
per instruction of Engineer Incharge at site.
Existing wall should be cut and re-mended to
original finish by contractor's own material. a) FL
Point/LED Tube Point/LED Recess Light Point with
2 2 b) Lamp Point with angle holder Numbers 32.00 704.00 22528.00
3 3 Supply, wiring, testing & commissioning of Numbers 100.00 737.00 73700.00
concealed plug point on separate board complete
with 2 x 6 Amp modular socket and 6/10 amps
modular switch to be mounted on modular GI
inner plate 6M and 6M modular mounting frame
with GI box to be concealed in wall as per
instruction of Engineer Incharge at site. Existing
wall should be cut and re-mended to original
finish by contractor's own material.
4 4 Supply, wiring, testing & commissioning of Numbers 60.00 855.00 51300.00
concealed 6/16 amps power plug point on
separate board complete with modular 16 amps
switch (with indicator) and 6/16 amps 3 pin
combined shuttered socket to be mounted on
modular GI inner plate 4M or suitable size with
modular mounting frame to be concealed in wall
as per instruction of Engineer Incharge at Site.
5 5 Supply, fixing, connection & testing of 40 Watt Numbers 100.00 1890.00 189000.00
LED Tubelight, Surface/ Pendent mounting LED
Battens in Extruded aluminium housing as per
instruction of Engineer Incharge at Site.
6 6 Supply, installation, testing & commissioning of Numbers 120.00 1614.00 193680.00
15 Watt Recess mounted downlighter with
pressure die-cast aluminium heat sink & PC
diffuser with integrated driver as per instruction
of Engineer Incharge at Site. (Round Type)
7 7 Supply, fixing & testing and commissioning of Numbers 32.00 670.00 21440.00
LED 12 W B22 CDL INVERTER BULB V2 as per
instruction of Engineer Incharge at Site.
8 8 Supply, wiring & testing of main wire by 2.5 sq Metre 4000.00 75.00 300000.00
mm, Single Core FR-LSH PVC Insulated Industrial
Grade Copper Conductor (Unsheathed) Flexible
Cables, 1100 Volts and earth continuity wire by
1.0 sq mm FR-LSH PVC Insulated Industrial Grade
Copper Conductor Conforming to IS: 694
concealed in wall through PVC rigid conduit pipe
not less than 20 mm dia as per instruction of
Engineer incharge at site.
9 9 Supply, wiring & testing of main wire by 4 sq mm, Metre 3000.00 87.00 261000.00
Single Core FR-LSH PVC Insulated Industrial Grade
Copper Conductor (Unsheathed) Flexible Cables,
1100 Volts and earth continuity wire by 1.0 sq
mm FR-LSH PVC Insulated Industrial Grade
Copper Conductor Conforming to IS: 694
concealed in wall through PVC rigid conduit pipe
not less than 20 mm dia as per instruction of
Engineer incharge at site.
KATIHAR DIVISION-ELECTRICAL/N F RLY
10 10 Supply, wiring & testing of main wire by 6 sq mm, Metre 2000.00 100.00 200000.00
Single Core FR-LSH PVC Insulated Industrial Grade
Copper Conductor (Unsheathed) Flexible Cables,
1100 Volts and earth continuity wire by 1.0 sq
mm FR-LSH PVC Insulated Industrial Grade
Copper Conductor Conforming to IS: 694 through
PVC rigid conduit pipe/polythene pipe not less
than 20 mm dia as per instruction of Engineer
incharge at site.
11 11 Supply, installation, testing & commissioning of Numbers 160.00 1265.00 202400.00
10 watt LED Bulkhead luminaires, IP65 as per
instruction of Engineer incharge at site.
12 12 Supply, installation, testing & commissioning of Numbers 25.00 18420.00 460500.00
200 watt LED flood light luminaires complete with
pressure die cast aluminium housing, IP 66,
Luminous efficacy 120 lm/watt with heat sink
feature, surge protection etc including wire
connection as per instruction of Engineer
incharge at site.
13 13 Supply, installation, testing & commissioning of Metre 150.00 1561.00 234150.00
Hot Dipped Galvanized Wire Mesh Cable Tray of
size (Depth- 54 x Width- 150) mm, made of
carbon steel (ASTM A510, Grade-1008 specified)
finished by electrozinc plating (ASTM B 633
specified) alongwith all accessories like suitable
type of splices, locking tab, divider coupler,
preclick, SWK, clamp, Tee, bend, bracket, nut,
bolts etc. Trays should comply standard EN ISO
1461: atleast 550 h of SST. Assemblies with
specific fire resistant properties must have an
E30-E90 certificate. Rod-dia must be from 3.9
mm to 5.9 mm or higher and as per site site
requirement and as per instruction of engineer
incharge at site.
14 14 Design, manufacture, display of wall /hanging / Square 300.00 2868.00 860400.00
floor mounting type LED illuminated sign / Foot
direction boards in half elliptical shape. The
display sheet shall be of unbreakable 040
translucent polycarbonate sheet of 2 mm
thickness. The text / graphics matter visibility
shall not be less than 160 deg. The approved
colour text and graphics shall be printed / router
cut on monomeric calendered vinyl of 70 mm
thickness and shall be firmly pasted on display
sheets. The mounting arrangement shall be
hanging, wall mounting, ceiling mounting, pole
mounting or floor mounting and as per site
requirement. The signage shall have the integral
mounting arrangements with sturdy structural
frame and ACP cladding on the back side of the
signage to avoid rusting and entry of dust. The
LED board shall have uniform illumination with 4-
8 W / sq. ft and with brightness more than
ambient light. Suitable size end cap of 1.5 mm
thick SS 304 should be provided. (Signage Board
should as per Railway Board Letter No. 2023/SD-
KATIHAR DIVISION-ELECTRICAL/N F RLY
15 15 Erection and installation of wall / hanging / floor Square 300.00 287.00 86100.00
mounting type LED illuminated sign / direction Foot
boards in half elliptical shape. The display sheet
shall be of unbreakable 040 translucent
polycarbonate sheet of 2 mm thickness. The
text/graphics matter visibility shall not be less
than 160 deg. The approved colour text and
graphics shall be printed / router cut on
monomeric calendered vinyl of 70 mm thickness
and shall be firmly pasted on display sheets. The
mounting arrangement shall be hanging, wall
mounting, ceiling mounting, pole mounting or
floor mounting and as per site requirement. The
signage shall have the integral mounting
arrangements with sturdy structural frame and
ACP cladding on the back side of the signage to
avoid rusting and entry of dust. The LED board
shall have uniform illumination with 4-8 W / sq. ft
and with brightness more than ambient light.
Suitable size end cap of 1.5 mm thick SS 304
should be provided. (Signage Board should as per
Railway Board Letter No. 2023/SD-II/22/07/02
16 16 Supply, laying, commissioning & testing of GI pipe Metre 1600.00 850.00 1360000.00
100 mm medium guage with suitable fixing
arrangement by MS clamp of size 50x6 mm and
suitable size nut, bolt etc. (For protection of
cable) as per instruction of Engineer incharge at
17 17 Supply, laying, commissioning & testing of HDPE Metre 1600.00 70.00 112000.00
pipe 50 mm dia, PN-6 grade to be laid partly
along the p o l e / w a l l with suitable fixing
arrangement by MS clamp made of MS flat of size
50x6 mm and suitable size nut , bolt, washer etc
as per instruction of Engineer Incharge at site.
18 18 Supply & Erection of earth by 50 mm dia 3 Mtrs. Numbers 32.00 4349.00 139168.00
long (3.6 mm thickness) GI pipe, 32x6 mm GI
strip- 5 Mtrs, GI nuts, bolts including masonry
materials for earthing pit, salt, charcoal, soldered
end terminal etc. and construction of earth pit
covered with RCC cover slab12.7 mm thickness
and watering pipe as per Drg. No.-
PCEE/ELG/DRG/2024/1 Date:- 30.09.2024 and as
per instruction of Engineer Incharge at site.
19 19 Supply, fixing, testing & commissioning of 20 Set 48.00 2724.00 130752.00
amp Industrial plug & socket DB (CRCA/SS made)
complete with metal Plug, socket (3P) & MCB DP
20 amp. as per instruction of Engineer Incharge
20 20 Supply, fixing, testing & commissioning of 63 Set 16.00 9912.00 158592.00
amp Industrial plug & socket DB (CRCA/SS made)
complete with metal Plug, socket (3P/5P) & MCB
DP 63 amp. as per instruction of Engineer
Incharge at Site.
21 21 a) Supply, installation, testing & commissioning of Set 16.00 2005.00 32080.00
12 way SPN Distribution Board, Flush/Surface
mounting, IP 43 grade protection with copper bus
bar, fully shrouded neutral bar, earth bar, cable
ties, metal double door as per IS 8623 - III with
supply and fixing of following RCBO/MCB's as per
instruction of Engineer Incharge at Site.
conforms to IS/IEC 60898:2002
Conforms to IS/IEC 60898 - 1:2002
Conforms to IS/IEC 60898 - 1:2002
KATIHAR DIVISION-ELECTRICAL/N F RLY
25 25 a) Supply, fabrication, erection, testing, Set 8.00 32916.00 263328.00
commissioning & painting of floor mounted
powder coated cubicle panel board (Modular look)
of suitable size (neither big nor small) ), outdoor
type with double door made of suitable size MS/GI
angle 50 x 50 x 6 mm, MS/GI flat 50 x 6 mm, 14
SWG MS sheet/Powder coated CRCA sheet with
provision of weather proof,rust proof,dust
proof,water proof having internal rubber gasket
with supply and fixing of following ACB/MCCB/Bus
bar/Meter etc. (Connections to be made by
copper strips, glands should be provided at cable
entry and exit, components should be
compartmentalized, Each compartment will be
provided with the door and pad locking
arrangement. The compartment illumination lamp
with door operated switch shall be provided for
each compartment. Panel board drawing
approval must be obtained with clear indication
of make of items of components):-
28 28 d) Copper bus bar 100 amps made of electrolytic Set 8.00 900.00 7200.00
grade copper consisting of 4 bars ( 3 Ph and
Neutral ) ( Bus bar should have insulation cover)
ammeter (0-500) amps with s/switch and CTs
31 31 Laying, commissioning & testing of HT/LT Metre 4000.00 55.00 220000.00
XLPE/PVC cable of different sizes partly along the
pole and partly through ground in cable trench by
excavation of ground below 1.5 mt from ground
level with suitable fixing arrangement by MS
clamp of size 50x6 mm and suitable size nut,
bolt. Loading, Unloading & Carrying of cable to
actual work site by contractor's own
arrangement. (Aluminium Crimping Socket should
be provided for each Cable Termination). (Cable
will be supplied by Railway)
32 32 Cutting of Road/Pucca/Hard Soil below (0.3 x 1) Metre 3200.00 298.00 953600.00
mt from ground level and make it good as original
with supply & execution of CC work (1:3:6) as per
instruction of Engineer incharge at site.
Schedule Schedule 2-PART-B (Under Jurisdiction of SSE/Elect./P/IC/BOE) (Station - AZR & RGJ)
Item- 1 Please see the item breakup
S No. Item Description of Item Unit Qty Rate Amount
1 1 Supply, wiring, testing & commissioning of Numbers 110.00 797.00 87670.00
concealed point wiring by FR PVC insulated and
unsheathed 1.5 sq mm, single core multi strand
copper wire with earth continuity wire by PVC
insulated and unsheathed 1 sq mm , single core
multi strand copper wire concealed on wall
through PVC rigid conduit pipe of dia not less
than 20 mm dia heavy duty including all types of
joints and bends as required, complete with 6
amps flush type controlling modular switch to be
mounted on modular GI inner plate and modular
mounting frame of suitable module as per
requirement complete to be concealed in wall as
per instruction of Engineer Incharge at site.
Existing wall should be cut and re-mended to
original finish by contractor's own material. a) FL
Point/LED Tube Point/LED Recess Light Point with
KATIHAR DIVISION-ELECTRICAL/N F RLY
3 3 Supply, wiring, testing & commissioning of Numbers 50.00 737.00 36850.00
concealed plug point on separate board complete
with 2 x 6 Amp modular socket and 6/10 amps
modular switch to be mounted on modular GI
inner plate 6M and 6M modular mounting frame
with GI box to be concealed in wall as per
instruction of Engineer Incharge at site. Existing
wall should be cut and re-mended to original
finish by contractor's own material.
4 4 Supply, wiring, testing & commissioning of Numbers 30.00 855.00 25650.00
concealed 6/16 amps power plug point on
separate board complete with modular 16 amps
switch (with indicator) and 6/16 amps 3 pin
combined shuttered socket to be mounted on
modular GI inner plate 4M or suitable size with
modular mounting frame to be concealed in wall
as per instruction of Engineer Incharge at Site.
5 5 Supply, fixing, connection & testing of 40 Watt Numbers 50.00 1890.00 94500.00
LED Tubelight, Surface/ Pendent mounting LED
Battens in Extruded aluminium housing as per
instruction of Engineer Incharge at Site.
6 6 Supply, installation, testing & commissioning of Numbers 60.00 1614.00 96840.00
15 Watt Recess mounted downlighter with
pressure die-cast aluminium heat sink & PC
diffuser with integrated driver as per instruction
of Engineer Incharge at Site. (Round Type)
7 7 Supply, fixing & testing and commissioning of Numbers 16.00 670.00 10720.00
LED 12 W B22 CDL INVERTER BULB V2 as per
instruction of Engineer Incharge at Site.
8 8 Supply, wiring & testing of main wire by 2.5 sq Metre 2000.00 75.00 150000.00
mm, Single Core FR-LSH PVC Insulated Industrial
Grade Copper Conductor (Unsheathed) Flexible
Cables, 1100 Volts and earth continuity wire by
1.0 sq mm FR-LSH PVC Insulated Industrial Grade
Copper Conductor Conforming to IS: 694
concealed in wall through PVC rigid conduit pipe
not less than 20 mm dia as per instruction of
Engineer incharge at site.
9 9 Supply, wiring & testing of main wire by 4 sq mm, Metre 1500.00 87.00 130500.00
Single Core FR-LSH PVC Insulated Industrial Grade
Copper Conductor (Unsheathed) Flexible Cables,
1100 Volts and earth continuity wire by 1.0 sq
mm FR-LSH PVC Insulated Industrial Grade
Copper Conductor Conforming to IS: 694
concealed in wall through PVC rigid conduit pipe
not less than 20 mm dia as per instruction of
Engineer incharge at site.
10 10 Supply, wiring & testing of main wire by 6 sq mm, Metre 1000.00 100.00 100000.00
Single Core FR-LSH PVC Insulated Industrial Grade
Copper Conductor (Unsheathed) Flexible Cables,
1100 Volts and earth continuity wire by 1.0 sq
mm FR-LSH PVC Insulated Industrial Grade
Copper Conductor Conforming to IS: 694 through
PVC rigid conduit pipe/polythene pipe not less
than 20 mm dia as per instruction of Engineer
incharge at site.
11 11 Supply, installation, testing & commissioning of Numbers 80.00 1265.00 101200.00
10 watt LED Bulkhead luminaires, IP65 as per
instruction of Engineer incharge at site.
12 12 Supply, installation, testing & commissioning of Numbers 25.00 18420.00 460500.00
200 watt LED flood light luminaires complete with
pressure die cast aluminium housing, IP 66,
Luminous efficacy 120 lm/watt with heat sink
feature, surge protection etc including wire
connection as per instruction of Engineer
incharge at site.
KATIHAR DIVISION-ELECTRICAL/N F RLY
13 13 Supply, installation, testing & commissioning of Metre 150.00 1561.00 234150.00
Hot Dipped Galvanized Wire Mesh Cable Tray of
size (Depth- 54 x Width- 150) mm, made of
carbon steel (ASTM A510, Grade-1008 specified)
finished by electrozinc plating (ASTM B 633
specified) alongwith all accessories like suitable
type of splices, locking tab, divider coupler,
preclick, SWK, clamp, Tee, bend, bracket, nut,
bolts etc. Trays should comply standard EN ISO
1461: atleast 550 h of SST. Assemblies with
specific fire resistant properties must have an
E30-E90 certificate. Rod-dia must be from 3.9
mm to 5.9 mm or higher and as per site site
requirement and as per instruction of engineer
incharge at site.
14 14 Design, manufacture, display of wall /hanging / Square 300.00 2868.00 860400.00
floor mounting type LED illuminated sign / Foot
direction boards in half elliptical shape. The
display sheet shall be of unbreakable 040
translucent polycarbonate sheet of 2 mm
thickness. The text / graphics matter visibility
shall not be less than 160 deg. The approved
colour text and graphics shall be printed / router
cut on monomeric calendered vinyl of 70 mm
thickness and shall be firmly pasted on display
sheets. The mounting arrangement shall be
hanging, wall mounting, ceiling mounting, pole
mounting or floor mounting and as per site
requirement. The signage shall have the integral
mounting arrangements with sturdy structural
frame and ACP cladding on the back side of the
signage to avoid rusting and entry of dust. The
LED board shall have uniform illumination with 4-
8 W / sq. ft and with brightness more than
ambient light. Suitable size end cap of 1.5 mm
thick SS 304 should be provided. (Signage Board
should as per Railway Board Letter No. 2023/SD-
15 15 Erection and installation of wall / hanging / floor Square 300.00 287.00 86100.00
mounting type LED illuminated sign / direction Foot
boards in half elliptical shape. The display sheet
shall be of unbreakable 040 translucent
polycarbonate sheet of 2 mm thickness. The
text/graphics matter visibility shall not be less
than 160 deg. The approved colour text and
graphics shall be printed / router cut on
monomeric calendered vinyl of 70 mm thickness
and shall be firmly pasted on display sheets. The
mounting arrangement shall be hanging, wall
mounting, ceiling mounting, pole mounting or
floor mounting and as per site requirement. The
signage shall have the integral mounting
arrangements with sturdy structural frame and
ACP cladding on the back side of the signage to
avoid rusting and entry of dust. The LED board
shall have uniform illumination with 4-8 W / sq. ft
and with brightness more than ambient light.
Suitable size end cap of 1.5 mm thick SS 304
should be provided. (Signage Board should as per
Railway Board Letter No. 2023/SD-II/22/07/02
16 16 Supply, laying, commissioning & testing of GI pipe Metre 800.00 850.00 680000.00
100 mm medium guage with suitable fixing
arrangement by MS clamp of size 50x6 mm and
suitable size nut, bolt etc. (For protection of
cable) as per instruction of Engineer incharge at
KATIHAR DIVISION-ELECTRICAL/N F RLY
17 17 Supply, laying, commissioning & testing of HDPE Metre 800.00 70.00 56000.00
pipe 50 mm dia, PN-6 grade to be laid partly
along the p o l e / w a l l with suitable fixing
arrangement by MS clamp made of MS flat of size
50x6 mm and suitable size nut , bolt, washer etc
as per instruction of Engineer Incharge at site.
18 18 Supply & Erection of earth by 50 mm dia 3 Mtrs. Numbers 16.00 4349.00 69584.00
long (3.6 mm thickness) GI pipe, 32x6 mm GI
strip- 5 Mtrs, GI nuts, bolts including masonry
materials for earthing pit, salt, charcoal, soldered
end terminal etc. and construction of earth pit
covered with RCC cover slab12.7 mm thickness
and watering pipe as per Drg. No.-
PCEE/ELG/DRG/2024/1 Date:- 30.09.2024 and as
per instruction of Engineer Incharge at site.
19 19 Supply, fixing, testing & commissioning of 20 Set 24.00 2724.00 65376.00
amp Industrial plug & socket DB (CRCA/SS made)
complete with metal Plug, socket (3P) & MCB DP
20 amp. as per instruction of Engineer Incharge
20 20 Supply, fixing, testing & commissioning of 63 Set 8.00 9912.00 79296.00
amp Industrial plug & socket DB (CRCA/SS made)
complete with metal Plug, socket (3P/5P) & MCB
DP 63 amp. as per instruction of Engineer
Incharge at Site.
21 21 a) Supply, fabrication, erection, testing, Set 8.00 2005.00 16040.00
commissioning & painting of floor mounted
powder coated cubicle panel board (Modular look)
of suitable size (neither big nor small) ), outdoor
type with double door made of suitable size MS/GI
angle 50 x 50 x 6 mm, MS/GI flat 50 x 6 mm, 14
SWG MS sheet/Powder coated CRCA sheet with
provision of weather proof,rust proof,dust
proof,water proof having internal rubber gasket
with supply and fixing of following ACB/MCCB/Bus
bar/Meter etc. (Connections to be made by
copper strips, glands should be provided at cable
entry and exit, components should be
compartmentalized, Each compartment will be
provided with the door and pad locking
arrangement. The compartment illumination lamp
with door operated switch shall be provided for
each compartment. Panel board drawing
approval must be obtained with clear indication
of make of items of components):-
conforms to IS/IEC 60898:2002
Conforms to IS/IEC 60898 - 1:2002
Conforms to IS/IEC 60898 - 1:2002
KATIHAR DIVISION-ELECTRICAL/N F RLY
25 25 a) Supply, fabrication, erection, testing, Set 4.00 32916.00 131664.00
commissioning & painting of floor mounted
powder coated cubicle panel board (Modular look)
of suitable size (neither big nor small) ), outdoor
type with double door made of suitable size MS/GI
angle 50 x 50 x 6 mm, MS/GI flat 50 x 6 mm, 14
SWG MS sheet/Powder coated CRCA sheet with
provision of weather proof,rust proof,dust
proof,water proof having internal rubber gasket
with supply and fixing of following ACB/MCCB/Bus
bar/Meter etc. (Connections to be made by
copper strips, glands should be provided at cable
entry and exit, components should be
compartmentalized, Each compartment will be
provided with the door and pad locking
arrangement. The compartment illumination lamp
with door operated switch shall be provided for
each compartment. Panel board drawing
approval must be obtained with clear indication
of make of items of components):-
28 28 d) Copper bus bar 100 amps made of electrolytic Set 4.00 900.00 3600.00
grade copper consisting of 4 bars ( 3 Ph and
Neutral ) ( Bus bar should have insulation cover)
ammeter (0-500) amps with s/switch and CTs
31 31 Laying, commissioning & testing of HT/LT Metre 3000.00 55.00 165000.00
XLPE/PVC cable of different sizes partly along the
pole and partly through ground in cable trench by
excavation of ground below 1.5 mt from ground
level with suitable fixing arrangement by MS
clamp of size 50x6 mm and suitable size nut,
bolt. Loading, Unloading & Carrying of cable to
actual work site by contractor's own
arrangement. (Aluminium Crimping Socket should
be provided for each Cable Termination). (Cable
will be supplied by Railway)
32 32 Cutting of Road/Pucca/Hard Soil below (0.3 x 1) Metre 1600.00 298.00 476800.00
mt from ground level and make it good as original
with supply & execution of CC work (1:3:6) as per
instruction of Engineer incharge at site.
Schedule Schedule 3-PART-C (Under Jurisdiction of SSE/Elect./P/IC/KIR) (Station - PRNA & KIR)
Item- 1 Please see the item breakup
S No. Item Description of Item Unit Qty Rate Amount
1 1 Supply, wiring, testing & commissioning of Numbers 110.00 797.00 87670.00
concealed point wiring by FR PVC insulated and
unsheathed 1.5 sq mm, single core multi strand
copper wire with earth continuity wire by PVC
insulated and unsheathed 1 sq mm , single core
multi strand copper wire concealed on wall
through PVC rigid conduit pipe of dia not less
than 20 mm dia heavy duty including all types of
joints and bends as required, complete with 6
amps flush type controlling modular switch to be
mounted on modular GI inner plate and modular
mounting frame of suitable module as per
requirement complete to be concealed in wall as
per instruction of Engineer Incharge at site.
Existing wall should be cut and re-mended to
original finish by contractor's own material. a)FL
Point/LED Tube Point/LED Recess Light Point with
KATIHAR DIVISION-ELECTRICAL/N F RLY
3 3 Supply, wiring, testing & commissioning of Numbers 50.00 737.00 36850.00
concealed plug point on separate board complete
with 2 x 6 Amp modular socket and 6/10 amps
modular switch to be mounted on modular GI
inner plate 6M and 6M modular mounting frame
with GI box to be concealed in wall as per
instruction of Engineer Incharge at site. Existing
wall should be cut and re-mended to original
finish by contractor's own material.
4 4 Supply, wiring, testing & commissioning of Numbers 30.00 855.00 25650.00
concealed 6/16 amps power plug point on
separate board complete with modular 16 amps
switch (with indicator) and 6/16 amps 3 pin
combined shuttered socket to be mounted on
modular GI inner plate 4M or suitable size with
modular mounting frame to be concealed in wall
as per instruction of Engineer Incharge at Site.
5 5 Supply, fixing, connection & testing of 40 Watt Numbers 50.00 1890.00 94500.00
LED Tubelight, Surface/ Pendent mounting LED
Battens in Extruded aluminium housing as per
instruction of Engineer Incharge at Site.
6 6 Supply, installation, testing & commissioning of Numbers 60.00 1614.00 96840.00
15 Watt Recess mounted downlighter with
pressure die-cast aluminium heat sink & PC
diffuser with integrated driver as per instruction
of Engineer Incharge at Site. (Round Type)
7 7 Supply, fixing & testing and commissioning of Numbers 16.00 670.00 10720.00
LED 12 W B22 CDL INVERTER BULB V2 as per
instruction of Engineer Incharge at Site.
8 8 Supply, wiring & testing of main wire by 2.5 sq Metre 2000.00 75.00 150000.00
mm, Single Core FR-LSH PVC Insulated Industrial
Grade Copper Conductor (Unsheathed) Flexible
Cables, 1100 Volts and earth continuity wire by
1.0 sq mm FR-LSH PVC Insulated Industrial Grade
Copper Conductor Conforming to IS: 694
concealed in wall through PVC rigid conduit pipe
not less than 20 mm dia as per instruction of
Engineer incharge at site.
9 9 Supply, wiring & testing of main wire by 4 sq mm, Metre 1500.00 87.00 130500.00
Single Core FR-LSH PVC Insulated Industrial Grade
Copper Conductor (Unsheathed) Flexible Cables,
1100 Volts and earth continuity wire by 1.0 sq
mm FR-LSH PVC Insulated Industrial Grade
Copper Conductor Conforming to IS: 694
concealed in wall through PVC rigid conduit pipe
not less than 20 mm dia as per instruction of
Engineer incharge at site.
10 10 Supply, wiring & testing of main wire by 6 sq mm, Metre 1000.00 100.00 100000.00
Single Core FR-LSH PVC Insulated Industrial Grade
Copper Conductor (Unsheathed) Flexible Cables,
1100 Volts and earth continuity wire by 1.0 sq
mm FR-LSH PVC Insulated Industrial Grade
Copper Conductor Conforming to IS: 694 through
PVC rigid conduit pipe/polythene pipe not less
than 20 mm dia as per instruction of Engineer
incharge at site.
11 11 Supply, installation, testing & commissioning of Numbers 80.00 1265.00 101200.00
10 watt LED Bulkhead luminaires, IP65 as per
instruction of Engineer incharge at site.
12 12 Supply, installation, testing & commissioning of Numbers 25.00 18420.00 460500.00
200 watt LED flood light luminaires complete with
pressure die cast aluminium housing, IP 66,
Luminous efficacy 120 lm/watt with heat sink
feature, surge protection etc including wire
connection as per instruction of Engineer
incharge at site.
KATIHAR DIVISION-ELECTRICAL/N F RLY
13 13 Supply, installation, testing & commissioning of Metre 150.00 1561.00 234150.00
Hot Dipped Galvanized Wire Mesh Cable Tray of
size (Depth- 54 x Width- 150) mm, made of
carbon steel (ASTM A510, Grade-1008 specified)
finished by electrozinc plating (ASTM B 633
specified) alongwith all accessories like suitable
type of splices, locking tab, divider coupler,
preclick, SWK, clamp, Tee, bend, bracket, nut,
bolts etc. Trays should comply standard EN ISO
1461: atleast 550 h of SST. Assemblies with
specific fire resistant properties must have an
E30-E90 certificate. Rod-dia must be from 3.9
mm to 5.9 mm or higher and as per site site
requirement and as per instruction of engineer
incharge at site.
14 14 Design, manufacture, display of wall /hanging / Square 300.00 2868.00 860400.00
floor mounting type LED illuminated sign / Foot
direction boards in half elliptical shape. The
display sheet shall be of unbreakable 040
translucent polycarbonate sheet of 2 mm
thickness. The text / graphics matter visibility
shall not be less than 160 deg. The approved
colour text and graphics shall be printed / router
cut on monomeric calendered vinyl of 70 mm
thickness and shall be firmly pasted on display
sheets. The mounting arrangement shall be
hanging, wall mounting, ceiling mounting, pole
mounting or floor mounting and as per site
requirement. The signage shall have the integral
mounting arrangements with sturdy structural
frame and ACP cladding on the back side of the
signage to avoid rusting and entry of dust. The
LED board shall have uniform illumination with 4-
8 W / sq. ft and with brightness more than
ambient light. Suitable size end cap of 1.5 mm
thick SS 304 should be provided. (Signage Board
should as per Railway Board Letter No. 2023/SD-
15 15 Erection and installation of wall / hanging / floor Square 300.00 287.00 86100.00
mounting type LED illuminated sign / direction Foot
boards in half elliptical shape. The display sheet
shall be of unbreakable 040 translucent
polycarbonate sheet of 2 mm thickness. The
text/graphics matter visibility shall not be less
than 160 deg. The approved colour text and
graphics shall be printed / router cut on
monomeric calendered vinyl of 70 mm thickness
and shall be firmly pasted on display sheets. The
mounting arrangement shall be hanging, wall
mounting, ceiling mounting, pole mounting or
floor mounting and as per site requirement. The
signage shall have the integral mounting
arrangements with sturdy structural frame and
ACP cladding on the back side of the signage to
avoid rusting and entry of dust. The LED board
shall have uniform illumination with 4-8 W / sq. ft
and with brightness more than ambient light.
Suitable size end cap of 1.5 mm thick SS 304
should be provided. (Signage Board should as per
Railway Board Letter No. 2023/SD-II/22/07/02
16 16 Supply, laying, commissioning & testing of GI pipe Metre 800.00 850.00 680000.00
100 mm medium guage with suitable fixing
arrangement by MS clamp of size 50x6 mm and
suitable size nut, bolt etc. (For protection of
cable) as per instruction of Engineer incharge at
KATIHAR DIVISION-ELECTRICAL/N F RLY
17 17 Supply, laying, commissioning & testing of HDPE Metre 800.00 70.00 56000.00
pipe 50 mm dia, PN-6 grade to be laid partly
along the p o l e / w a l l with suitable fixing
arrangement by MS clamp made of MS flat of size
50x6 mm and suitable size nut , bolt, washer etc
as per instruction of Engineer Incharge at site.
18 18 Supply & Erection of earth by 50 mm dia 3 Mtrs. Numbers 16.00 4349.00 69584.00
long (3.6 mm thickness) GI pipe, 32x6 mm GI
strip- 5 Mtrs, GI nuts, bolts including masonry
materials for earthing pit, salt, charcoal, soldered
end terminal etc. and construction of earth pit
covered with RCC cover slab12.7 mm thickness
and watering pipe as per Drg. No.-
PCEE/ELG/DRG/2024/1 Date:- 30.09.2024 and as
per instruction of Engineer Incharge at site.
19 19 Supply, fixing, testing & commissioning of 20 Set 24.00 2724.00 65376.00
amp Industrial plug & socket DB (CRCA/SS made)
complete with metal Plug, socket (3P) & MCB DP
20 amp. as per instruction of Engineer Incharge
20 20 Supply, fixing, testing & commissioning of 63 Set 8.00 9912.00 79296.00
amp Industrial plug & socket DB (CRCA/SS made)
complete with metal Plug, socket (3P/5P) & MCB
DP 63 amp. as per instruction of Engineer
Incharge at Site.
21 21 a) Supply, installation, testing & commissioning of Set 8.00 2005.00 16040.00
12 way SPN Distribution Board, Flush/Surface
mounting, IP 43 grade protection with copper bus
bar, fully shrouded neutral bar, earth bar, cable
ties, metal double door as per IS 8623 - III with
supply and fixing of following RCBO/MCB's as per
instruction of Engineer Incharge at Site.
conforms to IS/IEC 60898:2002
Conforms to IS/IEC 60898 - 1:2002
Conforms to IS/IEC 60898 - 1:2002
25 25 a) Supply, fabrication, erection, testing, Set 4.00 32916.00 131664.00
commissioning & painting of floor mounted
powder coated cubicle panel board (Modular look)
of suitable size (neither big nor small) ), outdoor
type with double door made of suitable size MS/GI
angle 50 x 50 x 6 mm, MS/GI flat 50 x 6 mm, 14
SWG MS sheet/Powder coated CRCA sheet with
provision of weather proof,rust proof,dust
proof,water proof having internal rubber gasket
with supply and fixing of following ACB/MCCB/Bus
bar/Meter etc. (Connections to be made by
copper strips, glands should be provided at cable
entry and exit, components should be
compartmentalized, Each compartment will be
provided with the door and pad locking
arrangement. The compartment illumination lamp
with door operated switch shall be provided for
each compartment. Panel board drawing
approval must be obtained with clear indication
of make of items of components):-
28 28 d) Copper bus bar 100 amps made of electrolytic Set 4.00 900.00 3600.00
grade copper consisting of 4 bars ( 3 Ph and
Neutral ) ( Bus bar should have insulation cover)
29 29 e) Digital voltmeter (0-500) amps and Digital Set 4.00 5581.00 22324.00
ammeter (0-500) amps with s/switch and CTs
KATIHAR DIVISION-ELECTRICAL/N F RLY
31 31 Laying, commissioning & testing of HT/LT Metre 3000.00 55.00 165000.00
XLPE/PVC cable of different sizes partly along the
pole and partly through ground in cable trench by
excavation of ground below 1.5 mt from ground
level with suitable fixing arrangement by MS
clamp of size 50x6 mm and suitable size nut,
bolt. Loading, Unloading & Carrying of cable to
actual work site by contractor's own
arrangement. (Aluminium Crimping Socket should
be provided for each Cable Termination). (Cable
will be supplied by Railway)
32 32 Cutting of Road/Pucca/Hard Soil below (0.3 x 1) Metre 1415.00 298.00 421670.00
mt from ground level and make it good as original
with supply & execution of CC work (1:3:6) as per
instruction of Engineer incharge at site.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
NITforLiftHCROMLFAZRGRMPBNDPPRNARGJKIR.pdf Tender Paper
ATTACHMENT
GCCApril-2022PDFwithallACS_compressed.pdf
ATTACHMENT
NITforLiftHCROMLFAZRGRMPBNDPPRNARGJKIR.pdf
ATTACHMENT
Download all tender documents and submit your bid