Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.3 LAccepted-AOC | L1 | Accepted-AOC Lowest |
Tender Value
₹5.7 L
EMD Value
₹8,600
Closing Date
3 Sept 2021, 6:00 pmClosed
The Executive Engineer Electrical
O/o The chief Engineer, Harbour Engineering Electrical Division, Kamaleswaram,TVPM
Fisheries_Office of the Deputy Director of Fisheries Moplabay_Kannur_Providing E_Office facilities_Electrification
2021_HED_436144_1
25/HEED/2021-22/S
Open Tender
Electrical Works
Item Rate
30 days
Moplabay_Kannur
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,540
Yes
₹8,600
Yes
30 Nov 2021
25 Aug 2021
6 Sept 2021
25 Aug 2021
3 Sept 2021
25 Aug 2021
Amount
Engaging labourers for checking the wiring system, dismantling the damaged wiring installations and keeping the same safely as per the instruction of the departmental officers at site.Wireman
Engaging labourers for checking the wiring system, dismantling the damaged wiring installations and keeping the same safely as per the instruction of the departmental officers at site.Beldar
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required(Group C)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mm X 75mm)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mm X 75mm)
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box/CMS including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box/CMS including connections but excluding modular plate etc. as required.5/6 A switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box/CMS including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box/CMS including connections but excluding modular plate etc. as required.16A 1 way switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box/CMS including connections but excluding modular plate etc. as required.CAT 6 RJ 45 computer jack .
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box/CMS including connections but excluding modular plate etc. as required. RJ 45 frame
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following Modular base & cover plate on CMS as required.1 or 2 Module
Supplying and fixing following Modular base & cover plate on CMS as required.3 Module
Supplying and fixing following Modular base & cover plate on CMS as required.6 Module
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.3 x 1.5 sq. mm
Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.3 x 4 sq. mm
Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.6 x 4 sq. mm
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
Supply and fixing brass batten/angle holder including connection etc as required
Supply and fixing 7/9 W LED ,BC, lamp OSRAM or equivalent
Supply of ceiling fan of 1200 mm sweep Category B Ceiling fan excluding resistance type regulator
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable etc. as required.
Supplying and fixing extra down rod of 10 cm length G.I. pipe ,15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
Supplying and fixing following rating, double pole, 240 volts, 40A isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing steel sheet 4 way prewired vertical type double door TP&N MCB distribution board with MCCB as incomer for 415 volts on surface/ recess complete with loose wire box of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's, terminal connectors for all incoming and outgoing circuits, duly prewired with adequate size of FR PVC insulated copper conductor upto the terminal connector/ neutral link, earthing etc as required .
Supply, conveyance and fixing 25 - 40 A, 25 kA (Ics=100%Icu), 3 pole, MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL & SC conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).2+12way, Double door
Providing and fixing earth bus of 25 mm X 3 mm copper strip on surface for connections etc. as required.
Supplying 16 W LED Tube with box type fixtures Essential LED tube 1200 mm 16W 865 T8 API Philips or equivalent
Supplying suspended LED luminaire Philips SM 270 C LED 30S - 6500 PSU WH or equivalent
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc., including supplying and fixing ball and socket arrangement, 2 no. down rods of 20 mm dia X 1.6 mm thick steel conduit upto 30 cm length, painting and wiring the down rods and connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required.
Providing and fixing extra conduit down rod of 20 mm dia, 2 X 10 cm length wiring with 2 X 1.5 sq. mm FR PVC insulated, copper conductor, single core cable including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. (but without charcoal/ coke and salt) as required.
Supply and providing RCC covering slab covering slab of size 55x55x8cm constructed with the following for the inspection chamber of earth pit as required .Providing and laying in position reinforced cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required (excluding reinforcement).
Supply and providing RCC covering slab covering slab of size 55x55x8cm constructed with the following for the inspection chamber of earth pit as required .Providing 15mm thick cement plaster of mix 1:4 (1 cement : 4 fine sand) at all levels.
Supply and fixing 105 x 50 mm UPVC Cable Management System with base and lid LEGRAND or equivalent along with all required accessories as per the site condition on surface/recess
Supply and fixing 80 x 50 mm UPVC Cable Management System with base and lid LEGRAND or equivalent along with all required accessories as per the site condition on surface/recess
Supplying and drawing UTP four pair CAT 6 LAN cable in the existing surface/recess steel/ PVC conduit
Identifying cables, supply and crimping RJ 45 cable jack on the cable end and giving connection
Supply of Cat 6,2 metre patch cord
Supply of Cat 6,1 metre patch cord
Supply, installation, testing and commissioning of 230V AC, 3 KVA/2.4kW Online UPS Systems(Numeric Onfiniti , 1PH-1PH) Floor MountableDouble conversion Pure Online UPS System(72VDC or above) with Inbuilt IsolationTransformer ,Connecting in StandaloneConfiguration, Input Voltage 160V-280 VAC andoutputvoltage :230V +/-1% , battery using 12 VC10 rated Tubular , 6 nos ,100AH Quanta/Exidemake Tubular battery, recommended for 120minutes backup (Minimum VAH 7200) @ 2100Wload and suitable Battery Rack forhousing thebatteries. Offered UPS with ISO ,BIS,CEcertification& RoHS marking. Warranty: 3 yearonsite for UPS & 4 year for Battery
Supply, installing, commissioning of manageable switch SG350-28-K9 or equivalent 28 PORT GIGABIT manageable switch having 24 x 10/100/1000 + 4 x Gigabit SFP (2 combo) , L3 - Managed, 24x GbE (1000Base-T) | 4x SFP | Managed, VLAN-fähig, Rackmount, Enclosure Type:- Rack-mountable Voltage Required :-AC 120/230 V (50/60 Hz), Switching Capacity should be 56 Gbps,4096 active VLAN's ,RAM-512MB,Flash memory-256 MB flash,switch should be Manageable through CLI, web Interface and SSH.layer 3 switching,layer 2 switching,DHCP support,VLAN support,IGMP snooping,Do5 attack prevention,port mirroring,DiffServ support,weighted round robin(WRR)queuing,broad cast storm control,IPv6 support,spanning tree protocl(STP) support,rapid spaning tree protocol(RSTP)support,Multiple spanning tree protocol(MSTP) support,Trivial file trasfer protocol(TFTP)support,Acess control list(ACL)support,MLD snooping,SNMP,RMON,SNTP,Cisco Discovery Protocol,Auto Smart Ports
Supply, installation testing and commissioning wall mounting type dust and vermin proof enclosure 6 U rack system with standard accessories patch panel,cable manager , power strip, cooling fan, cable tray (Model 6U) suitable for installing 24port ethernet switch and patch panel.
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .