Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹17.1 L
EMD Value
₹17,125
Closing Date
3 Dec 2026, 5:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Chief Officer,Sachin Notified Area
Annual Rate Contract For The Work Of Maintenance, Repair And Replacement Of Electrical Equipment/Circuit/ IT Equipment/Split Type Air Conditioning Machines, Storage Type Water Coolers & RO/DG Set At Sachin Notified Area Office Building & Fire Station Of GIDC Sachin 2026-27.
361846
05 of 2026-27(Serial No. 11)
Open
Electrical and Maintenance Works
Works
Surat
14 documents required · 14 mandatory
₹1,062
Chief Officer, Sachin Notified Area
₹17,125
3 Dec 2026
2 Nov 2026
7 Dec 2026
2 Nov 2026
18 Nov 2026
2 Nov 2026
120 days
Name of Work :-Annual rate contract for the work of maintenance, repair and replacement of electrical
equipment/circuit/ IT equipment/Split type Air Conditioning Machines, Storage Type Water
Coolers & RO /DG Set at Sachin Notified Area Office building and Fire Station of GIDC Sachin
Sr. Item Description of Items Rate/ Unit Amount
No. No. Unit QTY
Point wiring for Light / Fan/ Bell/ Primary Point with 2-1.5
sq. mm & earthwire of 1.5 sq. mm (green) both are of ISI
marked 1.1 kv grade FRLS PVC insulated multistrand
copper wires, in following type of pipe to be erected
concealed in /flushed on wall/ceiling , complete with 6A
1 1 Tissino Type ISI marked flush type switch / bell push and Pt. 10.00 425.21
accessories erected on Metal / PVC Box covered with 3 mm
thick PC(Polycarbonet) /Acrylic sheet. with necessary Lamp
holder/ceiling rose / H.D. Connector as directed. (a) with
medium class Rigid PVC pipe and accessories erected
flushed on wall/ceiling complete
Point wiring for Light / Bell with 2-1.5 sq.mm & earthwire
of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade
FRLS PVC insulated multistrand copper wires, in following
type of pipe to be erected concealed in/ on surface on
wall/ceiling complete with 6A Modular type switch / bell
push & accessories and earth continuity of following type,
erected on PVC / Metallic box, single mounting base frame
covered with textured/metallic front plate modules erected
on / in wall / ceiling as per pipe erected, with necessary
Lamp holder/ceiling rose / H.D. Connector as directed. (a)
with medium class Rigid PVC pipe and accessories erected
flushed on wall/ceiling complete Cat-III
Point wiring for FAN with 2-1.5 sq.mm & earth wire of
sq.mm (Green) both are of .ISI marked 1.1 KV Grade FRLS
PVC insulated multistrand copper wires, in following type of
pipe to be erected concealed in / flushed on wall/ceiling
complete with 6A Modular type switch and hum free EME
four or more step type electronic fan regulator with
3 3 separately mounted and accessories with earth continuity of Pt. 5 765.58
following type erected on PVC / Metallic box, single
mounting base frame covered with textured/metallic front
plate modules erected on /in wall / ceiling as per pipe erected.
with necessary ceiling rose / H.D.Connector as directed. (a)
with medium class Rigid PVC pipe and accessories erected
flushed on wall/ceiling complete Cat-III
Point wiring for Individual Plug with & earthwire of
sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS
PVC insulated multistrand copper wires, in following type of
to be erected concealed in / on surface of wall / ceiling
complete with Modular type switch & 5 pin Plug erected on
4 4 PVC / Metallic box covered with appropriate front plate Pt. 5
modules erected on / in wall / ceiling as per pipe erected with
following type of accessories. [I] For 6A Plug and 6 a switch
with 2-1.5 sq.mm Cu. Wire (a) with medium class Rigid
PVC pipe and accessories erected flushed on wall/ceiling
[II] For 16A Plug and 16 amp switch with 2-2.5 sq.mm Cu.
Wire from mcb db board.
[III] For 16A Plug and 16 amp switch with 2-4 sq.mm Cu.
6 4-B Wire with 2.5 sq.mm ( green) earthing wire (a) with medium Pt. 5
class Rigid PVC pipe and accessories Cat-III
Point wiring for Looped Plug with 6A Modular type switch
& 5 pin socket erected on PVC / Metallic box, single
7 5 mounting base frame covered with textured / metallic front Pt. 5
plate modules erected on / in wall / ceiling with following
type accessories Cat-III
Providing & erecting following type of Modular Type
8 6 Accessories with necessary connection. As desired by Ea 25
Engineer In charge (1) 6 Amp. SP one way switch
9 6-A (2) 16 Amp. SP one way switch Ea 15 51.51
10 6-B (3) 6/16Amp. Universal socket Ea 15 82.82
11 6-C (4) 6 A socket Ea 8 42.42
12 6-D (5) LAN cable connector with ferule Ea 10 36.36
Providing and erecting ISI mark Medium class RIGID PVC
PIPES of following size complete to be erected on/in wall or
13 7 ceiling erected with necessary PVC fittings & Junction Mtr. 30
boxes fixed with adhesive solution & Clamps with following
dia of pipes, in approved manner as directed (b) 25 mm
Mains with 1.1 KV grade FRLS PVC insulated ISI marked
stranded Copper conductor wire in following type of pipe to
be erected concealed in /flushed on wall/ceiling, with 1.5 sq.
14 8 mm copper conductor FRLS PVC insulated stranded wire of Mtr. 180
green colour for earth continuity of following size (a) with
medium class Rigid PVC pipe and accessories (a) 2 wire
Mains with 1.1 KV grade FRLS PVC insulated ISI marked
stranded Copper conductor wire in following type of pipe to
be erected in / on wall / ceiling with 2.5 sq. mm copper
conductor FRLS PVC insulated stranded wire of green
colour for earth continuity of following size(a) with medium
class Rigid PVC pipe and accessories (a) 2 wire 4 sq. mm
17 9-A (b) 2 wire 6 sq. mm Mtr. 90 184.83
Supplying & erecting approved make LAN cable of
18 10 following size in existing pipe as per direction [E] CAT - 6 Mtr 300 94.94
Providing & erecting Switch board for Computer or electric
apparatus consisting of following modular type accessories
mounted with PVC / Metallic concealed/open box with
single mounting base frame covered with textured/metallic
/white front plate, modules erected with necessary
connections as directed(1)1 no. 6A/16A universal plug-
switch combined., (2) 3 nos. 6A Switch, (3) 3 nos. 6A 5 pin
Plug [B] For Modular Type Accessories CAT-iii
Supplying & erecting Electronic Type Cordless Call Bell
erected on PVC/Metal board having portable bell push
working on D.C. & bell on 230V A.C. supply with cells /
Supplying and erecting LED indoor fittings with LEDs of
wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB,
with housing used as a heat sink shall be made of thick sheet
Steel conforming to IS: 513/CRCA/ aluminium die cast powder
coated and high U.V. & corrosion resistance with diffuser with
21 13 company mark/name 160V to 270V, Power Factor more than Ea. 50 373.70
0.95, THD < 15%, CCT 3000 K to 6500K, Luminaire efficacy>
85 lumens/watt ,LED LED driver efficiency > 85% (fitting
required LM-79 & LM-80 Certificates) (NOTE: Below
description have shown ranges of Wattage capacity of LED
fittings. The Engineer incharge may select any wattage capacity
between the ranges shown.) {A} Tube Light with integral driver
(iv) 22-24 watts, surge -2 KV,IP-20, Cat-III
22 13-A [v]36-40 watts, Surge -2 Kv,IP-20 conventional 4 feet cat III Ea. 15 535.30
Supplying and erecting LED indoor fittings with LEDs of
wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB,
with housing used as a heat sink shall be made of thick sheet
Steel conforming to IS: 513/ CRCA/aluminium pressure die
cast powder coated and high U.V. & corrosion resistance
with diffuser housed in aluminium casted body with
company mark/name 160V to 270V,Power Factor more than
0.95, THD < 15 %, CCT 3000 K to 6500K, Luminaire
efficacy> 85 lumens/watt, LED driver efficiency > 85 % (
fitting required LM-79 & LM-80 Certificates)(NOTE:
Below description have shown ranges of Wattage capacity
of LED fittings.The Engineer incharge may select any
wattage capacity between the ranges shown.) (A) Square/
Circular shaped Surface/Recessed Mount Downlight with
provision for spring loaded mounting clips complete.IP20
(iii) 16-20 watts, Surge-2 KV Cat-III
24 14-A (iv) 22-24 watts, Surge-2 KV Cat-III Ea. 50 758.51
(B) LED Panel Light with provision for Plane front frame
25 15 with translucent cover fixed to housing complete.IP20 (vi) Ea. 6 1794.77
36 watts, 24" x 24", Surge-2 KV
Supplying and erecting LED street light / Flood light fittings
with High power White LEDs wattage of 3 Watt and above
assembled on single MCPCB, efficiency more than 130 lm/w
and corrosion free High pressure die cast aluminum housing
with smooth finish powder coated and heat sink extruded
aluminium with diffuser and Polycarbonate optics/ lenses,
with toughened glass with company mark/name engraved or
embossed 160 to 270 V,Power Factor more than 0.95, THD
< 10 %, CCT 3000 K to 5700K,Uniformity ratio >0.45,
26 16 Luminaire efficacy> 100 lumens/watt . LED driver Ea. 4 4096.56
efficiency > 85 %.( fittings required LM-79 & LM-80
certificates)(NOTE: Below description have shown ranges
of Wattage capacity of LED fittings.The Engineer incharge
may select any wattage capacity between the ranges shown.)
(C) Post Top Lantern LED fitting comprises of finish cast
aluminum spigot and spun aluminum canopy fixed with opal
polycarbonate, pipe arrangement for vertical mounting
driver and accessories wired upto terminal block.IP
(b) LED Bollard fittings of minimum height 600 mm &
dia.100mm having polycarbonate clear/milky diffuser
mounted on 3mm thick aluminium finished powder coated
pipe with base plate 160x160mm with erection by
M8x75mm fastner with required RCC foundation.IP65 for
to 20 watt ,surge-4kv- cat-III
Supplying and erecting LED street light / Flood light fittings
with High power White LEDs wattage of 3 Watt and above
assembled on single MCPCB, efficiency more than 130 lm/w
and corrosion free High pressure die cast aluminum housing
with smooth finish powder coated and heat sink extruded
aluminium with diffuser and Polycarbonate optics/ lenses,
with toughened glass with company mark/name engraved or
embossed 160 to 270 V,Power Factor more than 0.95, THD
28 18 < 10 %, CCT 3000 K to 5700K,Uniformity ratio >0.45, Ea. 10
Luminaire efficacy> 100 lumens/watt . LED driver
efficiency > 85 %.(fittings required LM-79 & LM-80
certificates) (NOTE: Below description have shown ranges
of Wattage capacity of LED fittings.The Engineer incharge
may select any wattage capacity between the ranges shown.)
(A) Street Light (IP-65), Surge protection -4KV integral and
,Light must have 440VAC line supply with over-voltage
protection. (i) 36-48 watts Cat-III
Providing and erecting Approved make Four pole moulded
case circuit breaker having breaking capacity ICU of 25 KA.
at 415V, having normal current rating up to 25A to 100A.
29 19 with Fixed thermal & magnetic release suitable to work on Ea. 1
A.C. supply 50 Hz. with all internal connections, spreader
tinned copper & complete erected in existing 16 G.M.S.
housing. ICS=100% of ICU only
Approved make Four pole moulded case circuit breaker
having breaking capacity ICU of 35 KA. at 415V. having
normal current rating up to 125A. with Fixed thermal &
magnetic release suitable to work on A.C. supply 50 c/s. with
all internal connections & complete erected in existing
G.M.S. housing. ICS=100% of ICU only
Supply of Approved make Iron Clad or metal clad four pole
31 21 change over switch 415V. confirming to IS of following Ea. 1
capacity (B) 100 A / 125A /160A Cat III
Miniature circuit breaker single pole 6A to 32A suitable to
operate on 240 V A.C. system and having breaking capacity
10 KA to be erected in existing box. confirming to IS
8828/1996 with ISI Mark CAT-III
Providing & erecting 240 V MCB double pole switch for
motor & inductive load (C Curve) having 10 KA breaking
capacity & confirms to IS : 8828 in existing box having
following capacity (A) 6 to 32 AmP. Cat-III
34 23-A (B) 40 Amp. CAT-III Ea. 2 362.59
Providing & erecting 415V MCB Four Pole Switch for
Lighting Load (B curve) having 10KA breaking capacity &
confirms to IS :8828 in existing box having following
capacity (a) 6 to 32 Amp.CAT=III
36 24-A (b)40 Amp CAT-III Ea. 5 702.96
Providing & erecting 415 V MCB Four Pole for Motor &
Inductive Load (C Curve) having 10KA breaking capacity
& confirms to IS :8828 in existing box having following
capacity (c)63 Amp.
Providing and erecting Approved make RCCBs conforming
to IS: 12640 and having sensitivity of 30 mA and Short
Circuit withstand capacity of 10 KA and suitable for
operation on 3 phase and neutral 415V,50Hz. having
characteristic of quick action & tripping with all advance
feature & do not incorporate any electronic component for
following Max. rating erected as directed. (ii) 40Amps. FP
39 26-A (iii) 63 Amps. FP,CAT-III Ea. 4 3344.11
Providing and erecting required size Aluminium strip for
40 27 earthing of H.T. , OCB / ACB / Transformer, LT panel board, Kg. 10 225.23
Motors etc. using copper clamp.
Supplying & erecting in earthpit of minimum bore dia.
225mm size ASH or approved make Safe Earthing Electrode
consisting Pipe-in-Pipe Technology as per IS 3043-1987
made of corrosion free G.I.Pipes having Outer pipe dia of
80 mm having 80-200 Micron galvanising, Inner pipe dia of
40 mm having 200-250 Micron galvanising, connection
terminal dia of 14 mm with constant ohmic value
surrounded by highly conductive compound with high
charge dissipation suitable for following type of
applications. [A] For electrical installation up to 440 V
Length of Pipe - 1 Mtr. Back filling compound - 1 Nos. of
Providing and erecting FRLS-XLPE (IS:7098)(I)-88 ISI
armoured cable multistrand Aluminium conductor for
42 29 kV. to be laid on wall with necessary clamps or in existing Mtr. 90 229.27
trench / pipe of following size of cables (B) 4 core 25 Sq.
Providing and erecting FRLS-XLPE(IS:7098)(I)-88 ISI
armoured cable multistrand Aluminium conductor for
43 30 kV. to be laid on wall with necessary clamps or in existing Mtr. 30 454.50
trench / pipe of following size of cables. (D) 3 1/2 core
Sq. mm ( 35 Sq. mm 1/2 core)
Solderless crimping type Aluminium lugs conforming to IS
suitable for cable of following size evenly crimped with high
44 31 pressure tool & connected to switchgear terminals with Ea. 10 6.06
brass/cadmium plated nut bolts in an approved manner. (A)
Providing & erecting Approved make Ceiling Fan with
double ball bearing ISI mark with Condenser 230 volt
A.C.50 Hz 1200 mm sweep complete having 3 blades
aluminium body and blade sets having ornamental design
shanks , canopy erected with earthing. [ Make shall be
approved by Engineer in Charge]
Supplying and erecting 19 / 20 mm. nominal bore Medium
Class M.S. Pipe down rod erected duly painted for fan
complete with necessary 24/ O.20, 3 core flexible wire with
Supplying & erecting Fan Hook of 10 mm M.S. Round bar
grouted in RCC slab with Making the site as original.
Supplying & erecting fan hook box of 10 mm M.S. round
bar bounded to the RCC bars up to 50mm length each side
51 35 and pierced through a 16 Gauge M.S. box / Heavy Duty PVC Ea. 5 108.07
box complete erected concealed in Ceiling with necessary
Providing Fan clamp of 30 x 5 mm flat of required length &
52 36 10 mm M.S. Bolt & Nuts erected with necessary hook of 10 Ea. 5 98.98
mm M.S. Round Bar.
Providing 2.5mm.thick laminated acrylic sheet to cover the
fan hook or Fan box.
Supplying & erecting approved make low noise decorative
54 38 exhaust fan having size 250mm with 1350 RPM with square Ea. 10 1703.87
frame ABS body with inbuilt lowers & square frame.
Removing the installed Ceiling fan / Exhaust Fan for
55 39 servicing / repairing from ceiling and reinstalling the same Ea. 10 43.43
after making in working condition.
Rewinding of Any fan by using supper enamelled copper
wire and over hauling and putting in working order with
original speed with guarantee for one year including credit
of D.M. retained by Agency.
Replacing the bearing/ bushing of Ceiling fan and putting
57 41 the fan in working order including credit of D.M. retained by Ea. 10 103.02
Agency. (a) Bearing
58 41-A (b) Bushing Ea. 10 43.43
Replacing condenser for ceiling fan/ Exhaust Fan / Pedestal
59 42 Fan / Table Fan / Cabin Fan {Credit of D.M. retained by Ea. 25 64.64
Replacing the bearing/ bushing of Table fan Pedestal Fan
60 43 /Exhaust Fan and putting the fan in working order including Ea. 10 85.85
{Credit of D.M. retained by Agency.} (a) Bearing
61 43-A (b) Bushing rubber, ring, washers Ea. 10 51.51
Replacing approved make fan regulator resistance type for
Ceiling fan {credit of D.M. retained by Agency.}
Supplying and erecting Direct-on-line, Starter with
15A.rating contractor and with 4-14A. range, directly
63 45 operated thermal overload relay in sheet steel enclosure for Ea. 2 2046.26
3phase 415V.50 Hz. A.C. motor up to 7.5 H.P.complete
erected on P.W. Block with necessary connection.
Providing and erecting AC-3 duty 3 pole power contactor
with 2 NO & 2 NC aux contacts complete with 415V/220V
operating coil suitable for (L&T, BCH,T.C., Siemens, C&S
make). (a) for 25/32 A rating.
All inclusive comprehensive maintenance cost for the period
65 47 of one year for the mono block pump sets & starters/starter Ea. 2 1644.28
panel & Wiring & Cables of following HP Capacity (B) 3 hp
Supplying and erecting approved make Automatic Liquid
Level Controller 6A with sensor testing as per instructions of
66 48 engineer in-charge on site, complete with wiring connection Ea. 2 2355.32
with existing wires, with copper conductor for pump to upper
and lower tank.
Repair and Maintenance of LED Sign Board at GIDC Office
Supplying & testing wireless microphone system for
MHz FM operation With effective range 200 feet with
microphone having facility for frequency adjustment &
receiver with LED indicator Telescopic antenna with battery
cells. [Approved by Competent Authority i.e. not Below the
rank of Executive Engineer]
Supplying & erecting push button type telephone instrument
having speaker phone Caller ID & hands free dialing system
69 51 & 30 memories with display system Single line [Approved Ea. 5 565.60
by Competent Authority i.e. not Below the rank of Executive
All inclusive comprehensive maintenance of 62.5 KVA
rating DG Set for 1 year which includes 1] Replacing the fuel
filters and Oil Filters 2] Checking the alignment and tappet
70 52 settings 3] Checking the carbon brushes/AVE. 4] Checking Each 1 80283.82
the Oil Level and Replacing the Oil. 5] Leakages In/Out
Cylinders. 6] All electric wiring including AMF panel if
available. 7] Dynamo steeting. 8] RPM setting, Frequency
and Voltage adjustment. 9] Replacing material like Fuel
Filters, gasket, tappet covers, diode rectifiers, bridge
rectifiers, Air filter, diesel filter if found defective and/or not
in working condition. 10] Kindly note that Labour with
spares is included in the above. 11] ]Major overhauling and
top overhauling shall be included in the scope of the Agency.
12] Replacement of the batteries is included in the scope of
the agency. (H) Continuous Rating of 62.5 KVA
71 52-A (B) Continuous Rating of 15 KVA Each 1 40243.75
Wi-Fi System : Supply, Installation, testing &
commissioning of Wire less WiFi Router with below
specification Networking Interface : (1) 10/100 Ethernet Port
Buttons : Reset Antennas ,Power Method : Passive Power
72 53 over Ethernet (12-24V) Power Supply : Included 24V, 0.5A Ea. 4 11548.08
PoE Adapter Maximum Power Consumption : 6 W
Maximum TX Power : 27 dBm BSSID : Up to Four Per
Radio Power Save : Supported Wireless Security : WEP,
WPA-PSK, WPA-TKIP,WPA2 AES.
Operator Semi Skilled Zone-II [ 1 wireman for each office. Mon
Total 1 office in Sachin circle. ths
AMC For Repairing and Servicing charges with
comprehensive online 10 KVA Un-interruptible Power
Supply system comprising flat cum-boost charger, static
Inverter. The charger having operating capacity for input
415V AC & inverter having output 23OV,5O Hz Ac with
0.8 load power factor with battery, over under voltage output
with over load & short circuit protection equipment., having
Parallel Operation Kit
AMC For Repairing and Servicing charges with
comprehensive 50KVA Servo Stabilizer having I/P Voltage
75 56 range from 340-480 and Output of 415 Volts , having Job. 1 65713.01
Accuracy of + 1%, with Frequency of 47 to 53 Hz, Response
Time 10 milli Seconds Maximum.
76 57 Supply Of Battery For UPS 12V 42Ah And Installation Ea. 12 6891.87
All inclusive comprehensive maintenance cost for the period
of one year for ceiling fan inclusive cost of to and fro
77 58 transportation & inclusive of dismantling & re-erecting on Ea. 51 137.36
the proper location. Dismantled material to be retained by
All inclusive comprehensive maintenance cost for the period
of one year for Exhaust fan, Bracket fan, Pedestal fan
78 59 inclusive cost of to and for transportation & inclusive of Ea. 16 253.51
dismantling & re-erecting on the proper location. Dismantled
material to be retained by agency
(1) The All inclusive comprehensive maintenance cost
covers the yearly maintenance cost of the electrical
machineries with material & Labour cost including
preventive maintenance. The cost covers entire installation
from outlet of main switch to electrical machine.. (3) All
inclusive comprehensive maintenance cost of Window type
/ Split type Air conditioners & Water coolers covers the
yearly maintenance & preventive maintenance with all
required painting materials & labours. including sheet metal -
work, refrigerant gas , compressor & all the contains parts.
The cost covers entire installation from outlet of main switch
to the Unit. (4) For A.M.C. of electrical installation Yearly
rates not covered in following items. For such items rate shall
be derived considering the current S.O.R. cost as capital cost
& A.M.C. yearly rate shall be derived at 5% Cost for
estimation purpose only. 1.0 Ton Capacity Split Type A/c.
(A) Charges for breakdown Maintenance as per requirement
throughout the year
(B) Charges for 1st Routine Maintenance of Dry Services
81 60-B between date of commencement to 3rd Months from date Ea. 1 141.40
of issue of work order.
(C) Charges for 2nd Routine Maintenance of wet Services
with water or Chemical as per site requirement Services
between 3rd months to 6th Months from date of issue of
(D) Charges for 3rd Routine Maintenance of Dry Services
83 60-D between 6th months to 9th Months from date of issue of Ea. 1 141.40
(E) Charges for 4th Routine Maintenance of wet Services
with water or Chemical as per site requirement Services
between 9th months to 12th Months from date of issue of
85 61 1.5 Ton Capacity Split Type A/c.
(A) Charges for breakdown Maintenance as per requirement
throughout the year
(B) Charges for 1st Routine Maintenance of Dry Services
87 61-B between date of commencement to 3rd Months from date Ea. 7 144.43
of issue of work order.
(C) Charges for 2nd Routine Maintenance of wet Services
with water or Chemical as per site requirement Services
between 3rd months to 6th Months from date of issue of
(D) Charges for 3rd Routine Maintenance of Dry Services
89 61-D between 6th months to 9th Months from date of issue of Ea. 7 144.43
(E) Charges for 4th Routine Maintenance of wet Services
with water or Chemical as per site requirement Services
between 9th months to 12th Months from date of issue of
91 62 2.0 Ton Capacity Split Type A/c.
(A) Charges for breakdown Maintenance as per requirement
throughout the year
(B) Charges for 1st Routine Maintenance of Dry Services
93 62-B between date of commencement to 3rd Months from date Ea. 9 171.70
of issue of work order.
(C) Charges for 2nd Routine Maintenance of wet Services
with water or Chemical as per site requirement Services
between 3rd months to 6th Months from date of issue of
(D) Charges for 3rd Routine Maintenance of Dry Services
95 62-D between 6th months to 9th Months from date of issue of Ea. 9 171.70
(E) Charges for 4th Routine Maintenance of wet Services
with water or Chemical as per site requirement Services
between 9th months to 12th Months from date of issue of
All inclusive comprehensive maintenance cost for the period
97 63 of one year for the water Cooler of following Capacity (B) Ea. 1 3339.06
120 / 150 Ltr capacity
All inclusive comprehensive maintenance cost for the period
of one year for the Reverse Osmosis water purification
system up to 50 Ltr/ Hr capacity. Inclusive replacing and
98 64 cleaning of membranes , change of filter , uPVC pipe fitting Ea. 1 10478.21
and booster pump replacing one time in twelve month and
servicing of RO System of following capacity( 6 Services in
Twelve months ) (C) 50 Ltr Capacity
Supplying and erecting approved make new power saver
rotary sealed type compressor suitable for operation on
220/23OV. 50 c/s. A.C. supply for 1.5 Ton capacity
window/ Split type A.C.
Supplying and erecting approved make new power saver
rotary sealed type compressor suitable for operation on
220/23OV. 50 c/s. A.C. supply for 2.0 Ton capacity
window/Split type A.C. (A) Rotary compressor
Supplying and replacing the defective Compressor (which is
cut) should be replaced by new power saver rotary
compressor by manufacturers factory repaired compressor
(b) for 4536 kcal / hr. ( 1.5 ton) refrigeration effect
Replacing old and unserviceable fan motor by new 1/6 H.P.
102 68 two speed Fan motor, fan of 350 to 1200 CFM flow suitable Ea. 4 2136.15
for A.C. machine.
Replacing unserviceable running capacitor of 36 µF to 50 µF
103 69 up to 2.5H.P. compressor motor for A.C. machine up to 2 Ea. 10 506.01
Ton. And for Single Phase Motor
Replacing air filter for A.C. machine (a) PVC / NYLON /
Providing and erecting Air Cooled Condenser unit having
face area of 0.235 Sq.Mtr. made out of 27 / 30 gauge copper
tube and cover with Aluminium fins of 12-13FPI (a) for
TR A.C. Machine with 3/4 Row deep Coil
106 71-A (b) For 1.5 TR A.C. Machine with 3/4 Row Deep coil Ea. 4 4006.67
107 71-B (c) For 2.0 TR A.C. Machine with 3/4 Row Deep coil Ea. 2 4451.07
108 72 repairing of PCB of remote control of split ac machine Ea. 5 985.76
Replacement of defective remote control panel assembly
unit of Split air conditioner.
Repairing cost of PCB Circuit of Indoor Unit for Inverter
110 74 Type 3 Star rating Split A.C. Machine up to 2.2 TR Ea. 12 2183.62
Shifting of Split A.C. The Scope includes dismantling,
shifting, re-installing & re-commissioning of the units
111 75 including topping up of Refrigerant gas, minor civil work Ea. 2 1969.50
wiring existing piping M S Stand electrical cabling with PVC
drown piping for 1.00, 1.5 & 2.0 TR capacity.
Replacing the defective indoor unit body by supplying and
erecting new complete set of body up to 2.0 TR
Overhauling and servicing the Split type A.C. MACHINES
by Chemical cleaning of the condenser, cooling coil etc. by
Veni clean/ Eq. material, water & cleaning all necessary
parts and putting the machine in working order.
Replacement of defective Osillating louvers & motor
114 78 connecting assembly of Split air conditioner up to 2.0 TR Ea. 2 916.07
Dismantling the existing split type air conditioner of any type
115 79 and capacity safely without any damages and making the site Ea. 2 282.80
Replacing old and unserviceable fan motor by new 1/10 to
1/12 H.P., 1250 RPM fan motor for water cooler.
Rewinding 1/10 to 1/12 H.P., 1250 RPM fan blower motor
of water cooler using supper enamelled cooper Core with
new bushes complete putting in working order after
varnishing and testing.
Flushing the line, leak testing, leak stopping, vacuuming,
dehydrating and charging the gas in the refrigeration system
for water cooler machine including replacement of
unserviceable liquid strainer.
Replacing unserviceable 25 to 36 µF running capacitor for
1.5H.P. compressor motor of water cooler.
Replacing the front rusted cover by new front cover of
Stainless steel suitable for water cooler.
Spray painting of water cooler with hammertone approved
quality of colour including black painting of rear cover
Supplying and erecting condenser unit Air cooled indigenous
122 86 type having 9.5 mm OD (nominal) copper condenser tube Ea. 3.0 2946.17
and Aluminium fins complete suitable for water cooler.
Replacing unserviceable water tank assembly of stainless
steel with necessary insulation surrounding the tank body of
water cooler of following capacity. (C) 150 Ltrs cooling
capacity./150 Ltrs storage capacity
124 88 Providing Row water booster pump for 50 Ltr. R.O. system Ea. 2.0 4225.84
125 89 Providing Membranes for 50 Ltr. R.O. System Ea. 5.0 3775.38
Repairing and servicing labour chrges for 50 Ltr. R.O.
127 91 Providing Power Supply Adaptor for 50 Ltr. R.O. System Ea. 2 779.72
Repairing high pressure pump upto 1 H.P. operating on
128 92 230V A.C. ,50 Hz supply,winding & Bearing100 to 250 Ltr. Job. 2.0 4665.19
Industrial R.O. Plant
Repairing solenoid valve and replacing coil 100 to 250 Ltr.
Industrial R.O. Plantt
Providing and Erecting 20" wound and spun Cartridge
to 250 Ltr. Industrial R.O. Plant
Repairing and servicing labour chrges for 50 Ltr. R.O.
The all inclusive comprehensive annual maintenance
contract cost covers yearly maintenance of solar PV
Modules, Inverter, wiring, earthing, switchgears, etc with
material and labour cost including preventive maintenance.
The cost covers entire installation. AMC also includes
132 96 monthly site visit and inspection of project with submission 10.0 2782.55
of inspection and solar generation report. All parts should be
replaced/repaired if found faulty within specified time.
Agency has to provide necessary licening work for warranty,
power, Bidirectional meter etc (A) 1KW-10KW System in
133 96-A (B) 11KW-20KW System in Office Building 20.0 2568.43
Supply, Installation, Testing & Commissioning Of 6 MP
Varifocal IP Bullet Camera
Supply, Installation, Testing & Commissioning Of 4MP
Dome Camera with Camera Safe Box
Supply, Installation, Testing & Commissioning Of 14"
Supply, Installation, Testing & Commissioning Of Camera
Supply, Installation, Testing & Commissioning Of UPS
Supply, Installation, Testing & Commissioning Of
Channel NVR 2 Sata
Supply, Installation, Testing & Commissioning Of
Channel NVR 4 Sata
Supply, Installation, Testing & Commissioning Of Poe
Supply, Installation, Testing & Commissioning Of Poe
Supply, Installation, Testing & Commissioning Of Poe
Supply, Installation, Testing & Commissioning Of
Surveillance HDD 04 TB
Supply, Installation, Testing & Commissioning Of
Surveillance HDD 10 TB
Supply, Installation, Testing & Commissioning Of Power
Board 6A, 4 Plug And Switch
I / We agree to carry out the above work at ____________ % above the estimated rate ((In Words)
_________________________________________________) percentage above the Estimated Tender Rate.
I / We agree to carry out the above work at ____________ % below the estimated rate ((In Words)
_________________________________________________) percentage below the Estimated Tender Rate.
Estimated Amount Estimated Amount
Put to Tender Rs. 17,12,454.44 Put to Tender Rs.
Add % Above Rs.______________ Deduct % Below Rs. ______________
Net Amount Rs.______________ Net Amount Rs. ______________
Net In Figure Rs. _____________ Net in Figure Rs. ______________
I / We have read the Condition mentioned in this tender and agree to abide by the same.
Note:- Estimated Cost put to tender is excluding GST and Including all other Taxes. GST will be paid additional
as per applicable rate prevailing from time to time and all other statutory liabilities are part of estimated
cost and will be bound by bidder. Prospective bidder may please by read carefully, app prevailing policy
/Government Resolution (GT) of Govt. of Gujarat (GoG)/competent authority, regarding GST and
submit the price bid offer accordingly.
Signature of Contractor with Seal
Sachin Notified Area,
G.I.D.C.-SACHIN
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
Tender Document .pdf
Schedule B.pdf
B1 Agreement .pdf
Corri.01.pdf
Corri02.pdf
CORRIGENDUM
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .