Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.9 LAccepted-AOC | ₹41.9 L Quoted ₹42.0 L | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹45.8 L+₹3.8 L (9.13%)Rejected-Finance VILL PO KAMPA NEAR ASHRAM DIST NORTH 24 PGN KOLKATA WB | 24 PARAGANAS NORTH | WEST BENGAL | 743193 | ₹45.8 L+₹3.8 L (9.13%) | L2 | Rejected-Finance Not the lowest bidder |
| 3 | L3₹46.1 L+₹4.1 L (9.66%)Rejected-Finance 106 1 RAJA RAMMOHAN SARANI KOLKATA 700 009 | KOLKATA | WEST BENGAL | 700009 | ₹46.1 L+₹4.1 L (9.66%) | L3 | Rejected-Finance Not the lowest bidder |
| 4 | L4₹46.1 L+₹4.1 L (9.80%)Rejected-Finance 71 GOLA MAHAL SADAR BAZAR BARRACKPORE KOLKATA 700120 | 24 PARAGANAS NORTH | WEST BENGAL | 700120 | ₹46.1 L+₹4.1 L (9.80%) | L4 | Rejected-Finance Not the lowest bidder |
| 5 | L5₹46.3 L+₹4.3 L (10.3%)Rejected-Finance | ₹46.3 L+₹4.3 L (10.3%) | L5 | Rejected-Finance Not the lowest bidder |
Tender Value
₹41.7 L
EMD Value
₹83,380
Closing Date
8 Dec 2022, 6:00 pmClosed
GE Barrackpore
Office of the Garrison Engineer Barrackpore, Kolkata 700120
PROVN OF DRY RATION STORAGE SHED AT SUPPLY DEPOT ASC BARRACKPORE UNDER GE BARRACKPORE
2022_MES_563506_1
8722/E8
Open Tender
Civil Works
Item Rate
180 days
Barrackpore
Refer to tender documents
3 documents required · 3 mandatory
₹500
GE Barrackpore
₹83,380
Yes
26 Dec 2022
16 Nov 2022
10 Dec 2022
16 Nov 2022
8 Dec 2022
1 Dec 2022
Amount
PART-I Surface excavation in soft /loose soil not exceeding 30 cm deep and averaging 15 cm deep and getting out complete all as specified and directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundation or for shafts, well, cesspits, pier holes etc not exceeding 10 Sqm on plan and not exceeding 1.5 mtr in depth and getting out in soft/loose soil complete all as specified and directed.
Removing surplus excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting points in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading leveling, watering and well ramming in layers not exceeding 25cm, soil complete all as specified and directed.
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
Supply and filling in and spreading unwashed river sand for cushioning and covering the under ground cables in trenches and punning to provide required cover complete all as specified and as directed.
M&L for approved earth filling, earth obtained from out side of Defence land to a distance exceeding 5.00 Km but not exceeding distance 15 Km and depositing where directed and spreading and levelling in layers not exceeding 25 cm thick complete all as specified and directed.
M&L for excavating over areas, not exceeding 1.5 m deep and getting out in soft/loose soil complete all as specified and directed.
M&L for broken stone or boulders hardcore of gauge not exceeding 63mm, deposited spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for 40 mm thick cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in floor/paving etc finished even and smooth without using extra cement complete all as specified and directed.
M&L for 50 mm thick cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in floor/paving etc with WPC @ 200ml per 50Kg of cement or as per manufacturers instruction, finished even and smooth without using extra cement complete all as specified and directed. (Note: WPC shall be measured and paid seperately under relevent item as "SUPPLY ONLY")
M&L for 75mm thick PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate) as in plinth protection/floor including finishing the cement concrete surface even and smooth without using extra cement complete all as specified and directed.
M&L for PCC (1:3:6) type C1 (using 20mm graded crushed stone aggregate) as in surface channel and drains etc complete all as specified and directed.
M&L for PCC (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
M&L for 75mm thick PCC (1:4:8) type D2 (using 40mm graded crushed stone aggregate), as in sub base to footpath, floor complete all as specified and directed.
M&L for PCC (1:3:6) type C-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
M&L for cement concrete (1:2:4) type B-0 (using 12.5mm graded crushed stone aggregate) as in coping, bed plates, kerbs or mud stops, top of chajjas, basement for water tank etc rounded or chamfered on edges including necessary form work finishing the surface even and fair with using extra cement complete all as specified and directed.
M&L for cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in coping, bed plates, kerbs or mud stops, top of chajjas, basement for water tank etc rounded or chamfered on edges including necessary form work finishing the surface even and fair with using extra cement complete all as specified and directed.
M&L for RCC M-25 (design mix) (using 20mm graded stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5 m span complete all as specified and directed.
M&L for RCC M-25 (design mix) (using 20mm graded stone aggregate) as in foundations including rafts, footings, foundations beam, plinth beams, bases for columns etc , basement slabs, under-reamed piles and mass concrete etc complete all as specified and directed.
M&L for RCC M-25 (design mix) (using 20mm graded stone aggregate) as in column, pillar, piers, post and struts etc complete all as specified and directed.
M&L for RCC M-25 (design mix) (using 20mm graded aggregate) used as in slab supported on walls, beams and columns in floors roofs, landing, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L for RCC M-25 (design mix) (using 20mm graded stone aggregate) as in chajja etc complete all as specified and directed.
M&L for precast reinforced cement concrete (1:2:4) type B1 (using 20 mm graded crushed stone aggregate) as in cover slab of drain/manhole, landings cover slab for manhole, chullah hoods, chajjas, water through, managers, shelves and similar articles set in cement mortar (1:6) complete all as specified and directed. (NOTE: Cost of Form Work is deemed to be inclusive of unit rate quoted by the contractor and reinforcement shall be measured and paid Separately.)
M&L for brick work with sub class 'B' bricks locally available best quality straight or curved on plan exceeding 6m mean radius, built in cement mortar (1:6) complete all as specified and directed.
M&L for brick work with sub class 'B' bricks locally available best quality straight or curved on plan exceeding 6m mean radius, built in cement mortar (1:4) complete all as specified and directed.
M&L 40mm thick damp proof course to horizontal or vertical surface including necessary form work in cement concrete (1:2:4) type B-0 (using 12.5 mm graded crushed stone aggregate) complete all as specified and directed.
Supply only integral water proofing compound liquid, ISI marked complete all as specified and directed.
M&L for extra for forming fair finished drain or channel 40 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred, sopped ends etc complete all as specified and directed.
Add or deduct for each 25 mm girth or part there of over or under 30 cm complete all as specified and directed. (Note: For adjustment purpose only)
Providing form work to sides of concrete foundation, footing, base of column, raft & plinth beam for flat, sides and soffits (if any) of foundation and plinth beam: and similar work; vertical or to batter, rough finish surface of concrete complete all as specified and directed.
Providing form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc also splays between floors and beams etc for flat, rough finish surface of concrete complete all as specified and directed.
Providing formwork to chullah hoods, chajjas, troughs and similar items including edges for flat, rough finish surface of concrete complete all as specified and directed.
Providing form work to sides of pillar, posts, struts, piers, columns and stanchions for flat, rough finish surface of concrete complete all as specified and directed.
Providing formwork to the soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200 mm thick (horizontal or sloping ) and making flat, rough finished surfaces of concrete complete all as specified and directed
Providing formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, opening in concrete walls, floor and roofs not execeeding 20cm wide and sides of RCC/PCC walls & similar work exceeding 10cm but not exceeding 20 cm wide for rough finished surfaces of concrete, flat complete all as specified and directed.
S&F of anodised (powder coating of minimum thickness 50 micron) aluminum frame (powder coated) for doors , windows, ventilators with one or more rebates (sliding & fixed type) including jointing cleat for fixing etc complete all as specified and directed.
S&F of anodised (powder coating of minimum thickness 50 micron) aluminium door shutters (powder coated), aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. including locking arrangement, roller complete all as specified and directed.
S&F of anodised (powder coating of minimum thickness 50 micron) aluminium double leaf window and ventilator shutters, aluminum section weighing 0.55 Kg/m, including necessary joining cleat, glazing clips, rubber neoprene packing, hinges, anodised aluminium snap beading screws etc complete all as specified and directed.
S&F of double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel (heavy duty) complete all as specified and directed.
S&F of 250 mm aluminum alloy, anodised , sliding door bolt with hasp and staple (bolt type ) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminum alloy and fixed complete all as specified and directed.
S&F of 300 mm aluminum alloy, anodised , sliding door bolt with hasp and staple (bolt type ) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminum alloy and fixed complete all as specified and directed.
S&F of 200 mm long aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F of 150 mm long aluminium anodised extruded alloy handle fabricated type complete all as specified and directed.
S&F of 100 mm long cold rolled mild steel butt hinges, medium weight complete all as specified and directed.
S&F for 100 mm mortice lock vertical type of brass with 4 levers completed all as specified and directed.
S&F of floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed in floor (overall length of cover plate 140mm) complete all as specified and directed.
M&L for TMT bars 10 mm dia and over cut to length bent to shape as required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
S&F of TMT bars 6mm to 8mm dia and over cut to length bent to shape as required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L for TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
S&F of steel rolling shutter (thickness of laths 1.25mm) without ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer, erected in position as indicated push pull or manual type complete all as specified and directed.
S&F of mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or forged into spikes; framed guard bars; barred iron doors; ladders, railings, framed brackets, walk ways, frame work of water tank and similar work conforming to Fe-290-0 Gde-E-165 complete all as specified and directed.
M&L for applying evenly a coat of oil based bitumen primer confirming to IS-3384 on roof, canopy, chajja, parapet (vertical surface etc) @ 0.40 Litre / Per Sqm by the same membrane manufacturer of density 250C, 0.87 to 0.89 litre and viscosity 70-160 cps after proper cleaning the roof surfaces (horizontal/vertical) and providing APP based polymeric membrane minimum weighing 3.6 Kg/Sqm and minimum 3mm thick reinforced with polyester non wove fabric (weight not less than 150 gms / sqm) laid on primed surface with side over lap of 100 mm and end overlap of 150 mm, using bitumen torch or by LP gas torching and sealing all joints etc and ensuring complete thermo fusing and applying one coat of aluminum paint @100ml/Sqm over it all as per manufacturer's instructions complete all as specified and directed.
M&L for 100mm thick PCC (1:4:8) type D2 (using 40mm graded crushed stone aggregate), as in sub base of floor complete all as specified and directed.
M&L for 20-25mm thick machine cut kota stone slab flooring (pre-mirror polished) over and including 20mm thick screed bed of cement mortar (1:6), laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for 60mm thick machine pressed precast concrete interlocking paver block (coloured and polished) any shape and size with grey cement and pigment confirming to IS 15658-2008 (M-40 grade) laying over and including 50mm thick sand filling complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:6) on brick work or concrete surfaces of wall, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:4) on brick work or concrete surfaces of wall, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 10mm thick in cement mortar (1:3) on ceiling, chajja etc surface finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick on fair face of brick works or concrete surfaces of walls with cement mortar (1:4) mixing with mixed with WPC @200ml per 50 Kg of cement or as per manufacturer's instructions , finished the surfaces even & smooth without using extra cement complete all as specified and directed. (Note : WPC will be measured and paid separately)
M&L for applying three coats of white wash on ceiling surface including preparation of new plastered surface using smart painting technic complete all as specified and directed.
M&L for applying two coats of oil emulsion distemper over a coat of alkali resistant primer over and including applying 3 mm thick putty on wall surfaces after preparation of newly plastered surfaces using smart painting technic complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint (1st grade quality) over a coat of red oxide primer after preparation of new steel surfaces of any description over 10cm width or girth using smart painting technic complete all as specified and directed.
M&L for applying two coats of acrylic exterior emulsion paint over a coat of acrylic primer on newly pastered wall surfaces as directed by GE as per site condition after preparation of surfaces using smart painting technic complete all as specified and directed .
S&F of 5.5mm thick sheet glass ordinary quality and glazing with oil putty or fixed with bead/glazing pins in squares exceeding 0.50 sqm each pane complete all as specified and directed.
M&L for 12 mm thick medium density fibre board, exterior grade, fixed with screw/beading to aluminium frame work complete all as specified and directed
M&L for writing letters or figures (block, roman, italic or Indian) not exceeding 30cm high after cleaning and preparation of existing surfaces complete all as specified and directed.
M&L for writing stops, commas, short lines dashes, hyphens, bracket etc after cleaning the existing surface complete all as specified and directed.
PART-II M&L for point wiring complete with 1.5 sqmm PVC insulated, FR-LSH type, ISI marked, conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 20 mm dia medium grade (MMS) and including cutting, chasing work at any height and all accessories concealed in walls / roofs / floors / ceiling etc. flush mounting MS box with top, bottom, side/back wall knockout for conduit entry from any direction made out of 1.60mm thick and 50mm depth suitable for fixing of modular top cover , blanking plate as per numbers of switch modules, modular switches, sockets, fan regulators, red colour indicator, blank plates etc as approved coloures modular accessories of suitable modules and including 1.5 Sqmm PVC insulated multistranded FR-LSH type unsheathed single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surfaces by applying white/colour wash/distemper as applicable after applying of putty for smooth finish surface complete all as specified and directed for the following:- (Note:- (i) All necessary accessories such as modular box, top cover plate, blank plate, MS box, screws, washers etc are to be used of same make/brand only in relevant items. (ii) Cutting & chasing of wall for point wiring at any height shall be done and cost of the same deemed to be including with quoted rate.)
One light point controlled by one switch .
One fan point controlled by one switch and one regulator.
One 5 pin 6 amps socket point controlled by one 6 amps switch on independent board .
One 5 pin 6 amps socket point controlled by one 6 amps switch on same board .
All as per Item No.69.00 here-in-before but point wiring with 2.5sqmm PVC insulated multistranded flexible unsheathed copper conductor FR-LSH and earth conductor of size 2.50 sqmm complete all as specified and directed for the following :-
One 6 pin 6/16 amps socket outlet point controlled by one 16 amps switch on independent board.
S&F of modular switch 16 Amps, single pole, 1way, 1 module, 240V, AC, ISI marked complete all as specified and directed.
S&F of modular switch 10 Amps, single pole, 1 way, 1 module, 240V, AC, ISI Marked complete all as specified and directed.
S&F of modular socket shuttered type 10 Amps, 2/3 pin combined 2 module, 240 V, AC, ISI marked complete all as specified and directed.
S&F of modular socket 6/16/20 Amps, 6 pin combined shutter socket, 2 module with light indication, 240 V, AC, ISI marked complete all as specified and directed.
S&F of modular fan regulator, electronic, stepped type (01 to 4/5), 100 to 120 Watts, 2 module, 240Volts, AC, ISI marked complete all as specified and directed.
S&F of angle lamp holder, insulated body with back plate for batten fittings with and including LED lamp 10 watts complete all as specified and directed.
S&F of ceiling rose , three terminal, PVC/polycarbonate body, ISI marked complete all as specified and directed.
S&F of decorative box type 20 -22watt LED fittings with and including LED T-8 tube light 20 watt of fire retardant engineering grade complete with all accessories internally pre-wired, connecting up with and including three core sheathed flexible copper conductor cable of required size and including mounted on PVC/Wooden round/square blocks-02 Nos complete all as specified and directed. (Make - Havells Cat No REGALBATTENT8UPTO1 x 22WDSBSWH/Crompton Greaves cat No : DMLN1LT8-16 for fittings and make - Crompton Greaves Cat No LTT8-20 for tubes /Havells Cat No PHOTONULTRAE2.01213T8SSTL20WLED865SPC/Rashmi Cat No. RLTU20TLT8 as approved for LED lamp or equivalent model/Cat No of make as per Appx 'A' as mentioned in PS here-in-after)
S&F of recess mounting 2'x2' LED 36/40 Watt light fittings with LED lamp and required driver, slim in class LED ceiling panel with best in class aesthetic white powder coated frame blended seamlessly with ceiling layout modular ceiling grid and also can be suspended with provided kit and necessary electric connection with and including required size three coat sheathed flexible copper conductor cable from looping box to light fitting and testing complete all as specified and directed. (Make: Bajaj Cat No. BCTBLR 36W LED FP CW/Crompton Greaves Cat No.LCTLSNE-36-F0-CDL/ Havells Cat No.PLUTOSURFACE4X1PLS34WLED857S / Philips Cat No. RC 380B LED36S 6500 G4 L60 W60 PSU ODOC or equivalent model/Cat No of make as per Appx 'A' as mentioned in PS here-in-after)
S&F of powder coated sheet metal enclosure acrylic door 415 volts AC,TPN distribution board 4 way suitable for flush mounting with 100amps copper busbar, neutral bar, earth bar and MCB incomer of rating upto 100Amps, MCB SPN/DP, and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coat complete all as specified and as directed. (Make:- Legrand cat No. 5076 80 4 way /L&T Cat No. DBTPN004GD or equivalent model/Cat No of make as per Appx 'A' as mentioned in PS here-in-after)
S&F of powder coated sheet metal enclosure acrylic door 240 volts AC, SPN distribution board 8 way for flush mounting with 100amps copper busbar, neutral bar, earth bar and MCB incomer of rating upto 100Amps, MCB SPN/DP and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface & colour coat complete all as specified and directed. (Make: Legrand Cat No. 5076 21 8 way / L&T Cat No.DBSPN008GD or equivalent model/Cat No of make as per Appx 'A' as mentioned in PS here-in-after)
S&F for 35/36 watt LED secruity light fitting, with LED lamps in aluminium PDC housing, toughened glass cover with IP66 protection with minimum 4kv inbuilt surge protector and cable connection from looping box to light fitting and testing complete all as specified and directed . (Make:- Bajaj Cat No. BRTFG 72W LED V3/ Crompton cat No.CRP-409-70-57-SL-GL-NSG /Havells cat No.ENDURACITYLINERNEOSL70WLED757PASYBOTG or equivalent model/Cat No of make as per Appx 'A' as mentioned in PS here-in-after)
Supply, fabricated and fixing of street light bracket made out of GI pipe 40mm dia medium grade bent to shape of 1.2 mtr long as directed including clamps made out of 30 mm x 6 mm flat iron for fixing bracket suitable for steel tubular poles including nuts and bolts, washers and other connected items of required size including painting with two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
S&F of MCB, SP, 6 Amps to 32 Amps , 'C' series, 240 Volt, 10KA, 50 Hz, ISI marked complete all as specified and directed
S&F of MCB, SPN, 40-63 Amps, 10 KA, 'C' series, AC, 240 volts, ISI marked complete all as specified and directed.
S&F of MCB, TPN, 40-63 Amps, 10 KA, 'C' series, AC, 240 volts, ISI marked complete all as specified and directed.
M&L for earthing with glavanised steel earth plate electrode of size 60cmX60cmX6mm thick buried directly in ground (earth pit not less than 2.25 m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel using GI or steel wire 4mm dia as earthing lead as shown in electrical plate No.3 of SSR Part-I connected to earthing test point all specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC (1:3:6) type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe , 15mm dia GI medium grade earth lead protection pipe and pre-cast earth pit cover 50mm thick made of RCC (1:1.5:3) type A-1 duly reinforced with 8mm dia TMT bar @150c/c both ways, one lifting handle made out of 10mm dia TMT bar 250 mm long embedded in cover slab and cover, wire, copper lugs etc mesh, charcoal and common salt in alternate layer of 15 cm thick complete all as specified and directed. (Note: Galvanised iron wire of 4mm dia upto 7.5m long including testing is deemed to be included with quoted rate).
S&F of ceiling fan of size 1400 mm sweep, high speed, single phase, 240Volts, AC, 50Hz, BEE 5 Star rated as approved colour and including hanging GI hook with necessary suitable MS clamps and connecting cable three core 0.75 sqmm round PVC sheathed from ceiling rose to fan connector and testing complete all as specified and directed. (Make:- Havells model No. Samraat or equivalent model of Crompton Greaves/Usha/Bajaj as approved)
S&F of heavy duty air circulator wall fan, electrically operated, 230 volts, AC, single phase type, 50 Hz of rating 100 watts having size 450mm of 1440 RPM, 03 Nos metal blade complete with fron and rear powder coated grill complete all as specified and directed.
M&L for XLPE insulated, LT armoured electric cable with aluminium stranded conductor 1100 volts grade, cross-sectional area 25 sqmm, 3.5 core laid in trenches/pipes/ducts/wall/borings with necessary cable lugs and glands, nuts, bolts and washers etc and testing complete all as specified and directed. (NOTE: Excavation/earth work, sand cushioning, cable cover/brick shall be measured and paid separately if required)
M&L for brick covering with width equal to length of brick as protection to cable with well burnt sub class ‘B’ bricks of size 250mm x 115mm x 75mm laid dry flat complete all as specified and directed .
M&L for sand cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep including required watering and consolidation after laying and stretching the cable complete all as specified and directed. (Note: Only punned down volume of sand to be measured)
M&L for sub main wiring complete with 2 run of 4 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through and including rigid PVC conduit of required size medium grade (MMS) with all connected accessories such as Bend, Tee, Elbow, Short pieces etc concealed in wall/roofs/floors and including one run of 4 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including chease cutting and filling the same with cement mortar and finished with putty and making good the disturbed surfaces to match with existing surface as required for concealed work complete all as specified and directed. Note : (i)Two runs of cable with one run earth wire and PVC conduit shall be measured as one length. (ii) Extra length of cable required for connection to DBs shall be deemed to be included in the unit rate and shall not be measured separately. (iii) Earth wire shall run inside the conduit. (iv) Suitable color code of wire must be ensure for phase/netural/earth. (iv) All surface cutting/making good for wiring/switch board/junction box/DB etc are included with unit quoted rate.
M&L for galvanized iron tubing 40mm dia (medium grade) in any length including embedded in wall two ends duly welded MS holdfast at two ends of GI pipe and providing PCC in wall and making good disturbed surfaces complete all as specified and directed.
M&L for GI pipe 50mm dia (light grade) complete with all fittings in trenches, road/culvert crossing, floors, on roof, on pole for cable protection complete all as specified and directed.
azad enterprise
M/S H.P Singha
Shree Mahabir Builders
M/S PAUL CONSTRUCTION
SHIVAM ENTERPRISE
DECORATIVE CONSTRUCTION
M/S D K Singha
ALOKE ENGINEERING AND COMPANY
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .