Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.9 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹20.4 L+₹32,936.75 (1.64%)Rejected-Finance | L2 | Rejected-Finance Rejected due to bidder is not L1 |
Tender Value
Refer Docs
EMD Value
₹38,800
Closing Date
17 Nov 2020, 6:00 pmClosed
Sh K A Vardhan, IDSE
Office of the GE (Army) Camp Hanuman, Ahmedabad - 380 004
SPECIAL REPAIR TO OTM BLDG NO P 263 OR MESS OF 11 INF DOU AND CERTAIN SANCTION WORKS UNDER GE A AHMEDABAD
2020_MES_380571_2
8119/E8
Open Tender
Civil Works
Item Rate
180 days
GE (Army) Ahmedabad
AS PER NIT
9 documents required · 9 mandatory
₹500
GE (Army) Ahmedabad
₹38,800
Yes
2 Feb 2021
27 Oct 2020
19 Nov 2020
27 Oct 2020
17 Nov 2020
3 Nov 2020
27 Oct 2020 - 3 Nov 2020
Amount
Taking down chowkats or frame with shutters ( without taking off shutters from the frame) n.exc 1.5 sqm each complete all as specified and directed.
Taking down chowkats or frame with shutters (without taking off shutters from the frame) exc 1.5 sqm and n exc 4.0 sqm each complete all as specified and directed.
M&L for 150mm long extructed aluminium handle fabricated type complete all as specified and directed.
S&F Aluminium anodised barrel tower bolt of extruded section 150 mm size complete all as specified and directed.
S&F factory made solid PVC door, cup board shutter 30mm thick (Style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded both side prelaminated PVC 'C' channel having a prelaminated PVC sheet strip of 20mm width stuck inside with solvent cement for stiles & PVC sheets for top rail, lock rail and bottom rail on either side & as gap insert for top rail, lock rail & bottom rail panelling of both side prelaminated PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading & jointed together with solvent cement, supply & fixing in the frame at site as per SSR specification & diagram/product drawing shown on ser page No 156 of SSR Part II complete all as specified and directed & directed
S&F solid PVC door, cup board frame size 50mmx47mm made out of 5mm prelaminated PVC sheet reinforced with MS square tube all as per specification and as per drawing shown on ser page No 150 of SSR Part II (for item 884) complete all as specified and directed and directed
S&F aluminium powder coated door single/double shutter with frame size 100 x 44 x 1.98 mm with one or more rebate and shutter pull and push type or side hung type ( with or without shah bar) comprising of top and lock rails of section 115 x 44 x 1.98 mm thick , bottom rail of section 150x44x1.98 mm thick and styles of section 85x 44 x 1.98 mm thick including necessary joiting cleats , glazing clips , rubber packing anodised aluminum beading , screws , anodised aluminum fittings such as floor springs or hinges 100 mm size with hydraulic door closer , handles D type 125 mm , floor door stopper, tower bolt 200 mm sliding door bolt 300 mm or mortise lock , 5 mm thick tinted glass panes top and prelaminated particle board bottom including making good wall surfaces etc., complete all as specified
S&F aluminium powder coated framed windows, any pattern, fixed/side hung/sliding Three track using powder coated aluminium sections or approved make, with or without sash bars, suitable for 5 mm thick glazing and stainless steel alloy wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm wire guaze, including necessary rubber packing, joining cleats, glazing clips, aluminium snap beading, handles, locking arrangements, frame of window should be of 1.5 mm thick section & shutter sec like handle/interlocking/top/bottom should be of 1.2 mm thick etc , complete all as specified and as directed Note :Rates include all glazing/aluminium wire cloth, rubber packing, joining, cleats, glazing clips, aluminium snap beading, locking arrangements, handle etc complete all as specified and directed.
S&F powder coated aluminium ventilator partly louvered and partly fixed with and incl 4 mm thick frosted glass , 0.36mm dia and 1.18mm aperture stainless steel jally (Fixed outside of frame) complete.
M&L for grill medium grade of mesh size 75mmx75mm with 6mm square Prelaminated aluminium bars fixed with suitable aluminum frame of size 37x19x2mm and complete all as secified and directed.
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for Vitrified Ceramic coloured tiles light shade 10 mm thick (square/rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 1.0 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM 1:6 complete all as specified and directed.
All as per item No 12 above but on vertical Surfaces with including 10mm thick backing coat in CM 1:4 complete all as specified and directed.
M&L for Non Skid joint free ceramic coloured tiles 7mm to 8mm thick, (square or rectangular) area of each tile exc 0.06 Sqm but n. exc 0.11 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed CM 1:6 complete all as specified and directed.
M&L for Glazed ceramic coloured tiles of size 450X 300X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match 15mm thick backing coat CM 1:4 complete all as specified and directed.
M&L for 16 to 18 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and with backing coat of 10mm thick in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade complete all as secified and directed.
M&L for pre Polished Chequered cement concrete tiles 30cm x 30cm x25mm thick on horizontal surfaces,set, jointed and pointed in neat cement slurry in floors including 15mm thick screed bed in CM 1:6 complete all as secified and directed.
Removing of existing un-serviceable water proofing treatment , taking down cement plaster etc, of any description and claening of top surfaces of cement concrete flushing out junction of parapet walls and washing down with water complete all as specified and directed.
M&L for water proofing treatment to non accessible RCC roofs by providing 10mm thick screed in CM 1:3 mixed with & including water proofing compound @ 3% by weight of cement & applying one coat of bituminous primer @ 0.30 kg/sqm & laying APP based polymer modified membrane with polyster non woven reinforced of weight not less than 3 kg/sqm 3mm thick with polythene finished sealing with side over laps of 75mm & 100mm laps at the ends of membrane by torch application method & applying two coats of aluminium paint as per the makes approved by the Engr-in-Charge.
M&L PCC 1:2:4 type B0using 12.5mm graded stone aggregate as in, levelling coarse complete all as specified and directed.
Taking down cement or lime plaster of any description from stone or brick walls etc including racking out joints, hacking for key scrubbing down with water and disposing off the rubbish complete all as specified and directed.
M&L for 15mm thick rendering on fair faces of brick/ concrete surfaces in CM (1:4) finished even and fair without using extra cement with 2% Water proofing compund complete all as specified and directed. Note : WPC shall be ,measured and paid separatly.
M&L for 10 mm thick rendering on surfaces other than fair faces of brick/concrete surfaces in CM (1:6) and finished even and smooth without using extra cement complete all as specified and directed.
M & L for 5mm thick rendering on cement concrete as in ceiling with cement mortaar 1:3 complete all as secified and directed.
Supply only Integral waterproofing compound.
Demolition of Brick work or stone/boulder masonry, build in cement mortar or cement lime mortar including all quions, arches, pillars etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
M&L for brick work with sub class 'B' bricks built in CM (1:6) straight or curved on plan & exc 6 m mean radius with old size bricks complete all as specified and directed.
Demolition of cement concrete unreinforced of any description and in any position not otherwise specifically provided for where directed.
M&L for cement concrete (1:3:6) type C-2 using 40mm graded stone aggregate 75mm thick as in plinth protection including necessary form work and finishing surface even and smooth w/o using extra cement including bitumen joints complete all as specified and directed.
Taking up or down steel tubing and connections, including cleaning for re-fixing or removal to store complete all as specified and directed.
S&F 15mm bore tubes, `medium grade', galvanised, with all fittings and fixed complete concealed in walls and ceilings or laid in floors complete all as specified and directed.
S&F 20mm bore tubes, `medium grade', galvanised, with all fittings and fixed complete concealed in walls and ceilings or laid in floors complete all as specified and directed.
Dismentling water tank exc 500ltr capacity but n. exc 1000ltr capacity and removing rubbish off the premises from site out side of MD land complete all as specified and directed.
Providing and fixing of Water tanks rotational moulded exc 500ltr capacity but n. exc 1000ltr capacity, open or closed, hoisted and fixed in position complete all as specified and directed.
S&F Ball brass valve, high pressure, with polythene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed, 20mm bore, fixed in repair complete all as specified and directed.
S&F in repair stop cock 15mm cast copper alloy,screwed down, with chromium plated fancy type high pressure screwed both ends for iron pipe or for union complete all as specified and directed.
S&F in repair bib taps 15mm bore of CP Brass copper alloy chromium plated fancy type, screwed for iron pipe or for brass ferrule & fixed complete all as specified and directed.
S&F soap dish of 1mm thick stainless steel box type fixed with screws of size 150mmX150mmX100mm complete all as specified and directed.
S&F vitreous china wash basin, white flat back size 550x400 mm including waste pipe, brackets and cutting for and pinning in ends of brackets or errecting stand but excl taps, chain and plug complete all as specified and directed.
S&F tubular towel rail 20mm dia D type and 60cm long including brackets fancy type brass chromium plated complete all as specified and directed.
S&F grating PTMT square of size 150mm complete all as specified and directed.
Demolition and breaking up drain pipes ( CI ,salt glazed ware,AC or Reinforced concrete) set in cement mortar internal dia of pipein 100mm complete all as specified and directed.
M&L for 75mm bore fixed in repair C I soil waste and vent pipes sand cast, in any length with or without ears with cement jonts fixed to wall complete all as specified and directed.
M&L CI bends 75mm ( any radius), diminishing pieces or tapers( larger bore measured)Fixed in repairs complete all as specified and directed.
M&L for preparation of new plastered surfaces on walls and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed.
M&L Preparation of old or previously treated steel surfaces of any description not other wise described, over 10cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and as directed by EIC.
M & L applying 1 mm thick wall care putty on wall for smothening of surfaces complete all as specified and directed.
M&L for preparation of new plastered surfaces on wall and applying two coats of exterior emulsion paint with anti algeal properties(Apex ultima or equivalent) on over one coat of primer on walls complete all as specified and directed.
M&L complete removal of existing treatement and applying two coats of oil bound distemper over a coat of primer on old plastered or un-plastered surfaces on ceiling complere all as specified and directed by Engr-in-Charge
M&L for complete removal of existing treatment and applying two coats of exterior emulsion paint with anti algal properties(Apex ultima or equivalent) on over one coat of primer on walls complete all as specified and directed.
S&F in repair pillar taps cast copper alloy with capstan heads chromium plated screwed down high pressure with long screwed shanks and fly nuts screwed for iron pipe, 15mm bore fancy type complete all as specified and directed.
M & L for machine cut kota stone slab size as in flooring, stair case landing. treads of steps etc, 20-25mm thick laid over 20mm thick screed bed in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M & L for machine cut kota stone slab size as in skirting, dado, vertical surfaces etc, 20-25mm thick including 15mm thick backing coat in CM 1:3 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L polishing for old kota surface to make it clean and free of dirt as directed by EIC.
S&F aluminium powder coated section size 38 x 38 x 2mm for partition all other members channel tracks including gasket aluminium cleat 6 mm dia rounded bars, 5mm thick tinted glass panes/ SS wire cloth aperture not exc top and prelaminated poarticle board bottoms including aluminium handle hinges and locking arrangement, sliding rail, rollers etc., complete all as specified
M&L for providing and injecting chemical emulsion for post constructional antitermite treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc complete all as specified and directed.
M&L for treatment of soil under existing floors using emulsion @ one litre per hole,300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and directed.
S&F 2nd hard wood factory made 35mm thick glazed, and skeleton shutters open rebated & prepared to receive, glass, gauge etc. divided into squares with plain chamfered or rounded mitred and rebated any numbers and size of members of shutters as specifed in SSR Part I, Section 8, clause 8.24(a); supllied and fitted to chowkahts complete all as specified and directed.
S&F 2nd class hard wood factory made plain framed Flush shutters 40mm thick solid core construction, with block board core and plywood face panels, commercial type on both sides as per IS:1003 (Part I), Klin seasoned and chemically pressure treated complete all as specified and directed.
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm fixed with stainless steel wire staples complete all as specified and directed.
M&L preparation of new wooden surfaces of any description, not otherwise described, over 10cm width or grith and apply two coats of synthetic enamel paint over one coat pink primer complete all as specified and directed.
M&L for preparation of newly plastered surfaces or old existing surface of ceiling and applying two coats of white wash complete all as specified and directed.
S&F in repair sink made of stainless steel 1mm thick kitchen with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mmx420mm and bowl size 410mmx330mmx160mm complete all as specified and directed.
S&F 0.63 mm thick stainless steel plate rack of size 31"x36"x10" complete all as specified and directed.
Excavation in trenches n exc 1.50m wide and n exc 1.5 m deep for foundatiuon in soft/loose soil complete all as specified and directed.
Returning filling in trenches including spreading levelling, watering well ramming in layers n exc 25 cm in soft/loose soil (from available soil) complete all as specified and directed.
Removal of exavated material such as soil n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed.
M&L for cement concrete 1:4:8 type D2 (using 40mm graded aggregate) in foundation filling & mass concrete complete all as specified and directed.
M&L for spreading excavated earth obtain from item No 66 above, levelling in layers n ex 15cm thick and rammed including watering complete all as specified and directed.
M & L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick (Flat) complete all as specified and directed.
M & L for reinforced cement concrete (1:2:4) type B1 (20mm graded aggregte) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M & L for cement concrete (1:2:4) type B1 (20 mm graded aggregate) providing, precast cement concrete in window or door cills, lintels, bressummers, steps, quoin blocks (for use with masonry), string courses, copings, kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, anchorage blocks, bonders (for stone walling), corbels, brackets, etc.(of any section indicated), with plain fair faces, including chamfers weatherings, throating etc. and setting in mortar complete with joints to match
M&L for mild steel TMT bars 10mm dia and over cut to length, bent to shape required, including cranking bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire not less than 0.9mm dia or seuring with clips complete all as specified and directed.
All as per item No 74 above but 6 to 8mm dia bars
S&F roof trusses (framed) trusses purlins and fastening (etc.,angle, channel) or flat section including distance pieces,MS plates/gusset plates, cleats, hold fast etc., Fe 410-W (gde E-250) quality -B complete all as specified and directed.
S & F prepainted galvalume aluminium zinc coating GI base corrugated steel sheet 0.50 mm thick of approved colour having tensile strength of 550 Mpa as in roof covering / clading to wall, fixed with self tapping screws as specified. Complete all as spd and directed. (Note : Corrugation shape of sheet shall be approved by GE)
S & F prepainted galvalume aluminium zinc coating GI base plain steel sheet 0.50 mm thick of approved colour having tensile strength of 550 Mpa as in ridge, hips, valley,gutters and straight flashings cut to length and bent to shape required, fixed with self tapping screws as specified complete all as specified and directed.
M&L for 10 mm thick rendering on (internal) fair faces of brick work/concrete surfaces in CM (1:6) finished even and smmoth without using extra cement complete all as specified and directed.
M&L for 10 mmthick rendering on (external) other fair faces of brick/concrete surfaces in CM (1:4) finished even and fair without using extra cement complete all as specified and directed.
M&L for preparation of new surfaces of walls of any description and applying two coats of cement base paint over one coat of white wash complete all as specified and directed.
M&L for preparation of new surfaces of wall and applying three coats of colour wash complete all as specified and directed.
M&L for preparation of new surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
M&L for hardcore broken boulders of guage n. exc63mm, deposited, spread & leveled in layers n exc. 15 cm thick, watered & rammed to a true surface complete all as specified and directed.
M & L for 40 mm thick damp proof course in cement concrete (1:2:4) type B0 using 12.5mm graded stone aggt to horizontal or vertical surfaces including water proofing compound and necessary formwork complete all as specified and directed.
M & L for excavation in post holes (or similar holes) n.exc 0.5 cum on plan and getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering and removing surplus soil to a distance 50m complete all as specified and directed.
M&L for cement concrete 1:3:6 type C2 (using 40mm graded aggregate) in foundation filling & mass concrete as in post complete all as specified and directed.
S & F joist,channel,angle ,or tee sections,fixed independently, without connecting plates,etc (cut to ordinary lengths i.e. within 20mm of the length) conforming to Fe-290 (Gde E-165) complete all as specified and directed.
M&L Cutting holes exc 100sqcm but n exc 250 sq cm into or through cement concrete slabs, wall, chajjas, etc. reinforced or otherwisemaking good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required complete all as specified and directed.
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed.
Surface dressing n exc 15 cm deep in soft/loose soil complete all as specified and directed.
M & L for 75 mm thick plain cement concrete 1:4:8 type D-2 (40 mm graded stone aggregate) as in sub base complete all as specified and directed.
M & L for sand filling under floors including watering and consolidation complete all as specified and directed.
M & L for providing precast cement concrete rubber moulded coloured interlocking tiles 60 mm thick with grey cement and pigment of approved design and pattern laid on floor complete all as specified and directed by Engr-in-Charge.
Surface excavation n. exc 30 cm deep & averaging 15 cm deep and getting out in any type of soil and getting out including cleaning away all grass, vegetation, saplings, shrubs, brush wood, under growth rootsand trees not exceeding 30 cm girth (measured 1 meter above ground level) and removing rubbish to a distance of 50 meter outside the periphery of the area.
Excavating over areas not exceeding 1.5 m in depth and getting out in soft/loose soil complete all as specified.
M & L for brick work with sub class 'B' bricks (old size bricks) straight or curved on plan exc 6m mean radius, built in cement mortar 1:4 complete all as specified.
M & L for 50 mm thick cement concrete type B-2, 1:2:4 (40mm graded aggregate) including necessary form work as in flooring, surface finished even & mooth without using extra cement complete all as specified.
M & L for 50 mm thick cement concrete type B-2, 1:2:4 (40mm graded aggregate) including necessary form work as in plinth protection, surface finished even & smooth without using extra cement complete all as specified.
M & L for flush pointing to brick wall in CM 1:4 all as specified and directed.
M & L for KEYED pointing to brick wall in CM 1:4 complete all as specified and directed.
M&L mild steel, plain black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as requiraed complete all as specified. Thickness of sheet 1.25 mm as in chimney.
Mild steel Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc, complete drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering, running rails and guides) and hangind; also fastening and fixing complete Fe 410-W (Gde-E-250) quality A
M&L PCC (1:2:4) type B-2 using 40 mm gradedcrushed stone aggregate as in surface channel and drain complete all as specified
M & L for forming fair finished drain or channel 40cm inner girth in cement concrete,using extra cement,including forms,moulds,mi-tred,stopped ends etc complete all as specified and directed.
M&L for PCC 1:3:6 type C1 using 20 mm graded agg as in copping incl. necessary form work & finishing exposed surface of concrete complete all as specified and directed.
M&L rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:6 finished even and smooth without using extra cement complete all as specified and directed.
Taking down carefully surface aluminium or copper point wiring with PVC casing-caping (light, fan, socket, bell or power) including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc and making good disturbed surfaces complete.
Point wiring with 1100 volts grade PVC insulated FRLSH multistranded copper conductor cable 1.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and sunken galvanized pressed steel terminal boxes of thickness not less than 1.2 mm covered with 3 mm thick phenolic laminated white sheet cover for mounting switches, sockets, fan regulators complete for the following :-
One light point controlled by one switch.
One fan point controlled by one switch.
One socket outlet 6 amp controlled by one switch on the same board with other switches.
One socket outlet 6 amp controlled by one switch on indepdendent board.
Point wiring with 1100 volts grade PVC insulated FRLSH multistranded copper conductor cable 2.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 2.5 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and sunken galvanized pressed steel terminal box of thickness not less than 1.2 mm covered with 3 mm thick phenolic laminated white sheet cover for one 16 amp socket outlet controlled by one switch on independent board complete.
S&F switch piano flush button single pole one way 6 amp complete.
S&F switch piano flush button single pole one way 16 amp complete.
S&F socket outlet 2 in 1, 3 pin 6 & 16 amp flush type complete.
S&F socket outlet 2 in 1, 2 & 3 pin, 6 amp, flush type complete.
S&F hum free electronic step fan regulator 120 - 280 volts of 100 watt capacity including connecting up complete.
S&F ceiling rose 6 amp, 3 plates polycarbonate body complete.
M&L for submain wiring alongwith earth continuity conductor with PVC insulated FRLSH multistranded copper conductor cable (Phase - Red, Neutral - Black, Earth - Green) drawing into and including concealed rigid non metallic PVC conduit, medium grade, ISI marked ivory colour along with accessories of following nominal sizes:-
2x4 sqmm + 1x4 sqmm earth continuity conductor in 20 mm dia conduit..
2x6 sqmm + 1x4 sqmm earth continuity conductor in 20 mm dia conduit..
S&F LED batten (1.2 m) made of Aluminium housing with a PC glossy diffuser duly prewired connection having a nominal system lumen output of 2000 lumens at a minimum system efficacy of 100+ lumens per watt and total power consumption not less than 20 watt including driver. It has a rated system life time of 40000 burning hours at L70 and should have a color temperature of 6500K, CRI>80, THD < 10% and PF > 0.95 complete. Make : Philips cat ref no. ENDURALED BATTEN " BN 108C LED 20S PSU CDL WH " or Havells Lumiline plus / GE lighting /Wipro as approved.
S&F LED bulkhead fitting 9 watt IP 66 & IK 09 with pressure diecast aluminum housing & polycarbonate diffuser duly prewired for connection with flexible multi stranded copper conductor cable as required all as per Philips cat ref no. WT202W LED6S CW PSU S1 PC or equivalent in Wipro or GE lighting or Havells as approved.
M&L for pipe in pipe chemical earthing with GI pipe electrode 3.0 m long having outer pipe nominal dia 80 mm & inner pipe nominal dia 50 mm duly filled with highly conductive and anti corrosive compound of required quantity having chemical composition Bentonite 40%, copper sulphate 20%, Gypsom 5%, Graphite 10%, Alum 5%, Zinc sulphate 10%, Aluminium sulphate 10% burried in ground by digging a bore of 150 mm dia surrounded by soil friendly backfill compound non soluble in water including connection with galvanised earth wire 4 mm dia from pit to main MCB DB protected in 15 mm GI pipe light grade, making PCC pit of size 0.3 m x 0.3 m x 0.3 m (inner size) in mix 1:3:6 type C1 with RCC 1:2:4 type B-1, 40 mm thick cover reinforced with 8 mm dia MS bars 3 Nos both ways with lifting hook made out of 8 mm dia bar and testing on completion to achieve value not more than 1.0 ohm complete.
S&F MCB distribution board SPN, 240 volts, 8 ways powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 43 - IK 09 with metal door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required.
S&F MCB distribution board ETPN, 415 volts, 4 ways powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 43 - IK 09 with metal door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required.
S&F MCBs as per load requirement 'C' series of breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs of following ratings:-
Single pole 6 to 16 amp. Make - Legrand DX3 cat ref no. 408587 to 408592 or equivalent in Schneider or Hager as approved.
Double pole 32 amp. Make - Legrand DX3 cat ref no. 408636 or equivalent in Schneider or Hager as approved.
Four pole 63 amp. Make-Legrand cat ref no. 408702 or equivalent in Schneider or Hager as approved.
Taking down carefully aluminium or copper submain wiring with PVC surface conduit or casing caping and making good disturbed surfaces complete.
Taking down MCB distribution boards with incoming and outgoing controls any make, any capacity after disconnecting complete.
Supply & fix exhaust fans AC single Phase 230/240 V of size 300 mm sweep with louver, metal body. Make:- Khaitan / Havells / CG / Almonard.
Taking down Ceiling Fan of any make, type and sweep by disconnecting Electric Connection and keeping in safe castody for repair.
Hanging only ceiling fan and connecting up including provision of cable ceiling rose or connector to fans as directed.
S&F Power unit for AC or geyser 3.5 KW 4 module including sunken modular GI metal boxes not less than 1.2 mm thick and white modular mounting plates with frame all as per Legrand Mylinc cat ref no. 675558, 689009, 675564 & 675584 or eqivalent in Schneider Zencelo or MK Blenze as approved.
S&F wall mounted fan with powder coated guards and blades of approved colour, AC single phase, 230 volts, 50Hz, 1440 rpm, 400mm sweep with adjustable verticle angles & three speed controls mounted within reach of hands with necessary connecting cables recommended/ provided by manufacturer complete. Make: Havells/ Almonard/ Bajaj/ Khaitan as approved.
S&F MCB distribution board SPN, 240 volts, 4 ways powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 43 - IK 09 with metal door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required.
S&F steel tubes light grade galvanised with all fittings fixed to walls / floors / poles / road crossing etc of 40 mm bore complete.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 sqmm 2 core complete. Make - Havells / Polycab / Finolex as approved.
M&L for sand filling in trenches with clean dry fine sand unwashed including gently punning around cables complete.
Supplying and laying old size bricks, common burnt clay building bricks sub class 'B' designation 75 laid in trenches over sand for cable protection complete.
Supplying, laying or fixing or passing through pipe, testing and commissioning 1100 volts grade XLPE insulated and PVC sheathed steel tape / wire armoured solid aluminium conductor cable of nominal cross sectional area 10 sqmm 4 core complete. Make : Polycab/ Havells / Finolex
Supplying and laying un-reinforced precast concrete cable cover, class LV, Type 1 flat size 250mm x 150mm x 40mm for protection of LT cable complete all as specified and directed.
M&L for steel tubular swaged pole 8.5 m long type 410 SP-22 with cast iron or welded MS base plate including nuts / bolts / washers etc conforming to IS-2713 (Part I to III) of 1980 and including the following :-
Excavation in post holes in any type of soil not exceeding 0.5 cum each, getting out, returning filling in and ramming earth in layers not exceeding 25 cm watering and disposal of surplus soil to a distance not exceeding 50 m and making good surface complete.
PCC (1:4:8) type D2 using 40 mm graded stone aggregate in base (0.60 m dia x 0.15 m height).
PCC (1:3:6) type C2 using 40 mm graded stone aggregate in foundation filling (0.60 m dia x 1.5 m height).
PCC (1:2:4) type C2 using 40 mm graded stone aggregate in coping (0.60 m dia x 0.45 m height).
Pole cap 0.30 m long externally fitted on pole top duly welded with a light grade ISI marked GI pipe bracket 1.5 m long for mounting street light fitting.
Painting with aluminium paint one under coat, one finishing coat over a coat of red oxide primer and making alternate colour bands of black & white colours in 30 cms width upto a height of 1.5 m from pole coping with synthetic enamelled paint complete.
S&F street light junction box with thermoplastic, IP 65 cable junction box with metric knockouts on all sides for cable entry size: 200 x 160 x 98 mm as per Hensel cat ref no. K 9250 or equivalent in Eaton or Rittal or Secure duly fitted with followings:-
One number DIN Rail (35 mm).
Four numbers ELMEX or equivalent make connector of 10 sqmm.
One number ELMEX or equivalent make end plate.
Two numbers ELMEX or equivalent make end clamps.
One number MCB SP 6 amp, 10 KA, 'C' series of Legrand make (cat ref no 408587) or equivalent in Hager or Schneider as approved.
Supply, installation, testing and commissioning of integral driver LED street light with a nominal system lumen output of 7200 lumens and a minimum system efficacy of 90 lumen/watt. The luminaire shall have rated system lifetime of 50,000 burning hours before reaching at L70. The luminaire should have cool white colour temperature (CCT > 5000K) and a CRI >70. The luminaire shall meet IP 66 rating & IK05 rating with THD < 20% & PF > 0.9. The luminaire housing should be made of pressure die cast aluminium with a flat glass optical cover. The total power consumption should not exceed 72 watt including driver and suitable capacity of copper cable from junction box to light fittings for connection complete. Make - Philips Greenline cat ref BRP410 LED CW 072 MR FG S1 PSU GR or equivalent in Havells cat ref ENDURAPERLSPLUSSL70WLED757SASYTOPC or GE lighting /Wipro as approved.
Supply and Installation of Deep Freezer glass top 405 litre capacity having double door . Make:- Voltas Cat ref No HC-405GTDD or equivalent in Daikin / BlueStar as approved.
Supply and fix Deep Freezer glass top 320 litre capacity having single door,BEE 5 star rated . Make : Voltas Cat ref No HC-402GTDD or equivalent in Daikin / Blue Star as approved.
Supply and fix water cooler electric driven (single phase) ,having approx storage capacity of 80 litre and nominal cooling capacity of 40 litres per hour. Make : Blue Star Cat ref No SDLX4080B or equivalent in LG /Samsung as approved.
SNEH TRADERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .